BIU Büro für integrierten Umweltschutz

Similar documents
Perspectives on Sustainability, Going Green EU Regulation VOC s, testing and the implications for adhesives and sealants

GN22: BREEAM and HQM recognised schemes for emissions from construction products

LEED. A new challenge for low VOC emitting materials. and BREEAM, HQE, DGNB

Metal Wall Cladding Lindner Free 910 Environmental Product Declaration acc. to ISO Holder of the declaration

LIMIT VALUES FOR VOC EMISSIONS FROM CONSTRUCTION AND DECORATIVE PRODUCTS AROUND THE GLOBE

The 411 on emitting materials Designing Healthy Interiors A. Costello, P.E., LEED-AP

GEV Classification Criteria

VOC emissions testing - new approaches for LEED, and for CE marking in Europe

Contractor's Letter of Assurance

LEED Green Building Leadership. LEED Data. Green Building Leadership

Introduction HEALTHY HOMES INDOOR AIR QUALITY AND MATERIALS SELECTION TECHNICAL PAPER. March 2017

GEV Classification Criteria

Contractor's Letter of Assurance

Component Goal Performance Measurement Unit. meet the sustainability criteria. described below. described below. from landfills.

Lindner Metal Ceiling System LMD-E Environmental Product Declaration acc. to ISO Holder of the declaration

LEED version 5 PRODUCT DATA FOR CERTIFICATION MINERAL PLUS

Understanding Requirements for VOC Content vs. Emissions for Adhesives

BUILDING FOR OUR FUTURE

LEED v4 Technical Bulletin Building Design + Construction

DGNB CORE 14 PRODUCT DATA FOR CERTIFICATION ROCK MINERAL WOOL WITH ECOSE TECHNOLOGY

Low Emitting Materials

Lindner Metal Ceiling System LMD-B Environmental Product Declaration acc. to ISO Holder of the declaration

LEED v4 Technical Bulletin Building Design + Construction

A. The project is intended to achieve LEED Certification at the Silver Level per the U.S. Green Building Council LEED for Schools 2007 rating system.

TEXAS FACILITIES COMMISSION Edit Date: 4/13/2012 ARCHITECTURAL/ENGINEERING GUIDELINES

Product Rating. BREEAM Category BREEAM Assessment Issue Max. influenced score Fulfillment. Emissions from building products 1 Credit

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION SUSTAINABILITY CERTIFICATION REQUIREMENTS LEED NC V3

Produktdeklaration - DGNB Neubauversion Büro- und Verwaltungsgebäude (NBV15) Venetian Blind (Lamisol, Solomatic, Aluflex)

Chapter 8: Indoor Environmental Quality

Note year for Reference as Specified in the LEED V Manual.

LEED And Your Indoor Environment

Lindner Heated/Chilled Metal Ceiling System Plafotherm E (V2A) Environmental Product Declaration acc. to ISO 14021

Comparison of emission specifications in the US and in Europe

LEED v4 Building Design and Construction Quiz #8 EQ

LEED 2009 Green Building Rating Systems Information Sheet 06/03/2009

UNIVERSITY OF ROCHESTER DIVISION 01 SPECIFICATIONS November 4, 2013 SECTION SUSTAINABLE DESIGN REQUIREMENTS - LEED FOR NEW

Product Declaration - DGNB New Construction Office and Administration Buildings (NBV12) Automatic swing door drive family Powerturn

VOC Emissions under EU Construction Products Regulation

CLIMAFLEX STABIL & EXZENTROFLEX COMPACT

Sugen Building 3 LEED-CI Pilot Project

SPECIAL ENVIRONMENTAL REQUIREMENTS FOR A CALIFORNIA STATE OFFICE BUILDING

Lindner Heated/Chilled Metal Ceiling System Plafotherm B (Cu) Environmental Product Declaration acc. to ISO 14021

