MIGRATION OF INTRA-OCULAR FOREIGN BODIES*

Similar documents
CORNEA INTO RABBIT CORNEA*

Intravitreal and sub-retinal injections of plasmid DNA and electroporation in P0 pups

Start with ME. LEAVE A LEGACY OF EXCELLENT OUTCOMES WITH PEACE OF MIND. TECNIS MONOFOCAL IOL WITH TECNIS itec PRELOADED DELIVERY SYSTEM

The IVIS Suite is an integrated ensemble of hardware and software devices, individually named Precisio, pmetrics, Cipta, Clat, RoMa and Ires.

Development of Veinseal

ROUTINE SPECIMEN COLLECTION BY SPECIMEN TYPE

Build With VICTUS. Build Your Patient Offerings. Build Your Premium Practice.

Chapter 15 Extrusion and Drawing of Metals

Design of Semi gravity Retaining Walls

INDEX METALS FERRIC METALS NON-FERRIC METALS WORKING WITH METALS METAL FORMING TECHNIQUES ENVIRONMENTAL IMPACT OF METAL EXTRACTION

EXPERIENCES WITH A HEAVY DUTY SHREDDER

Build With VICTUS. Build Your Patient Offerings. Build Your Premium Practice.

M. C. Yaksh, Ph.D., PE NAC International T. Chung SAIC

Falk WRAPflex Couplings Failure Analysis

MECHANICAL AND PHYSICAL PROPRIETIES

Cavity Wall Ties. Survey & Repair Summary. Brief History

S.No Description Unit Quantity Rate (Rs) Amount (Rs)

SKIN INFECTION OF RABBITS WITH HEMOLYTIC STREP- TOCOCCI ISOLATED FROM A PATIENT WITH ERYSIPELAS.

The Kirkendall effect

Symposium INTERNATIONAL SCIENTIFIC SYMPOSIUM: WHAT S NEW IN REFRACTIVE EYE SURGERY

Introduction to Longwall Mining and Subsidence

Design for Forging. Forging processes. Typical characteristics and applications

Corrosion Control and Cathodic Protection Data Sheet

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )

CW 3550 Chain Link and Drift Control Fence TABLE OF CONTENTS

ISO Ophthalmic optics Contact lenses and contact lens care products Guidance for clinical investigations

FLUOROPHOTOMETRIC APPARATUS FOR

To ensure success, this work was carried out in three phases. At first, the electrical-thermal process associated

RapidPort EZ Port Applier DIRECTIONS FOR USE (DFU)

CHAPTER 2 ABRASIVE WATER JET MACHINING

Laser Cataract Refractive Surgery. Robert Maloney, MD

Roughneck Mesh Slings

MANUFACTURING PROCESSES

Nonlinear Models of Reinforced and Post-tensioned Concrete Beams

1 Exam Prep Placing Reinforcing Bars Tabs and Highlights

News & Articles. Designing Inclined Screw Conveyors for Industrial Applications. History of Screw Conveyors

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE

Technical Notes 24G - The Contemporary Bearing Wall - Detailing [Dec. 1968] (Reissued Feb. 1987) INTRODUCTION

Instructions For Use 1stQ Basis IOL - Preloaded

Draft Indian Standard Galvanized Steel Sheets (Plain and Corrugated)- Specification (Seventh Revision of IS 277) ICS

GREEN THREAD Piping Systems

2

GAS METAL ARC WELDING (GMAW)

Heavy Rib. Page 1 of 6. Expanded Mesh & Metal Products. Key Product Features:

Optimizing Strain Gage Excitation Levels

FE Review Mechanics of Materials

AMETAL AMETAL AMETAL APPLICATIONS GENERAL

ITEM 404 DRIVING STEEL PILING

1. METALS 2. FERRIC METALS 3. NON-FERRIC METALS 4. WORKING WITH METALS 5. METAL FORMING TECHNIQUES 6. ENVIRONMENTAL IMPACT OF METAL EXTRACTION

