C-Chip DHC-N01 Disposable Hemocytometer

Similar documents
All-In-One for cell research

INTRODUCTION: TECHNICAL DESIGN:

ADAM. A New Standard of INSTRUCTION MANUAL NESMU-AMC-001E (V.3.0)

EVE. Automatic cell counter. Crazy + Tangible play, 2K13.

Lab: Blood Smear and RBC Count

5- Monitoring algal populations

ADAM. A New Standard of Automatic Cell Counter INSTRUCTION MANUAL NESMU-ASC-001E (V.2.5)

Please read all the information in booklet before using the unit

Tube Formation Assays in µ-slide Angiogenesis. 1. General Information. Application Note 19

Bioneer Corporation 8-11,Munpyeongseo-ro, Daedeok-gu, Daejeon 34302, Republic of Korea Tel: Fax:

E. coli Phagocytosis Assay Kit

Clinical Sample Processing Guide. Version 1.1

AccuPrep Plant Genomic DNA Extraction Kit

mdi Medi-R Total RNA PLUS Miniprep Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies

Reagent Kit Selection Guide

AccuPrep Genomic DNA Extraction Kit

Exercise 13 DETERMINATION OF MICROBIAL NUMBERS

Tube Formation Assays in µ-slide Angiogenesis

CloneMedia-CHO Semi-solid media for the growth of CHO-S Colonies

Genomic DNA Extraction Mini Kit (Blood and Urine)

Page 2 of 16. Introduction. Contents

Introduction. Principle

EasyPrep TM Adeno-Associated. Virus Purification Mini Kit Manual. (All Serotype) Catalog#: AAV11-00, AAV11-01, AAV11-02

ISOLATION AND BANKING OF PBMCS FROM HUMAN WHOLE BLOOD

Mammalian Chromatin Extraction Kit

Bioneer Corporation 8-11,Munpyeongseo-ro, Daedeok-gu, Daejeon 34302, Republic of Korea Tel: Fax:

NucleoCounter NC-3000

Phagocytosis Assay Kit (IgG PE)

Counting Yeast, Human Platelet, and Algae

MagniSort Mouse CD3 Positive Selection Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

Introduction to AB Medical

RayBio Genomic DNA Magnetic Beads Kit

DNA Purification Magnetic Beads

AccuPrep Stool DNA Extraction Kit. Cat. No.: K-3036

Using Complete Blood Cell Counts to Diagnose Disease

Reagents provided. R075 RBC Lysis Buffer (10X RBL) 5 ml 25 ml 80 ml 160 ml

Immunofluorescence Staining Protocol for 3 Well Chamber, removable

TOP General Genomic. DNA Purification Kit (mini-prep) For laboratory use only. Cat. No.: TGk1003 (50 prep) TGk (25 prep)

Collecting Blood and Isolating PBMCs

Cells and Tissue DNA Isolation Kit (Magnetic Bead System) 50 Preps Product # 59100

Downloaded from and current as of 02/01/2008

Protocol for Small-Scale Microcarrier Culture

MagniSort Human NK cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

MagniSort Mouse B cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

Tube formation assays in µ-slide Angiogenesis

STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 101 MOD: 2 nd Issue Page: 1 of 6 Procedure Type: General Laboratory Procedure

CloneMedia-CHOK1SV Semi-solid media for the growth of CHOK1SV colonies

Register your instrument! MagSep Blood gdna Kit. Instructions for use

Cells and Tissue DNA Isolation 96-Well Kit (Magnetic Bead System) Product # 62500

Blood DNA Extraction Kit

πcode TM MicroDisc, Pre-activated (10-plex Sampler Kit) User Manual

NETosis Assay Kit. Item No Customer Service Technical Support

mag mini kit Description Kit uses

Standard Operating Procedure

Total RNA Purification Kit. Cat. #.: TR01 / TR Size : 50 / 150 Reactions Store at RT For research use only

Rat GLO ELISA Kit. For the quantitative in vitro determination of Rat Glyoxalase concentrations in

Bovine IgG-Ab ELISA Kit

Wolf Laboratories Limited

Human CTRP5 ELISA Kit

Protocol. Culture for human ips cells under the feeder-free condition

Monkey hs-tnt ELISA Kit

Guinea pig 25-OH-VD ELISA Kit

MagniSort Mouse T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

CFSE Cell Division Assay Kit

Canine Cortisol(COR)ELISA Kit

Lab Module 7: Cell Adhesion

Preparation of Mouse Bone Marrow Stromal Cells

USER GUIDE. HiYield TM Total RNA Extraction Kit

Campylobacter Jejuni Real Time PCR Kit

Using the C 1 Single-Cell Auto Prep System to Capture Cells from Cell Culture and Perform Preamplification Using TaqMan Assays.

