Observed infiltration and clogging characteristics for tested media.

Similar documents
SmartDrain TM for Enhanced Biofiltration Controls

BMP ACHIEVABILITY vs. WQS: Are there non-compliance risks for NPDES permittees AFTER BMP implementation?

INTRODUCTION BMP DATABASE PROJECTS IN PA

Permeable Pavement for Stormwater Management Porous Pavement

A Summary of the International Stormwater BMP Database

Wet Detention Ponds, MCTTs, and other Options for Critical Area Stormwater Control. Robert Pitt University of Alabama, Tuscaloosa, AL

Biofiltration and Downspout Filter Media Evaluation for BMP Decision-Making at the Port of Vancouver, WA

High-Rate Stormwater Treatment with Up-Flow Filtration

Removing Dissolved Pollutants from Stormwater Runoff. Andy Erickson, Research Fellow St. Anthony Falls Laboratory March 8, 2012

Stormwater Treatment Practice (STP) Calculator Instructions

TABLE B.3 - STORMWATER BMP POLLUTANT REMOVAL EFFICIENCIES

APPENDIX I. Water Quality Technical Memorandum

POLLUTANT REMOVAL EFFICIENCIES FOR TYPICAL STORMWATER MANAGEMENT SYSTEMS IN FLORIDA

Amendments to Filtration for Improving Water Quality Treatment. Andy Erickson, Research Fellow St. Anthony Falls Laboratory September 13, 2012

Small-Scale Pilot Testing of Stormwater Treatment Systems to Meet Numerical Effluent Limits in the Lake Tahoe Basin

Using Innovative Technologies to Mitigate Phosphorus Impacts from Urban and Ag Runoff

Need to Verify Model TSS Reduction Estimates

Enhanced Biofilter Treatment of Urban Stormwater by Optimizing the Hydraulic Residence Time in the Media

Pre-Treatment Bioretention Cells Bioswales IOWA STORMWATER MANAGEMENT MANUAL DECEMBER 16, 2015

Municipal Stormwater Ordinances Summary Table

Sizing Calculations and Design Considerations for LID Treatment Measures

Block or Log forms of PAM and PAM blends are manufactured for specific use in drainage waterways to remove suspended particulates from runoff.

FIELD PERFORMANCE FOR UP FLOW FILTRATION DEVICE

Grass Channel STORMWATER MANAGEMENT SUITABILITY KEY CONSIDERATIONS

A. Manufactured Treatment Device Characteristics

Abstract. Introduction

Porous Pavement Flow Paths

New Draft Model BMP Design Manual for San Diego Region

ALTERNATIVE DRY RETENTION POND DESIGN FOR ENHANCED NITROGEN REMOVAL. Evan Shane Williams, Ph.D., P.E.

Effectiveness of Coanda Screens for Removal of Sediment, Nutrients, and Metals from Urban Runoff

Removing Dissolved Pollutants from Stormwater Runoff. Andy Erickson, Research Fellow St. Anthony Falls Laboratory October 3, 2012

Stormwater Runoff Water Quality Characteristics From Highways in Lake Tahoe, California

2011 Guidance Manual for Development Stormwater Quality Control Measures

LID PLANTER BOX MODELING

COMPARISON OF STORMWATER QUALITY TREATMENT GUIDELINES AND CRITICAL STRUCTURAL BEST MANAGEMENT PERFORMANCE FACTORS AND PARAMETERS TO CONSIDER

BIOPOD TM BIOFILTER WITH STORMMIX BIOFILTRATION MEDIA. Inspection and Maintenance Guide

AN EXPERIMENTAL STUDY OF THE OPTIMAL THICKNESS OF A SAND LAYER IN A SAND FILTER WATER QUALITY STRUCTURE. July 1994

Hydrologic Study Report for Single Lot Detention Basin Analysis

FUNDAMENTALS OF GRANULAR MEDIA FILTRATION. Gordon Williams, PhD, PE East Bay Municipal Utility District

