Development of the First Combined Heat and Power Plant in the Caribbean (CHP District Energy)

Similar documents
CHP Case Studies. Midwest CHP Application Center (MAC) .org (312) University of Illinois at Chicago Energy Resources Center UIC

Condenser Water Heat Recovery"

POWER TO PROFIT INTRODUCTION TO COMBINED HEAT & POWER

Achieving a cost optimal balance between heat supply efficiency and moderation of demand

Heat Recovery. Integrated CHP Systems Corp.

Ground-Coupled Heat Pump And Energy Storage

BUILDING FOR THE FUTURE

Cogeneration. Thermal Chillers. and. .. ASHRAE National Capital Chapter. Arlington, VA 10/10/2012

Solar Energy Technologies

Texas Hospital. Central Plant Redesign. Central Utility Plant SECOND PLACE HEALTH CARE FACILITIES, EXISTING 2013 ASHRAE TECHNOLOGY AWARD CASE STUDIES

Implications of Measured Commercial Building Loads on Geothermal System Sizing

OPTIMIZATION OF DISTRICT HEATING SYSTEMS

Chapter 2.7: Cogeneration

ENERGY AND WATER CONSERVATION AND DEMAND MANAGEMENT PLAN

Combined Heat & Power (CHP) in New Jersey

LIFE CYCLE COST ANALYSIS OF WASTE HEAT OPERATED ABSORPTION COOLING SYSTEMS FOR BUILDING HVAC APPLICATIONS

Optimisation and Cost Analysis of a Lithium Bromide Absorption Solar Cooling System

CHP and Enwave March 2017

AEE Technical Roundtable Measurement and Verification. Alec Stevens, PE April 8, 2014

Pharmaceutical Sustainability Initiatives

BEYOND O&M. Shawn Maurer SEDAC Building Energy Specialist. Smart Energy Design Assistance Center (SEDAC), University of Illinois at Urbana Champaign

Union College Combined Cooling, Heat and Power Project

Turbine Inlet Cooling. A Valuable Tool to INCREASE Electric Energy Production

ST-4 Polygeneration plant. Parc de l Alba Cerdanyola del Vallès

ENERGY MANAGEMENT IN A CHILLED WATER PLANT USING THERMAL STORAGE

Héctor Rubio Plana Gas Natural, SDG S.A. 18th. June 2009

Microturbine CHP for Microgrids Microgrid2017

Gas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings

Modeling and analyzing solar cooling systems in Polysun

Providing free cooling from low temperature waste heat

CHP 201: Commercial & Critical Facilities

24th World Gas Conference ARGENTINA WOC 5.1: Industrial Utilisation CHP - Sharing on Gas District Cooling (GDC) in Malaysia

Absorption Chillers in Commerce

REPORT ON THE BENEFITS OF ICE- BASED THERMAL STORAGE FOR DISTRICT COOLING IN THE UAE MARKETS

Doc. CEN/TC 228 N541 CEN/TC 228

Economics of Cogeneration

DIRECTIONAL-BORE GROUND SOURCE HEAT PUMP FIELD REPORT

REPORT DOCUMENTATION PAGE

Chapter 9: Applications of the Laws of Thermodynamics

Syllabus Cogeneration: Definition, Need, Application, Advantages, Classification, Saving potentials

Packaged AHR (Advanced Heat Recovery) Systems for Engines, Gas Turbines, & Industrial Waste Heat. Tom Pierson

Workshop Industrial application of SOFC systems: the DEMOSOFC project

DISTRICT HEATING & HEAT NETWORKS PRESENTATION

Cogeneration in a Hospital: a case Study

ANNUAL ENERGY PERFORMANCE OF SOLAR THERMAL SYSTEMS IN BRAŞOV, ROMANIA

Carbon Reduction and Energy Optimization Strategy for one NHS Trust

2. TECHNICAL DESCRIPTION OF THE PROJECT

WAKE TECHNICAL COMMUNITY COLLEGE SUSTAINABLE ENERGY PLAN. Energy Plan

John S. Andrepont, President The Cool Solutions Company. ECOSTOCK 2006 Absecon, New Jersey, U.S.A. - June 1, 2006

