Building Envelope

Similar documents
2010 National Building Code Adoption and Associated Process Changes

Manitoba Energy Code for Buildings. Part 3 Building Envelope

1) For the purpose of this Section, the term common space shall mean all spaces required to

Feature Zone IECC 2009 IECC

Administrative Changes

Plan Check & Field Inspection Guide

Ontario s Building Code

WASHINGTON STATE ENERGY CODE, APPENDIX CHAPTERS

Prescriptive Checklist for the 2015 Washington State Energy Code

Boulder City NV Prepared by (Print Name) Signature Date

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

National Building Code Part 9 Energy Efficiency: Focus Paper to Assist in the Review of Proposed Changes

Public Notice New BC Building Code Requirements

City of High Point Airport Overlay District Noise Level Reduction Design Standards

Insulation, Fireblocking, Draftstopping and Crawl Space Requirements REVISION DATE: JANUARY 2017

2012 IECC Residential with State Adopted Changes

Table Air Barrier and Insulation Inspection Component Criteria

New Hampshire Residential Energy Code

Building Codes and Ordinances ARC 227

Energy Conservation Amendments to the Ontario Building Code

2006 INTERNATIONAL ENERGY CONSERVATION CODE

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

PART 9 ENERGY EFFICIENCY AND VENTILATION REQUIREMENTS (For Single and Two Family Dwellings)

Hardin County Planning and Development Commission

Inspection of New One- and Two- Family Dwellings

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

BUILDING PERMIT APPLICATION

2003 International Residential Building Code

BC BUILDING CODE ERRATA

Residential Building Inspections

2018 British Columbia Building Code Public Review of Proposed Changes

Thermal Bridging in Building Thermal Envelope Assemblies: Repetitive Metal Penetrations

OR LEGAL DESCRIPTION PLAN: BLOCK: LOT: APPLICANT / CONTACT:_ INSPECTION RESULTS TO BE MAILED TO THIS ? YES NO

Michigan Energy Code Training and Implementation Program

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Michigan Energy Code Training and Implementation Program

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

Chapter 2: Foundation

Thermal Bridging in Residential Construction

HPW Protocol Reference Manual

Residential Plan Review for New One and Two Family Dwellings

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Is Your Envelope Effective? BCBEC Luncheon January 29, 2009

Slab edge insulation is one of

REScheck Software Version Compliance Certificate

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and

A. GENERAL INFORMATION

IRC 2012 Key Changes

Chapter 1: Compliance

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

1998 and 2000 International Energy Conservation Code Version 3.0 April 2000

A.ENVELOPE AIR SEALING

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

FIRE AND SMOKE PROTECTION FEATURES

Residential Accessory Structures & Room Additions

FEMA P-593 STEP-BY STEP PRESCRIPTIVE RETROFIT FOR CRIPPLE WALL BRACING & ANCHORAGE TO FOUNDATION

SAN MIGUEL COUNTY & TOWN OF MOUNTAIN VILLAGE BUILDING DEPARTMENTS PRESCRIPTIVE ENERGY CODE & GREEN BUILDING STANDARD

Wisconsin Uniform Dwelling Code Energy Worksheet

Single Family Residence Building Permits

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

Compliance Certificate

HCM UNIVERSITY OF ALASKA FAIRBANKS Building Challenges in Alaska UNIVERSITY OF ALASKA FAIRBANKS

RESIDENTIAL ENERGY EFFICIENCY

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

One and Two Family Additions

#402 New Residential Submittal Checklist

Building Guide. Colorado Chapter of the International Code Council

The Homeowner s Building Application Checklist for Constructing a Residential Addition

2006 Building Code Energy and Occupancy Permit Requirements coming into force on January 1, 2012 Presentation to OBOA October 3, 2011

General Residential Code Requirements

Appendix RA Air Sealing and Insulation Key Points COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA

Building Design Data

The Inspection Process. Waxhaw N.C.

Sept 30, 2004 Page 1

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

Zero Carbon Building Energy Modelling Guidelines. October 31, 2017

REScheck Software Version Compliance Certificate

Top plates. Stud. Pre cut stud. 8 ft, 1 1/8 inch. 4 inch brick veneer ½ inch plywood sheathing. Insulation placed between the studs

ILLUSTRATED GUIDE. R22+ Effective Walls in Residential Construction in British Columbia NOVEMBER 2017

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

FIGURE R502.2 FLOOR CONSTRUCTION

Construction Report NYSERDA Residential Performance Challenge

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

Energy Code Basics for Residential Buildings. Presented by Newport Ventures NEWPORT VENTURES

APPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.

