Airborne Particle Detection

Similar documents
THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.

COLow COHigh COLow/H 2 NO 2 CO 2 H 2 S SO 2 C X H Y LANCOM 4. Portable Flue Gas Monitoring. comp NO NOx

Joint Committee Issue Paper

Compact flue gas analyser: testo 300 M-I

ASEPTIC BIOPHARMACEUTICAL MANUFACTURING: FAQs

MODEL 3340 LASER AEROSOL SPECTROMETER

testo 320. Combustion analysis in HD High Def & Heavy Duty For Residential & Commercial Applications 1

The Leader in Performance Indoor Air Quality Measurements

+ IQ/OQ Protocol Installation Qualification/ Operation Qualification

UNDER SECRETARY FOR HEALTH S INFORMATION LETTER MICROBIOLOGICAL ASSESSMENT OF PHARMACEUTICAL CLEANROOMS

Using the PPM2 Portable Trace Moisture Transmitter

Data Logging Solutions from Lascar Electronics

UniGas Hand-held combustion gas analyzer with 4 sensors

testo 330 Flue gas analysis with increased convenience and safety

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

Measuring Indoor Air Quality presented to AAFAME Members Nov. 14, 2017

HEPAfine. ULPAfine. HEPA Filtration Products. High Efficiency Particulate Air Filters for your most demanding applications

October 14, Subject Property: Terramar Elementary School 7000 West Happy Valley Road Peoria, Arizona PO#

Using UPSMON-PRO Monitoring Software. Opening UPSMON-PRO Monitoring Software

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Dekati. ELPI Electrical Low Pressure Impactor. Real-time particle size distribution Wide particle size range Wide range of applications

TWIN LASER PARTICLE COUNTER

FFU-HE High Efficiency Fan Filter Unit

The Basics of HVAC Filters and Savings

ENVIRONMENTAL SAMPLING

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Model FDL 115 Safety drying chambers for limited quantities of solvent

Camfil Farr truly practices the think globally - act locally concept.

SECTION AIR DUCT CLEANING

Model BF 260 Incubators Avantgarde.Line with forced convection

MONAIR. Recirculating Fume Cabinet. Low cost, efficient and State-of-the-art design. Reliability and safety assured

Breathing Air Purifiers BAP SERIES

Universal Bottle Sampler

TARGAS-1. Portable Photosynthesis System. Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring

AIRBORNE PARTICULATE MATTER WITHIN 100 RANDOMLY SELECTED OFFICE BUILDINGS IN THE UNITED STATES (BASE)

AIR MEASUREMENT INSTRUMENTS TSI-ALNOR 2014 CATALOG

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

Model BF 720 Incubators Avantgarde.Line with forced convection

Line Filters Solid, simple, smart. Advanced reliability in compressed air. TECHNOLOGY YOU CAN TRUST

SUMMARY OF OUR FINDINGS

Instruction Manual. for. gskin U-Value Kit

testo 340 Speed, power & precision in industrial combustion analysis.

testo 175-T1 testo 175-T2 1 channel temperature logger with internal sensor 2 channel temperature logger with internal sensor/external probe socket

MPM 100 Monitor Product Description Guide

PAO Compatible eptfe Technology HEPA Filters for Cleanroom Pharmaceutical Applications

Professional. Live Telephony Statistics for Informed Decisions

3M Occupational Health & Environmental Safety Division 3M EVM Environmental Monitoring Series. and Gas. Concentration Measurement

New Measurement Engineering For Monitoring Emissions In Industry

Just a few clicks away from a heating system

OZONE REMOVAL BY CHARCOAL FILTERS AFTER CONTINUOUS EXTENSIVE USE (5 TO 8 YEARS)

Online Gas Analyzer / Monitor

Multifunction HVAC and IAQ Meter

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

PARTICULATE CONCENTRATION AND AIR QUALITY MONITORING IN ONE ADVANCED INSTRUMENT

Ductless Fume Cabinets & Hoods

September 18, 204. Subject Property: Terramar Elementary School 7000 West Happy Valley Road Peoria, Arizona 85383

User Manual. Network Pro Series Tower and Rack-Mount Convertible UPS. Table of Contents 1000/1500/2200/3000

MICROBIO BIOAEROSOL SAMPLING

In the last few years, the concerns about global

YORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM

HAZ-SCANNER. Model HIM Complete Air Monitoring Station

Update to ASHRAE Ventilation Standards. William P. Bahnfleth, PhD, PE, FASHRAE, FASME The Pennsylvania State University University Park, PA, USA

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

Instruction Manual. for. gskin U-Value Kit

FIDAS FINE DUST MONITORING SYSTEMS. Fidas the world s only certified optical fine dust measurement system with single particle analysis for PM 2.