Reducing Peak Energy Demand: The Hidden Benefit of Cool Roofs

TransPacific Energy Advantage: Case Studies

Absorption Chillers in Industry

SorTech package solution description

Overview of cogeneration technology and application

Combined Heat & Power An Overview

Sea Water Heat Pump Project

CONDENSING TEMPERATURE CONTROL THROUGH ENERGY MANAGEMENT SYSTEM SIMULATON FOR A LARGE OFFICE BUILDING

Heating the University of Glasgow with river sourced heat pumps. Adam McConkey Andrew Poon-King Zhibin Yu

The Project for renovation to increase the efficient use in Brewery by NEDO at Bia Thanh Hoa Brewery in Vietnam

Value of Air Source Heat Pumps in Light of Variable Energy Prices. Jeff Haase. Energy Design Conference February 27, 2013

a comparative study of secondary glycol and direct expansion refrigeration systems

Central Chiller Plants

OPTIMIZATION OF ICE THERMAL STORAGE SYSTEM DESIGN FOR HVAC SYSTEMS

Advanced Solar Thermal (AST) SOLID Energy, Inc.

District Cooling Sustainable Design. Presented by George Berbari CEO of DC PRO Engineering

Microgeneration Installation Standard : MCS 024 SOLAR DOMESTIC HOT WATER ENERGY CALCULATION. to be used in conjunction with MIS 3001:

Roadmap to Distributed Generation: Innovative Tools for CHP Adoption Sam Witty, Gita Subramony, ERS

District Energy Combined Heat and Power as a Resource

Advantages of Financing Continuous Commissioning As An Energy Conservation Retrofit Measure

Arrow Linen: CHP Washes Away Energy Costs of Commercial Laundry

Efficient utilization of energy sources

Natural Gas and Gas Turbines: Clean, Efficient and Flexible Energy. Mike Welch, Industry Marketing Manager O&G Siemens Industrial Turbomachinery Ltd.

Thomas F. Edgar University of Texas-Austin NSF Workshop on Shale Gas Monetization Montgomery, TX, March 27, 2014

ENERGY EFFICIENT SYSTEMS Recover & recycle your waste heat

The answer is... yes!

IRP 101. Intro to Integrated Resource Planning. Scott Benson Manager, Resource & Transmission Planning. March 23, 2017

Rank. Rank Technology.

Gregory W. Stevens and Ronald K. Ishii, Alternative Energy Systems Consulting, Inc.

Egypt: Small Scale Cogeneration

Electric Forward Market Report

Solar-Thermal Feasibility Study Farm #5 Boutique Winery

Solar Power Realities

8Combined Cooling, Heating and Power Technologies (CHP): An Overview

Chilled Water Energy Savings Study

Waste Heat Recovery as an Alternative Energy Source

Life cycle analysis of thermosyphon solar water heaters

Knowledge is Power Belimo Energy Valve CHW DELTA T MITIGATION STUDY AHR Expo Innovation Award Winner in the Category of Building Automation

Commercial Combined Heat & Power (CHP) Available via Fully Serviced Free to Fit, Cash, Leasing or Finance

BUILDINGS & OFFICE SPACES INDUSTRIAL SOLUTIONS. Combined production of Heat and Power. Waste Heat Recovery Bottoming Cycle

Gas vs. Diesel Generator Sets Performance Cost & Application Differences

SOLAR COOLING: STATE OF THE ART, TECHNICAL ANALYSIS AND FIRSTS APPLICATIONS

Energy Efficient Solutions CES Energy Group Overview

6 Cost Analysis. Table 6.1 Initial System Costs

SIMULATION MODEL IN TRNSYS OF A SOLAR HOUSE FROM BRAŞOV, ROMANIA

9/13/2011. Mark Hanicits, Director of Facilities and Safety, MetroSouth Medical Center. Terry Malloy P.E., Cxa, Project Manager, Teng & Associates

COMBINED CYCLE OPPORTUNITIES FOR SMALL GAS TURBINES

Overview of Federal Technology Demonstration Programs. Technology Track. Tim Tetreault, CEM Program Manager ESTCP Energy and Water August 9, 2016

Hotels: Water and Energy

Assessing the Energy Efficiency and Emissions of a Vertical Closed-Loop Geothermal System at West Chester University

Digester Gas Utilization at SWRP Where Should the Biogas Go?