SECTION SUSTAINABLE DESIGN REQUIREMENTS LEED FOR NEW CONSTRUCTION AND MAJOR RENOVATIONS

BREEAM INTERNATIONAL NEW CONSTRUCTION PRODUCT DATA FOR CERTIFICATION GLASS MINERAL WOOL ECOSE

Cornell Rolling Counter Fire Doors Comprehensive Guide to Earning LEED v4 Credits

SECTION (SECTION 09650) - RESILIENT FLOORING SPECIFIER NOTE:

Max Frank GmbH & Co. KG PRODUCT CHARACTERISTICS. Product Rating. LEED Category LEED Credit max. influenced score Degree of fulfillment %

Product Declaration - LEED 2009 New Construction And Major Renovations NC & CS

Aluminium Frame Doors ATB 68 Environmental Product Declaration acc. to ISO Holder of the declaration

Indoor Air Quality (IAQ) Requirements

Our aim is to ensure that indoor air is of sufficient quality not to adversely affect users health and well-being.

Environmental Compliance Testing of Textile Fabric Product

CONTRIBUTION OF NORA PRODUCTS TO LEED v4

LEED LEED. Leadership in Energy and Environmental Design. A voluntary, consensus-based. high-performance, sustainable buildings and neighborhoods

Danish Indoor Climate Labelling

SECTION SUSTAINABILITY CERTIFICATION REQUIREMENTS LEED HC V3

HUMAN HEALTH & MATERIAL CONSIDERATIONS IN LEED V4

Produkt Declaration - LEED 2009 New Construction And Major Renovations NC & CS

Environmental Compliance Testing of Textile Fabric Product

HELLA Sonnen - und Wetterschutztechnik GmbH. Contribution within the framework of BREEAM certification. Management. Date:

toxicity/ieq: Refer to Division 09 (9) for information on resilient flooring and carpeting. Refer to Division 05 (5) for information on metals.

LEED for Commercial Interiors

Green Building Practice Summary 03/17/2011

AirRenew Gypsum Board Products - Frequently Asked Questions

CONTRIBUTION OF NORA PRODUCTS TO LEED v4

EGO Dichtstoffwerke GmbH & Co. Betriebs KG

LEED TECHNICAL DATA SHEET

Lindner Heated/Chilled Metal Ceiling System Plafotherm B (V2A) Environmental Product Declaration acc. to ISO 14021

LEED Best Practices Save $$$

CE Option 1 and 2 - Provide the pre-development site run -off rate (cfs) CE Option 1 and 2 - Provide the pre-development site run -off quantity (cf)

ECOproduct. Method for selecting environmentally friendly materials and products in construction projects. Last updated

CAMP BLANDING JOINT TRAINING CENTER CONSTRUCTION AND FACILITY MANAGEMENT OFFICE ARCHITECT S PROJECT # CFMO PROJECT #

points and are GREENGUARD Indoor Air Quality Certified. Suitable for both horizontal and vertical applications, Corian solid surfaces and Zodiaq

VOCs and Solvent Cements

Guide to green public procurement of

Product Declaration - DGNB Neubauversion Büro- und Verwaltungsgebäude 2012 NMC S.A. CLIMAFLEX. Product Rating DGNB Criteria

TIMBER FLOORING ADHESIVES

HEALTHY LIVING. invisible but measurable

Produkt Declaration - LEED 2009 New Construction And Major Renovations NC & CS

LaGyp TM Gypsum Boards

Annex to the Accreditation Certificate D-ZE

Analysis of VOCs & Formaldehyde

UL ENVIRONMENT TECHNICAL BRIEF CARB FORMALDEHYDE RISKS

STC MANUFACTURER STEEL DOOR WITH PLYWOOD 3/4

QT 4003 (3mm), QT 4005 (5mm) & QT 4010 (10mm)

Thermiser Insulated Rolling Doors Comprehensive Guide to Earning LEED v4 Credits

Multi-Institutional Academic Health Science & Research Center Evansville, IN

CONTRIBUTION OF NORA PRODUCTS TO LEED v4

SECTION (SECTION 06160) SHEATHING SPECIFIER NOTE:

Indoor Environmental Quality Policy

Produkt Declaration - LEED 2009 New Construction And Major Renovations NC & CS

Annex II. Declarations

Ecole Connaught Community School Welcomes. CaGBC Sask Chapter Members & Colleagues

SAS International GSAS / QSAS compliance

Transcription:

Eurofins VOC Seminar 2015 for Manufacturers at Frankfurt Airport 28 th October 2015 Eco-friendly and low emitting building products for sustainable and green buildings certified by LEED, BREEAM & DGNB Dr. Michael H. Rieß DGNB- / BREEAM-in use Auditor

Profile DGNB-Auditor, BREEAM in-use auditor DGNB-founding member, DGNB technical commitee, head of expert group on construction materials and hazardous substances Systemexpert of BREEAM.DE Services Auditing of Building Certification Harmful building materials, deconstruction planning, environmental sound construction side, green building materials, indoor air quality, environmental data sheets More than 40 DGNB- & LEED-reference projects

Outline Common principles of BREEAM, LEED & DGNB Low-VOC-construction materials what for? BREEAM Hea 02 VOC emission levels of products & buildings LEED Low emission products and indoor air quality assessment DGNB Low VOC products (ENV1.2) and indoor air quality (SOC1.2) Conclusions Recommendations

Certification schemes for buildings Common Principles of the most recent versions Defined criteria for the planning, building and documentation of sustainable constructions, life-cycle costs, advanced comfort and efficient installations (energy, waste, recycling, ) Credits or ratings for the proofed fulfillment of advanced standards Adaption of the criteria to the type of building (e. g. office, school, industrial, domestic ) Healthy indoor air quality as an prerequisite or for additional credits based on - indoor air quality testing - usage of low-voc-materials Certificate issued by NSO (National Scheme Operator)

Low VOC-materials what for? Low-VOC-materials show reduced emission levels of volatile organic compounds (VOC) usually with boiling points in the range of 50 100 up to 240 260 C not necessarily are also green (e. g. PU-Foam-Adhesive, EC1+, Difluroethan blowing gas (GWP = 124), <10% Dimethylether) are relevant for the building of healthy rooms with low VOC- or low Formaldehyde-burden are if solvent free - environmentally benefical with respect to Photochemical Ozone Creation Potential (POCP)

BREEAM Hea 02 Indoor Air Quality BREEAM Hea 02 (2014)

BREEAM Hea 02 Indoor Air Quality Aim of BREEAM Hea 02 (2014) To recognise and encourage a healthy internal environment through the specification and installation of appropriate ventilation, equipment and finishes Assessment criteria Minimising sources of air pollution (4 credits) 1. Indoor air quality plan (= how to minimize indoor air pollution) 2. Ventilation regime in order to e. g. minimze CO2-levels 3. VOC emission levels (products) 4. VOC emission levels (in the building post construction) Adaptability - potential for natural ventilation (1 credit)

BREEAM Hea 02 Indoor Air Quality - Products VOC emission levels (products) - 1 credit / 1,5% of the total score) for Decorative paints and varnishes Wood panels with organic or cementitous binders Timber structures (e. g. glue laminated) Wood flooring (e. g. parquet) Resilient textile & laminated floor coverings (e. g. vinyl, cork, rubber...) Suspended ceiling tiles Flooring adhesives Wall coverings

BREEAM Hea 02 Indoor Air Quality - Products Required product performance: Compliance to Decopaint Directive 2004/42/EU for paints and varnishes Compliance to Formaldehyde E1-class for wood panels timber structures wood flooring resilient textile and laminated floor coverings (e. g. carpet...) suspended ceiling tiles

BREEAM Hea 02 Indoor Air Quality - Products Required product performance: No carcinogens and no sensitizers as defined in Annex of EN 13999-1 are emitted in a ventilated test chamber after 1 day (EN 13999 parts 2, 3, and 4): Determination of carcinogenic and sensitizing - VOCs - volatile aldehydes & diisocyanates for flooring adhesives