92831 TEL: (714) FAX:

Chemcap Clearview is ideal for the safety conscious laboratory

Inscale Measurement Technology Ltd Tel: Fax:

Humidity/temperature measuring instrument

Line filters LINE FILTERS

Cleveland COMBI OVEN-STEAMER Options & Accessories

Multipoint Sampling for AMC Monitoring. Version 01. Rev 01.

REFERENCE MEASURING INSTRUMENT

PocketBrowser. The Enterprise Mobility Developer Kit for browser-based applications

gskin Instruction Manual gskin U-Value Kit for Status: 15th Dec greenteg AG Technoparkstrasse Zürich, Switzerland

Compounding Aseptic Isolators (CAI) James T Wagner

Flue gas analyzer for industry

Milli-Q Reference Water Purification System

AFS 8D / 16D Degassed Water Purification Systems

XSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual

ICP Expert software. Technical Overview. Introduction

Steps in Conducting Structural Vapor Intrusion Potential Evaluations Under the Inactive Hazardous Sites Branch 13 February 2017

Coating Thickness Meter Data Sheet / Instructions

Best Selection for Your Business. Electronic Pricing Scale. User s Manual. (Model: TP-31)

The new testo 330 LL visualizes measurement data graphically

Instruction Manual Dräger MSI EM200-s

Thermo Scientific Biological Safety Cabinets Product Selection Guide

General Specifications for HVAC System Cleaning

Assessment of Containment and Product Protection In a Class II Type B3 Biological Safety Cabinet Under As-used Laboratory Conditions

Instruction Manual. gskin U-Value Kit. for. 1 / 7 gskin U-Value KIT: Instruction Manual. Status: 28 th October greenteg AG Technoparkstrasse 1

Quality of air is quality of life

GreenLine 6000 GreenLine 8000

Highly efficient flue gas analyzer

SPECIAL REPORT REMODELING DUST: It s More Dangerous Than You Think. Commissioned by

SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM

Combustion Laboratory Unit C492

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Low Energy Consumption, High-Speed Productivity LCG 3015 AJ. Fiber Laser Cutting System

ACCESS CONTROL AND WORK AREA SETUP RCT STUDY GUIDE State responsibilities in using or initiating a RWP.

Transcription:

Airborne Particle Detection Detects airborne particles from 0.3 to 5 µm Monitor 6 particle sizes simultaneously Choose from two models: Pro for normal environments CR for cleanrooms and clean areas Data logging to PC and Palm OS computers

ParticleScan : Advanced Airborne Particle Detection Made Easy Airborne particles consist of a mixture of solid matter and liquid droplets. Quantifying the concentration of particles in indoor air can give important information about: Air quality in terms of particles Pollutant sources Effectiveness of pollution control measures Real-Time Particle Measurement ParticleScan instruments use laser technology to measure particle concentrations in ambient air. The instruments continuously measure the concentration of airborne particles and display an updated reading every six seconds on the easy to read LED display. This enables the user to monitor particle concentration changes as they occur and allows individual pollution sources to be tracked down by using the ParticleScan as a particle sniffer. High Sensitivity ParticleScan instruments can identify single particles, making them far more sensitive than photometers, which identify only particle clouds. Particle Sizing ParticleScan instruments not only count particles they also categorise particles into six size groups ranging from 0.3 microns to 5 microns. This sizing information allows users to focus only on those particle sizes of interest, disregarding the rest. Data Logging to PC or Palm OS devices Every ParticleScan is supplied with software and a transfer cable which allows data logging to PC or Palm OS computers. Separate Models for IAQ & Cleanroom Use Two ParticleScan models are available: The ParticleScan Pro has been designed for IAQ measurements in normal indoor and outdoor environments. It can handle concentrations from 10 thousand to over 20 million particles ( 0.3µm) per cubic foot. The ParticleScan CR has been designed for cleanrooms or and other controlled environments with particle concentrations between zero and 2 million particles ( 0.3µm) per cubic foot. Audible Alarm Function The instrument allows the user to set an individual particle concentration threshold for each individual size channel. An intermittent beeping sound alerts the user should the set threshold be exceeded. Evaluate Air Cleaning Performance The ParticleScan Pro allows you to evaluate the efficiency of air filters and air cleaning equipment for particulate contaminants. By taking readings at the air intake and the air outlet of a filtration system, you are able to calculate the true particle removal efficiency of the system: % Efficiency=1- Particle count at air outlet x 100 Particle count at air intake Improving Indoor Air Quality Begin by mapping the areas of concern and recording the relative particle levels in each area. Make sure to include areas with both acceptable and unacceptable indoor air quality along with outdoor reference levels. In areas with the highest particle concentration, use the Particle Scan to locate the particle source and take corrective steps. Once remediation is complete, go on to areas with the next highest particle levels and repeat the process. Actual size