Transcription:

Development of the First Combined Heat and Power Plant in the Caribbean (CHP District Energy) Presented at the IDEA2016 107 th Annual Conference & Trade Show June 20-23, 2016 St. Paul, MN This paper will be presented by: Alfredo Colombano from Colombs Energy Colombs Energy 1

CEPM s Facts CONSORCIO ENERGETICO PUNTA CANA MACAO (CEPM), Is a privately owned electric utility company (InterEnergy subsidiary) engaged in generating, transmitting, and distributing electricity through two isolated integrated power systems serving the fast growing tourism-based Punta Cana-Bávaro and Bayahibe regions in the east of the Dominican Republic. Serves 60 hotels with approximately 35,000 rooms in these tourist destinations as well as approximately 20,000 commercial and residential customers. Company s installed capacity is 90 MWe with Wartsila and Hyundai diesel engines operated using HFO and purchases of 80 MWe. CEPM also supplies thermal energies (10,000 TR chilled water, hot water and steam), with sales of: 700 GWhe/year of electric energy, 200 GWhcw/year of chilled water, (56,867,000 Ton-hour) 65 GWhdhw/year of domestic hot water. 2

District energy systems produce steam, hot water or chilled water at a central plant. The steam, hot water or chilled water is then piped underground to individual buildings for space heating, domestic hot water heating and air conditioning. As a result, individual buildings served by a district energy system don't need their own boilers or furnaces, chillers or air conditioners. The district energy system does that work for them, providing valuable benefits including: Improved energy efficiency Enhanced environmental protection Fuel flexibility Ease of operation and maintenance Reliability Comfort and convenience for customers Decreased life-cycle costs Decreased building capital costs Improved architectural design flexibility What is a District Energy? 3

Energy - Efficiency Comparisons From: International District Energy Association (IDEA) From: International District Energy Association (IDEA) 4

Chilled Water production with Electric Chiller (Without Cogeneration) Indicative 10 MWe (40%) 8 MWe Electric Energy for Other Uses Electrical 10 MW (40%) Fuel Oil Energy HFO 25 MW (100%) 2 MWe Electric Energy for Chilled Water Plant Chilled Water 5 MWcw (1,421 RT) Chiller with electric compressor COP 2.5 5

Chilled Water Production with Absorption Chiller (With Cogeneration) 8 MWe (40%) Electric Energy for Other Uses Indicative Fuel Oil Energy HFO 20 MW (100%) 20% of reduction Electrical 8 MW (40%) Thermal 7 MW (35%) Total 15 MW (75%) 7 MWth (35%) Waste Heat Chilled Water 5 MWcw (1,421 RT) Absorption Chiiler COP 0.72 6

CEPM s CHP-District Energy Project Overview As part of the expansion of CEPM s services to an Energy Services Company (ESCO), our team developed the First CHP-District Energy system in the Caribbean. This system provides 5,000 TR of chilled water (using Absorption Chillers) and Domestic Hot Water (DHW) to Hotels located near to CEPM s power plant. Waste heat comes from the exhaust gases and cooling water (Jacket water, Oil Cooler, Intercooler) of Six Wartsila Diesel Engines 18V32 Vasa (6 MWe each) that consume Heavy Fuel Oil (HFO). The distance from the power plant and the different Hotels group is about 2.5 miles (4 kilometers), making the new hot water loop a viable installation process. 7

Hotels included in the Project 8

CEPM s CHP-District Energy Project Overview (cont.) Chilled water is provided by locally based absorption chillers and the heat exchanger used to produce DHW (Domestic Hot Water) for both chilled and domestic hot water were installed inside the hotels. The HTHW (High Temperature Hot Water) is produced in the power plant with a temperature of roughly 248 ºF (120 ºC). At the hotel this HTHW supplies the thermal energy to drive single stage absorption chiller units. The HTHW output after being used to provide chilled water via the absorption chillers is then connected to an additional set of heat exchangers to produce DHW, and the spent HTHW loop temp water is then sent back to the power plant with a temperature of +/- 158 ºF (70 ºC). 9

HT Cooling Water Circuit 195 ºF (91 ºC) Exhaust Gases 662 ºF (350 ºC) Operation Scheme of the Project Produce High temperature Hot Water (HTHW) 248 ºF (120ºC) with the residual energy from electricity generation using the HT circuit radiator and exhaust gases from engine units Wartsila. Distribute the High Temperature Hot Water (HTHW) through a piping network to the hotels in order to provide the required energy to produce Chilled water (ChW) and Domestic Hot Water (DHW) Produced in each of the hotels stations, the required Chilled Water (CW) and Domestic Hot Water (DHW). Absorption Chiller Plate Heat Exchanger kwh kwh One Station Plate Heat Exchanger Returning High Temperture Hot Water +/- 158 ºF (70 ºC) Absorption Chiller kwh Engine Radiator High Temperature Hot Water Supply 248 ºF (120 ºC) Plate Heat Exchanger kwh Four Stations Absorption Chiller Heat Recovery Unit kwh kwh kwh Wärtsilä Engine Chilled Water Supply Meter 44.6 ºF (7 ºC) kwh Domestic Hot Water Supply Meter 131 ºF (55 ºC) Plate Heat Exchanger One Station 10

