User s manual CONTENTS. Catalog # 6440FS. Technologies, Inc. TDR 100 Soil Moisture Meter. General Overview 2. Meter Operation 2. Meter Configuration 3

Similar documents
Using capacitance sensors to monitor soil moisture. Interpreting the numbers

Air. Water. Minerals (rocks)

Global Water Instrumentation, Inc.

HydroSense Soil Water Measurement System Revision: 7/10

Calibration and Evaluation of an Improved Low-Cost Soil Moisture Sensor

Calibration of Soil Moisture Measurement Using Pr2 Moisture Meter and Gravimetric-Based Approaches

SMEC 300 Soil Moisture, EC & Temperature Sensor PRODUCT MANUAL

Watermark Soil Moisture Sensor Catalog # 6450WD

Application Note. MadgeTech, Inc. (603) Phone (603) Fax 6 Warner Road Warner NH 03278

Irrigation Water Management and Scheduling

Water Budget IV: Soil Water Processes P = Q + ET + G + ΔS

Scientific registration n : 1368 Symposium n : 3 Presentation : poster. HASEGAWA Shuichi

Air. Water. Minerals (rocks)

Soil moisture measurements

AQUATERR I N S T R U M E N T S. M, T & EC -300 User s Manual

Lecture 6: Soil Water

Time Domain Reflectometry Soil Moisture Measurement for Hydrological Modelling

INSTRUCTION MANUAL. CS616 and CS625 Water Content Reflectometers Revision: 2/16. Copyright Campbell Scientific, Inc.

Overview. Learning Objectives: This module provides step-by-step instructions in how to do the Bulk Density Protocol.

Monitoring soil moisture. For more efficient irrigation

Soil Particle Density Protocol

Irrigation Management

DATA LOGGER Model DL-SA11

Soil moisture monitoring system (BUNPD)

Lesson 2 - Stationary Sensors (Part 2)

Irrigation. Presentation to. 14 January 2009, Amarillo, Texas Steve Evett

Measurement of soil physical properties

A s California s historic drought

Cross Borehole Electrical Resistivity Tomography (ERT) Measurements

HOBO Plug Load Logger (UX ) Manual

A study on the calibration and accuracy of the onestep

Model 10A. Model 20A. Operating Manual. ECG Simulator. ECG / Arrythmia Simulator

Soil moisture sensor sensitivity

TESTING SOIL CONDITIONS FOR VEHICLE SECURITY BARRIER TESTS

Alternatives of Low Cost Soil Moisture Monitoring Devices for Vegetable Production in South Miami-Dade County 1

Series 1500 Laminated Bellows Expansion Joints. Catalog 1103

Texture Definition: relative proportions of various sizes of individual soil particles USDA classifications Sand: mm Silt:

Temperature correction of substrate moisture measurements made in coir in. polytunnel-grown strawberries

Field Devices For Monitoring Soil Water Content 1

Moisture analyzers (moisture meters) FIZEPR-SW100

Model M120 Mini Temperature/Humidity Meter

SOIL MOISTURE METERS. Basic soil moisture meters

INSTRUCTION MANUAL DAFM3

OM-CP-QUADPROCESS 4-Channel Low Level DC Current Data Logger. OM-CP-OCTPROCESS 8-Channel Low Level DC Current Data Logger INSTRUCTION SHEET

Safety Precautions. 3. Cabinet Assembly 4. Operating buttons / functions.5-6. Machine Operation

TRENCHING AND EXCAVATION

OM-90 SERIES Portable Temperature and Humidity Data Loggers. Shop online at omega.com

Evaluation of Soil Moisture Sensors

DRS220. DRS220 Digital Refrigerant Scale Limited Warranty. Digital Refrigerant Scale

SWCC: Experimental results of copper tailings and spent ore

Accuracy and bias of TDR measurements in compacted sands

Interpretation of Soil Moisture Content to Determine Soil Field Capacity and Avoid Over Irrigation in Sandy Soils Using Soil Moisture Measurements

F-2000H HAY AND HOPS MOISTURE METER. OPERATION MANUAL v3.6 DELMHORST EUROPE TITANIUMLAAN 100 THE NETHERLANDS

HDI 2200 Choke Position Indicator

Model 292A. Surface Resistance Test Kit. Instruction Manual

MiniCD. User Manual. American Weigh Scales. MCD-100 (100 x 0.01g MCD-500 (500 x 0.1g)

