ConfoCor 3 Detection Module for Fluorescence Fluctuation Analysis

Similar documents
Microscopy from Carl Zeiss. DirectFRAP. News from the Cell. The New Class of Laser Manipulation for the Analysis of Cell Dynamics

F* techniques: FRAP, FLIP, FRET, FLIM,

Imaging & analysis with the LSM780 NLO Discover the secrets beyond the twilight zone

Rice/TCU REU on Computational Neuroscience. Fundamentals of Molecular Imaging

Confocal Microscopy Analyzes Cells

Spectral Separation of Multifluorescence Labels with the LSM 510 META

Performance of the Micro Photon Devices PDM 50CT SPAD detector with PicoQuant TCSPC systems

Thermo Scientific GENESYS 10S Bio spectrophotometer

DeltaPro. DeltaFlex FORENSICS PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Confocal Microscopy & Imaging Technology. Yan Wu

Confocal Microscopes. Evolution of Imaging

Time-resolved Measurements Using the Agilent Cary Eclipse Fluorescence Spectrophotometer A Versatile Instrument for Accurate Measurements

Innovations To Meet Your Needs

SpectraMax Multi-Mode Microplate Readers

The New Wave in Spectroscopy FS-2 FluoroMate Fluorescence Spectrometer

NIR Checkmaster Near-infrared spectroscopy On-line analysis of active ingredients during tablet production

Super Resolution Imaging Solution Provider. Imaging Future

HPCE-5 2. A Revolution in Capillary Electrophoresis. High Performance Capillary Electrophoresis

Confocal Microscopy of Electronic Devices. James Saczuk. Consumer Optical Electronics EE594 02/22/2000

Fluorescence Microscopy. Terms and concepts to know: 10/11/2011. Visible spectrum (of light) and energy

Sapphire. Biomolecular Imager THE NEXT GENERATION OF LASER-BASED IMAGING

Experts in Femtosecond Laser Technology. DermaInspect. Non-invasive multiphoton tomography of human skin

CyFlow Cube series Appealing from every angle

Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System

EDUCATION EXPERIMENT. Fluorescence of an Unknown Fluorophore. Introduction.

Advantages of Photodiode Array

UV MicroTime 200. Crossing the Border towards Deep UV Time-resolved Microscopy of Native Fluorophores

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions

The analysis of fluorescence microscopy images for FRET detection

Localization Microscopy

CyFlow Space Your flexible flow cytometer

CyFlow Space Your flexible flow cytometer

Cleaning Validation PRODUCT OVERVIEW

Fpollutant-free zero air for analytical

Measurement of surface concentration of fluorophores using. fluorescence fluctuation spectroscopy

BÜCHI Labortechnik AG

A Survey of Laser Types. Gas Lasers

ICP Expert software. Technical Overview. Introduction

AMAZINGLY CAPABLE REMARKABLY AFFORDABLE. Avio 200 ICP Optical Emission Spectrometer. For research use only. Not for use in diagnostic procedures.

Quantum Dot applications in Fluorescence Imaging for Calibration and Molecular Imaging

Azure cseries. A new way to see the light. c600 c500 c400 c300

Using the Pulsed Flame Photometric Detector (PFPD) for Low-level Analysis of Organophosphorus Pesticides

Introduction to N-STORM

NovoCyte Flow Cytometer

Basic Principles in Flow Cytometry. Flow Cytometry

XDS TM Multipurpose NIR-analyser for Laboratories

Surface Plasmon Resonance Analyzer

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

Fluorescence Imaging with One Nanometer Accuracy Lab

HiSeqTM 2000 Sequencing System

CEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy

BOD 21M Distance Sensors. Effortless performance High efficiency

Sub-micron scale patterning of fluorescent. silver nanoclusters using low-power laser

Simultaneous multi-color, multiphoton fluorophore excitation using dual-color fiber lasers

PERFORMANCE MADE EASY REAL-TIME PCR

Bi177 - Lecture 13 Microscopy Outside the Box. Fluorescence Nanoscopy TIRF 4-pi STED STORM/PALM

SNG High Performances Green Microchip Series

Laser Polymer Welding - No Limits for Colors

Prometheus Series Product Information

Application Note LCMS-87 Automated Acquisition and Analysis of Data for Monitoring Protein Conjugation by LC-MS Using BioPharma Compass

AURORA AIRY BEAM LIGHT SHEET IMAGING SYSTEM THE CUSTOM DEVELOPMENT PROGRAMME

SUPPLEMENTARY FIGURES

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

A quantitative protocol for intensity-based live cell FRET imaging.

