Schedule of ccreditation United Kingdom ccreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ccredited to Laboratory locations: i54 Business Park Valiant Way Wolverhampton WV9 5GB Issue No: 016 Issue date: 12 pril 2018 Contact: Narinder Ramewal Tel: +44 (0)1902 627200 E-Mail: narinderramewal@eurofins.com Website: www.eurofins.com below s covered by the organisation and their relevant activities details ctivity code ddress i54 Business Park Valiant Way Wolverhampton WV9 5GB Local contact Narinder Ramewal Tel: +44 (0)1902 627200 Fax: +44 (0)1902 746183 Emial: narinderramewal@eurofins.com Testing: Water Chemistry Water Microbiology Support Functions: ll management activities ddress Prova Court 17 Doman Road Camberley Surrey GU15 3DF Local contact Ewelina O Reilly Tel: +44 (0)1276 686575 Fax: +44 (0)121 251 4040 Email: ewelinaoreilly@eurofins.com Testing: Water Chemistry Water Microbiology B ddress 6-8 Cochrane Square Brucefield Industrial Estate Livingston EH54 9DR Local contact Narinder Ramewal Tel: +44 (0)1506 534317 Fax: +44 (0)1506 534317 Email: narinderramewal@eurofins.com Testing: Water Microbiology C ssessment Manager: DF Page 1 of 7
Schedule of ccreditation United Kingdom ccreditation Service ccredited to Issue No: 016 Issue date: 12 pril 2018 DETIL OF CCREDITTION WTERS Microbiological Tests Documented In-house Methods Enumeration of: Ground and surface waters Drinking (excluding bottled waters at locations B and C), Process (tap and hot water systems), Recreational (man made) Coliforms, Total MW17 MPN using IDEXX Quanti- Tray Procedure The Microbiology of Drinking Water Part 4D (2009), Environment gency MW9 using Membrane Filtration (MLG) based on The Microbiology of Drinking Water Part 4 2009 Section B, B, C, B MW10 using Membrane Filtration (MLG) based on The Microbiology of Drinking Water Part 4 2009 Section B microtitre confirmation using growth characterisation in Idexx Colilert-18 medium and oxidase reaction B Escherichia coli MW17 MPN using IDEXX Quanti- Tray Procedure The Microbiology of Drinking Water Part 4D (2009), Environment gency, B, C Total aerobic colony count: 37 C, 30 C and 22 C MW3 based on The Microbiology of Drinking Water Part 7 2007, B, C Enterococci (Faecal streptococci) MW6 based on The Microbiology of Drinking Water Part 5 2010, B, C Sulphite-reducing Clostridia including Clostridium perfringens MW5 based on The Microbiology of Drinking Water Part 6 2010, B, C Pseudomonas species, presumptive MW4 using CFC gar at 25 C for 48h or 30 C for 48h, B, C Pseudomonas aeruginosa MW4 based on The Microbiology of Drinking Water Part 8 2010, B, C Pseudomonas aeruginosa MW18 using IDEXX Pseudalert, B, C ssessment Manager: DF Page 2 of 7
Schedule of ccreditation United Kingdom ccreditation Service ccredited to Issue No: 016 Issue date: 12 pril 2018 WTERS (cont d) Microbiological Tests (cont d) Documented In-house Methods Isolation and enumeration of: Legionella species and Legionella pneumophila serogroups 1 and 2-14 MW16 using filtration for clean waters, selective media and latex agglutination based on BS 6068 4-12 1988, B Legionella spp. and Legionella pneumophilia confirmation EUMM 3.60 using Bruker MLDI- TOF-MS in conjuction with MW16 for latex agglutination Drinking, Process (tap water not drinking) Detection and Quantification of Legionella pneumophila and Legionella spp. DN MW19 using membrane filtration, extraction and DN purification of sample followed by amplification of genomic sequences by Real-Time PCR using Bio-Rad quadien Kit and Bio-Rad CFX96 PCR system with C1000 Thermal Cycler Endoscope disinfector rinse waters (free from disinfectant agents) Total aerobic colony count at 30 C MW20 using membrane filtration, plating on to TS in duplicate, incubated for 5 days, B Chemical and Physical Tests Documented In-house Methods Land Leachate mmonia, Nitrite, Phosphorus, Chloride, Total Oxidised Nitrogen, Sulphate, Fluoride, Colour EIWC01 Method for Spectrophotometric Determination of mmonia, Nitrite, soluble Reactive Phosphorus, Chloride, Total Oxidised nitrogen, Sulphate, Fluoride and Colour using Discrete nalyser (quakem 250 and quakem 600) Processed water (hydroponic solution) ph, Conductivity, lkalinity EIWC02 Determination of ph, Conductivity and lkalinity using Metrohm 815 Sample Changer, 809 Titrando and 712 Conductometer ssessment Manager: DF Page 3 of 7