The ParticleScan Kit Polypropylene Carrying Case for superior protection in the field ParticleScan Pro/CR incl. NiMH rechargeable battery pack ParticleTrak Software for data logging onto PC and Palm AC Power Adapter & Battery Recharger Calibration Certificate Serial Cable for data transfer to PC Purge Filter for zero count calibration Instruction Manual Isokinetic Probe for accurate sampling Serial Adapter for data transfer to Palm OS

ParticleScan Comparison Chart ParticleScan Pro Description ParticleScan CR Advanced laser particle counter for the quick and accurate measurement of airborne particle concentrations in normal and polluted indoor and outdoor environments. Advanced laser particle counter with a flow rate of 0.1 cfm for the fast and accurate measurement of airborne particle concentrations in controlled environments and cleanrooms. Applications Monitor indoor & outdoor particle concentrations Verify particle levels in cleanrooms Log air pollution levels for reporting & record keeping Monitor laminar flow benches & clean air cabinets Demonstrate & compare filter efficiency of air & vacuum cleaners Test HEPA & ULPA filters for efficiency & leakage Track down particulate pollution sources Track down particulate contamination sources Evaluate effectiveness of pollution control measures Evaluate effectiveness of contamination control measures Inspect HVAC equipment & ducting Log air contamination levels for reporting & record keeping Spot-check particulate pollution levels at the workplace Analyse logged data for remedial action Analyse logged data for remedial action Store, organise, analyse & print data in spreadsheets Store, organise, analyse & print data in spreadsheets Display & communicate air pollution levels effectively in graphs Display & communicate air pollution levels effectively in graphs Flow rate: 0.025 cfm (0.7075 l/min) Exhaust air: not filtered Technical Specifications Weight: 1.9 lbs. (850 g) Warranty: 1 year (parts and labour) Flow rate: 0.1 cfm (2.83 l/min) Exhaust air: HEPA-filtered Minimum sensitivity: 0.3 µm (microns) 6 cumulative size channels: 0.3 / 0.5 / 0.7 / 1.0 / 3.0 / 5.0 µm (user selectable) 5 differential size channels: 0.3-0.5 / 0.5-0.7 / 0.7-1.0 / 1.0-3.0 / 3.0-5.0 µm (user selectable) Sample time: 6 seconds (continuous with no delay time) Readout volume units: particles/cu.ft. or particles/litre (user-selectable) Readout: 8-digit LED Laser source: 680 nm laser diode Count update: every 6 seconds NiMH rechargeable battery: up to 5 hours operation Audible alarm function: programmable for each cumulative size channel Computer interface: RS 232 Dimensions (LxWxD): 8 x 4 x 2.2 inches (205 x 103 x 57 mm) Supplied Accessories Transport case for field use Isokinetic probe for accurate sampling Purge filter for cleaning & zero calibration Mains power adaptor / NiMH battery charger (115V/60Hz or 230V/50Hz) CD-ROM with ParticleTrak software for data logging onto PC and Palm PC serial cable for data transfer to PC Palm serial adaptor for data transfer to Palm OS hand-held computers Instruction manual Calibration certificate System Requirements for Data Logging PC: Microsoft Windows 3.0/95/98/NT/Me/XP; CD-ROM drive; available 9 or 25 pin COM port, Microsoft Excel 97 or later Hand-held computers: Palm OS 3.0 or later All technical specifications are subject to change without prior notice. ParticleScan and ParticleTrak are trademarks of the IQAir Group. All other trademarks and registered trademarks, such as Excel and Palm OS, are the property of their respective owners.