Trenching & Shoring Safety Course Outline

Bottom Hinged Flood Barrier Operation & Maintenance Manual

TEMPORAL AND SPATIAL VARIATION OF SOIL WATER CONTENT MEASURED BY BOREHOLE GPR UNDER IRRIGATION AND DRAINAGE

Operational Manual. The Stevens pf Sensor Soil Matric Potential Probe Stevens Part #51133

Ultrasonic Load Monitoring

My Notes. Ka Hana Imi Na auao A Science Careers Curriculum Resource Go to: 1

PK-110. User Manual. American Weigh Scales. PK-110 (0-44lb x 0.05lb / lb x 0.1lb)

dronium TWO AP DRONE with camera

Smart Water Application Technologies (SWAT)

TABLE OF CONTENTS. 3.1 Specifications About EC

Soil Volume Change Meter (PVC)

NOTES TABLE OF CONTENTS

The use of different methods to evaluate soil volumetric water content. Submitted by Arjun Pandey. Oklahoma State University Plant and Soil Sciences

International Journal of Technical Research and Applications e Reynaldo Siahaan, Siwarak Unsiwilai, Boonchai Sangpetngam

EN Operating instructions

Section Fluid Applied Waterproofing

Waterproof Digital Refractometer , , , , , & Instruction Manual

LABORATORY 3 SOIL ANALYSIS

Development of digital moisture meter for jute fibre and its products

Irrigation Management in Alberta

Utility Cut Restoration

Model 5200 Cargo Lift Installation and Operation Manual

Quick Start TIME mode Set Time... 4 Set Alarm... 5

Series 5500 Bellows Pump Connectors Catalog 474E

DS-520 Digital Indicator Operation Manual 73366

Establishing Critical Protective Concentration Levels (PCLs) for Lead-Affected Soils

In Situ Probes for Measurement of Electrical Conductivity of Soilless Substrates: Effects of Temperature and Substrate Moisture Content

Fixed LCD TV/Monitor Mount 10" to 24" Installation Instructions

COATING THICKNESS MEASURING

Determination of Design Infiltration Rates for the Sizing of Infiltration based Green Infrastructure Facilities

PMA 31-G. English. Printed: Doc-Nr: PUB / / 000 / 00


Coating Thickness Gauge Model: AX-CTG10 User s Manual

Placement and Interpretation of Soil Moisture Sensors for Irrigated Cotton Production in Humid Regions SITE SELECTION IN A FIELD OBJECTIVE

CH88 In Situ Flue Gas Oxygen Transmitter

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Portable Hardness Tester NOVOTEST T-D1

Product Booklet Keen K-1000CS FCAW Wire Coil and TIG Filler Wire Storage Oven Floor Positioned

SECTION 1 STALOK FIBER FOR TURF PARKING / EVENT STAGING AND FIRE LANES

OPO-SHORT Installation Instructions Manual Version

AM1620 Precision Industrial Platinum Resistance Thermometer User s Guide

Universal Tilting TV Mount 32" to 60" Installation Instructions

Transcription:

User s manual Catalog # 6440FS CONTENTS General Overview 2 Meter Operation 2 Meter Configuration 3 Taking Measurements 4 Factors Affecting Measurements 4 TDR 100 Soil Moisture Meter Relative Water Content 5 Specifications 5 Appendix 1: Soil Moisture Guidelines 6 Warranty 6 This manual will familiarize you with the features and operation of your new Field Scout TM TDR 100 Soil Moisture Meter. Please read this manual thoroughly before using your instrument. For customer support, or to place an order, call Spectrum Technologies, Inc. at (800)248-8873 or (815) 436-4440 between 7:30 am and 5:30 p.m. CST, FAX at (815)436-4460, or E-Mail at info@specmeters.com. www.specmeters.com Spectrum Technologies, Inc. Spectrum Technologies, Inc at 23839 W Andrew Rd. Plainfield, IL 60544

