The Manufacture of Sterile Pharmaceuticals and Liquid Medical Devices Using Blow-Fill-Seal Technology

Similar documents
Aseptic Process Validation

Blow-Fill-Seal Machine

FILLING YOUR NEEDS DECISION-MAKING SUPPORT FROM THE INVENTORS OF BLOW-FILL-SEAL TECHNOLOGY

Health Products and Food Branch Inspectorate

Chuck Reed at Weiler Engineering, Inc compares aseptic blow-fill-seal technology with traditional aseptic processing of pharmaceutical liquids

Improving Process Quality of Pharmaceutical Liquids Aseptic Blow/Fill/Seal Technology vs. Traditional Aseptic Processing

Challenges in Archiving SharePoint documents to a file server / file share

ISO INTERNATIONAL STANDARD

SAP BUSINESSOBJECTS PLANNING AND CONSOLIDATION 10.0, VERSION FOR SAP NETWEAVER STARTER KIT FOR IFRS SP1. Simplified Configuration Description

BFS IOA BFS Training 2018 Kunming Qualification and Validation of a BFS-Installation including CIP/SIP

Compressed air. Part 1: Contaminants and purity classes BS ISO :2001 BRITISH STANDARD

Thermoforming packaging machine R 145 with MULTIVAC Clean Design. Maximum process reliability and cleanroom suitability

Streamlined Blow-Fill-Seal Insertion Technology Increases Flexibility and Safety in Aseptic Packaging of Pharmaceutical Liquids

Overview and Introduction Annex 1 Revision

Managing e-business Projects

Points to Consider for Aseptic Processing Part 2 May 2016

Ultra high-speed switching Voltage clamping Protection circuits Mobile communication, digital (still) cameras, PDAs and PCMCIA cards.

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Plastics collapsible containers for human blood and blood components Part 1: Conventional containers

illatu/fill/seal Packaging System

Benchmark Test for Clear PET Resin and Molded Articles

Asset Identification

Plastics Blow-moulded polypropylene containers for packaging of liquid foodstuffs

Sheet Metal Forming FUNDAMENTALS. Edited by Taylan Altan and A. Erman Tekkaya

Annex A2. Guidance on Process Validation Scheme for Aseptically Processed Products

Specification for Pipeline Valves

ISO 604 INTERNATIONAL STANDARD. Plastics Determination of compressive properties. Plastiques Détermination des propriétés en compression

Waypoints Sequence Extension API

Biogas Plant Construction Guide

ISO INTERNATIONAL STANDARD. Aseptic processing of health care products Part 4: Clean-in-place technologies

INTERNATIONAL PROJECT MANAGEMENT:

Steel Pipelines Crossing Railroads and Highways

Critical Guidance Protocol for Clear PET Resin and Molded Articles

About This Book. Why is this topic important? What can you achieve with this book? How is this book organized?

Transfusion equipment for medical use. Part 5: Transfusion sets for single use with pressure infusion apparatus

Shipyard Cost Estimating (Using PERCEPTION Version 7)

Critical Guidance Protocol for Clear PET Articles with Labels and Closures

Diagnosing and Changing Organizational Culture

I was always searching for new techniques to produce biogas from animal and kitchen organic waste at house level suitable for any urban area

Plastics collapsible containers for human blood and blood components. Part 1: Conventional containers

Survey Reports Document Version: 1.1 November 2015

Linings of Aboveground Petroleum Storage Tank Bottoms API RECOMMENDED PRACTICE 652 FOURTH EDITION, SEPTEMBER 2014

Elementary Materials Science

AWS A5.35/A5.35M: 2015-AMD1 An American National Standard. Specification for Covered Electrodes for Underwater Wet Shielded Metal Arc Welding

Packaging System for Liquids. Blow-Fill-Seal Technology

Packaging Form Comparison:

ISO INTERNATIONAL STANDARD

92831 TEL: (714) FAX:

Oracle E-Business Suite Development and Extensibility Handbook

Table 1. Quick reference data Symbol Parameter Conditions Min Typ Max Unit V RRM

Flexible Food Packaging. Questions and Answers

Processing of 8-well strips under vacuum

Changes to the MCR &Tips for Implementation: The Minimum Competency Code 2011 Lisa Knox Enterprise Risk Services 17 November 2011

Review Validation of aseptic processes for pharmaceuticals

FDA s Guidance for Industry

Technical Information. High Performance Materials. Processing Durethan by extrusion blow molding

Microsoft Dynamics GP Business Portal. Project Time and Expense User s Guide Release 3.0

t e g y s t r a i m p l e m e n t a t i o n M E N TA L L A N G U A G M O D E L S S T O R Y M A P S S O C I A L M E D I A

