DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

Similar documents
DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: RHINO LININGS CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

ICC-ES Evaluation Report. ESR-3102 Reissued July 1, 2013 This report is subject to renewal August 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION (RIGID PU SYSTEMS)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE SPRAY MARKET, INC.

Trusted DIVISION: 07 SYSTEM. Conformity! ICC-ES Evaluation. not specifically. Copyright 2014

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS

ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE DOW CHEMICAL COMPANY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: JOHNS MANVILLE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: SES FOAM

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General

Trusted ICC ES DIVISION: 07 LTD. PLASTI FAB CANADAA PLASTISPAN. Look. Conformity! Evaluation. ICC-ES Evaluation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: TERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: REFLECTIX INCORPORATED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

DIVISION: FINISHES SECTION: FIRE RETARDANT COATINGS REPORT HOLDER: FIRE RETARDANT COATINGS OF TEXAS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: COVESTRO, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION

REPORT HOLDER: INSULFOAM, A DIVISION OF CARLISLE CONSTRUCTION MATERIALS, INC TH AVENUE EAST PUYALLUP, WASHINGTON EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS

Trusted ICC ES DIVISION: ATLANTA, CGF PRO, ENERGYS. Look. Conformity! Evaluation. ICC-ES Evaluation

DIVISION: FINISHES SECTION: FIRE RETARDANT COATINGS REPORT HOLDER: INTERNATIONAL FIREPROOF TECHNOLOGY INC. / PAINT TO PROTECT INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: BASF CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

Originally Issued: 07/31/2015 Revised: 07/31/2017 Valid Through: 07/31/ General

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: APPLIED FIREPROOFING REPORT HOLDER: CARBOLINE COMPANY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

DIVISION: CONCRETE SECTION: SPECIALTY PLACED CONCRETE REPORT HOLDER: EMMEDUE S.P.A.

Originally Issued: 07/06/2009 Revised: 04/07/2017 Valid Through: 07/31/2017

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

REPORT HOLDER: COREV AMERICA BRITTMOORE PARK DRIVE HOUSTON, TEXAS EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: CERAMICA LA ESCANDELLA, S.A.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

REPORT HOLDER: CALIFORNIA EXPANDED METAL PRODUCTS COMPANY (CEMCO) CROSSROADS PARKWAY NORTH, SUITE 325 CITY OF INDUSTRY, CALIFORNIA 91746

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

REPORT HOLDER: ATLAS EPS, A DIVISION OF ATLAS ROOFING CORPORATION 8240 BYRON CENTER SOUTHWEST BYRON CENTER, MICHIGAN EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

REPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: BORAL ROOFING LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS REPORT HOLDER: HB&G BUILDING PRODUCTS, INC.

REPORT HOLDER: JOHNS MANVILLE TH STREET DENVER, COLORADO EVALUATION SUBJECT:

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: FLOOD FLAPS, LLC

REPORT HOLDER: CARLISLE SYNTEC POST OFFICE BOX 7000 CARLISLE, PENNSYLVANIA EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KAYCAN LTD.

REPORT HOLDER: GEORGIA PACIFIC GYPSUM LLC 2861 MILLER ROAD DECATUR, GEORGIA EVALUATION SUBJECT: DENSELEMENT BARRIER SYSTEM

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

Spray Foam Requirements for thermal barriers and ignition barriers in the IRC. Presenter

Originally Issued: 03/21/2014 Revised: 04/12/2018 Valid Through: 03/31/2019

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: RIDGE VENTS REPORT HOLDER: VERSCENE, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: ROOF PANELS REPORT HOLDER: ROSER CO., LTD.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: BOSTITCH FASTENING SYSTEMS

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: GRABBER NAILS FOR GYPSUM WALLBOARD INSTALLATION

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: WESTCOAT

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: CITADEL ARCHITECTURAL PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

REPORT HOLDER: GREENMAKER INDUSTRIES, LLC 697 OAKWOOD AVENUE WEST HARTFORD, CONNECTICUT EVALUATION SUBJECT: DECOPLAST DDARS NOTCHED

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: SMARTVENT PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS

Transcription:

