HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

Similar documents
University of Delaware

MODELS: SM & SMSS

HDI 2200 Choke Position Indicator

SECTION VIBRATION ISOLATION

DEEP SOAK PRODUCT REQUIREMENTS. A. Product Requirements. B. Product Inspection. C. Clearance Requirements T01-A

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

C. Concrete Inertia Bases: Drawings showing required concrete steel reinforcing, construction details, and dimensions.

ROOF MOUNT KIT OWNERS MANUAL

WHEN DISASSEMBLING ALUMINUM EXTRUSION, TIGHTEN ALL SETSCREWS AND LOCKS TO PREVENT LOSS DURING SHIPPING

optional parts for geberit Duofix carrier

VPL-3200B Residential Vertical Platform Lift Technical Specifications

FIXTURE CARRIERS TABLE OF CONTENTS S-WD-FC

Series Sump and Sewage Systems

Terrain HDPE. Product Guide

Agilent InfinityLab Preparative Flow Cells for MWD & DAD

Axiom. SURFACE MOUNTED ARRAY Patient Headwall. Installation Guidelines. Installation Instructions.

REV. 9/08. Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

Liner Replacement Instructions:

SECTION I -- IRONWORK

Com-Tray. Under Floor

1.2 ACTION AND INFORMATIONAL SUBMITTALS.1 Provide submittals in accordance with Section Submittal Procedures.

DARTMOUTH COLLEGE DESIGN September 15, 2004 &CONSTRUCTION GUIDELINES

Series 2000PV Mechanical Joint Restraint for PVC Pipe

H 12 Heavy Duty Modern Tripod 8 Seat Swing Heavy Duty Hangers

1.04 SUBMITTALS PLUMBING FIXTURES

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS

Model: LoLander Series Truck Scale Model: LL FT Model: LL FT Installation, Set-Up and Operation Manual

SECTION Manufactured Metal Casework FLEXIBLE LABORATORY FURNITURE SYSTEM (OPTIMA) USA VERSION

Multi-Piece Shower with Trench Drain

SECTION PLUMBING FIXTURES

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

THE INSTALLING INSTRUCTION FOR CONCEALED TANK

SECTION HANGERS AND SUPPORTS FOR PLUMBING

Stainless Steel Aeration Equipment Specification

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

Air flue duct for use with ecotec boilers

Thank you for purchasing the SC-CONVERSION System 500/600 Conversion Kit. This Kit is available in two different versions:

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS

FAST-08 F.A.S.T. Foldable, Adjustable, Stackable, Tool-Less System

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

Consolidated* Electromatic* Ball Valves

SECTION PLUMBING FIXTURES

Diffused Aeration Piping Equipment

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

Preparation and Installation of the FA, FAV, and FAS Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders

General Guidelines. Tools Required. Instructions for Part # SC500-AF. Safety

Technology. Enabling Design. Geberit Duofix Carrier

SERVICE MANUAL. PW & RPW Series Proofer / Retarder Installation Instructions - NOTICE -

SECTION HVAC INSTRUMENTATION AND CONTROLS INSTALLATION. (Applicable to IUPUI Only)

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.

YOUR SPLASH PAD RESOURCE

SGLP-RO. Installation and Operating Instructions for SCALEGARD TM LP REVERSE OSMOSIS FILTRATION SYSTEM. 3M TM Water Filtration Products

801-MORD Mordred FIXING: Ground. ORDER No: CUSTOMER: Complied by Date AB 30/06/15 ISSUE ECN DATE SIGN /07/15 AB

INSTALLATION MANUAL. All Types F Series Rev G

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

A. Division 01: Administrative, procedural, and temporary work requirements apply to this section.

FrostGuard 120 V 120 V PREASSEMBLED ELECTRIC HEATING CABLES FOR PIPE FREEZE PROTECTION AND ROOF & GUTTER DE-ICING INSTALLATION INSTRUCTIONS