Edited by Konrad Herrmann

Media Fill A Process Simution. Presented By Shikha Chauhan

Engineering Properties of Magnesium Alloys

Downstream handling and Secondary Packging for BFS containers some considerations

ISO INTERNATIONAL STANDARD. Aseptic processing of health care products Part 4: Clean-in-place technologies

Installation checklist for Roxtec rectangular frames

Commonsense Talent Management

Ultraviolet microbiological water treatment systems

AWS D10.18M/D10.18:2018 An American National Standard. Guide for Welding Ferritic/Austenitic Duplex Stainless Steel Piping and Tubing

ISO INTERNATIONAL STANDARD

Table 1. Quick reference data Symbol Parameter Conditions Min Typ Max Unit V RRM

WIND BLADE REPAIR. Study Guide

Guidance for Industry

PLAINSCAPITAL BANK APPLE PAY TERMS AND CONDITIONS - BUSINESS

Using your logo with Your Home Loan Toolkit

VALIDATION OF ASEPTIC PROCESSES

AWS D14.3/D14.3M:2010 An American National Standard. Specification for Welding Earthmoving, Construction, and Agricultural Equipment

911 Disclosure and Acknowledgment. Option 1 No 911 Service. Option Service Agreement

APPLE PAY TERMS & CONDITIONS

ISO INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

ISO Road vehicles Cleanliness of components of fluid circuits Method of extraction of contaminants by agitation

General Information on the Assembly and Solder Pad Design of the DRAGON Family Application Note

ISO INTERNATIONAL STANDARD. Petroleum and natural gas industries Downhole equipment Packers and bridge plugs

SURFACE VEHICLE STANDARD

ISO INTERNATIONAL STANDARD. Cleanrooms and associated controlled environments Part 4: Design, construction and start-up

ISO INTERNATIONAL STANDARD. Plastics Determination of Charpy impact properties Part 1: Non-instrumented impact test

MAGBIO. PROTOCOL Contents. Dye Terminator Removal Clean Up. Magnetic beads based chemistry No centrifugation or filtration

Ultraviolet microbiological water treatment systems

IF YOU DO NOT AGREE TO THESE TERMS, DO NOT DOWNLOAD, INSTALL OR USE BSS.

ISO INTERNATIONAL STANDARD

ISO/IEC INTERNATIONAL STANDARD. Systems and software engineering System life cycle processes IEEE

Package LGA6x FixPitch- / FreePitch-Sensors

Q8 Pharmaceutical Development

Bionano Tools v1.3 Release Notes

WE BLOW-FILL-SEAL FOR YOU

Water Treatment Plant Residuals Field Guide

SAP FINANCIAL CONSOLIDATION 10.0 STARTER KIT FOR IFRS SP5. Simplified Configuration Description

Installation Guide Document No BioSafe Cleanroom Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised December 2017

Data Collection Guidelines

Transcription:

BFS International Operators Association The Manufacture of Sterile Pharmaceuticals and Liquid Medical Devices Using Blow-Fill-Seal Technology Points to Consider K. Downey, M. Haerer, S. Marguillier, P. Åkerman

Former editions: 1st edition September 1993 by S. Probert, S. Forrester-Coles 1st main revision September 1998 (general update) 2nd main revision October 2002 (general update) by A. Löfgren small revision January 2003(small revision/update of integrity testing sections) by A. Löfgren 3rd main revision April 2007 (update in general and regarding the revised FDA guidance) by E. Dewhurst 4th main revision Nov. 2011/March 2012 (general update, Media Fills, SIP, implementation of rotary machine type 4010) by K. Downey, M. Haerer, S. Marguiller, P. Åkerman 5th corrected version December 2016 The pictures on the front cover are sponsored by Brevetti Angela, Rommelag and Weiler Engineering. Bibliographic data available from the German National Library The German Library catalogs this publication in the German National Bibliography; detailed bibliographic information can be found on the internet website: http://dnb.ddb.de. The Manufacture of Sterile Pharmaceuticals and Liquid Medical Devices Using Blow-Fill-Seal Technology: Points to Consider ISBN 978-3-87193-440-7 2017 ECV Editio Cantor Verlag für Medizin und Naturwissenschaften GmbH, Aulendorf (Germany). All rights, in particular those of duplication, distribution, and translation are reserved by BFS International Operators Association c/o Melitek A/S, DK-4840 Nørre Alslev, and the publisher without any limit in time. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise without the prior written permission of the publisher. The absence of the symbol after any name does not imply that this name is not under trademark protection. ECV Editio Cantor Verlag on the internet www.ecv.de Typesetting: Reemers Publishing Services GmbH, Krefeld Printing: HOLZMANN DRUCK GMBH & CO. KG, Bad Wörishofen