General overview Thank you for purchasing the Field Scout TM TDR 100 Soil Moisture Meter. This manual describes the features and operation of the meter. ON Meter operation The ON switch turns the meter on and off. When the meter is turned on, it will display the battery status for 3 seconds. Soil moisture is a critical and, potentially highly variable component of the soil environment. Time-domain reflectometry is a proven technology for quickly and accurately determining volumetric water content in soil. The Field Scout allows the user to easily and rapidly take many measurements. Through the software the user can change the meter settings as well as program the logger to record relative water content at multiple sites. Battery at 75% Sample meter power-up and data screens The screen will then display the most recently used MODE screen (Volumetric or Relative water content). READ VWC= 28% PL=4.8in A= 26% N=03 Press the READ button to read the probe and update the screen values. The data point can be cleared from memory with the DELETE/CLR Delete Clr Avg MODE When the DELETE/CLR AVG button is pressed and immediately released, the last data point will be removed from the running average. Pressing and holding this button will reset the running average. The meter can be operated in either volumetric water content (VWC) or relative water content (RWC) mode. Press the MODE key to select the mode you are interested in. Note: To gather RWC data, the meter must already have the type programmed into it s memory with the software. The software is also used to select the rod length and unit system for water deficit calculations. 2 Refer to the Meter Configuration section (pg. 3) for more details on configuring the meter.

Meter Configuration The meter is configured with the software that accompanies the meter. The gray software cable connects the meter to the computer data port. The port in the meter is accessed by removing the meter s face plate. The port is located on the corner of the board opposite the side where the cable is connected to the probe. Use the Com Port button to select the port connected to the computer data port. The Download and Clear Memory buttons are not used with the TDR 100. Meter Configuration (Cont.) Meter Name: This feature is not important for the TDR 100. Probe Length: Check the box associated with the length of rod installed in the probe head. Deficit Units: When operating the meter in Relative Water Content mode, the meter will calculate and display the water deficit. Indicate whether these deficits should be displayed in inches or millimeters. Relative Water Content Set Points: Wet and dry volumetric water content set points can be programmed into the logger for 5 different locations or soil types. Each of these locations can be given a descriptive name of 5 characters. Default values for 5 common mineral soils (using permanent wilting point and field capacity as the set points) are set at the factory with new meters. Appendix 1 (pg. 6) lists general water-holding characteristics for several mineral soils. Refer to Relative Water Content (p. 5) for more details. Meter Settings The Meter Settings screen in the Field Scout TDR software is used to configure the meter for your specific application. The fields are described on the following page. 3

Taking Measurements The volumetric water content is the ratio of the volume of water in a given volume of soil to the total soil volume. At saturation, the volumetric water content (expressed as a percentage) will equal the percent pore space of the soil. The underlying principal of TDR involves measuring the travel time of an electromagnetic wave along a waveguide. The speed of the wave in soil is dependent on the bulk dielectric permittivity (ε) of the soil matrix. The fact that water (ε = 80) has a much greater dielectric constant than air (ε = 1) or soil solids (ε = 3-7) is exploited to determine the VWC of the soil. The VWC measured by TDR is an average over the length of the waveguide. Electronics in the TDR 100 generate and sense the return of a high energy signal that travels down and back, through the soil, along the waveguide composed of the two replaceable, stainless steel rods. The sampling volume is an elliptical cylinder that extends approximately 3 cm out from the rods. The high frequency signal information is then converted to volumetric water content. When taking a measurement, it is important that the rods be fully inserted into the soil. If not, part of the sampling volume will be composed of air and the reading will be inaccurately low. For the same reason, the probe should be inserted with a steady, downward pressure. If the rods are wiggled into the soil, air pockets can be created adjacent to the rods that will result in low readings. The probe should not be struck with a hammer or other blunt instrument as this can cause damage to the internal electronics. Also, care should be taken to ensure the rods are inserted as parallel to one another as possible. This will not have a large affect on the reading but will decrease the chances the rods will be bent or broken. Likewise, it is best to avoid areas with rocks or other material that can cause the rods to deflect or bend. Factors Affecting Measurements The TDR 100 senses changes in dielectric permittivity to measure volumetric water content (VWC). However, high amounts of clay (>30%) and high electrical conductivity (EC>2 ds/m) will attenuate the high-frequency signal and affect the reading displayed by the meter. Very high organic matter content will similarly affect the VWC reading. The meter will still respond to changes in water content. But, the internal equation that converts the electrical response to water content will not be identically applicable. In these cases, if an independent soil moisture content measurement is available, it is possible to generate a conversion from VWC measured by the meter to actual VWC. This is most easily accomplished by regressing one set of data against another. If the independent water content measurement is gravimetric (weight based) water content (GWC) rather than volumetric water content, some useful relations to keep in mind when doing the regression are: ( wet weight of soil -oven dry weight of soil) GWC = - oven dry weight of soil VWC = Volume of water in soil/ Total soil volume Bulk Density = oven dry weight of soil/total soil volume VWC = (GWC * Bulk Density)/Density of water 4