Automated Imaging Assay for Characterizing Ca 2+ Flux with R-GECO Biosensor

A Comparison of PerkinElmer s LANCE camp Assay Performance to that of State of the Art Competitive Technologies

Low Energy Consumption, High-Speed Productivity LCG 3015 AJ. Fiber Laser Cutting System

Final exam. Please write your name on the exam and keep an ID card ready.

Picosecond Transient Absorption Spectroscopy System. picotas

Nodes of regulation in cellular systems

CBI Toolbox Tour 2015

Tracking Cellular Protein Localization and Movement in Cells with a Flexible Fluorescent Labeling Technology. Chad Zimprich January 2015

Melting Point M-565 Technical data sheet

Biomolecular Interaction Analytics using MicroScale Thermophoresis

A COMPARISON OF GAS ANALYSIS TECHNOLOGIES AVAILABLE FOR EFFICIENT AND SAFE COMBUSTION IN CONTROL FIRED HEATERS

PALM/STORM, BALM, STED

UV400 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

3D Transfection System

MetaXpress High-Content Image Acquisition and Analysis Software

Spectroscopy Fiber Optic Probes for In-line Analytical Analysis

Fabrication of Micro and Nano Structures in Glass using Ultrafast Lasers

Simple, intuitive and accessible MRI solution for preclinical research. M-Series Compact MRI Systems

Brochure. Equator gauging systems

Measuring on surfaces

GRAVOTECH GROUP FIBRE LASER. Complete range of integrable laser marking systems LASER SOLUTION F-SERIES.

Short Term Tender Notice

Greenhouse Gas Measurement Technology

Advanced Test Equipment Rentals ATEC (2832)

GRAVOTECH GROUP. Complete range of Integrable Fiber Laser Marking Solutions LASER SOLUTION F-SERIES.

BIO 315 Lab Exam I. Section #: Name:

Supporting Information to Carbon Nanodots Towards a Comprehensive Understanding of their Photoluminescence

Applicability of Hyperspectral Fluorescence Imaging to Mineral Sorting

MODEL 1051 TEM Mill ION MILLING. Ion milling is used on physical science. specimens to reduce thickness to electron

Biochemical Analysis The Lambda Series UV/Vis Spectroscopy

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

ICP-OES. Varian Vista-MPX CCD Simultaneous ICP-OES

Structural Biology. Single crystal X-ray diffraction and SAXS. Systems designed for structural biology

Workflow Spheroids: 3D tissue model in cancer research

Transcription:

Microscopy from Carl Zeiss ConfoCor 3 Detection Module for Fluorescence Fluctuation Analysis Focusing on Single Molecules We make it visible.

ConfoCor 3 Working in a World of Single Molecules Explaining diffusion processes and molecular interactions and their relation to cellular compartments and structures is essential in the detailed understanding of cell functions. In many cases it is not the average signal that is of interest but the behaviour of single molecules acting in an individual manner. Fluorescence-based assays at a single molecule level have revolutionised the way we can observe molecules at work in their natural surroundings. Many of these technologies are based on fluorescence fluctuation analysis (FFA) and include fluorescence correlation spectroscopy (FCS). The new ConfoCor 3 Detection Module is much more than an imaging device. It not only allows you to observe single molecules non-invasively but also to resolve fast dynamic processes with great accuracy. To cap it all, fully automatic, computer-controlled routines mean it is also easy to use.

Milestones of the FCS Technology in Bioscience Carl Zeiss has played a pioneering role in FCS. By working closely with leading scientists, we have repeatedly achieved significant breakthroughs and continue to devote significant resources to maintaining our market leadership in this field. Just some of many milestones in FCS: 1903 M. von Smoluchovski explains the interrelation between auto-correlation and Brownian movement. 1972 First fluorescence correlation spectrometers developed in the labs of Cornell University, Ithaca, USA and at Max Planck Institute in Göttingen, Germany. 1988 First confocal instrument using a microscope set up for FCS measurements developed at Karolinska Institute in Stockholm, Sweden. 1996 Carl Zeiss introduces the world s first automated fluorescence correlation spectrometer, the ConfoCor 1. 1999 Carl Zeiss sets the standard for fully automated dual-channel cross-correlation spectrometry with the ConfoCor 2. 2000 The age of biophysics dawns in cell biology with the ConfoCor 2/LSM 510 META, an innovative module that makes an ingenious technology available to a wide range of users. 2005 Carl Zeiss introduces the ConfoCor 3, a module tailor-made for observing live cell processes through its direct attachment to a channel of the LSM detection module.