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

INSTALLATION INSTRUCTIONS

PIPING SPECIALTIES (PLUMBING) A. American Society for Testing and Materials (ASTM):

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Fig. 1 - Standard Clevis Hanger

CEILING & WALL SYSTEMS

Aegis Heavy Capacity 20K Floor Scale. MODEL: 6200 Series. Installation Manual

Essex County College - West Essex Campus Addition And Renovations Dib # / SECTION DOMESTIC WATER PIPING SPECIALTIES

USER S OPERATING AND INSTRUCTION MANUAL

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

Model # 362S-RDP. 9/17/2012 Page 1 of 12

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System. January 2012 Version

SOUTHEASTERN PENNSYLVANIA TRANSPORTATION AUTHORITY 1234 MARKET STREET, PHILADELPHIA, PA 19107

MODEL 3200 / 3201 CONTENTS. Installation, Operation, and Maintenance Instructions 1.0 GENERAL 2.0 INSTALLATION 3.0 OPERATION 4.

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.

Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19

Union County Vocational - Technical Schools Scotch Plains, New Jersey

1/17/2005 FAQ - Sothebys doc 1

(01) Thermo Bond Buildings Military Service Shelter: DOG KENNEL OPERATING AND SETUP MANUAL MSS-RP-1-20P

SECTION OUTLET, PULL, AND JUNCTION BOXES

Model # 338S-RDP. 7/31/2012 Page 1 of 13

TYPICAL INSTALLATION INSTRUCTIONS

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

UL / FM D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves

U-LAP. UTR-30 & UTR-70 Recipro Air Lappers Repair Manual. BORIDE Engineered Abrasives 2615 Aero Park Dr. Traverse City, MI

SECTION METAL STAIRS

Loading Arm Installation, Maintenance & Safety Manual

PowerDrain Section. Technical Handbook and Product Catalog. Heavy duty trench drainage

`bfifkd=c^k=prmmloq=molar`qp

FLEXTRAY Wire Basket - Splicing Accessories

GB-75. Submittal Specifications Installation Application Specific Details

BESTMOVE STANDING TRANSFER AID

Overview. Sigma Flex SIGMA FLEX ADAPTABLE LABORATORY FURNITURE SOLUTIONS. The Sigma Flex System. Designed for the Lab of Tomorrow...

Installation Instructions

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Operating Instructions

Transcription:

HALSEY TAYLOR OWNERS MANUAL Classic TM Series BarrierFree Water Coolers Refrigerated Fountains with Back Panel Figure HTERQ Figure HTSRQ Figure 3 HTSERQ Figure HTESRQ Figure 3 Model HTERQ HTSRQ HTSERQ HTESRQ Description Classic TM Series Extended Reach Classic TM Series Standard Reach Classic TM Series Dual Installation Classic TM Series Dual Installation INSTALLER Review these instructions before beginning installation. Be sure that installation conforms to all plumbing, electrical and other applicable codes. When installation is complete, ensure these instructions are left in the plastic bag provided inside the installed unit for future reference. Service to be performed by authorized service personnel only. NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices to available water lines. This can, however, cause electrical feedback in the plumbing circuit, which results in an electrolysis effect occurring in the fountain. This may result in water which has a metallic taste to it or has a noticeable increase in the metallic content of the water. When inspecting plumbing circuit, remember the line may be grounded some distance from the installation, and may occur outside the building or area in which the unit is being installed. This condition can be avoided (in most cases) by using recommended materials during installation. Any drain fittings provided by the installer should be made of plastic which will electronically isolate the fountain from the remainder of the building s plumbing circuits. 97877C (Rev. A 3/0)