WeldingAL-6XN. General Welding Recommendations

Administrative Changes

SECTION HANGERS AND SUPPORTS FOR PLUMBING

HOT ROLLED STEEL FLAT PRODUCTS FOR STRUCTURAL FORMING AND FLANGING PURPOSES SPECIFICATION (Third Revision of IS 5986)

A simple, low-cost method was developed to collect, transport and

YARWAY HANCOCK CONTINUOUS BLOWDOWN GLOBE VALVE SERIES 5505

Tungsten Carbide Rotary Burrs

BEARING CAPACITY OF SHALLOW FOUNDATIONS

The Bernoulli Filter

Minimally Invasive Glaucoma Surgical Procedures: Should I Incorporate Them Into My Practice?

Electric and Magnetic Forces

Ferrography A procedure for measuring wear rate

SPECIFICATIONS FOR THE CONSTRUCTION OF NEW PASSENGER EQUIPMENT CARS PREFACE

ISO INTERNATIONAL STANDARD. Resistance welding Spot welding of aluminium and aluminium alloys Weldability, welding and testing

Titanium Welding Technology

Engineering Materials 2

The lattice parameters and interplanar spacings of some artificially prepared melilites.

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Visual testing of fusion-welded joints

Metal extrusion. Metal stamping

The New Incremental Launching Construction Technology of Jiubao Bridge Long-span Hybrid Arch-girder Structure

. NOTES ON THE TEST OF A BUTT-WELD IN A 24in. x Min. x 1001b. ROLLED STEEL JOIST

Forging. Types of forging process. 1. Open Die Forgings or Hand forgings. Lecture Notes on Manufacturing Process

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES

fischer Test Report Fixing Tests for Bison Hollow Core Slabs

Quality Control Procedures.

5. POST-EARTHQUAKE INSPECTION

Insertion of Skin Tunnelled Central Venous Catheter (STC)

Functional FOLDS BY JONATHAN L. BAYREUTHER, PE, AND JONATHAN HAMANN

TRIZ-BASED TOOLS FOR KNOWLEDGE CREATION

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

Weld Imperfections and Preventive Measures

Ferrous Alloys. Metal Alloys. Ferrous. Non ferrous. Grey iron. Carbon Low Alloy High Alloy. Nodular iron White iron Malleable iron Alloy cast irons


fischer Test Report Fixing Tests for

Unit Automobile Body Repair Techniques 6006 Shrinking Sheet Metal Student Manual

Module 3 Selection of Manufacturing Processes. IIT Bombay

Quality Standard for ACR Copper Tubes in LWC

BIS or used as Amendment to STANDARD comments is 15 Nov. 2008

The concept of statical determinacy

TORSION SIMPLIFIED: A FAILURE PLANE MODEL FOR DESIGN OF SPANDREL BEAMS

Magnets. Contact the National Museum of the U.S. Navy for Field Trip and School Visit opportunities!

Bulk Deformation Processes

Bending number of paperboard (Reaffirmation of T 495 cm-03) (no changes from Draft 1)

COASTAL BRITISH COLUMBIA 17

Marina Bay Sands Hotel Arch 631 Kayla Brittany Maria Michelle

The 1985 Corvette manufactured by General Motors contained a beam in the

Microstructure and texture of asymmetrically rolled aluminium and titanium after deformation and recrystallization

New Continuous Chromatography Options

5.4 Analysis for Torsion

The Nuts & Bolts of Tree Felling

Transcription:

Brit. J. Ophthal. (1956) 40, 173. MIGRATION OF INTRA-OCULAR FOREIGN BODIES* BY C. G. TULLOH Moorfields, Westminster and Central Eye Hospital, London THE migration of an intra-ocular foreign body, with or without its subsequent spontaneous extrusion from the eye, has been reported several times in the literature, though in few instances in any detail. It was first described by de Castelnau (1842), who recorded how a man sustained an injury to his right eye, followed, 3j years later, by the spontaneous extrusion through the cornea of a particle of iron measuring 13 mm. x 5 mm., and weighing 750 mg. His treatment of the eye during recurrent periods of inflammation while the foreign body was retained included cold compresses, leeches, and belladonna. Copper particles, however, are the most frequently concerned in this phenomenon. De Wecker (1896) noted a case in which, immediately after an injury, a foreign body was seen ophthalmoscopically in the right fundus near the macula. At the end of 4 weeks it was seen in the lower part of the vitreous, and its life-history, although complicated by the removal of a secondary cataract, was terminated only after it had perforated the iris and cornea some 4j years later. Blake (1931), the only writer to give details of an accurate x-ray localization, reported two cases, in each of which a piece of copper-wire migrated forwards; in the first, a piece of wire 3i mm. long moved in the course of 5 years from a position " 5 mm. behind the cornea" to the limbus in the six o'clock meridian; in the second, a piece of wire 5 x 2 x 2 mm. moved from a position " 4 mm. below the horizontal, 5 mm. to the temporal side of the vertical plane, and 10 mm. behind the cornea ", to the limbus, again in the six o'clock meridian. This latter case, however, was operated on unsuccessfully, when the foreign body was seen to be pushing the iris forwards, so that its history was not straightforward. Other cases in which migration followed by extrusion occurred between 1 and 5 years after injury have been noted by Kipp (1884), Rampoldi (1891), Meyer (1894), Hoesch (1895) and Erb (1899). A 7 to 10 year delay was reported by Hartley (1883) and Spechtenhauser (1894), 18 years by Lewis (1897), and 21 years by Raulin (1897). Kiiummell (1908) reported a case in which a copper particle weighing 2 75 mg. and measuring 1-6 x 13 x '85 mm. moved from the upper posterior part of the globe until it caused the iris to bulge forwards; an iridectomy including the foreign body was performed, with a satisfactory result. Received for publication August 16, 1955. 173

_ ~~~~~~~~x-ray 174 C. G. TULLOH The migration and extrusion of iron particles have been reported by Gesang (1905) and Scalinci (1905), of glass by Azarova (1943) and Gandolfi (1947), of wood by Bochever (1947), and of a lead pellet by Wicherkiewicz (1904). Case Report A male brass-worker, aged 49 years, was admitted to hospital on December 23, 1952. History.-lO days previously he had been re- +K Zt}z,, <>^ > \t X\- moving a short pipe from a cylinder block. The A 7 ia rx r ;_titmpipe Z_ was D composed of an alloy with a high copper {'i>igm p N) \1 v ri I content, and this was being struck by an engineer's hammer and a sharp cross-cut steel chisel, instead of the usual blunt-ended tool known as a " drift". ewhile at work he felt something strike the right eye and, as the presence of an intra-ocular foreign body was not suspected at first, he was treated " _ s s > > i _ Fer< ;{: _ merely for a corneal abrasion, but after a few days the eye became painful and the vision blurred, So he was referred to hospital. L Examination.-On admission, the left eye showed no abnormality, with a visual acuity of 6/6. The right eye had a visual acuity of 6/24 AZ A Yl,,' IN unaided. There was a 3-mm. linear perforating jaa_n T"Kcorneal i wound in the 9.30 meridian, 3 mm. from I/ I/ A." koll-ii-q r\i\ V) and parallel to the limbus. There was a localized I I IUI 11 111 i-tiklq j j jj jlens opacity at 9.30, partly obscured by a posterior }1W\M\M 14%i'y8vyI/i4/}A},synechia. The vitreous and fundus showed no abnormality, and the tension was normal. X-ray localization revealed the presence of a radioopaque foreign body in the region of the pars plana of the ciliary body of the right eye, 9 mm.!',4,i.'s-14,,, JIJ i to the temporal side of the vertical corneal axis, Zt1fIT ll I II 1 1 1 8 rmm deep to the plane tangential to the centre of the anterior surface of the cornea, with its ntre 3 *2 mm. below the horizontal corneal axis and(figst and 2a). 41 9G x Operation24i12o52. Undernlocalanaesthesia ll0lyyvi N5 xk x the io lateral o rectus was mobdy, d and a scleral FIGI-XraloaIzation chart incison made 8 mm. from the limbus, 2 mm. right kl eye, al9sw inita1 a fn was i bu nhg af dst I,hN ii 1 below the mid-line. Repeated magnetappllcations 3ilvoliLlllllllll produced no result, so the wound was closed 5' and the eye allowed to settle down. Further 4 localization showed no change in the posit.on of the foreign body, and an attempt was 9_ ~~~~~~~~made to remove it under direct vision. 11> - ~~~Operation-30/11/53.-A scleral flap was pre- 14 ~~~~~~~~pared and turned back on the temporal side over F1G. I.-X-ray localization charts for the site of the foreign body. The ciliary body right eye, showing initial and final was incised, but nothing was found, so the (1) Initial position- 23/12/52. wound was closed. There was some vitreous (2) Final position-26/3/55. loss.