Schedule of ccreditation United Kingdom ccreditation Service ccredited to Issue No: 016 Issue date: 12 pril 2018 WTERS (cont d) Chemical and Physical Tests (cont d) Documented In-house Methods Turbidity EIWC03 Method for the Determination of Turbidity Using the HCH 2100 Surface water Free and total Chlorine EIWC04 analysis of Free and Total Chlorine Using HCH Powder Pillows, B Total Suspended Soilds Chemical Tests EIWC05 Determination of Total Suspended Solids Documented In-house Methods Determination of Total Dissolved Solids and Total Solids EIWC06 Detemination of Total Dissolved solids and Total Solids Land Leachate Chemical Oxygen Demand (COD) EIWC08 Determination of Chemical Oxygen Demand by the Dr Lange COD nalysis System using the LCK114 Extended Profile Land Leachates Total Metals as follows: luminium, Boron, Barium, Beryllium, Cadmium, Calcium, Chromium, Cobalt, Copper, Iron, Lead, Lithium, Magnesium, Molybdenum, Nickel, Phosphorus, Potassium, Sulphur, Silicon, Silver, Sodium, Strontium, Tin, Vanadium, Zinc EIWC09 Method for the Digeston of Raw and Treated Wastewater,, Raw Waters and Beers using the Environmental Express SC 154 Hotblock Digestion system ND EIWC10 using Inductively Coupled Plasma Optical Emission Spectrometric Determination of Total Metals Using ICP-OES ssessment Manager: DF Page 4 of 7
Schedule of ccreditation United Kingdom ccreditation Service ccredited to Issue No: 016 Issue date: 12 pril 2018 WTERS (cont d) Chemical Tests (cont d) Documented In-house Methods Surface water Dissolved Metals as follows luminium, Boron, Barium, Beryllium, Cadmium, Calcium, Chromium, Cobalt, Copper, Iron, Lead, Lithium, Magnesium, Molybdenum, Nickel, Phosphorus, Potassium, Sulphur, Silicon, Silver, Sodium, Strontium, Vanadium, Zinc EIWC09 Method for the Digeston of Raw and Treated Wastewater,, Raw Waters and Beers using the Environmental Express SC 154 Hotblock Digestion system ND EIWC11 Method for the Inductively coupled Plasma Optical emission Spectrometry (ICP-OES) Group Water Dissolved and Total Metals as follows luminium, ntimony, rsenic, Boron, Barium, Beryllium, Cadmium, Calcium, Chromium, Cobalt, Copper, Iron, Lead, Magnesium, Manganese, Molybdenum, Nickel, Potassium, Selenium, Sulphur, Silicon, Silver, Sodium, Strontium, Thallium, Titanium, Vanadium, Zinc EIWC12 using Inductively Coupled Plasma Mass Spectrometric (ICP- MS) Total Silver EIWC13 using Inductively Coupled Plasma Mass Spectrometric (ICP- MS) Process waters (hydroponic solutions) lkalinity (as bicarbonate) N/001 by titration Process waters (hydroponic solutions) mmonia Chloride Nitrate I/059 by discrete analyser Boron, Calcium, Copper, Iron, Magnesium, Manganese, Phosphorus, Potassium, Sodium, Sulphate, Zinc ICP/005 by ICP-OES ssessment Manager: DF Page 5 of 7
Schedule of ccreditation United Kingdom ccreditation Service ccredited to Issue No: 016 Issue date: 12 pril 2018 WTERS (cont d) Chemical Tests (cont d) Documented In-house Methods Raw and potable waters lkalinity (as carbonate or bicarbonate) N/002 by potentiometric determination mmonia Chloride Nitrate Orthophosphates I/059 by discrete analyser Calcium, Magnesium, Potassium, Sodium, Sulphur ICP/005 by Inductively Coupled Plasma Optical Emission Spectrophotometry (ICP-OES) Potable, processed, ground water and effluents luminium, ntimony, rsenic Barium, Beryllium, Boron, Cadmium, Chromium, Cobalt, Copper, Iron, Lead, Lithium, Manganese, Mercury, Molybdenum Nickel, Rubidium, Selenium, Strontium, Tin, Zinc N/036, sample extraction method) followed by ICPMS/009 using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) I/059 by discrete analyser Waste waters - leachates, untreated and treated domestic and industrial waste waters mmonia Chloride Nitrate Nitrite Orthophosphates I/059 by discrete analyser Solids (total) N/023 by Gravimetric determination Waste waters - leachates, untreated and treated domestic and industrial waste waters luminium, Boron, Cadmium, Calcium, Chromium, Copper, Iron, Lead, Magnesium, Manganese, Nickel, Phosphorus, Potassium, Sodium, Sulphur, Zinc ICP/003 by Inductively Coupled Plasma Optical Emission spectrophotometry (ICP-OES) Process waters, treated surface waters and treated ground waters Permanganate value (PV) EIWC07 nalysis of Permanganate Value by 4 hour digestion at 27 C using titrimetry ssessment Manager: DF Page 6 of 7
Schedule of ccreditation United Kingdom ccreditation Service ccredited to Issue No: 016 Issue date: 12 pril 2018 WTERS Physical Tests Documented In-house Methods Raw and potable, waste waters leachates, nutrient solutions Conductivity ph N/011 using conductivity N/018 using ph electrode END ssessment Manager: DF Page 7 of 7