Pennsylvania Stormwater Best Management Practices Manual. Chapter 3. Stormwater Management Principles and Recommended Control Guidelines

16.0 Water Quality Management Criteria for Developed Land

SWMM5 LID Control for Green Infrastructure Modeling

Operation & Maintenance (OM) Manual v01. Bioretention Systems ENGINEERED SOLUTIONS

TECHNICAL MEMORANDUM. Table 1. Comparison of Best Management Practices and Their Applicability to the Pump Station

4.8. Subsurface Infiltration

Purification of Stormwater Using Sand Filter

Next Generation Bioretention

Sand Filter T-6. Description. Site Selection

Pressure Distribution Design

Chapter 2 BMP Selection

Implications of Using Different Water Sources When Hydrologically Compacting Bioretention Columns

A Hybrid Constructed Wetland System for Decentralized Wastewater Treatment

Renovation of the Filters at the Soldier Canyon Filter Plant in Fort Collins, Colorado

Appendix C1: Batch Kinetics Tests

Lake County WTP Improvements and Capacity Increase. OTCO 9 th Annual Water and Wastewater Workshop. Nick Pizzi Aqua Serv

4.8. Subsurface Infiltration

Septic Tank Soil Treatment Systems

Capability of the Aqua-Swirl Concentrator to Remove Trash from Stormwater Runoff

Water Quality Design Storms for Stormwater Hydrodynamic Separators

Drinking Water Production Using Moving Bed Filtration

WEFTEC 2006, Dallas, Texas FULL SCALE EVALUATION OF THE UPFLO TM FILTER - A CATCHBASIN INSERT FOR THE TREATMENT OF STORMWATER AT CRITICAL SOURCE AREAS

How are My Filters Doing? Filter Profiling Reveals All

Brian Hite. Research Assistant - CUW Environmental Science - UWT Civil and Environmental Engineering - UW

Pinellas County Stormwater Management Manual Training Workshop SMALL COMMERCIAL AREA CASE STUDY

Treatment of Dissolved Compounds and BMP Costs. John S. Gulliver, Professor Department of Civil Engineering February 17, 2012 MIDS review

Dual Media Filtration System for Reducing Pollutants in Storm Water Runoff

Portable Passive Precipitation Filter. Blending economic vitality with environmental sense URS. Marisco Ltd.

TEMPORARY SEDIMENT TRAP CODE

Rainfall, runoff and sediment transport in the Napa River watershed: now and a possible future

Water Treatment Plant Design at the Idaho Cobalt Project

BMP #: Water Quality Inserts

Stormwater Pollution Treatment BMP Discharge Structures

Tolin Hessell 4/21/2010. Literature Review on Stormwater Management Basin Retrofits. I. Introduction

Precipitation Surface Cover Topography Soil Properties

Green Infrastructure Flood Reduction Computations

B. Install storm drain inlet protection to prevent clogging of the stormsewer and sediment loads to downstream stormwater facilities or waterbodies.

WRF Webcast Biofilter Conversion Guidance Manual

Dr. Mark Risse Dr. Sidney Thompson Xianben Zhu Keith Harris Department of Biological and Agricultural Engineering

Treatment Volume: Curve Numbers. Composite CN or Not? Treatment Volume: Curve Numbers. Treatment Volume: Calculation. Treatment Volume: Calculation

A Technology for Enhanced Control of Erosion, Sediment and Metal Leaching at Disturbed Land Using Polyacrylamide and Magnetite Nanoparticles

TECHNICAL BULLETIN. Synthetic Turf Athletic Field Drainage Design Assistance

FILTRATION FOR METALS REMOVAL FROM STORMWATER

HYDROLOGIC CONSIDERATIONS. 22 nd Annual Nonpoint Source Pollution Conference Saratoga Springs, NY

VERIFICATION STATEMENT

Project Overview. Project Background. BMP Database. BMP Performance Assessment. Data Evaluation Results and Findings. BMP Monitoring Guidance