Technical Notes 43G - Brick Passive Solar Heating Systems - Part 7 - Details and Construction [Mar./Apr. 1981] (Reissued Sept.

High Performance, Energy Efficient Design for Wood Frame Buildings

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

REScheck Compliance Certificate Massachusetts Energy Code REScheck Software Version 3.6 Release 1 Data filename: O:\REScheck 38\38258.

RESIDENTIAL ENERGY EFFICIENCY

TYPICAL BEARING WALL FRAMING

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

Transcription:

9.36.2. Building Envelope Module 2 BCBC 9.36. 2014 1 Richard Kadulski Architect

9.36.2. Building Envelope Focus is on total building performance, not just thermal insulation Heat transfer and air leakage between conditioned space and unconditioned space Reference to many requirements already in Sections 9.7. and 9.25. 2 Richard Kadulski Architect

9.36.2. Building Envelope Scope and Application The walls in skylight shafts are treated like exterior walls. 9.36.2.1.(3) Walls less than 60 from horizontal are considered as roof assemblies Windows must conform to section 9.7 Properties of insulation, location and installation of air barriers, and vapour barriers must conform to section 9.25. 3 Richard Kadulski Architect

Scope and Application Any assembly that separates conditioned space from an adjoining storage garage, even if the garage is intended to be heated, must be insulated to the requirements for exterior assemblies. 9.36.2.1. (2) 4 Richard Kadulski Architect

9.36.2.2. Determination of Thermal Characteristics The thermal resistance of opaque assemblies uses effective thermal resistance this is a change from nominal R-values that has been relied on up to now This takes into account all material layers in an assembly, and the thermal bridging of high conductivity materials such as framing. Look-up tables are provided for most common assemblies, and information on how to calculate others (9.36.2.4.) 5 Richard Kadulski Architect

9.36.2.2. Determination of Thermal Characteristics Where a component of the building envelope is enclosed by unconditioned space, the effective R-value of the component can be reduced by 0.16 RSI 9.36.2.4.(4) 6 Richard Kadulski Architect

9.36.2.2. Determination of Thermal Characteristics Thermal characteristics of materials are determined in accordance with listed product standards In absence of product standards, assemblies can be tested to ASTM-C1363 as an alternative using an indoor temperature of 21±1 C and an outdoor air temperature of - 3 5 ± 1 C Log wall RSI-values must be determined by calculation in accordance with Section 305 of ICC 400, Design and Construction of Log Structures. 7 Richard Kadulski Architect

9.36.2.2. Determination of Thermal Characteristics Product standards for many insulation materials are listed in the code New products not listed are acceptable, but must be tested in accordance with ASTM-C177 or ASTM- C518 Calculations and tests at an average temperature of 24±2 C and a temperature differential of 22±2 C 8 Richard Kadulski Architect

9.36.2.4. Calculation of Effective Thermal Resistance of Assemblies Heat transfer depends on the heat flow through a given area with a temperature difference across the element The NECB requires all building envelope assemblies and components to comply with the maximum U-values (overall thermal transmittance). Requirements in 9.36.2. are stated in RSI values which are the reciprocal of U-values. 9 Richard Kadulski Architect

9.36.2.4. Calculation of Effective Thermal Resistance of Assemblies The same nominal insulation can produce different effective thermal resistance values depending framing type and material configurations To calculate effective thermal resistance, contributions from all portions of an assembly, including heat flow through studs and insulation are taken into account. 10 Richard Kadulski Architect

Difference Between Nominal and Effective Thermal Resistance of Assemblies Assembly Conventional 2x6 wood stud @ 16 o/c; R-20 batt insul; gyp bd interior; ply sheathing; wood siding Advanced 2x6 framing, studs @ 24 o/c, R- 20 batt insul; gyp bd interior; ply sheathing; wood siding 2x4 wood studs @ 16 o/c; R12 batt insul; plus R-10 XPS, gyp bd interior; ply sheathing; wood siding 2x6 steel studs @ 16 o/c, ; R-20 batt insul.; gyp bd interior; ply sheathing; wood siding Nominal R-value 20 (RSI 3.52) 20 (RSI 3.52) 22 (3.87) 20 (RSI 3.52) Effective R-value 17.2 (RSI 3.02) 18.2 (RSI 3.20) 22.4 (RSI 3.94) 11.35 (RSI 1.99) 11 Richard Kadulski Architect