Report No.: 0032 Compiled by: L. Armstrong Company: Armstrong PLC Date: 11 June 2002 ParticleTrak Software Real-Time Data Transfer to PC... With the supplied ParticleTrak software it s easy to turn your ParticleScan into a continuous data logging device to monitor airborne particle concentrations over time. The software allows particle counts for all six size channels to be stored on your PC. Laboratory HEPA System (Downtime Analysis) Timestamp >0.3 >0.5 >0.7 >1.0 >3.0 >5.0 Model Unit Location 14:44:51 3545 523 395 212 169 14 Pro per liter Lab 12 / HEPA System on 14:45:51 3164 424 311 184 141 14 Pro per liter Lab 12 / HEPA System on 14:46:51 2458 339 240 141 113 14 Pro per liter Lab 12 / HEPA System on 14:47:51 2994 410 282 155 127 14 Pro per liter Lab 12 / HEPA System on 14:48:51 2684 395 282 169 141 14 Pro per liter Lab 12 / HEPA System on 14:49:51 2486 367 240 141 127 14 Pro per liter Lab 12 / HEPA System off 14:50:51 2302 297 212 127 113 14 Pro per liter Lab 12 / HEPA System off 14:51:51 5367 862 579 325 254 14 Pro per liter Lab 12 / HEPA System off 14:52:51 6610 1102 819 480 381 28 Pro per liter Lab 12 / HEPA System off 14:53:51 6469 1003 849 424 339 28 Pro per liter Lab 12 / HEPA System on 14:54:51 6099 1219 879 339 268 28 Pro per liter Lab 12 / HEPA System on 14:55:51 6802 749 523 311 254 14 Pro per liter Lab 12 / HEPA System on 14:56:51 4280 607 438 240 198 14 Pro per liter Lab 12 / HEPA System on 14:57:51 4181 621 410 226 184 14 Pro per liter Lab 12 / HEPA System on 14:58:51 3404 508 353 184 141 14 Pro per liter Lab 12 / HEPA System on 14:59:51 3305 466 339 184 155 14 Pro per liter Lab 12 / HEPA System on 15:00:51 2684 353 226 141 113 14 Pro per liter Lab 12 / HEPA System on 15:01:51 2712 367 254 141 99 14 7000 Pro per liter Lab 12 / HEPA System on 15:02:51 2500 367 240 141 113 14 Pro per liter Lab 12 / HEPA System on 15:03:51 2599 353 254 127 99 14 Pro per liter Lab 12 / HEPA System on 15:04:51 1977 268 184 99 85 0 Pro per liter Lab 12 / HEPA System on 6000 15:05:51 2712 367 254 141 99 14 Pro per liter Lab 12 / HEPA System on 15:06:52 1879 254 198 99 71 0 Pro per liter Lab 12 / HEPA System on 15:07:52 1963 254 155 99 71 14 Pro per liter Lab 12 / HEPA System on 15:08:52 1921 254 169 99 85 0 5000 Pro per liter Lab 12 / HEPA System on 15:09:52 1879 254 198 99 71 0 Pro per liter Lab 12 / HEPA System on 15:10:52 1554 184 127 85 56 0 Pro per liter Lab 12 / HEPA System on 4000 3000 2000 1000 0 14:38:24 14:52:48 15:07:12 15:21:36 Graph >0.3 [per liter] 15:36:00...for Graphic Display and Reporting 15:50:24 16:04:48 16:19:12 16:33:36 The ParticleTrak program logs the data directly into an Excel spreadsheet. Once the particle concentrations are recorded, the data can be organised, analysed, documented and printed for reports. The pre-programmed Excel graphs enable you to create descriptive reports for effective client presentations. Data logging to Palm OS devices The supplied ParticleTrak CD-ROM also contains software for Palm OS hand-held devices.this unique program allows you to log particle concentrations onto your Palm OS computer. Once the Palm is connected to the ParticleScan instrument, the display of the Palm will show all six particle concentrations simultaneously. Alternatively you can choose to display the data collected during the past 12 minutes in a graphic format.the stored data can also be transferred to a PC for later analysis and printouts.

ParticleScan Selection Guide Which Model is Right for Me? ParticleScan Pro Industrial Hygienists Monitor & log particle levels in commercial and industrial facilities Establish a particle concentration profile Optimize pollution control measures Microbiologists & Medical Hygienists Monitor & log particle levels in medical and dental facilities Track down contamination sources Optimize airborne infection control measures Abatement and IAQ Professionals Verify & demonstrate the effectiveness of your contamination control measures Track down particulate pollutant sources Evaluate effectiveness of remedial action HVAC Professionals Verify filtration efficiency of installed particulate air filters Check the filter s efficiency for specific particle sizes Air Cleaning Professionals Compare filter efficiency of different air cleaning equipment Check for filter leakage Show customers the efficiency of your air cleaning system Demonstrate to customers the benefit of upgrading to more efficient filters Duct Cleaning Professionals Show the need for duct cleaning Perform measurements according to preliminary NADCA standard Certify your work Win government & healthcare contracts by particle count validation ParticleScan CR Cleanroom Operators Verify particle concentrations in cleanrooms and clean areas within seconds Test the integrity of HEPA filter banks Track down particle sources Establish a particle concentration profile Monitor and log particle concentrations for record keeping and reporting Optimize contamination control measures HEPA Filter Testing Determine HEPA filter efficiency Check HEPA filter for leaks Monitor & log particle levels