MIGRATION OF INTRA-OCULAR FOREIGN BODIES (a) 7/1/53. (b) 11/9/54. FIG. 2.-X rays (lateral view) showing different appearances of foreign body indicating movement. The eye then settled down again, there were no further attempts at removal, and the patient was discharged on 8/2/53. However, the local lens opacities and also a posterior cortical cataract developed gradually, and there were recurrent attacks of iritis (and hypopyon) necessitating admission for a week in September, 1954. At that time a further x ray was taken, revealing that the foreign body had altered its position (Fig. 2b). When the patient was seen on 25/3/55 at a routine visit, it was noticed that there was a dark spot 1 J mm. behind the limbus (c) 26/3/55. in the 5.30 meridian, and that this was the foreign body embedded in and showing thro,ugh the sclera was confirmed by x ray (Figs 1 and 2c). By this time the visual acuity had become reduced to " hand movements ", and a mature cataract had developed in a lens slightly displaced backwards below. There was a mild uveitis, and the tension was slightly reduced. Operation-26/3/55.-Under local anaesthesia a conjunctival flap was fashioned, and turned back, and a 3-mm. scleral incision was made over the point of the foreign body, which was withdrawn with forceps and the wound closed. It was found to have been lying almost horizontally, with one end embedded in the sclera in the 5.30 meridian, 1 mm. behind the limbus, and the other in the inferior angle of the anterior chamber in the 7 o'clock meridian. 175

176 C. G. TULLOH Nature and Route of Foreign Body.-The particle was examined in detail and found to be attracted only very feebly to the giant magnet. It was triangular in cross section at its centre, tapering to a point at both ends, and measured 4 1l x I -25 x -1 16 mm. (Fig. 3). It weighed 6-96 mg. and analysis showed its composition to be: copper 60-2 per cent. and zinc 39 7 per cent., i.e. 60/40 brass. In its passage forwards it could have travelled by one of three routes. Having pierced the pars plana, it may have moved forwards in the suprachoroidal space, traversed the ligamentum pectinatum, and then entered the angle 1pwIuIiI_~ of the anterior chamber, or it may have travelled along the surface of the ciliary body and then through the zonule and the root of the iris, or it may have passed through the whole thickness of the ciliary body before entering the anterior chamber, though this last is unlikely., FIG. 3.-Foreign body. Discussion The factors concerned in the migration and extrusion of intra-ocular foreign bodies, and of copper particles in particular, will be noted under four headings: Size and Shape.-These have been said to have little influence on the tendency of a foreign body to migrate (Blake, 1931), but one would suggest that the opposite is, in fact, the case, for 80 pe'r cent. of copper particles which migrate are long and narrow, with pointed ends and a transverse diameter of 2 mm. or less. It must be admitted that, although they have a similar shape, glass and iron foreign bodies very rarely migrate. In the case of glass, however, the inactive chemical nature of silicates in the eye is the predominant factor, and in the case of iron, the relatively mild inflammatory reaction it produces compared with copper, again on account of its chemical nature, together with the fact that most iron foreign bodies are removed within a short time of their entering the eye, are two factors which greatly reduce the likelihood of such a particle migrating. Chemical Nature.-Although only about 4 per cent. of intra-ocular foreign bodies are composed of copper, two-thirds of those which migrate contain this metal. It is said that, if copper is present in the form of an alloy containing less than 85 per cent. of the metal, chalcosis tends to occur, whilst, if it is present in relatively pure form, a violent purulent reaction ensues. Leber (1892) first drew attention to this fact in his experimental investigations, wherein he introduced lead, copper, and other metals into the eye, and observed their effects. In the present case, however, although the copper content was only 60 2 per cent., the reaction, while doubtless controlled by treatment, was mainly purulent in type. It is this marked inflammatory reaction which is partly responsible for the migration and eventual extrusion of copper foreign bodies as compared with other types. Magnetic Properties.-The fact that copper foreign bodies are not ferro-magnetic renders their extraction difficult, so that many are retained. This will increase the proportion of copper amongst other types of migrating particles. Direction ofmovement.-this is always forwards and, in four-fifths of the cases, downwards also. The latter is clearly due to gravity, since, in the waking hours at least, this force will act towards the lower part of the eye-ball, whilst the former is