BREEAM Hea 02 Indoor Air Quality - Products Required product performance: Low emissions of formaldehyde and of vinyl chloride monomer, complying with standards EN 233, EN 234, EN 259, EN 266 Migration of heavy metals and other toxic substances complies with above mentioned standards for wall coverings

BREEAM Hea 02 Indoor Air Quality - Building VOC emission levels in the building post construction (1 credit / 1,5% of the total score) Measured in the building post construction but preoccupancy Standards are linked to the UK-Building Regulation requirements Testing is not obligate Formaldehyde 100µg/m 3 averaged over 30 min. (WHO guidelines) TVOC concentration level <300µg/m 3 over 8 hours If the levels are not met, the project team confirms the measures that have, or will be taken, to reduce the levels to within the limits

BREEAM Hea 02 Indoor Air Quality - Summary Low-VOC in BREEAM New Construction Low-VOC-products only have to comply to the legal standards Indoor-air-limits for Formaldehyde and TVOC in the building are quite strict Indoor-air-testing is an option to get a credit rather then obligate If the limit values are not met, project team can agree on measures like ventilation in accordance to the IAQ-plan... ; additional indoor air testing for success control of these measures are not necessary.

LEED v4 - Indoor Air Quality

LEED v4 - Low-emitting materials Intent of credit (v4) - 3 Credit-Points To reduce concentrations of chemical contaminants that can damage air quality, human health, productivity, and the environment. Assessment criteria Different materials must meet different requirements for compliancy to these credits If some products in a category do not meet the criteria, project teams may use the budget calculation method (here not addressed)

LEED v4 - Low-emitting materials Extended scope effective from v4 for interior materials Compliance of interior finishes may be demonstrated in assemblies with multiple layers in combination, or in each system individually Included consideration of furniture emissions New referenced standards to address international projects and new product requirements Ceilings and insulations are now included in the requirements Emissions requirements for on-site, wet-applied, full- spread products measured via chamber tests in air are now included. VOC content limits for on-site, wet-applied products are still required

LEED v4 - Low-emitting materials VOC in can or emission limits for Interior paints and coatings applied on site Interior adhesives and sealants applied on site (including flooring adhesive) Flooring Composite wood Ceilings, walls, thermal and acoustic insulation Furniture (included in calculations if part of scope of work)

LEED v4 - Low-emitting materials Required product performance: VOC-limit of SCAQMD rule 1113, effective June 3, 2011 or (outside NA) compliant to national regulations (e. g. 2004/42/EU) for paints and coatings wet-applied on site VOC-limit of SCAQMD rule 1168, effective July 1, 2005 or (outside NA) compliant to national regulations (e. g. AgBB) for adhesives and sealants wet-applied on site Formaldehyde emissions not to exceed 0,05ppm as tested following either EN-717-1:2004, ISO 16000-3: 2010... for wood-based panels (= E 0,5 )

LEED v4 - Low-emitting materials Required product performance: Emission testing under California Department of Public Health (CDPH) Standard Method v1.1 2010, default scenario is the private office scenario, state the range of total VOCs after 14 days (336 hours): 0.5 mg/m 3 >0.5 5.0 mg/m 3 5.0 mg/m 3 or (outside NA) emission levels are compliant to national regulation (e. g. AgBB, French VOC) for flooring composite wood ceilings, walls, thermal, and acustic insulation furniture, if part of the scope of work

LEED v4 Indoor air quality assessment Intent of credit (v4) Possible 2 Credit-Points To establish better quality indoor air in the building after construction and during occupancy Assessment criteria Building flush-out (1 Point) before or during occupancy Before: Supplying a total air volume of 4267m 3 of outdoor air per square meter of gross floor area while maintaining an internal temperature between 15 to 27 C and relative humidity 60% Air testing (2 Points) after construction ends and before occupancy using protocols consistent to specific EPA-, ASTM- or ISO-Standards