/" O.D. TUBE WATER INLET TO COOLER 3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY HTERQ*E HTSRQ*E HTESRQ*K HTSERQ*K Installation Package BUILDING WATER INLET The components for installation are packed in three separate boxes, regardless of the type of unit being installed. The boxes contain the following: NOTE: WATER FLOW DIRECTION 33 50986C 97877C (Rev. A 3/0) Figure 5 Water Supply Connections Box No. : Wall Frame(s) Box No. : Remote Chiller, SJ8Q Box No. 3: Fountain(s), Arm(s) and Panels Additional materials, as noted in the Parts List, are also shipped in these boxes. Parts List Number Required Item Part No. Description HTERQ HTSRQ HTESRQ HTSERQ See Fig. 3 5 6 7 8 9 0 3 5 6 7 8 9 0 3 5 6 7 8 9 30 3 3 556C 6638C 0080C 00370560 607050860 663730860 0070560 6636C 6633C 836C 837C 300C 300C 6837C 6835C 708C 6839C 6833C 706C 56C 75588C 75589C 55996C 7068C 70683C 5609C 690C 6935C 737C 7557C 70378C 75555C 7550C 55859C 053360 7360 005C 5005C 633C Bubbler Bubbler Tube Assembly Bubbler Nipple (Included w/item ) Bubbler Gasket Strainer Plate Drain Plug Drain Gasket Waste Tube (HTER) Waste Tube (HTSR) Basin Stainless Steel (HTER) Basin Stainless Steel (HTSR) Bottom Cover (HTER) Bottom Cover (HTSR) Upper Panel (HTER) Upper Panel (HTSR) Upper Panel (HTESR) Upper Panel (HTSER) Lower Panel (HTER/SR) Lower Panel(HTESR/SER) Drain Elbow Nut / Slip Joint Washer Seal Strainer (Supplied with Chiller) Tee / Union / Poly Tubing (Cut To Length) Push Lever Mounting Bracket Assy Bracket Pushbar Lever Rod Pushbar Rod Spring Clip Screw #0 x.38 PHMS Pushbar Side & Front Pushbar Insert Nut / Self Thread Regulator Hex Nut Regulator Retaining Nut Regulator 7, 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 5, 9, 0 0 9 9, 0 5 5 5 5 5 5 5 5 5 5 5 5 5 Regulator Holder SERVICE STOP (NOT FURNISHED) 5

5098C 55899C 7073C 70055C 6753890 HTERQ*E HTSRQ*E HTESRQ*K HTSERQ*K Item Part No. Description HTERQ HTSRQ HTESRQ HTSERQ See Fig. 3 35 36 37 NS Snap Bushing Pad Window Filler Backing Plate Speed Nut Screw 0 x / PHTC 8 0 8 0 6 0 6 0 5 5 5 5. Cut a rectangular wall opening 37/ (953 mm) W x 373/ H (959 mm) and / ( mm) above the floor line (see Figure 7). The dimensions are required to obtain proper rim and bubbler heights for compliance with ANSI standard A7... Reinforce the wall opening on all sides to adequately support the water fountain. This reinforcement must support up to 50 lbs. static load and provide a means for securing the frame assembly in place. NOTE: Building construction must allow for adequate air flow on both sides and top of remote chiller unit a minimum of (0 mm) is required. See chiller installation for additional instructions. Figure 6 HTSERQ RoughIn 3. Install plumbing and electrical roughins. A junction box for a (3) wire, 0 amp branch circuit is provided on the inside of the chiller. (Standard 0 Volts, 60 Hz, and single phase.). Remove frames and related hardware from packaging. Release the two shelf rods by cutting cable ties. Attach the two frames together through the upright supports with () 5/6 x 3/ (9 mm) long bolts and nuts (provided). Tighten securely. MAKE SURE FRAME CONFIGURATION MATCHES THE COOLER TO BE INSTALLED REVERSED CONFIGURATION: HIGHER UNIT ON THE RIGHT STANDARD CONFIGURATION: HIGHER UNIT ON THE LEFT Figure 7 RoughIn Assembly DualStation Mounting Frames 3 97877C (Rev. A 3/0)