CEPM s CHP-District Energy Project Overview (cont.) In this way a large delta T 90 ºF (50 ºC) can be effected by using the single loop to serve two purposes, first high quality heat to run the absorbers, and second the lower temperature resulting water out of the chillers used for all or part of domestic hot water generation. The key goal and advantage of this project is to recover waste heat from the operation of the existing diesel engines with an electric efficiency of 39.5%, and produce thermal energy which used to be wasted away and instead reuse part of it from the exhaust gases to create new economic value. Only about 16% of the heat is recoverable due to limitations imposed by the dew point of the exhaust gases when HFO with 2.5% Sulfur is used, about 25.2% on the cooling water which is only recoverable to the level of about 9.1%, and the remainder is low temperature water used via cooling water to dump heat, with roughly an additional 3% by radiation to the surrounding area. All of these are economically achieved, benefiting both the utility and large resorts, to say nothing of helping control costs to the other local customers (more and more local businesses and homes are connecting to this grid, some having had their own small generator systems, or connected to an adjacent 11 power source).

CEPM s CHP-District Energy Project Overview (cont.) The sole reason the power company would consider this type of additional new investment is that their system MWe load has been growing about 5% per year, so redeploying some electrical load into thermal does not really hurt their business economically, and the lower resulting lower utility costs to the resort hotels provides an economic incentive to those resorts to continue dealing with the utility, which otherwise the resorts would not have to. The overall approach utilized as a business case was to take over the operation and maintenance responsibility at the resorts for the chiller plants, including compressors, chilled water pumps, condenser water pumps, and cooling towers, as needed, and install new absorption chiller systems, and thermal heat recovery systems, so that in the end chilled water, and domestic hot water heat are being sold. The heating system was similar in that the existing boilers and pumps were taken over by the utility, so that burden was removed from the resorts. The actual system results are sold as thermal KWH to the owners. 12

CEPM s CHP-District Energy Project Overview (cont.) The existing electric chillers are still used in summer peaking via electronic remote dispatch since there is insufficient heat through the loop for such peaks, but again, it is not relevant to the owner anymore since they buy delivered results. The paper will present the overall issues, and provide an overview of the results from this implementation process. This project entailed several years of planning and budgeting, securing written long term agreements from enough customers (resorts) to get the project rolling, with the rest of the customers assumed to come aboard as new loads once they could see the facility in long term operation, as has occurred in other district heating projects in Europe and the USA. The project was completed in 30 months and has been in operation now for 3 years. 13

CHP-District Energy Building Blocks Diesel Engine or Heat Source Waste Heat Recovery Systems Waste Heat Transmission & Distribution Circuit Chilled Water Plant End Users (Hotels) Heat balance Waste Heat Quality (Combustion Gases & Cooling Water Temperatures) Type of Fuel WHRU Gas & Water side Corrosion Issues Combustion Gases Dew point Load and Temperature Control Water/Water Heat Exchanger High Temperature Hot Water Vs Steam Maximum pressures & Temperatures Circuit Pressurization Differential Temperature (Supply and Return) Variable Vs Constant Flow Electric Energy for Water Pumping Water Hammer & Pressure Surge Water Chemical Treatment Single Stage Vs Double Stage Absorption Chiller Electric Motor Driven Compressor Chiller Adsorption Chiller (future) Thermal Load Hourly Profile Electric Load Hourly Profile Thermal Base load Vs Peak Load Thermal Energy Storage? Thermal energy Billing meter 14