0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3458 Reissued 11/2016 This report is subject to renewal 11/2017. DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 21 00 THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC MCKINNEY, TEXAS 75069 EVALUATION SUBJECT: QUADFOAM 500 OPEN CELL SPRAY POLYURETHANE FOAM INSULATION Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2016 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-3458 Reissued November 2016 This report is subject to renewal November 2017. A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 21 00 Thermal Insulation REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC McKINNEY, TEXAS 75069 (972) 542-0072 www.quadrantchemical.com ADDITIONAL LISTEE: QUADRANT URETHANE TECHNOLOGIES McKINNEY, TEXAS 75069 (972) 542-0072 www.quadfoam.com EVALUATION SUBJECT: QUADFOAM 500 OPEN-CELL SPRAY POLYURETHANE FOAM INSULATION 1.0 EVALUATION SCOPE Compliance with the following codes: 2012 and 2009 International Building Code (IBC) 2012 and 2009 International Residential Code (IRC) 2012 and 2009 International Energy Conservation Code (IECC) 2013 Abu Dhabi International Building Code (ADIBC) The ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced in this report are the same sections in the ADIBC. Properties evaluated: Surface-burning characteristics Physical properties Thermal resistance (R-values) Attic and crawl space installation 2.0 USES Quadfoam 500 is used as a nonstructural thermal insulating material in buildings of Type V-B construction (IBC) and nonfire-resistance-rated construction under the IRC. The insulation is for use in wall cavities and floor/ceiling assemblies, and, when installed as described in Section 4.4, in attics and crawl spaces. 3.0 DESCRIPTION 3.1 General: Quadfoam 500 is a two-component, low-density, open-cell, spray-applied, polyurethane foam plastic insulation. The installed nominal density of Quadfoam 500 is 0.5 pcf (8 kg/m 3 ). The two components of the insulation are polymeric isocyanate (A-component) and a polymeric resin (B-component), which, when stored in unopened containers at temperatures between 40 F and 100 F (4.4 C and 37.8 C), have a shelf life of twelve months. 3.2 Surface Burning Characteristics: When tested in accordance with ASTM E84, at a maximum thickness of 4 inches (102 mm) and a nominal density of 0.5 pcf (8 kg/m 3 ), Quadfoam 500 has a flame-spread index of 25 or less and a smoke-developed index of 450 or less. Thicknesses of up to 7½ inches (191 mm) for wall cavities and 11½ inches (292 mm) for ceiling cavities are recognized, based on room corner fire testing in accordance with NFPA 286, when the product is covered with minimum ½-inch-thick (13 mm) gypsum wallboard or an equivalent thermal barrier complying with, and installed in accordance with, the applicable code. 3.3 Thermal Resistance, R-values: Quadfoam 500 has thermal resistance (R-values) at a mean temperature of 75 F (24 C) as shown in Table 1. 3.4 Intumescent Coatings: 3.4.1 QuadCoat TB Intumescent Coating System: The QuadCoat TB intumescent coating system consists of QuadCoat ICP Primer and QuadCoat TB intumescent Top Coat coatings, manufactured by TPR 2 Corporation. The coatings are single-component, water-based coatings, drums and having a shelf life of 12 months when stored in 3.4.2 TPR² Fireshell TB Intumescent Coating System: The Fireshell TB intumescent coating system consists of Fireshell ICP Primer and Fireshell TB Top Coat coatings, manufactured by TPR² Corporation. The coatings are single-component, water-based coatings, drums and having a shelf life of 12 months when stored in 3.4.3 Quadcoat IB Intumescent Coating: Quadcoat IB intumescent coating, manufactured by TPR² Corporation, is a single-component, water-based coating. The coating is drums and has a shelf life of 12 months when stored in ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2016 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 4 1000