9.36.2.6. Thermal Characteristics of Above Ground Opaque Assemblies Prescriptive path: Requirements vary whether or not an HRV is installed Table with minimum effective RSI-values Look-up tables for most common assemblies, and information on how to calculate others provided in the Appendix 12 Richard Kadulski Architect

9.36.2.6. Thermal Characteristics of Above Ground Opaque Assemblies Table 9.36.2.6.A Effective RSI-values without HRV Assembly Climate Zone (Heating Degree Days C) Zone 4 < 3,000 Zone 5 3,001 to 3,999 Zone 6 4,000 to 4,999 Zone 7A 5,000 to 5,999 Zone 7B 6,000 to 6,999 Ceilings 6.91 (39.23) 8.67 (49.2) 8.67 (49.2) 10.43 (59.2) 10.43 (59.2) Cathedral ceilings 4.67 (26.5) 4.67 (26.5) 4.67 (26.5) 5.02 (28.5) 5.02 (28.5) Walls (2x6 @ 16 ) 2.78 (15.78) 3.08 (17.48) 3.08 (17.48) 3.08 (17.48) 3.85 (21.86) Floors over unheated space 4.67 (26.5) 4.67 (26.5) 4.67 (26.5) 5.02 (28.5) 5.02 (28.5) 13 Richard Kadulski Architect

9.36.2.6. Thermal Characteristics of Above Ground Opaque Assemblies Table 9.36.2.6.B Effective RSI-values with HRV Assembly Climate Zone (Heating Degree Days C) Zone 4 < 3,000 Zone 5 3,001 to 3,999 Zone 6 4,000 to 4,999 Zone 7A 5,000 to 5,999 Zone 7B 6,000 to 6,999 Ceilings 6.91 (39.23) 6.91 (39.23) 8.67 (49.2) 8.67 (49.2) 10.43 (59.2) Cathedral ceilings 4.67 (26.5) 4.67 (26.5) 4.67 (26.5) 5.02 (28.5) 5.02 (28.5) Walls (2x6 @ 16 ) 2.78 (15.78) 2.97 (16.86) 2.97 (16.86) 2.97 (16.86) 3.08 (17.48) Floors over unheated space 4.67 (26.5) 4.67 (26.5) 4.67 (26.5) 5.02 (28.5) 5.02 (28.5) 14 Richard Kadulski Architect

9.36.2.6. Thermal Characteristics of Above Ground Opaque Assemblies Effective R-value can be reduced at the heel of sloped roofs for no more than 1200 mm in from the exterior to allow for framing; and attic venting The minimum nominal R-value directly over the outside wall must be no less than RSI 3.52 (R-20) 15 Richard Kadulski Architect

9.36.2.4. Calculation of Effective Thermal Resistance of Assemblies Major structural penetrations through assemblies are permitted but total area must not exceed 2% Allowable penetrations include balcony slabs, beams, columns, and minor structural or ornamental elements. Pipes, ducts, through-wall equipment vents are considered minor penetrations and are not considered. 16 Richard Kadulski Architect

Parallel-Path Flow Method Differing rates of heat loss thru various components of Building Assembly 17 Richard Kadulski Architect

Parallel-Path Flow Method Need to determine cross sectional areas of the various components of Building Assembly A f A f A A A f c c 18 Richard Kadulski Architect

Calculating Assembly RSI values Continuous layers of insulation Isothermal planes method add RSI values of each layer Framed assemblies Isothermal planes method add RSI values of each Continuous layer PLUS Parallel-path flow method need to determine Effective Thermal Resistance (ETR) of Non-continuous layers 19 Richard Kadulski Architect

Effect of Thermal Bridging Where there is thermal bridging: Effective R < Nominal Where there is NO thermal bridging: Effective R = Nominal 20 Richard Kadulski Architect