Schematic of CEPM CHP-District Energy (Cooling/DHW ) Diesel Engine or Heat Source Waste Heat Recovery System Waste Heat Transmission & Distribution Circuit Chilled Water Plant End Users (Hotels) Wartsila HT Cooling System 195.8ºF (91ºC) E - 1 EX3 EX2 248 ºF (120 ºC) Main Feeder Pumps Expansion Tank 158 ºF (70 ºC) Condenser Water Cooling Systems (Cooling Tower) COP = 0.70 Absorption Chiller 176 ºF (80 ºC) EX4 Chilled Water Systems Domestic Hot Water DHW 140 ºF (60 ºC) 122 ºF (50ºC) LT Cooling System HT Cooling System LT Cooling System Chilled Water (CW) Electric Driven Chiller Water Cooled 44.6 ºF (7 ºC) Electric Driven Chiller Air Cooled 15

Diesel Engine Energy Balance (HFO) Diesel Engine or Heat Source Notes: (*) Depends on the configuration of charge air coolers (One-stage or two-stage charge air cooler (**) Depends on the outlet temperature of exhaust gases from waste heat recovery boiler, limited by the Dew Point of the combustion gases (Sulfur %) Electric Energy 6,000 kwe (39.5%) 6,000 kwe (39.5%) Fuel Input HFO 15,190 kw (100%) Exhaust Gases 4,860 kw (32%) Cooling Water 3,832 kw (25.2%) Exhaust Gases Waste Heat Non Recoverable 2,430 kw (16%) 350 ºC/ 662 ºF) Exhaust Gases Waste Heat Recoverable 2,430 kw (16%) (**) 350 ºC/ 662 ºF) High Temperature Cooling Water 1,382 kw (9.1%) (*) (91 ºC/ 195 ºF) Low Temperature Cooling Water 2,450 kw (16.1%) (*) (50 ºC/122 ºF) 3,812 kw (25.2%) Radiation 455.7 kw (3.0%) 9,812 kw (64.7%) 16

Business Model Option 1 Produce High Temperature Hot Water (HTHW) 248 ºF (120ºC) Produce Chilled Water (CW) in power plant at CEPM 44.6 ºF (7ºC) 5,000 TR Distribute Chilled Water (CW) to the hotels Waste Heat Transmission & Distribution Circuit This option seems more expensive, because the temperature differential is only 9ºF (5ºC), which implies a large flow circulating (13,333 GPM) in the distribution net work and therefore larger pipe diameters (Diameters 24 to 30 inches) COP = 0.70 High Temperature Hot Water (HTHW) 248-176ºF (120-80ºC) 25,121 kwte 2,381 GPM Delta T = 72ºF (40ºC) Chilled Water 44.6-53.6ºF (7-12ºC) 5,000 TR 17,585 kwr 13,333 GPM Delta T = 9ºF (5ºC) 17

Business Model Option 2 Produce High Temperature Hot Water (HTHW) 248ºF (120ºC) Distribute High Temperature Hot Water 248ºF (120ºC) Produce Chilled Water (CW) 44.6ºF (7ºC) in each hotel 5,000 TR Produce Domestic Hot Water (DHW) 140 ºF (60ºC) in each hotel This option seems less expensive, because the temperature differential is 72ºF (40ºC), which implies a small flow circulating (2,198 GPM) in the distribution net work and smaller pipe diameters (Diameters 14 to 16 inches) COP = 0.70 COP = 0.70 Waste Heat Transmission & Distribution Circuit High Temperature Hot Water (HTHW) 248-158ºF (120-70ºC) 31,402 kwte (include 6,280 kwte for DHW) 2,381 GPM Delta T = 90ºF (50ºC) COP = 0.70 This option also allows to supply Domestic Hot Water to the hotels Chilled Water 44.6-53.6ºF (7-12ºC) 18

High Temperature Hot Water (HTHW) System Vs Steam System: Advantages of HTHW over steam heat distribution systems: Waste Heat Transmission & Distribution Circuit The amount of blow down required by a boiler depends on the amount and nature of the makeup water supplied. HTHW systems have closed circuits, require little makeup, therefore, practically never require blow down whereas steam systems commonly lose about 1% to 3 percent of the total boiler output because frequent blow downs are required. Operation within closed circuits permits reducing the size of water treating systems to a minimum Due to the heat storage capacity of HTHW systems (large mass of water), short peak loads may be absorbed from the accumulated heat in the system. The closed recirculation system reduces transmission and thermal losses to a minimum while practically eliminating corrosion and scaling of generators, heat transfer equipment, and piping. Both supply and return high temperature water piping can be run up or down and at various levels to suit the physical conditions of structures and contours of the ground between buildings without the problems of trapping and pumping condensate 19

