ADDENDUM No. 1 PROJECT SDARNG Construct Break/Locker Room Brookings FMS#8, CFMO#FBR461653F BID DATE 3:00 PM CT July 13, 2017 BID LOCATION Brookings Armory 300 5 th Street South, Brookings, SD 57006 ISSUE DATE July 10, 2017 NOTICE Failure to acknowledge all addenda in the BID may cause rejection of the BID. See Instructions to Bidders. SCOPE OF THIS ADDENDUM The following becomes a part of the original project manual and drawings, taking precedence over the items that may conflict. The bidder shall note receipt and make acknowledgment of the Addendum on his/her bid form, incorporating its provision in his/her bid. PRIOR APPROVALS The following manufacturers of the items and materials have been added to the list of approved manufacturers. Listing of an item does not change the requirements of the specifications. Equipment furnished shall meet the materials and performance requirements as specified. SECTION DESCRIPTION MANUFACTURER 230800 ERV Units Soler and Palau Aldes Greenheck 230800 Roof Curb Crystal Distribution Inc 230800 Roof Top Units Greenheck PROJECT MANUAL The following additions, changes and clarifications have been made to the Project Manual. Section 10 1400 Signage: Add: Insert specifications section 101400, attached at the end of this addendum. Page 1 of 3
DRAWINGS The following additions, changes and clarifications have been made to the Drawings. Drawing Sheet 5.1 Floor Plan: Change: Door 109: Change door swing to left hand door in lieu of that shown. Clarification: Break Room 108: The South wall will remain exposed brick; all other Break Room walls will be furred out with gypsum board as per Key Note 22. Clarification: Men 109 and Women 110: The lockers in the Men s Room, shown with dashed line, will be furnished and install by the Owner. The lockers in the Women s Room will be furnished and installed by the Contractor as per Key Note 21. Add: Mechanical Room 105: Provide 30 x 30 x 4 concrete housekeeping pad for hot water heater; Coordinate location with Mechanical. Drawing Sheet 6.1 Roof Plan: Add: Roof penetrations for water heater vent and combustion air; coordinate locations with Mechanical. Drawing Sheet 8.1 Building Sections: Clarification: Section 2/8.1: Typical interior CMU walls (4/8.2) shall terminate just above the ceiling, with lateral bracing as per Structural Details 3/4.7 and 4/4.7. Note that Wall Section 3/8.2 is a fire-rated wall and shall extend up to roof deck and shall be sealed with a one-hour firestopping assembly. Refer to Code Summary Plan 1.3 for location of fire-rated walls. Drawing Sheet 8.2 Building Sections: Clarification: Section 4/8.2: Typical interior CMU walls are non-rated, are not required to extent to deck, and may terminate just above the ceiling with lateral bracing as per Structural Details 3/4.7 and 4/4.7. Drawing Sheet 11.1 Door, Window & Room Finish Schedules: Change: Room Finish Schedule: Replace schedule shown with Revised Schedule attached at the end of this addendum. Note stained concrete floors in all rooms. Add: Door Schedule: Wood doors 109, 110 and 111 shall be undercut 1 for air transfer. Drawing Sheet 11.2 Door and Window Details: Clarification: Details 1/11.2 8/11.2: Delete all reference to burnished block or ground-face CMU; neither product is required. Clarification: Details 1/11.2 8/11.2: Delete bullnose CMU; provide furred out gypsum board walls where shown on floor plan, and gypsum board returns at door and window frames. Page 2 of 3
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes the following: 1. Panel signs. 1.3 DEFINITIONS A. ADA-ABA Accessibility Guidelines: U.S. Architectural & Transportation Barriers Compliance Board's "Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines." 1.4 SUBMITTALS A. Product Data: For each type of product indicated. B. Shop Drawings: Show fabrication and installation details for signs. 1. Show sign mounting heights, locations of supplementary supports to be provided by others, and accessories. 2. Provide message list, typestyles, graphic elements, including tactile characters and Braille, and layout for each sign. C. Samples for Initial Selection: Manufacturer's color charts consisting of actual units or sections of units showing the full range of colors available for the following: 1. Fiberglass sheet. D. Sign Schedule: Use same designations indicated on Drawings. E. Qualification Data: For Installer. F. Maintenance Data: For signs to include in maintenance manuals. 1.5 QUALITY ASSURANCE #22490.00.01 10 1400-1 7/10/2017
A. Installer Qualifications: Fabricator of products or an employer of workers trained and approved by manufacturer. B. Source Limitations for Signs: Obtain each sign type indicated from one source from a single manufacturer. C. Regulatory Requirements: Comply with applicable provisions in ADA-ABA Accessibility Guidelines. 1.6 PROJECT CONDITIONS A. Weather Limitations: Proceed with installation only when existing and forecasted weather conditions permit installation of signs in exterior locations to be performed according to manufacturers' written instructions and warranty requirements. B. Field Measurements: Verify recess openings by field measurements before fabrication and indicate measurements on Shop Drawings. PART 2 - PRODUCTS 2.1 MATERIALS A. Fiberglass Sheet: Molded, seamless, thermosetting, glass-fiber-reinforced polyester panels with a minimum tensile strength of 15,000 psi when tested according to ASTM D 638 and with a minimum flexural strength of 30,000 psi when tested according to ASTM D 790. B. Acrylic Sheet: ASTM D 4802, Category A-1 (cell-cast sheet), Type UVA (UV absorbing). 2.2 PANEL SIGNS A. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following: 1. ACE Sign Systems, Inc. 2. APCO Graphics, Inc. 3. ASI-Modulex, Inc. 4. Best Sign Systems Inc. 5. Gemini Incorporated. 6. Innerface Sign Systems, Inc. 7. InPro Corporation B. Interior Panel Signs: Provide smooth sign panel surfaces constructed to remain flat under installed conditions within a tolerance of plus or minus 1/16 inch measured diagonally from corner to corner, complying with the following requirements: 1. Laminated, Etched Photopolymer: Raised graphics with Braille 1/32 inch above surface with contrasting colors as selected by Architect from manufacturer's full range and laminated to acrylic back. 2. Edge Condition: Beveled. 3. Corner Condition: Rounded to ¼ radius. #22490.00.01 10 1400-2 7/10/2017