Sunset Circle Vegetated Swale and Infiltration Basin System Monitoring Report: Rainy Seasons and

Filter Surveillance PSW Rocky Mountain Summit April 5, Advanced Process Control and Optimization

Runoff Volume: The Importance of Land Cover

Stormwater Management at Municipal Solid Waste Landfills

STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE

Modelling and Analysis of EES Systems Using SWMM

01719; PH (978) ; FAX (978) ; PH (503) ; FAX (503) ;

Module 14: Small Storm Hydrology, Continuous Simulations and Treatment Flow Rates The Integration of Water Quality and Drainage Design Objectives

Presented at the Water Environment Federation Technical Exposition and Conference, Orlando, FL, 1998.

Evapotranspiration and Related Calculations for Bioretention Devices

Applying landforming to reclamation: A case study in Central Appalachia

Understanding Stormwater Pollution Prevention Plans (SWPPPs) (SWPPPS)

Boise City Public Works General Drainage Plan Review Requirements Checklist

Summary of Water Monitoring Data

DESIGN AND MAINTENANCE OF STRUCTURAL BMPS

Transcription:

5. Biofiltration Media Evaluation; Geosyntec Consultants and Boeing Co., 2008 2012 This study investigated a variety of media types that can be used singly and in combination for use in stormwater treatment facilities, including media filters, biofilters, bioretention, rain gardens, etc. These tests were conducted specifically to determine the different media performance options for use in advanced biofiltration systems at an industrial site having very stringent numeric effluent limits. These stormwater treatment systems were designed to treat 90% of the long-term runoff volume from drainage areas ranging from 5 to 60 acres at the site. The main pollutants of interest for the project are cadmium, copper, lead, and dioxins, with other constituents being of secondary interest, based on historic stormwater quality monitoring results at the site. One primary project objective is for treated effluent concentrations to meet the low numeric effluent limits that have been applied to stormwater discharges through the site s NPDES permit. These numeric effluent limits are based on water quality standards. A challenge to the project design is that current site runoff concentrations for the pollutants of interest are generally below levels typically seen in urban and industrial stormwater runoff. A review of the literature on filtration media and onsite monitoring data (including existing treatment system performance results and previous media pilot testing studies) indicated that several promising media exist for consistently treating the pollutants of interest to the required effluent concentrations. However, many of these materials are very expensive; with potential construction costs being significant given the large volumes required for the systems based on early designs (estimated media volumes for the project have ranged from 5,000 12,000 cubic yards). There are newly available materials that are promising, but little, if any, data are available to quantify their performance. These tests therefore evaluated these candidate materials under procedures that have proven successful during past media investigations for stormwater treatment effectiveness. Observed infiltration and clogging characteristics for tested media.

Media mixtures performed more consistently under a broader range of conditions than individual components used separately. The mixtures capitalize on the pollutant removal strengths of their components, while providing other components that may address the weaknesses (such as the release of cations in large concentrations during ion exchange). The media mixtures that are most robust (longest run times before clogging, with moderate flow rates and suitable contact times for pollutant removal) are: Rhyolite sand, SMZ, and GAC mixture (blended mixture) and the Rhyolite sand, SMZ, GAC-PM mixture (blended mixture). They had very similar performance attributes. The added peat provided some additional benefits for metal reductions at high flow rates. The GAC in these mixtures (when mixed with the other components) also provided better control for a number of other constituents, including nitrates. Site filter sand-gac-site Zeolite (layered) clogged earlier, but possibly would have fewer exceedences overall. The drawback to the layering of the filter components is the change in flow rate and contact time. In terms of statistically significant removals, both R-SMZ-GAC and S-Z-GAC (layered) media combinations performed similarly, although the current site layered media combination did not demonstrate statistically significant removals for lead. Any media combination that included GAC was effective for TCDD removal. All of the media tested had very high levels (approaching 90%) of removals of particulates, even down to very small particle sizes (as small as 3 µm), with concurrent good removals of pollutants strongly associated with the particulates (such as for total aluminum, iron, and lead). Media performance plots for copper from long-term, full-depth column tests. Some constituents and some media required a certain contact time before retention, while others were more capable of pollutant retention more rapidly and at lower influent concentrations. For example, when the contact time was less than 10 minutes, the metal removals were much less than for the longer contact times. Also, greater contact with GAC resulted in slightly better nitrate removals, while the