5. Install the frame assembly squarely in wall opening with frame upright support edges flush with the finished wall face. Secure the frame to the wall through holes with () 5/6 bolts or screws (not provided). Tighten securely. NOTE: Be sure that frame is squared in location. Do not use less than required screw quantity and size. 6. Attach the chiller shelf support rods to the right side of the frame uprights at the second set of holes counting from the bottom and to the shelf at the () side holes. Line up the other shelf holes with the frame bottom holes and fasten the assembly to the wall opening using appropriately sized screws or bolts and nuts (not provided). MODEL HTSER SHOWN MODEL HTESR Legend Item A B C D Description / O.D. Tube Water Outlet Connection 3/8 O.D. Tube Water Inlet Connection / O.D. Waste Tube Electrical Inlet on Chiller 97877C (Rev. A 3/0) Figure 8 HTSERQ RoughIn Dimensions

. Cut a rectangular wall opening 83/ (75 mm) W x 373/ H (959 mm) and / ( mm) above the floor line (see Figure 0). The dimensions are required to obtain proper rim and bubbler heights for compliance with ANSI standard A7... Reinforce the wall opening on all sides to adequately support the water fountain. This reinforcement must support up to 50 lbs. static load and provide a means for securing the frame assembly in place. NOTE: Building construction must allow for adequate air flow on both sides and top of remote chiller unit. Minimum of (0 mm) is required. See chiller installation for additional instructions. Figure 9 HTERQ/HTSRQ RoughIn 3. Install plumbing and electrical roughins. A junction box for a (3) wire, 0 amp branch circuit is provided on the inside of the chiller. (Standard 0 Volts, 60 Hz, and single phase.). Remove frame and related hardware from packaging. Release the two shelf rods by cutting cable ties. Figure 0 RoughIn Assembly SingleStation Mounting Frames 5 97877C (Rev. A 3/0)

5. Install the frame squarely in wall opening with frame upright edges flush with the finished wall surface. Place shelf inside frame and line up the () holes on each. Insert loose ends of rods into holes on sides of shelf panel. Using appropriately sized screws or bolts (not provided), fasten the shelf and frame to the bottom of wall opening. Secure the frame sides and top to the wall using (0) 5/6 bolts or screws (not provided). NOTE: Be sure that frame is squared in location. Do not use less than the required screw quantity and size. MODELS HTER/HTSR HTERQ*E HTSRQ*E HTESRQ*K HTSERQ*K REQUIRED TOOLS AND MATERIALS These tables show special tools and/or additional materials (not provided) which are necessary to complete installation of these units: Special Tools Item Description Quantity NONE Additional Materials Item Description Quantity Unplated copper inlet pipe Service Stop HTERQ/HTSRQ/HTSERQ/HTESRQ INSTALLATION. Assemble and place frame in wall as shown on preceding pages.. Install chiller: Remove front panel of chiller. Remove and discard cardboard inner pack from between compressor and side panel. Slide chiller onto the shelf and position it to the left within the guides on the shelf. NOTE: Building construction must allow for adequate air flow on both sides, top and back of chiller. A minimum of (0mm) on both sides and top is required. See chiller installation for additional instructions. Legend Item Description A / O.D. Tube Water Outlet Connection B 3/8 O.D. Tube Water Inlet Connection C / O.D. Waste Tube D Electrical Inlet on Chiller Figure HTERQ/HTSRQ RoughIn Dimensions 97877C (Rev. A 3/0) 6 Figure Chiller Installation 3. Make water supply connections. Inlet port is marked on the chiller (/ O.D. copper tube). Bend the copper tube (provided) at an appropriate length from the chiller to opening in frame. Install the inline strainer (provided with chiller) by pushing it in until it reaches a positive stop, approximately 3/ (9mm) on the marked chiller inlet port. Attach an unplated and deburred copper water inlet line and a service stop (not provided) to the inline strainer. Turn on the water supply and flush the line thoroughly. (See Fig. 5). Hang the upper panel on the mounting frame hanger. Align holes in the panel with the holes in the mounting frame. Be sure that panel is engaged with hanger at top of frame before releasing it.