ESR-3458 Most Widely Accepted and Trusted Page 2 of 4 3.4.4 TPR² Fireshell IB Intumescent Coating: Fireshell IB intumescent coating, manufactured by TPR² Corporation, is a single-component, water-based coating. The coating is supplied in 5-gallon (19 L) pails and 55- gallon (208 L) drums and has a shelf life of 12 months when stored in factory-sealed containers at temperatures above 50 F 3.4.5 DC315 Intumescent Coatings: DC315 Primer and DC315 Top Coat are intumescent coatings, manufactured by International Fireproof Technology Inc. The coatings are single-component, water-based coatings, supplied in 5- gallon (19 L) pails and 55-gallon (208 L) drums and have a shelf life of two years when stored in factory-sealed containers at temperatures between 41 F (5 C) and 95 F (35 C). 4.0 INSTALLATION 4.1 General: Quadfoam 500 must be installed in accordance with the manufacturer s (Quadrant Urethane Technologies) published installation instructions and this report. The manufacturer s installation instructions and this report must be strictly adhered to, and a copy of the instructions and this evaluation report must be available on the jobsite at all times during installation. 4.2 Application: The insulation must be applied using spray equipment specified by Quadrant Urethane Technologies. The product must not be used in areas which have a maximum service temperature greater than 180 F (82 C), nor in electrical outlet or junction boxes or in contact with rain or water. The product must be protected from the weather during and after application. The insulation can be installed in a single pass up to a maximum 13 1 / 2 -inch (343 mm) thickness. 4.3 Thermal Barrier: 4.3.1 Application with a Prescriptive Thermal Barrier: Quadfoam 500 must be separated from the interior of the building by an approved thermal barrier complying with, and installed in accordance with, IBC Section 2603.4 or IRC Section R316.4, as applicable, except where insulation is in an attic or crawl space as described in Section 4.4. Thicknesses up to 7 1 / 2 inches (191 mm) for wall cavities and 11½ inches (292 mm) for ceiling cavities are recognized based on room corner testing in accordance with NFPA 286, when covered with minimum ½-inch-thick (13 mm) gypsum wallboard or an equivalent thermal barrier complying with, and installed in accordance with, the applicable code. 4.3.2 Application without a Prescriptive Thermal Barrier: 4.3.2.1 Application with the QuadCoat TB Intumescent Coating System: The prescriptive, 15- minute thermal barrier may be omitted when installation is in accordance with this section (Section 4.3.2.1). The insulation and coatings may be spray-applied to the interior facing of walls, the underside of roof sheathing or roof rafters, and in crawl spaces, and may be left exposed as an interior finish without a prescribed 15-minute thermal must not exceed 13 1 / 2 inches (343 mm). The thickness of the foam plastic applied to walls and/or vertical surfaces must not exceed 11 inches (279 mm). The foam plastic must be covered on all surfaces with the QuadCoat TB intumescent coating system (QuadCoat ICP Primer and QuadCoat TB Top Coat). The QuadCoat ICP Primer must be applied at a minimum wet film thickness of 9 mils (0.23 mm) [5-mil (0.13 mm) dry film thickness], at a rate of 0.53 gallon (2 L) per 100 square feet (9.2 m 2 ). After curing, QuadCoat TB Top Coat must be applied at a minimum wet film thickness of 15 mils (0.38 mm) [9-mil (0.23 mm) dry film thickness], at a rate of 1 gallon (3.8 L) per 100 square feet (9.2 m 2 ). The coatings must be applied over the Quadfoam 500 insulation and cured in be dry, clean and free of dirt, loose debris and other coating. Each coating must be applied in one coat by airless spray equipment at ambient temperatures above 50 F (10 C) and relative humidity of less than 70 percent. 4.3.2.2 Application with the TPR² Fireshell TB Intumescent Coating System: The prescriptive 15- minute thermal barrier may be omitted when installation is in accordance with this section (Section 4.3.2.2). The insulation and coatings may be spray-applied to the interior facing of walls, the underside of roof sheathing or roof rafters, and in crawl spaces, and may be left exposed as an interior finish without a prescribed 15-minute thermal must not exceed 13 1 / 2 inches (343 mm). The thickness of the foam plastic applied to walls and/or vertical surfaces must not exceed 11 inches (279 mm). The foam plastic must be covered on all surfaces with the TPR² Fireshell TB intumescent coating system (TPR² Fireshell ICP Primer and Fireshell TB Top Coat). The Fireshell ICP Primer must be applied at a minimum wet film thickness of 9 mils (0.23 mm) [5-mil (0.13 mm) dry film thickness], at a rate of 0.53 gallon (2 L) per 100 square feet (9.2 m 2 ). After curing, Fireshell TB Top Coat must be applied at a minimum wet film thickness of 15 mils (0.38 mm) [9-mil (0.23 mm) dry film thickness], at a rate of 1 gallon (3.8 L) per 100 square feet (9.2 m 2 ). The coatings must be applied over the Quadfoam 500 insulation and cured in be dry, clean and free of dirt, loose debris and other coating. Each coating must be applied in one coat by airless spray equipment at ambient temperatures above 50 F (10 C) and relative humidity of less than 70 percent. 4.3.2.3 Application with the DC 315 Intumescent Coating System: The prescriptive, 15-minute thermal barrier may be omitted when installation is in accordance with this section (Section 4.3.2.3). The insulation and coating system may be spray-applied to the interior facing of walls, the underside of roof sheathing or roof rafters, and in crawl spaces, and may be left exposed as an interior finish without a prescribed 15-minute thermal must not exceed 12 inches (305 mm). The thickness of the foam plastic applied to walls and/or vertical surfaces must not exceed 8 inches (203 mm). The foam plastic must be covered on all surfaces with the DC 315 intumescent coating system (DC 315 Primer and DC 315 Top Coat). The DC 315 Primer must be applied at a minimum wet film thickness], at a rate of 0.25 gallon (0.95 L) per 100 square feet (9.2 m 2 ). After curing, the DC 315 Top Coat must be applied at a minimum wet film thickness of 16 mils (0.41 mm) [11-mil (0.28 mm) dry film thickness], at a rate of 1 gallon (3.8 L) per 100 square feet (9.2 m 2 ). The coatings must be applied over the Quadfoam 500 insulation and cured in accordance with the coating