9.36.2.4. Calculation of Effective Thermal Resistance of Assemblies RSI effective vs. RSI nominal RSI eff = RSI nom Include in calculation Repetitive structural members - Studs - Joists, lintels - Sills, plates Credit for adjoining unconditioned spaces Exclude from Calculations Minor penetrations - pipes, ducts - Packaged air conditioners - Shelf angles, anchors, fasteners Major structural penetrations - Balcony slabs, beams, columns, ornamentation, Provided: insulation is tight to penetrating element - Total area of all major structural penetration is limited to max 2% of wall area 21 Richard Kadulski Architect

Insulating Effect of the Surface Air Films RSI outside air film = 0.03 RSI inside air film = 0.11 Heat flow Up RSI outside air film = 0.03 RSI inside air film = 0.12 Heat flow Horizontal RSI inside air film = 0.12 Heat flow Horizontal RSI outside air film = 0.03 RSI inside air film = 0.16 Heat flow Down 22 Richard Kadulski Architect

Calculating Effective R-value: Walls above Grade Structure insulation Air film (interior) 0.12 0.12 1/2 gypsum board 0.08 0.08 Polyethylene barrier 0.00 0.00 2 x6 stud @ 16 o/c 1.19 3.52 7/16 OSB sheathing 0.11 0.11 Hollow backed vinyl siding 0.11 0.11 Air film (exterior) 0.03 0.03 Effective Thermal Resistance 2.89 (R-16.37) New Code Requirement zone 4 (less than 3,000 DDC): Eff. R 2.78 (R 15.78) R 20 batt Insulation 23 Richard Kadulski Architect

Parallel-Path Flow Method RSI parallel = 100 % area of framing (A f ) %area of cavity (A c ) + RSI f RSI c 24 Richard Kadulski Architect

Calculating Effective R-value: Walls above Grade Structure insulation Air film (interior) 0.12 0.12 1/2 gypsum board 0.08 0.08 Polyethylene barrier 0.00 0.00 2 x6 stud @ 16 o/c 1.19 3.52 7/16 OSB sheathing 0.11 0.11 Hollow backed vinyl siding 0.11 0.11 Air film (exterior) 0.03 0.03 Effective Thermal Resistance 2.89 (R-16.37) Code Requirement zone 4 (less than 3,000 DDC): Eff. R 2.78 (R 15.78) Code Requirement zone 5 (3,000 to 4,000 DDC): Eff. R 2.97 (R 16.86) with HRV Eff. R 3.08 (R 17.48) without HRV R 20 batt Insulation 25 Richard Kadulski Architect

Walls above Grade Code Requirement zone 5 & 6 (3,000 to 4,999 DDC): Eff. R 2.97 (R 16.86) with HRV Eff. R 3.08 (R 17.48) without HRV RSI effective R effective 2x6 @ 16 R-22 batt insulation 3.11 17.63 2x4 @ 16 R14 batt insul + R-5 rigid insulation 3.19 18.09 2x4 @ 16 R14 batt insul + R-7.5 rigid insulation 3.66 20.78 26 Richard Kadulski Architect

Calculating Effective R-value: Ceilings with Attic Space R 40 Blown Cellulose Raised Heel Air film (interior) 0.11 1/2 gypsum board 0.08 Polyethylene barrier 0.00 2 x4 bottom chord cavity 1.96 Continuous layer of cellulose 4.82 Air film (exterior) 0.03 Effective Thermal Resistance 7.00 Code Requirement zone 4 (less than 3,000 HDD): Eff. R 6.91 (R 39.23) 3 ½ cellulose 3 ½ wood 27 Richard Kadulski Architect

Calculating Effective R-value: Ceilings with Attic Space Raised Heel Air film (interior) 0.11 1/2 gypsum board 0.08 Polyethylene barrier 0.00 2 x4 bottom chord cavity 1.96 Continuous layer of cellulose 4.82 Air film (exterior) 0.03 Effective Thermal Resistance 7.00 R 40 Blown Cellulose New Code Requirement zone 5 (3,000-3,999 HDD): Eff. RSI 6.91 (R-39.23) with HRV Eff. RSI 8.67 (R-49.2) without HRV (requires R-50 cellulose) 28 Richard Kadulski Architect