Ideal for Sensitive Imaging and Fluctuation Analysis Combine the ConfoCor 3 with a microscope from LSM 5 Family and you have the ideal symbiosis for sensitive imaging and fluctuation analysis. This combination of fast detectors and online data analysis enables you to resolve ultra-fast dynamic processes. The choice of APD or GaAsP gives you the greatest possible flexibility in balancing the requirements of maximum sensitivity and time resolution. Sites of interest can be easily spotted, marked and approached with great precision by the laser beam in a sequential manner. These are just some of the features that make the ConfoCor 3 a unique and fully automated sensor for studying mobile molecules, even at a single-molecule level. The ConfoCor 3 from Carl Zeiss a new benchmark in fluorescence fluctuation analysis. 2

ConfoCor 3 3

Features You Care about Your Specimen, We Take Care of the Technology The ConfoCor 3 works like an extended arm of the LSM 510 in quantitatively investigating cellular processes. Just image your cell, select your measurement position and the system will provide you with all the parameters of interest in real time. Nothing could be easier. Great precision The scanning mirrors of the LSM 510 are used for precise positioning. Just take your image and point to your site of interest. Pixel-precise positioning allows you to target even sub-cellular structures. Ultra-sensitivity No need to compromise on sensitivity with the ConfoCor 3. You can follow the fate of single molecules in time and space. Spectral resolution Two well-balanced channels make efficient dualcolour experiments possible. Experience cross-correlation at its best in combination with the new family of C-Apochromat objectives. Convenient reproducibility Since all measurement tasks can be automated, you can define repeated measurements at different locations. As a result, you can look forward to significantly improved statistics. Bleaching a spot into a dye layer using the ConfoCor 3 shows you pixel-precise positioning. 4

1 2 Selection of measurement positions inside the nuclei of two HepG2 cells expressing an EGFP fusion protein of HNP1. Up to 99 consecutively approached positions can be defined in three dimensions. Multiple measurements can be triggered at each selected position. Specimen: P. Hemmerich, IMB Jena, Germany 4 5 3 G (t) 2.0 1.8 1.6 Hybridisation of a Rhodamine Green-labelled, single-stranded DNA molecule with a twofold excess of a Cy5-tagged complementary strand and determination of interaction efficiencies by dual-colour cross-correlation. Displayed are the two auto-correlation (blue and red) and the cross-correlation (black) functions. 1.4 1.2 1.0 1 10 100 1000 10000 100000 1e + 006 1e + 007 Time (µs) G (t) 2.0 1.8 1.6 1.4 Improving statistical significance. Consecutive correlation measurements can be easily averaged to obtain correlation functions with a better signal-to-noise ratio. Note that the averaged curve in yellow, in the example the average of 10 measurements, bears less noise than one single measurement displayed in red. 1.2 1.0 1 10 100 1000 10000 100000 1e + 006 Time (µs) 5

Applications We Take You Beyond Pure Imaging, You Delve Deeper into Cells Fluorescence correlation spectroscopy (FCS) is a proven and powerful technology that enables you to gain new insights into dynamic cellular processes. The intrinsic read-out parameters diffusion time, coincidence and concentration of molecules and calibration-free measurements make FCS the ideal tool for quantitative analysis of the concentration, location, interaction and mobility of molecules. Investigating molecule distribution in cells The local concentration of proteins is responsible for triggering a variety of cellular events. The uptake efficiency of carrier molecules determines their usefulness in the delivery of cargo. Protein gradients represent growth clues. FCS can give you all the numbers you need for a quantitative description of such systems. Looking at diffusion in different ways The underlying principles of diffusion processes in cells may vary a lot. FRAP (Fluorescence Redistribution After Photobleaching) and FCS give you different perspectives on these processes. FRAP reveals long-distance relationships while FCS supplies you with the diffusion at the specific position of observation and can provide insights into underlying principles. Quantifying the cytoplasmic release of the fluoresceinlabelled AntpHD cell-penetrating peptide. Recent data implicate endocytosis followed by release into the cytoplasm as the mechanism of entry. Specimen: T. Waizenegger, R. Fischer, R. Brock, University of Tuebingen, Germany Studying protein complex formations Integrating proteins into complexes may inhibit or activate protein functions. If you are interested in quantitatively linking changes in complex formation with activity, FCS is the ideal method. Detecting common movement Vesicles are the transport entities in cells delivering proteins into different compartments. Toxins, however, may take advantage of these pathways. If you want to determine the state at which sub-units separate and wreak havoc in the cell, just follow their fate with FCS. Quantifying receptor ligand interactions Binding ligands to their cognate receptors triggers off signal transduction pathways. Pharmaceutical drugs are often antagonists or agonists that interfere with or boost cellular responses. If you want to find out more about binding strengths, FCS is the technology you need. 6