ESR-3458 Most Widely Accepted and Trusted Page 3 of 4 Surfaces to be coated must be dry, clean and free of dirt, adhesion of the coating. Each coating must be applied in one coat, by low-pressure airless spray equipment at ambient and substrate temperatures above 50 F (10 C) and relative humidity of less than 70 percent. 4.4 Attics and Crawl Spaces: 4.4.1 Application with a Prescriptive Ignition Barrier: When Quadfoam 500 insulation is installed within attics or crawl spaces, where entry is made only for service of utilities, an ignition barrier must be installed in accordance with IBC Section 2603.4.1.6 or IRC Sections R316.5.3 and R316.5.4, as applicable. The ignition barrier must be consistent with the requirements for the type of construction required by the applicable code and must be installed in a manner so that the foam plastic insulation is not exposed. Ventilation in the attic or crawl space must be in accordance with the applicable code. The attic or crawl space area must be separated from the interior of the building by an approved 15-minute thermal barrier as described in Section 4.3.1. 4.4.2 Application without a Prescriptive Ignition Barrier: Where Quadfoam 500 insulation is installed in accordance with Sections 4.4.2.1, 4.4.2.2, 4.4.2.3 or 4.4.2.4, the following conditions apply: (a) Entry to the attic or crawl space is only for the service of utilities and no storage is permitted. (b) There are no interconnected attic or crawl space areas. (c) Air in the attic or crawl space is not circulated to other parts of the building. (d) Attic ventilation is provided when required by IBC Section 1203.2 or IRC Section R806. Under-floor (crawl-space) ventilation is provided when required by IBC Section 1203.3 or IRC Section R408.1, as applicable. (e) Combustion air is provided in accordance with IMC (International Mechanical Code ) Section 701. 4.4.2.1 Application with QuadCoat IB Intumescent Coating: Quadfoam 500 insulation may be spray-applied, in attics, to the interior facing of walls and to the underside of roof sheathing or roof rafters; and in crawl spaces, as described in this section. The thickness of the insulation applied to the underside of roof sheathing and/or rafters and the underside of wood floors and/or floor joists in crawl spaces must not exceed 11½ inches (292 mm); the thickness of the insulation applied to the vertical surfaces must not exceed 7 1 / 2 inches (191 mm). The QuadCoat IB intumescent coating must be applied over the insulation in be dry, clean, and free of dirt, loose debris and other coating. The coating is applied with low-pressure airless spray equipment, at a minimum wet film thickness of 4 mils (0.10 mm) [3 mil (0.08 mm) dry film thickness], at a rate of 0.29 gallon (1.10 L) per 100 square feet (9.2 m 2 ). The coating must be applied where ambient and substrate temperature is at least 50 F The attic or crawl space area must be separated from the interior of the building by an approved 15-minute thermal barrier as described in Section 4.3.1. 4.4.2.2 Application with TPR² Fireshell IB Intumescent Coating: Quadfoam 500 insulation may be spray-applied, in attics, to the interior facing of walls and to the underside of roof sheathing or roof rafters; and in crawl spaces, as described in this section (Section 4.4.2.2). The thickness of the insulation applied to the underside of roof sheathing and/or rafters and the underside of wood floors and/or floor joists in crawl spaces must not exceed 11½ inches (292 mm); the thickness of the insulation applied to the vertical surfaces must not exceed 7 1 / 2 inches (191 mm). The Fireshell IB intumescent coating must be applied over the insulation in accordance with the coating Surfaces to be coated must be dry, clean, and free of dirt, adhesion of the coating. The coating is applied with lowpressure airless spray equipment, at a minimum wet film thickness], at a rate of 0.29 gallon (1.10 L) per 100 square feet (9.2 m 2 ). The coating must be applied where ambient and substrate temperature is at least 50 F The attic or crawl space area must be separated from the interior of the building by an approved 15-minute thermal barrier as described in Section 4.3.1. 4.4.2.3 Application with DC315 Intumescent Coating System: Quadfoam 500 insulation may be spray-applied, in attics, to the interior facing of walls and to the underside of roof sheathing or roof rafters; and in crawl spaces, as described in this section (Section 4.4.2.3). The thickness of the insulation applied to the underside of roof sheathing and/or rafters and the underside of wood floors and/or floor joists in crawl spaces must not exceed 11½ inches (292 mm); the thickness of the insulation applied to the vertical surfaces must not exceed 7 1 / 2 inches (191 mm). The DC315 Top Coat intumescent coating must be applied over the insulation in accordance with the coating Surfaces to be coated must be dry, clean, and free of dirt, adhesion of the coating. The coating is applied with lowpressure airless spray equipment, at a minimum wet film thickness], at a rate of 0.25 gallon (0.95 L) per 100 square feet (9.2 m 2 ). The coating must be applied where ambient and substrate temperature is at least 50 F The attic or crawl space area must be separated from the interior of the building by an approved 15-minute thermal barrier as described in Section 4.3.1. 4.4.2.4 Use on Attic Floors: Quadfoam 500 insulation may be installed at a maximum thickness of 7½ inches (191 mm) between joists in attic floors. The insulation must be covered on all exposed surfaces with QuadCoat IB intumescent coating as described in Section 4.4.2.1, TPR² Fireshell IB intumescent coating as described in Section 4.4.2.2, or the DC315 intumescent coating system as described in Section 4.4.2.3, as applicable. The Quadfoam 500 insulation must be separated from the area beneath the attic by an approved thermal barrier. An ignition barrier in accordance with IBC Section 2603.4.1.6 or IRC Section R316.5.3, as applicable, may be omitted. 5.0 CONDITIONS OF USE The Quadfoam 500 spray-applied polyurethane insulation described in this report complies with, or is a suitable alternative to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The insulation and intumescent coatings must be installed in accordance with the report holder s and manufacturer s published installation instructions, this evaluation report and the applicable code. If there is a conflict between the published installation instructions and this report, this report governs.