Calculating Effective R-value: Ceilings with Attic Space Raised Heel Air film (interior) 0.11 1/2 gypsum board 0.08 Polyethylene barrier 0.00 2 x4 bottom chord cavity 1.96 Continuous layer of cellulose 6.59 Air film (exterior) 0.03 Effective Thermal Resistance 8.77 New Code Requirement zone 6 (4,000-4,999 HDD): Eff. RSI 8.67 (R-49.2) with HRV Eff. RSI 8.67 (R-49.2) without HRV (requires R-50 cellulose) R 50 Blown Cellulose 29 Richard Kadulski Architect

9.36.2.4. Calculation of Effective Thermal Resistance of Assemblies Appendix provides examples of calculations and data tables: Framing & cavity percentages for typical wood frame assemblies [Table A-9.36.2.4.(1)A] Factors for steel framing to address higher thermal bridging through steel studs [Table A- 9.36.2.4.(1)B] Thermal resistance values for common materials [Table A-9.36.2.4.(1)D] 30 Richard Kadulski Architect

9.36.2.4. Calculation of Effective Thermal Resistance of Assemblies Table A- 9.36.2.6.(1)A. presents the minimum nominal thermal resistance to be made up in a given wall assembly for it to achieve the applicable RSI value 31 Richard Kadulski Architect

9.36.2.4. Calculation of Effective Thermal Resistance of Assemblies Example using Table A-9.36.2.6.(1)A. Required effective RSI-value is 2.78 38 x 140 mm studs @ 406 mm o.c. with R-19 batt insulation. RSI value of structural assembly is 2.36. Minimum additional required is 0.42 Other components in wall assembly: Interior air film: 0.12 12.7 mm gyp board 0.08 12.7 mm ply sheathing 0.10 Rain screen cavity 0.15 stucco 0.013 Exterior air film 0.03 Total RSI of other components 0.49 32 Richard Kadulski Architect

HPO Illustrated Guide: Energy Efficiency Requirements for Houses in British Columbia 9.36.2.5. Continuity of Insulation Insulation must be continuous across the entire envelope but this does not mean continuous insulation across face. This applies to building components such as partitions, chimneys, fireplaces, and columns and beams that are embedded along exterior walls, but not to stud framing and ends of joists. Studs and joists in frame construction are dealt with by the calculation method for determining effective R-values. 33 Richard Kadulski Architect

9.36.2.5. Continuity of Insulation Article 9.36.2.5. (2) to (8) introduces relaxations for various details Article 9.36.2.5. (9) allows complete exemption to sentence (1) for three specific details: At junction between foundation wall and floor slab The perimeter of a floating slab-on-grade Foundation wall portion that supports masonry veneer 34 Richard Kadulski Architect

9.36.2.5. Continuity of Insulation Allowable exemptions: Required fire safety clearances Major structural components that penetrate the envelope (e.g. structural beams, balcony & canopy slabs) provided total area is not more than 2% of gross wall area Insulation is installed tight against the penetration 35 Richard Kadulski Architect

9.36.2.5. Continuity of Insulation 9.36.2.5.(2) minimizing thermal bridging Where a wall or structural element penetrates exterior envelope, it must be insulated. Note that continuity of air barrier must also be maintained at these details. 36 Richard Kadulski Architect

9.36.2.5. Continuity of Insulation 9.36.2.5.(2)(a) Minimizing thermal bridging where a wall or structural element penetrates exterior envelope, it must be insulated on interior (or exterior if element projects outward). 37 Richard Kadulski Architect

9.36.2.5. Continuity of Insulation 9.36.2.5.(2)(b) Minimizing thermal bridging of a wall or structural element at exterior envelope, where insulation is within plane of wall. 38 Richard Kadulski Architect

9.36.2.5. Continuity of Insulation 9.36.2.5.(2)(c) Minimizing thermal bridging of a wall or structural element at exterior envelope, where insulation is within plane of wall. 39 Richard Kadulski Architect

9.36.2.5. Continuity of Insulation 9.36.2.5.3. A masonry fireplace or flue on an exterior wall must be insulated to an effective R- value not less than 55% of that required for the exterior wall 40 Richard Kadulski Architect

9.36.2.5. Continuity of Insulation Insulation placement can be inside or outside; if there is a cross-over, the over lap must be 4 times the thickness of the wall i.e. for 8 wall, the minimum overlap will be 32 41 Richard Kadulski Architect