CDD (ºF) Cooling Monthly Profile End Users (Hotels) The cooling load is highly correlated with the Cooling Degree Day CDD and in a hotel is also influenced by the room occupancy 900 800 700 600 500 400 300 200 100 Punta Cana Cooling Degree Day CDD 0 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 20

0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 20:00 21:00 22:00 23:00 Load kw Cooling Load Vs. DHW Load Hourly Profile End Users (Hotels) As shown there are two peaks in demand for DHW (red line) one at 8:00 and one at 18:00, these peaks do not coincide with the peak cooling demand therefore HTHW demand that drives the absorption chiller; in order to exploit the maximum of the thermal energy from HTHW circuit that leaves the absorption chillers to heat the DHW, tanks are used to store thermal energy during off peak hours. 1,600 1,400 1,200 Typical Hotel CW and DHW Load Profile 1,000 800 600 400 200 - Day's Hours CW Load (kw) DHW Load (kw) HTHW for Abs Chiller 21

The results of this project, from inception to date can be summarized as follows: Reduction of 25% of the electrical energy (kwh) consumed by the resorts versus the option of not doing cogeneration. This is primarily due to these group of customers consumed 34% of the electrical bill to produce chilled water before the district project energy was implemented. This implies that the utility company will consume 25% less fuel to supply electric power to these group of customers and can thus delay the expansion of electrical transmission and distribution networks. The base demand for chilled water of the resorts was covered by the new absorption chillers plus reuse of limited amount of existing peak cooling with the current older electric chillers. All demand for domestic hot water was supplied to the resorts group by the district energy, therefore fuel consumption in the domestic hot water boilers was reduced to effectively zero. This is very important given that all of these boilers were operated using Diesel or GLP, which is very expensive. 22

The results of this project, from inception to date can be summarized as follows (cont.): The overall COP of the systems with pumps, fans, compressors before was about 2.7, and the overall system after around COP=15 in winter, and about 7 or so for 365 days (due to the reuse of the older electric chillers for peaking purposes). The business case required that the resort owners sign long term contracts to insure the new cogen system loop and associated infrastructure could be appropriately amortized. This project demonstrated that you can use waste energy to produce thermal energies (chilled water and domestic hot water) required in the resorts for the comfort of its customers, in such a way that both the resorts benefit through total cost reduction as compared to the previous all electric load case, and the utility benefits as well through increasing overall company net revenues in a cost effective way which helps to cement a long term relationship with large key customers. This then becomes truly a win-win situation for all, which is one of the avowed goals of any third party cogeneration project. 23

Fuel Oil and Greenhouse Gas Emissions Reduction With this cogeneration approach, about 25% of thermal energy is recovered to drive absorption chillers and DWH heat exchangers and reduce the Fuel consumption by 35,740 Bbl/year of HFO and 32,881 Bbl/year of LPG. The Greenhouse gas emission is reduced by over 28,872 metric tons CO2/year. Greenhouse Gas emission reduction effects Chilled Water Production Absorption Chillers TR 5,000 Electric Chillers Displaced TR 5,000 Electric Chillers Displaced kwcw 17,585 Coefficient Of Performance (weighted) COP 6.0 Electric Power for Chillers Displaced kwe 2,931 Load Factor 0.95 Electric Energy for Chillers Displaced MWhe/year 24,390 GHG emission factor for HFO Power Generation tco2/mwhe 0.8084 Avoided CO2 emissions tco2/year 19,716 Avoided Fuel Oil (HFO) Bbl/year 35,740 Domestic Hot Water Production Domestic Hot Water Production displaced from boiler kwdhw 6,280 Load Factor 0.50 Domestic Hot Water Production displaced from boiler MWhdhw/year 27,506 GHG emission factor for LPG tco2/mwhdhw 0.3329 Avoided CO2 emissions tco2/year 9,158 Avoided Fuel (LPG) Bbl/year 32,881 Total Avoided CO2 emissions tco2/year 28,874 24

Questions? Alfredo Colombano BSIE, MBA, CEM, DGCP, REP Engineering Director Colombs Energy Houston, TX +1 281 686 2083 alfredo.colombano@usa.net Bruce K. Colburn PhD., P.E., CEM, DGCP Project Energy Efficiency Engineer EPS Capital Corp. +1 610 525 4438 bcolburn@epscapital.com Martin T. Anderson Energy Efficiency Engineering Manager EPS Capital Corp. +1 610 368 3703 manderson@epscapital.com 25