6. Connect the fountain drain waste tube to the building sanitary sewer system. Connection should be made in compliance with local plumbing code requirements. (Note: Plumbing trap is not included with the fountain). 7. Make connection between remote chiller outlet tube and fountain(s). Outlet port is marked on the chiller (/ O.D. copper tube). Install a / union/tee (provided) on the marked chiller outlet port. Insert the / poly tubing coming from the fountain(s) into the union/tee. Turn on water supply and check for leaks.(see Figs. 9 or 0) 5. Install fountain. Remove access cover plate on underside of fountains and SAVE the screws. Mount the fountains to the upper panel and frame with () 5/6 x 3/ (9mm) long bolts and nuts provided. Tighten securely. Note: Figure 3 Upper Panel Installation With HTSERQ/HTESRQ models, the standard reach fountain must be mounted at the upper position on panel. Figure Fountain Installation 7 35 36 9 5 DO NOT SOLDER tubes while inserted into the strainer as damage to orings may result. 8. These products are designed to operate on 005 PSIG supply line pressure. If inlet pressure is above 05 PSIG, a pressure regulator must be installed in the supply line. Any damage caused by connecting these products to a supply line with pressure lower than 0 PSIG or higher than 05 PSIG IS NOT covered under warranty. 9. Make electrical connections to the chiller. See chiller instructions. 0. Check stream height from bubbler. Stream height is factory set at 350 PSI. If supply pressure varies greatly from this, remove the cover bottom (Item 0 Figure 8) and adjust the screw on the regulator (Item 3 Figure 5). Clockwise adjustment will raise stream height and counterclockwise movement will lower stream height. For best adjustment, stream height should be approximately / (38mm) above the bubbler guard. (See Figure 7).. Mount lower panel. Loosen the two () #0 x 5/8 (6mm) screws at frame bottom lip. Slide upper tongue of lower panel under lower edge of already installed upper panel. Tighten previously loosened screws securely. 33 3 3 30 8 ADJUST SCREW (ITEM 6) TO ELIMINATE MECHANISM FREE PLAY OR CONTINUOUS FLOW FROM BUBBLER CONDITIONS 5 Figure 5 Push Bar Mechanism 3 37 0 7 3 STREAM HEIGHT ADJUSTMENT ACCESS HOLE 97877C (Rev. A 3/0)

TO BUBBLER 9 8 CHILLER OUTLET 6 CHILLER INLET Figure 6 Lower Panel Installation. Replace bottom access panel to fountain basin using screws provided. Tighten securely. Figure 9 HTERQ/HTSRQ Tube Routing TROUBLESHOOTING & MAINTENANCE Orifice Assembly: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice by poking with a small round file not over /8 diameter, or using a small diameter wire. DO NOT file or cut orifice material. Stream Regulator: If orifice is clean, regulate flow as in Step 0 of the installation instructions. If replacement is necessary, see parts list for correct regulator part number. Figure 7 Stream Height TO BUBBLER,3 5,6,7 9 7 9 9 CHILLER OUTLET 6 CHILLER INLET 0 3 8,5,3 9 0 5,6,7 3 8 Figure 0 HTSERQ/HTESRQ Tube Routing Actuation of Quick Connect Water Fittings: Cooler is provided with leadfree connectors which utilize an oring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing. (See Figure ) To insert tubing, push tube straight into fitting until it reaches a positive stop (approximately 3/ ).,5 Figure 8 Fountain Assembly Side View CAMDEN COURT OAK BROOK, IL 6053 630.57.3500 PRINTED IN U.S.A. Figure Quick Connect Fittings 97877C (Rev. A 3/0) 8