ESR-3458 Most Widely Accepted and Trusted Page 4 of 4 5.2 This evaluation report and the manufacturer s (Quadrant Urethane Technologies) published installation instructions, when required by the code official, must be submitted at the time of permit application. 5.3 The insulation must be separated from the interior of the building by an approved 15-minute thermal barrier as described in Section 4.3.1, except as noted in when installed as described in Section 4.3.2. 5.4 The insulation must not exceed the thicknesses and density noted in Sections 3.2, 4.3 and 4.4 of this report. 5.5 The insulation must be protected from the weather during and after application. 5.6 A vapor retarder must be installed in accordance with the applicable code. 5.7 The insulation must be applied by installers approved by Quadrant Urethane Technologies. 5.8 Use of the insulation in areas where the probability of termite infestation is very heavy must be in accordance with 2012 IBC Section 2603.9, 2009 IBC Section 2603.8 or IRC Section R318.4, as applicable. 5.9 Jobsite certification and labeling of the insulation must comply with IRC Sections N1101.4 and N1101.4.1 and IECC Sections 303.1.1 and 303.1.2, as applicable. 5.10 The insulation components are manufactured in McKinney, Texas, under a quality control program with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC-ES Acceptance Criteria for Spray-applied Foam Plastic Insulation (AC377), dated November 2012 (editorially corrected April 2013), including data in accordance with Appendix X of AC377. 6.2 Reports of room corner fire testing in accordance with NFPA 286. 7.0 IDENTIFICATION All packages and containers of Quadfoam 500 insulation components must be labeled with the Quadrant Urethane Technologies, name and address; the product name (Quadfoam 500); the product type (A- or B-component); the flame spread index and the smoke-developed index; the shelf life and expiration date; the mixing instructions; the density; and the evaluation report number (ESR-3458). The QuadCoat (ICP Primer, TB Top Coat, IB), Fireshell (IB) and DC315 (Primer and Top Coat) intumescent coatings must be identified with their respective manufacturer s name and address, the product name and use instructions. TABLE 1 THERMAL RESISTANCE (R-VALUES 1,2 ) Quadfoam 500 THICKNESS (inches) R-VALUE ( F ft 2 h/btu) 1 3.6 4 14 6 21 7.5 26 8 28 10 35 11 38 11.5 40 12 42 13 46 13.5 47 For SI: 1 inch = 25.4 mm, 1 F ft 2 h/btu = 0.176 110K m 2 /W. 1 R-values are calculated based on tested k values at 1- and 4-inch thicknesses. 2 R-values greater than 10 are rounded to the nearest whole number.