Contents 3 Contents Disclaimer 7 1. INTRODUCTION 9 2. OBJECTIVE 11 3. BFS PROCESS OUTLINE 12 3.1 SHUTTLE TYPE MACHINES 12 3.2 ROTARY FILLING MACHINES 14 3.3 ADDITIONAL APPLICATIONS 16 4. ADVANTAGES & CHALLENGES OF BLOW-FILL-SEAL TECHNOLOGY 18 4.1 ADVANTAGES 18 4.2 CHALLENGES 19 5. DESIGN 21 5.1 PRODUCT DESIGN 21 5.1.1 Aseptic processing versus terminal sterilisation 21 5.1.2 Terminal sterilisation 21 5.1.3 Polymer 22 5.1.4 Container design 23 5.1.5 Secondary packaging 24 5.2 EQUIPMENT DESIGN 25 5.2.1 General 25 5.2.2 Control of critical zone environment 26 5.2.3 Air shower design (shuttle type machines) 27 5.2.4 Product pathway 28 5.2.5 Mould design 28 5.2.6 Deflashing 29 5.2.7 Equipment Monitoring 29 5.2.8 Container closure system leak detection 30 5.3 FACILITY DESIGN 31 5.3.1 Aseptic Processing Area (APA) 31

4 Contents 5.3.2 Support areas 34 5.3.3 Polymer storage and distribution 34 5.3.4 Utilities 35 6. QUALIFICATION AND VALIDATION 36 6.1 PRODUCT VALIDATION 36 6.1.1 Container/Closure integrity testing 36 6.1.2 Process capability 36 6.2 EQUIPMENT VALIDATION 37 6.2.1 Extruder 37 6.2.2 Air Flow 38 6.2.3 Clean in Place (CIP) of the product pathway 38 6.2.4 Sterilisation in Place (SIP) of the product pathway 38 6.2.5 Process simulation (media fill) for aseptic filling lines 40 6.2.6 Moulding and filling system 44 6.2.7 Downstream process 44 6.2.8 Controls 44 6.2.9 Filtration 45 6.3 FACILITY VALIDATION 45 7. OPERATION 46 7.1 PROCESS OPERATION 46 7.1.1 In-process controls 46 7.1.2 Start-up procedures 47 7.1.3 Interventions 47 7.1.4 Environmental monitoring 48 7.2 EQUIPMENT OPERATION 51 7.2.1 Sanitisation of critical surfaces 51 7.2.2 Equipment cleaning 51 7.2.3 Cooling systems 51 7.2.4 Extruder control 51 7.2.5 Maintenance 52 7.3 FACILITY OPERATION 52 7.3.1 Gowning 52

Contents 5 7.3.2 Polymer handling 53 7.3.3 Use of regrind polymer material 53 7.3.4 Training 53 8. RISK ASSESSMENT 55 8.1 PRODUCT CONTAMINATION 55 8.2 OTHER PRODUCT QUALITY ATTRIBUTES 57 APPENDIX 59 GLOSSARY 60 GUIDANCE REFERENCES 62 GENERAL REFERENCES 63

7 Disclaimer This document was produced and is disseminated by the Pharmaceutical Blow-Fill-Seal International Operators Association (the Association ) as a service of the Association solely for the convenience of its members. These Points to Consider are an effort to provide a compilation of current Blow-Fill-Seal ( BFS ) manufacturing operations and practices. In producing this document, the Association has attempted to reflect accurately the current state of BFS manufacturing operations on a worldwide basis. However, the Association makes no claim whatsoever regarding these Points to Consider to any user of these Points to Consider, including without limitation, any claim that the document: contains no errors covers all actual or potential aspects of BFS operations is in all instances completely up to date in its description or outline of current practice represent the unanimous [or consensus] opinion of the BFS industry or the Association members reflects the requirements of all applicable laws All use of these Points to Consider shall be at the user s sole risk. This document, and the procedures contained in the Points to Consider, has not been reviewed by, nor have they been endorsed by, filed or registered with, any governmental agency having jurisdiction over these matters. This document do not create any rights for, or confer any rights upon, any person, nor do they operate to bind the international and national authorities (FDA, European Commission, any other federal, state or local regulatory agency), or the public, in any manner. Where these Points to Consider reiterate a requirement imposed by statute or regulation, the requirement s having the force and effect of law is not changed or affected in any way by virtue of its inclusion in this document, nor does such inclusion give these Points to Consider the force of law.

8 Disclaimer The mention in this document of commercial products, their sources, or their use in connection with matters described in the Points to Consider is not, and is not to be construed as, either an actual or implied endorsement of such products by the Association. The Association shall not be liable for, and disclaims all liability for, any and all losses, costs or damages, however arising, whether direct or indirect, incidental, consequential, punitive or exemplary, incurred as a result of or in connection with any person s following, or failing to follow, these Points to Consider. The BFS process is a technical one and appropriate and adequately trained expert personnel must be employed at each stage of the BFS process.