0s 1s 2s 0s 1s 2s 3s 0s 1s 2s 3s A B C D E F Pre-bleach Post-bleach GFP H2B- GFP GFP-RB FRAP time series in the nucleus of Rat-1 cells expressing GFP, H2B-GFP (histone H2B), and GFP-RB. A 2.9 µm x 2.9 µm area of the nucleus was photobleached for 0.688 sec with 100% transmission of 488 nm light from an argon laser. Images shown on the figure: pre-bleach (A and B, the white box in A represents the bleach region), immediately following the bleach (C), and at 1, 2, and 3 seconds post-bleach (D, E, and F, respectively). The colour code in images B-F indicates pixel intensity. Fluorescence recovery after photobleaching of egfp (green), egfp-wtrb (red), egfp-mutrb (blue), and egfp-h2b (lilac) in the nucleus of Rat-1 cells. The mean of at least 20 experiments +/- standard deviation is always shown. Relative fluorescent density shown in per cent. Normalized auto-correlation curves describing the behavior of egfp (green), egfp-wtrb (red), and egfp-mutrb (blue) in the nucleus of Rat-1 cells. Specimen: S.P. Angus, D.A. Solomon, R.F. Henigan, E.S. Knidsen, University of Cincinnati, US RFI / % egfp egfp-wtrb egfp-mutrb time / s Correlation G (τ) Correlation G (τ) Intracellular crosscorrelation between A and B sub-units of endosomally localised cholera toxin in live cells. Loss of intracellular cross-correlation between A and B subunits of cholera toxin on separation in the GOLGI also note their different diffusion characteristics. Specimen: K. Bacia, P. Schwille, Technical University Dresden, Germany 7

8

9

Software Still Analysing or Already Publishing? The ConfoCor 3 comes with a software that not only enables you to control the detection module but also makes a convenient analysis of measurement data possible. You can choose single measurements or software-controlled multi-measurements. Autocorrelation and cross-correlation are calculated in real time at the same time as the current measurement. And you can opt to have the raw data for individual analysis. All these functions are distinguished by an automated ease of use that takes the time-consuming effort out of data analysis. The basic software module provides you with all the necessary tools to analyse freely moving molecules. But you can also opt for advanced software modules that: Incorporate the most common methods (free diffusion, anomalous diffusion and flow) and provide for user-defined models Allow for global and interactive fitting with the possibility of defining start values and boundaries Provide for photo counting histograms. Automated routines ensure you enjoy maximum reproducibility and statistical significance. And if all this is not enough, you can simply take the raw data and analyse them in any way you want. Graphical interfaces for defining models (above) and programming routine tasks (right) 10