Relative water content RWC= 58% DEF=1.2in A= 61% N=06 PLFLD In addition to displaying volumetric water content, the meter can also display and record the relative water content (RWC) and Water Deficit (refer to Meter Operation, p. 3). RWC is an index value calculated with respect to upper (wet) and lower (dry) volumetric water content set points. The set points are configured with the software Meter Configuration section (pg. 4). An RWC of 0 indicates the soil is at the dry set point while an RWC of 100 indicates the soil has reached the wet set point. It is possible to get a negative RWC or an RWC greater than 100 if the soil s volumetric water content is outside the range of the set points. Measurement Units Percent volumetric water content Resolution 1.0% Accuracy Range Power Display Weight Specifications ±3.0% volumetric water content with electrical conductivity <2 ds m 1 and clay content < 30% 0% to saturation (Saturation is typically around 50% volumetric water) 4 AAA alkaline batteries Approximately 12 month life 16 character, 2 line LCD 1.5 lbs. (0.68 kg) The water deficit is the amount of rain or irrigation water necessary to raise the soil water content to the wet set point. This calculation applies to a soil depth equal to the probe rod length. The water deficit can be extrapolated further into the profile if the porosity and water-holding characteristics are similar to the volume of soil sampled by the probe. Probe Head Dimensions Rod Dimensions 4.1 x 2.8 x 0.7 (10.5cm x 7cm x 1.8cm) Length : 4.8 (12cm) or 7.9 (20cm) Diameter: 0.2 (0.5cm) Spacing: 1.3 (3.3cm) The meter s LCD screen displays data in two forms: Volumetric water content and Relative water content mode. 5

Appendix 1 Soil moisture Guideline The following table gives a general idea of the volumetric water content for various mineral soils at field capacity (FC) and permanent wilting point (PWP). The water holding characteristics and bulk density (ρ b ) of any given soil will not exactly match the tabulated values. Soil Type FC (%) PWP (%) ρ b (g/cm 3 ) Clay 44.3 21.7 1.3 Clay Loam 35.7 16.9 1.4 Loam 31.1 14.2 1.4 Loamy Sand 18.4 8.1 1.6 Sand 14.8 6.3 1.6 Sandy Clay 33.4 16.3 1.4 Sandy Clay Loam 29.4 14.0 1.5 Sandy Loam 21.3 9.5 1.5 Silt 38.4 17.2 1.2 Silty Clay 39.9 19.2 1.3 Silty Clay Loam 39.8 18.7 1.2 Silty Loam 35.3 16.0 1.3 Table A.1: Water holding capacities and bulk densities for selected mineral soils. (New Mexico Climate Center) Warranty The Field Scout TM TDR 100 Soil Moisture Meter is warranted to be free from defects in materials and workmanship for a period of 1 year from the date of original purchase. During the warranty period, Spectrum will, at its option, either repair or replace products that prove to be defective. This warranty is void if the product has been damaged by customer error or negligence, or if there has been an unauthorized modification. Returning Products to Spectrum Before returning a failed unit, you must obtain a Returned Goods Authorization (RGA) number from Spectrum. You must ship the product(s), properly packaged against further damage, back to Spectrum (at your expense) with the RGA number marked clearly on the outside of the package. Spectrum is not responsible for any package that is returned without a valid RGA number or for the loss of the package by any shipping company. Spectrum Technologies, Inc. 23839 W Andrew Rd Plainfield, IL 60544 (800) 248-8873 or (815) 436-4440 FAX: (815) 436-4460 E-Mail: info@specmeters.com www.specmeters.com 6