9 1. INTRODUCTION Blow-Fill-Seal (BFS) technology has been used for pharmaceutical and liquid medical device manufacturing since the 1970s. This processing technology has become accepted worldwide for both aseptic and terminally sterilised liquid products and is currently used in more than 50 countries throughout the world. BFS technology lacks harmonisation and specific standards on a worldwide basis. As a result, the technology has developed in an isolated fashion, with each company and each regulatory agency establishing its own interpretation of acceptable BFS practice. In 1989, the Pharmaceutical Blow-Fill-Seal International Operators Association (BFS IOA) was established as an interest group of pharmaceutical and associated companies actively involved with BFS processing. The Association was formed to provide its members with an opportunity to exchange ideas and opinions, and to formulate agreement on operating standards. It also provides a forum to speak with a unified voice to machine manufacturers, commercial suppliers, and regulatory bodies. The Association has expanded worldwide and now has over 60 member companies. In an attempt to establish a common understanding of acceptable practice in BFS processing, the Association first published a Points to Consider for Pharmaceutical Blow-Fill-Seal Manufacturing Operations (PTC) document in September 1993. The document addressed points specific to BFS processing but also covered many more general areas. The current PTC document focuses on issues specific or unique to BFS technology and has undergone periodic review and systematic updates since its inception. This document is the culmination of several reviews during 2010 and 2011 and the most current version is from March 2012.

10 1. INTRODUCTION The document is structured into 3 main sections covering design, startup/validation, and routine operation. Within each section, Product, Equipment and Facility are considered. Design Initial start-up Routine operation Product ü ü ü Equipment ü ü ü Facility ü ü ü

11 2. OBJECTIVE The objective of the Points to Consider document is to provide recommendations specific to the operation of Blow-Fill-Seal technology for the manufacture of sterile pharmaceuticals and liquid medical devices. The principles of BFS technology as applied to filling are considered to be the same in terms of machine process for both aseptically filled and terminally sterilised products. This document provides information to supplement and to assist with interpretation of international standards and regulatory guidance from the perspective of BFS operations, and considers specific aspects of BFS operation which are not covered by existing published information. The PTC is intended as a guide for industry and is not meant to supplant or duplicate any existing regulatory guidance. A list of current regulatory guidance references is provided in the Appendix.

12 3. BFS PROCESS OUTLINE Blow-Fill-Seal technology is a pharmaceutical filling process in which containers are formed from a thermoplastic granulate, filled with product and then sealed in a continuous, integrated, automatic operation. Originally developed for use in other industries, BFS technology has been adapted for use in the manufacture of sterile pharmaceutical, medical device, biological, and veterinary products. The two most common types of BFS machines are the shuttling machine (with parison cut) and the rotary machine (closed parison) types. Both are considered in this document. In the process, bulk solution/suspension is delivered to the filling machine, through the filling system to the filling needles ( mandrels ). Polymer granules are extruded under pressure (up to 350 bar) as a hot (approx. 180 C) mouldable plastic tube ( parison ) or set of parisons. 3.1 SHUTTLE TYPE MACHINES A downward flow of sterile filtered air is passed through the parison (parison support air) to prevent collapse of the molten tube. The 2 halves of a mould close around the parison(s) to form the body of the container(s). Simultaneously, the newly formed container in the mould is cut free from the parison by a knife. The mould is transferred to the filling position. The filling mandrel is lowered into the plastic tube and the container is shaped either by vacuum or with sterile blowing air or other inert gas supplied by the mandrel. Subsequently, the container is filled with the required volume of the product. During the liquid fill, headspace gas is displaced from within the container, either through the mandrel or direct to room atmosphere, depending on the container configuration. The filling mandrel is then raised and the containers are sealed automatically by forming the still hot plastic above the main mould, by closing

3.1 Shuttle Type Machines 13 the upper section of the mould, (head/seal mould). The entire mould assembly then opens, releasing the filled container(s) that have been formed, filled and sealed. This complete cycle generally takes between 10 20 seconds depending on container design and volume of fill. Parison extrusion continues, as the mould returns to the first station, and the cycle repeats (Fig. 1). Extrusion Blowing Filling Sealing Demoulding Fig. 1 Schematic representation of the open parison Blow-Fill-Seal process.

14 3. BFS PROCESS OUTLINE 3.2 ROTARY FILLING MACHINES There are a number of significant differences between shuttling zone machines and rotary filling machines: Rather than 1 or 2 sets of moulds, there are typically 15 sets located on 2 rotating chains. The units are produced in 1 continuous ribbon. This means that there is no shuttling zone or knife cut required for machines of this type. As a result, particle generation is generally reduced and the units are not open to the environment at any point during the process (Fig. 2a and 2b). Fig. 2a Schematic representation of the closed parison Blow-Fill-Seal process.