Data analysis All data are acquired simultaneously. Name Description Acquisition Calculation Display Analysis Auto-correlation Analysis of interactions 1 or 2 channels Multiple tau Autocorrelation Number of molecules, One partner labelled algorithm curve 2 diffusion times, 2 fractions, Differentiation by diffusion properties triplet time / fraction Cross-correlation Analysis of interactions 2 channels Multiple tau Cross-correlation Number of molecules, Two partners labelled algorithm curve diffusion times Differentiation by diffusion properties Biophysical models Free diffusion model including triplet transitions and up to three components: G(τ) = 1 + T -τ 1 T e -τ τ T N ( M i = 1 yi )+ (1 + τ τ Di ) 1 + τ 1 τ Di 1 S 2 Parameter Description User-selectable values G(τ) Correlation function - τ Correlation time - T Fractional population of triplet state Included / not included τ T Decay time of triplet state Yes / no, depending on T N Average number of fluorescent molecules Result of fit in the detection volume M Number of fluorescent components 1, 2, 3 y i Contribution of i-th fluorescent component M Result of fit y i = 1 i = 1 τ Di Translational diffusion time of i-th fluorescent component Result of fit S Structure parameter describing length Result of fit vs. diameter of confocal volume S = ω 2 ω1 ω 1, ω 2 Distance from centre of beam focus in radial and axial directions at which the collected fluorescence intensity has dropped by a factor of e 2 compared to its peak value for Gaussian beam profile. Fitting routine Marquardt algorithm, a non-linear least-square algorithm using χ 2 criterion. 11

Specification Don t Miss those Short-lived Moments The flexible modular design of the ConfoCor 3 allows you to adapt the system to your specific needs. Perfect interplay between the ConfoCor 3 and the LSM 510 turns the system into a fully integrated imaging and spectroscopy platform. An objective of unmatched performance delivers high resolution images. And the system s compact design minimises light paths for even greater sensitivity. The ConfoCor 3 module is directly attached to the channel 4 port of the LSM 510 (META) detection head. There are two detector types to choose from: APDs (avalanche photodiodes) or GaAsP PMTs (gallium arsenide phosphide photomultiplier tubes) for highest sensitivity and time resolution. New real-time electronics allows for fast data transport and processing. And in combination with the new generation of C-Apochromat objectives, the system is very suitable for dual-colour cross-correlation measurements. Filter wheels for advanced configuration Major beam splitter 24 Position Type 1 NT 80/20 2 HFT 488/561/633 3 HFT KP 700/488 4 HFT KP 700/561 5 HFT 458/514 6 HFT 458/561/633 7 HFT 488/561 8 HFT KP 650 IR-block filter wheel Position Type 1 BG 39* 2 none 3 KP 680 IR* 4 Block 5 KP 610 IR* 6 Block 7 KP 575 IR* 8 Block Secondary beam splitter Position Type 1 NFT 490* 2 NFT 500 3 NFT 515* 4 NFT 545 5 NFT 565 6 NFT 590* 7 NFT 600 8 NFT 635 9 NFT KP 545* 10 NT 50/50 11 AP (plate) 12 Mirror *Light shaded filters are not included in the basic configuration Emission filter 1 Position Type 1 LP 470* 2 LP 505* 3 BP 505-540 IR* 4 BP 530-575 IR* 5 BP 530-610 IR 6 BP 560-610 IR 7 LP 530 8 BP 580-610 IR 9 LP 580 10 BP 615-680 IR 11 BP 655-710 IR 12 LP 655 13 KP 680 IR* 14 KP 610 IR* 15 KP 575 IR* 16 Block Emission filter 2 Position Type 1 BP 375-445 IR* 2 BP 420-475 IR* 3 BP 470-495 IR 4 LP 470 5 BP 470-540 IR* 6 BP 470-610 IR* 7 BP 505-540 IR 8 BP 505-610 IR 9 LP 505 10 BP 530-610 IR 11 LP 530 12 LP 580 13 LP 655* 14 KP 680 IR* 15 KP 610 IR* 16 Block 12