9.36.2.5. Continuity of Insulation 9.36.2.5. (6) mechanical, plumbing or electrical system components (such as pipes, ducts, conduits, cabinets, chases, panels or recessed heaters) within or parallel to wall assembly must be insulated to the same effective insulation level as required for the wall 42 Richard Kadulski Architect

9.36.2.5. Continuity of Insulation 9.36.2.5. (7) ducts, plumbing pipes, electrical or communication conduits placed within the insulated portion of a floor or ceiling assembly must have an effective insulation level not less than RSI 2.78 (R- 15.78) 43 Richard Kadulski Architect

9.36.2.5. Continuity of Insulation Ducts outside the heated envelope must be insulated to the same effective insulation level as required for walls above grade 44 Richard Kadulski Architect

9.36.2.5. Continuity of Insulation EXCEPTION: does not apply where cladding is masonry and foundation wall is insulated on the exterior [9.36.2.5.(9)c] 45 Richard Kadulski Architect

9.36.2.5. Continuity of Insulation 9.36.2.5.(8) Joints and junctions between walls and other building envelope components shall be insulated in a manner that provides an effective thermal resistance that is no less than the lower of the minimum values required for the respective adjoining components. 46 Richard Kadulski Architect

9.36.2.7. Fenestration, Doors & Skylights Fenestration and doors must have a U-value no greater than that in table 9.36.2.7.A, and skylights as in table 9.36.2.7B Windows & doors Zone 4 < 3,000 Climate Zone (Heating Degree Days C) Zone 5 3,001 to 3,999 Zone 6 4,000 to 4,999 Zone 7A 5,000 to 5,999 Zone 7B 6,000 to 6,999 Zone 8 >7,000 1.80 1.80 1.60 1.60 1.40 1.40 skylights 2.90 2.90 2.70 2.70 2.40 2.40 47 Richard Kadulski Architect

9.36.2.7. Fenestration, Doors & Skylights Site assembled, or site glazed factory-made products, curtain walls, and site built windows must be tested or calculated Garage vehicular doors must have nominal RSI 1.1. Access hatches to unconditioned space: the U-value not to exceed 2.6 48 Richard Kadulski Architect

9.36.2.7. Fenestration, Doors & Skylights Exceptions An exemption to requirements in table 9.36.2.7.A was made for site-built windows and glazed doors, but they must comply with properties laid out in Table 9.36.2.7.C Max U-value for glass block in an exterior wall must be not more than 2.9, and total area of glass block must not exceed 1.85 m (19.9 sq.ft.) One exterior door is permitted to have U-value of 2.6 (this allows for a feature entry door) Storm windows are exempt form these requirements 49 Richard Kadulski Architect

9.36.2.8. Assemblies In Contact With Ground Full height basement wall insulation required Top of foundation wall - up to 600 mm above grade is insulated as a foundation wall. Appendix table lists typical assemblies 50 Richard Kadulski Architect

9.36.2.8. Assemblies In Contact With Ground Effective R-values requirements vary whether HRV is installed or not Table 9.36.2.8.A. or 9.36.2.8.B Example [required RSI effective is 1.99]: Concrete foundation wall, 38x89 (2x4) furring, RSI-2.11 (R- 12) insulation. From table A-9.36.2.8 (1)A the effective R-value of assembly is 1.79. Minimum additional required is 0.20 This can be made up by installing 12.7 mm gyp board (0.0775) plus interior air film (0.12) 51 Richard Kadulski Architect

9.36.2.8. Assemblies In Contact With Ground Heated floor slabs must be insulated under entire area, including the edges Floating slabs must be insulated under entire floor slab, but not under integral perimeter footing, but skirt insulation is required to same value as under the slab 52 Richard Kadulski Architect

9.36.2.8. Assemblies In Contact With Ground Floor slab insulation depends whether or not it is a heated slab, and above or below frost line If entire floor fits into two categories, the more restrictive applies. 53 Richard Kadulski Architect

9.36.2.8. Assemblies In Contact With Ground Unheated floor slabs must be insulated min. 1.2m horizontally or vertically down from its perimeter, with a thermal break along edge of slab a min. 50% of required insulation 54 Richard Kadulski Architect