greater contact time for phosphate resulted in greater losses of the phosphate from the media. This type of trade-off between improved removal and increased leaching was seen for several mediaconstituent combinations. Longer retention times can be achieved through deeper media beds or slower flow rates and larger surface areas. The column tests confirmed generally the results of the laboratory studies that showed that good removals could be achieved with relatively slow to moderate flow rates (5 to 60 meters/day) and moderate contact times of the water with the media (10 to 40 minutes). Media performance plots for lead from varying-depth column tests. The GAC was the most important component in these mixtures, while the addition of either of the zeolites was also needed. The specific choice of which would be dependent on costs and specific ion exchange issues. The sand is critical to moderate the flow rates and to increase the contact times with the coarser media, unless other flow controls were used in the filter designs. The Rhyolite sand added some removal benefits compared to the site sand. As noted, a small amount of peat added to the mixture increases metal removals during high flow rates. Therefore, the best mixture for removal of pollutants to levels that met the effluent discharge limits was the combination of Rhyolite sand (30%), surface modified zeolite (30%), GAC (30%), and approximately 10% peat. To minimize the leaching of constituents from the GAC, its concentration could be reduced, but then nitrate removals would be limited. 5.1 Enhanced Underdrain Systems for Biofilters The treatment of stormwater by biofilters is dependent on the hydraulic residence time in the device for some critical pollutants. The effective use of biofilters for the control of stormwater in combined sewered areas is also related to residence time, as it is desired to retain the water before discharge to the drainage system in order to reduce the peak flows to the treatment plant. This research is

conducting a series of tests to determine the hydraulic characteristics of sand-based filter media (having a variety of particles sizes representing a range of median particle sizes and uniformity coefficients) during pilot-scale trench tests. The drainage rate in biofiltration devices is usually controlled using an underdrain that is restricted with a small orifice or other flow-moderating component. These frequently fail as the orifices are usually very small (<10 mm) and are prone to clogging. A series of tests were also conducted using a newly developed foundation drain material (SmartDrain TM ) that offers promise as a low flow control device with minimal clogging potential. A pilot-scale biofilter using a trough 3m long and 0.6 x 0.6m in cross section is being used to test the variables affecting the drainage characteristics of the underdrain material (such as length, slope, hydraulic head, and type of sand media). Current tests are also being conducted to test the clogging potential of this drainage material. SmartDrain TM installed in pilot-scale biofilter. The results from the experiments conducted to test the variables affecting the drainage characteristics of the filter media indicate that slope of the SmartDrain TM material had no significant effect on the stage-discharge relationship whereas effect of length of the SmartDrain TM material had a very small effect on the discharge. Research is ongoing to investigate the clogging potential of the SmartDrain TM material. Only about 20% reductions in the outflow rate of the filter media have been observed during the clogging tests having a total load of about 40 kg/m 2 onto the filter area, about twice the load that can usually cause clogging of biofilter media. Reduction in flow with increased sediment loading.

0.14 0.12 0.25 inches Flow rate (L/s) 0.1 0.08 0.06 0.04 1.1 to 9.4 ft 0.20 inches 1.25 ft clean water 1.25 ft dirty water 0.02 0.1 inches 0 0 0.2 0.4 0.6 0.8 1 1.2 Head (m) SmartDrainTM flow rates compared to very small orifices. Turbidity (NTU) measurements showed that the effluent NTU decreased rapidly with time, indicating significant retention of silt in the test biofilter during the clogging tests. These preliminary tests indicate that the SmartDrain TM material provides an additional option for biofilters, having minimal clogging potential while also providing very low discharge rates.