4. Mounting: Unframed. a. Wall mounted with concealed anchors. b. Manufacturer's standard anchors for substrates encountered. 5. Colors: As selected by Architect from manufacturer's full range. 6. Tactile Characters: Characters and Grade 2 Braille raised 1/32 inch above surface with contrasting colors. C. Tactile and Braille Sign: Manufacturer's standard process for producing text and symbols complying with ADA-ABA Accessibility Guidelines and with ICC/ANSI A117.1. Text shall be accompanied by Grade 2 Braille. Produce precisely formed characters with square-cut edges free from burrs and cut marks; Braille dots with domed or rounded shape. 1. Panel Material: Opaque acrylic sheet. 2. Raised-Copy Thickness: Not less than 1/32 inch. D. Engraved Copy: Machine engrave letters, numbers, symbols, and other graphic devices into panel sign on face indicated to produce precisely formed copy, incised to uniform depth. 1. Engraved Opaque Acrylic Sheet: Fill engraved copy with enamel. E. PANEL SIGN TYPES 1. Room Signs: a. Material: Photopolymer. b. Perimeter: Unframed. c. Copy: Tactile and braille. d. Character Style: Helvetica. e. Text: As indicated in the Sign Schedule. f. Symbol: Handicapped Accessible g. Sizes: 1) Sign: As indicated in sign schedule, or as required for compliance with ADA requirements. 2) Character: Minimum 5/8 high characters. h. Colors: 1) Character: as selected by Architect from manufacturer s full range. 2) Background: as selected by Architect from manufacturer s full range. i. Schedule: See schedule in part 3 of this section. 2.3 ACCESSORIES A. Anchors and Inserts: Provide nonferrous-metal or hot-dip galvanized anchors and inserts for exterior installations and elsewhere as required for corrosion resistance. Use toothed steel or lead expansion-bolt devices for drilled-in-place anchors. Furnish inserts, as required, to be set into concrete or masonry work. #22490.00.01 10 1400-3 7/10/2017
2.4 FABRICATION A. General: Provide manufacturer's standard signs of configurations indicated. 1. Welded Connections: Comply with AWS standards for recommended practices in shop welding. Provide welds behind finished surfaces without distortion or discoloration of exposed side. Clean exposed welded surfaces of welding flux and dress exposed and contact surfaces. 2. Mill joints to tight, hairline fit. Form joints exposed to weather to exclude water penetration. 3. Preassemble signs in the shop to greatest extent possible. Disassemble signs only as necessary for shipping and handling limitations. Clearly mark units for reassembly and installation, in location not exposed to view after final assembly. 4. Conceal fasteners if possible; otherwise, locate fasteners where they will be inconspicuous. 2.5 FINISHES, GENERAL A. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping. B. Appearance of Finished Work: Variations in appearance of abutting or adjacent pieces are acceptable if they are within one-half of the range of approved Samples. Noticeable variations in the same piece are not acceptable. Variations in appearance of other components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast. 2.6 ACRYLIC SHEET FINISHES A. Colored Coatings for Acrylic Sheet: For copy and background colors, provide colored coatings, including inks, dyes, and paints, that are recommended by acrylic manufacturers for optimum adherence to acrylic surface and that are UV and water resistant for three to five years for application intended. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of work. B. Verify that items, including anchor inserts, are sized and located to accommodate signs. C. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 INSTALLATION A. Locate signs and accessories where indicated, using mounting methods of types described and complying with manufacturer's written instructions. 1. Install signs level, plumb, and at heights indicated, with sign surfaces free of distortion and other defects in appearance. #22490.00.01 10 1400-4 7/10/2017
2. Interior Wall Signs: Install signs on walls adjacent to latch side of door where applicable. Where not indicated or possible, such as double doors, install signs on nearest adjacent walls. Locate to allow approach within 3 inches of sign without encountering protruding objects or standing within swing of door. 3. Interior Wall Signs: Install on walls at a height above finish floor to base line of characters is minimum of 48 inches to lowest tactile character and maximum of 60 inches to highest tactile character. B. Wall-Mounted Signs: Comply with sign manufacturer's written instructions except where more stringent requirements apply. 1. Silicone-Adhesive Mounting: Attach signs to irregular, porous, or vinyl-covered surfaces. 2. Shim Plate Mounting: Provide 1/8-inch thick, concealed aluminum shim plates with predrilled and countersunk holes, at locations indicated, and where other mounting methods are not practicable. Attach plate with fasteners and anchors suitable for secure attachment to substrate. Attach panel signs to plate using method specified above. 3.3 CLEANING AND PROTECTION A. After installation, clean soiled sign surfaces according to manufacturer's written instructions. Protect signs from damage until acceptance by Owner. 3.4 SIGN SCHEDULE A. Room Signs: 6 x 8 1. Men 109 - Men s Locker Room 2. Vestibule 111 - Women s Locker Room END OF SECTION 10 1400 #22490.00.01 10 1400-5 7/10/2017
This Page Intentionally Left Blank #22490.00.01 10 1400-6 7/10/2017
REVISED ROOM FINISH SCHEDULE NOT USED ADDENDUM NO. 1/ATTACHMENT 2