The detectors that go with the ConfoCor 3 module: APD (right) and GaAsP (left). Microscope Stand Z drive nosepiece Z drive Piezo Inverted Microscope Axiovert 200 M Coarse & fine z-focus; minimal step size of 50 nm; travel range 10 mm Travel range closed loop 250 µm; 70 steps / sec.; resolution 0.75 nm; step size & repeatability 5 nm Laser module Lasers Dampening Shutters and Filters Ar-Laser (458/477/488/514 nm, 30 mw); HeNe Laser (633 nm, 5 mw); HeNe Laser (543 nm, 1 mw), or a DSSP Laser (561 nm, 10 mw). Optional: HeNe Laser (594 nm, 2 mw); NLO, UV Ar-Laser (80 mw) oder 405 nm Diode Laser (30 mw) 10-, 100- and 1,000-fold higher suppression of laser light by AOTF Line filters in front of the Argon laser and shutters in front of the HeNe and DSSP lasers efficiently suppress any unused laser light Electronics module System control System computer Control of Microscope, laser modules, scan modules and other accessory equipment; control of data exchange and synchronisation by real-time system. Data exchange between real-time system and host computer via gigabit Ethernet interface High-end PC with extensive RAM and HD space, ergonomic high-resolution TFT flat screens, numerous accessories, OS Windows XP, multi-user environment Detectors APD GaAsP detectors Fibre-coupled, actively quenched avalanche photodiodes; sensitivity of detector for VIS range: 50 75% (dependent on wavelength); dark count rate: < 250 khz; dead time: 50 ns (corresponding to 20 MHz time resolution for counted photons); pulse width: 35 ns; total After-pulse (100 500 ns): 0.3% Direct coupled, cooled gallium arsenide phosphide photmultiplier tubes; sensitivity of detector for VIS range: 35 50% (depending on wavelength); transit time spread (TTS) 280 ps; FWHM of pulse < 25 ps Pinhole One pinhole motorised from channel 4, adjustable in x,y; z-position can be optimised by collimator setting; xy travelling range as projected into sample space: 7.57 µm; xy step size as projected to sample space: 15 nm Software LSM 510 ConfoCor 3 Basic software plus options including Physiology, MultipleTime Series, Image VisArt, Deconvolution, 3D for LSM, Kinetics, FRET, Visual Macro Editor Basic software plus options including Extended Models, Global and Interactive Fit, and Photon Counting Histogram Lasers Type Wavelength Power UV Ar Ion 351/364 nm 80 mw Diode 405 nm 30 mw Ar Ion, multiline 458/477/488/514 nm 30 mw 45 mw He-Ne 543 nm 1 mw DSSP 561 nm 10 mw HeNe 594 nm 3 mw HeNe 633 nm 5 mw 13

n System Overview ConfoCor 3 Laser module RGB (458, 477, 488, 514, 543/561, 594, 633 nm) Laser Enterprise II 653 (80 mw, 351 nm, 364 nm) UV Laser module ConfoCor 3 VIS, VIS/UV, VIS/NLO or VIS/405 scan module LSM 510 NLO kit for direct coupling Upgrade kits LSM 510 to LSM 510 META Laser module V (with output coupling) VIS, VIS/UV, VIS/NLO or VIS/405 scan module LSM 510 META Option: Fiber decoupling channel 4 Fluorescence Correlation Spectrosccopy (FCS) System electronic rack Plug-in unit for external laser System table with breadboard Wide: 1000x750mm (1200x950 overall) 16:10 flat screen monitor 24" LCD TFT flat screen monitor 19" 14 System table with active absorption width 1800 mm, height 750 mm, depth 1400 mm System table with active absorption width 1200 mm, height 750 mm, depth 1000 mm Control computer

1:1 PIEZO objective focus 100 HAL illuminator with collector Halogen lamp 12 V 100 W Switching mirror mot Scanning stage DC 120x100 with mounting frame for inverted stand Transmitted-light channel for LSM 5 100 HAL illuminator with collector Halogen lamp 12 V 100 W Detection module external PMT for Non Descanned Detection Motor control MCU 28 2-axes control panel Non Descanned Detection kit motorized NDD module with shutter Detection module external PMT for Non Descanned Detection ConfoCor 3 Axiovert 200 M SP Several solutions for incubation will be offered. HBO 100 illuminator with lamp mount and collector HBO 100 illuminator self-adjusting, with lamp mount and collector Power supply unit for HBO 100 FluoArc variable intensity lamp control for HBO 100 X-Cite 120 fiber coupled illuminator Detection module external PMT for Non Descanned Detection VIS, VIS/UV, VIS/NLO or VIS/405 scan module LSM 510 or LSM 510 META AxioCam HRm AxioCam HRc AxioCam MRm Non Descanned Detection kit motorized NDD module with shutter 15

ConfoCor 3 US Patent: 659223 LSM 510 META US Patents: 6403332, 6750036, 6858852, 6747737 German Patents: 19915137C2, 10038526B4 For further information, please contact: Carl Zeiss Advanced Imaging Microscopy 07740 Jena, Germany Phone: +49 36 41-64 34 00 Fax: +493641-643144 E-Mail: micro@zeiss.de www.zeiss.de/fcs Subject to change. Printed on environment-friendly paper, bleached without the use of chlorine. 45-0057 e/10.05