LEED v4 Indoor air quality assessment VOC- & Formaldehyde emission levels in the building (2 credits) Measured in the building post construction but preoccupancy Testing is not obligate Formaldehyde 33µg/m 3 (ASTM or ISO) TVOC concentration level <500µg/m 3 (ASTM or ISO) Maximum levels also for PM10, PM2,5, Ozone & CO Target concentrations for individual VOCs linked to EPDH v1.1 but Phenol 200µg/m 3 > RW1 (20µg/m 3 ) Risk for health hazard Naphthalene 9µg/m 3 > RW2 (3µg/m 3 ) Clean up efforts RW: German Indoor Guide Values

LEED v4 - Indoor Air Quality - Summary Low-VOC in LEED New Construction Low-VOC-products only have to comply to the legal standards exept wood-based panels (E 0,5 -quality) Indoor-air-limits for Formaldehyde and TVOC in the building are quite strict Indoor-air-testing is an option to get a credit rather then obligate Individual VOC-target limits are not ambitious; some are above the German guide values RW1 or even RW2

DGNB 2015 Low-VOC-products & Indoor Air Quality

DGNB 2015 - ENV1.2 & Low VOC-products Low-VOC-materials are adressed with respect to human health (= indoor air quality) as well as with respect to environmental protection (POCP) (= Photochemical Ozone Creation Potential (POCP)

DGNB 2015 - ENV1.2 & Low VOC-products Principles Requirements for 45 product categories (mixtures and articles) applied of site (only few) and on site - up to 3,4% of total scoring Criteria have been developed in cooperation with industrial federations of building product manufacturers Four quality classes of product requirements 1. Legal standard e. g. Decopaint-Directive (2004/42/EU) 2. Actual technical state e. g. solvent reduced laquere 3. Advanced standard e. g. water-based laquer 4. High end e. g. RAL-UZ14a (or equiv.), dispersion laquer VOC-content limits or emission standards (e. g. EMICODE, GUT)

DGNB 2015 - ENV1.2 & Low VOC-products Required product performance (only quality classes 3&4, for interiors) VOC, SVOC and biocides in can for paints and coatings, impregnations (e. g. natural stone) anti corrosive coatings (for the product or the coating system) bitumen pre-coat parquet oil EMICODE EC1 / EC1-R or EC1+ / EC1-R+ or RAL-UZ for adhesives sealers levellings and adhesives for floorings and wall finishes GUT-Label or RAL-UZ (28d TVOC 1/10 of AgBB) for textile & resilient floorings

DGNB 2015 - Indoor Air Quality

DGNB 2015 - Indoor Air Quality Assessment criteria Air exchange rate: Realised ventilation rate - naturally or mechanically according to EN15251 Indoor air testing latest four weeks after construction ends, without furniture and fixtures, before occupancy using protocols consistent to ISO-16000 series - defined number of rooms - representative rooms - each type of outfit - all tested rooms have to meet the requirements - usually 3 to 6 rooms have to be measured

DGNB 2015 - Indoor Air Quality Evaluation criteria = Knock-out scoring

DGNB 2015 - Summary Low-VOC in DGNB New Construction (maximum score 5%) Low-VOC-products for higher DGNB-ratings have to comply to the most advanced VOC- or emission-standards Indoor-air-limits for Formaldehyde and TVOC in the building are strict Indoor-air-testing is obligate and compliance to minimum levels have to be demonstrated (knock-out-criteria) Individual VOC-target limits are much below the German guide values RW1 or even RW2 Low-VOC-product standard and indoor-air limits are balanced

Conclusions & recommendations Low-VOC in BREEAM, LEED & DGNB - conclusions BREEAM and LEED already offer credits for the use of legally complient products (except E 0,5 wood based panels); DGNB is asking for the most advanced product standards BREEAM- and LEED-indoor-air testing is voluntary; for DGNB compliance to minimum indoor-air-quality standards is an prerequisite (knock-out criteria!) Recommendations Legal compliance testing for products is a chance to check and proof compliance to advanced standards Use the emission test results for product quality assurance and development Airtight facades, short construction phases and the increase in the use of building chemicals will facilitate the need for low emission materials Make available enivironmental product data sheets for material vetting

Thank you for your attention!