MIGRATION OF INTRA-OCULAR FOREIGN BODIES related to the reaction of the ocular tissues. In other parts of the body, any foreign material will always pass towards a surface, whether the skin (externally) or a body cavity (internally), and this is due to the inflammatory reaction produced around it softening the adjacent tissues, associated with tissue tension, which will drive the foreign body outwards towards a free surface. In the eye the same holds good, the tension of the orbital tissues, together with the intra-ocular pressure, tending to move the foreign body forwards. Occasionally, a particle will migrate to its original entry wound. This is rare, but has been attributed to the contraction of fibrous tissue which has formed along its entry path, pulling it forwards; a more probable explanation is that the entry path is preferentially softened by the inflammatory reaction, thus producing a line of least resistance, along which the particle will travel. Other reasons which have been adduced for the forward migration of foreign bodies are the compression of the globe by the extra-ocular muscles, the pull of the ciliary muscle on the choroid during accommodation, and the intra-ocular fluid currents. The first of these may play some part by increasing the intra-ocular pressure, but the other two are clearly somewhat fanciful. Summary A case is described of the migration of an intra-ocular foreign body composed largely of copper. A summary of the previous literature on the subject is given, together with an explanation of the phenomenon. My thanks are due to Mr. J. G. Milner for permission to publish this case. REFERENCES AZAROVA, N. S. (1943). Vesin. Oftal., 22, No. 1, p. 38. BLAKE, E. M. (1931). Amer. J. Ophthal., 14, 1009. BOCHEVER, I. M. (1947). Vestn. Oftal., 26, No. 6, p. 36. CASTELNAU,-. DE (1842). Arch. gin. mid., 3 ser., 15, 210. ERB. A. (1899). Z. Augenheilk., 1, 449. GANDOLFI, C. (1947). Atti Soc. oftal. Lombarda. 2, 328. GESANG, B. (1905). Wien. klin. Wschr., 18, 110. HARTLEY, A. T. (1883). Brit. nzed. J., 2, 71. HOESCH, W. (1895). Inaug. Diss. WVurzburg. Kipp, C. J. (1884). Amer. J. Ophthal., 1, 103. KUMMELL, R. (1908). Z. Augenheilk., 19. 36. LEBER, T. (1892). Trans. ophthal. Soc. U.K, 12, 1. LEWIS, G. (1897). Zbl. prakt. Autgenheilk., 21, 553. MEYER, 0. (1894). VIII Intemat. Congr. Ophthal. Edinb., p. 48. RAMPOLDI, R. (1891). Ann. Ottal., 20, 538. RAULIN, J. F. (1897). Ann. Oculist. (Paris), 117, 287. SCALINCI, N. (1905). Progr. Oftal., 1, 106. SPECHTENHAUSER, 0. (1894). Wien. klin. Wschr., 7, 810. WECKER, L. DE (1896). Progr. mid. (Paris), 3 ser., 4, 153. WICHERKIEWICZ (1904). Klin. Mbl. Augenheilk., 42 (2), 559. 177