Total RNA Miniprep Purification Kit. Cat.# :TR01/TR Size : 50/150 Reactions Store at RT

SurePAGE, Bis-Tris, 10 cm 8cm gels Version: 08/28/2017

Human Splenocyte Cell Care Manual

Neutrophil/Monocyte Respiratory Burst Assay Kit

EasyPrep TM Adeno-associated Virus Purification Mini Kit Manual

Xanthine Oxidase Assay Kit

Protease Activity Assay Kit

Basic&Laboratory& Materials&Science&and&Engineering& Biocompatible&Tests&of& Materials&

AmoyDx FFPE RNA Kit. (Spin Column) For purification of total RNA from formalin-fixed, paraffin-embedded tissue sections. Instruction for Use

For the preparation of purified mononuclear immune cells directly from whole blood PACKAGE INSERT. For In Vitro Diagnostic Use PI-TS-IVD-UK-V3

Neural Stem Cells (ipsc from Blood Cells; Male)

BQ Revision : 1 ( )

VitroGel ready-to-use tunable hydrogel for 3D cell culture and beyond

ab Histone Extraction Kit Rapid / Ultra-pure

Adenovirus Titration Kit

Revised 27 Aug rm (Vers. 4.1)

Hydroxyproline ELISA Kit

Human whole blood RNA Purification Kit

Plus Blood Genomic DNA Purification Kit

RayBio Human, Mouse and Rat Phospho-MET (Tyr1234/1235) and Total MET ELISA Kit

For the preparation of purified mononuclear immune cells directly from whole blood PACKAGE INSERT. For In Vitro Diagnostic Use PI-TS-IVD-UK-V4

Instruction Manual. Comet Assay Tanks Catalogue Numbers BCOM10 BCOM20 BCOM40 BCOM80

RayBio Human, Mouse and Rat Phospho-STAT3 (Tyr705) ELISA Kit

TECHNICAL BULLETIN NUCLEI EZ PREP NUCLEI ISOLATION KIT. Product Number NUC-101 Store at 2-8 C

Multidrug Resistance Assay Kit (Calcein AM)

EPIGENTEK. ChromaFlash Chromatin Extraction Kit. Base Catalog # P-2001 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE KIT CONTENTS

USER GUIDE. Prelude. Direct Lysis Module PART NOS , 1400-A01

E.Z.N.A. FFPE RNA Kit. R preps R preps R preps

Ver 1.0. Stool DNA mini kit. exgene TM DNA PURIFICATION HANDBOOK

Transcription:

INSTRUCTIONS www.incyto.com C-Chip DHC-N01 Disposable Hemocytometer System Neubauer Improved Ordering Information Worldwide Tel : +82-2-3787-196, 5 Fax : +82-2-537-269 E-Mail : sales@incyto.com Domestic(Korea) Tel : +82-31-20-0330 Fax : +82-31-20-0312 E-Mail : sales@incyto.com

Trouble shooting In case of poor visible results. Carefully load samples into the C-Chip to make sure to prevent the introduction of air bubbles. Observe after remove the dust from samples. Adjust focus of the microscope. All the materials in this manual are protected by Korean and international copyright laws. This manual may not be reproduced, translated, published or distributed by any means without the permission of the copyright owner. C-Chip DHC-N01, Instruction Manual Website: www.incyto.com E-mail: sales@incyto.com Developed by Digital Bio Technology Co., Ltd. #511, SKC Central Research Institute, 911, Jeongja-1dong, Jangan-gu, Suwon, Gyeonggi, 0-301, Korea. Tel: +82-31-20-0330 Fax: +82-31-20-0312 E-Mail: sales@incyto.com Manufactured by SKC Co., Ltd. Kyobo Tower, 1303-22, Seocho-dong, Seocho-gu, Seoul, 137-070, Korea Tel: +82-2-3787-196, 5 Fax: +82-2-537-269 E-Mail: sales@incyto.com The information in this manual is described as correctly as possible, but it may be changed without prior consent or notification. Copyright 200, by INCYTO. Documentation : DHC-N01(Rev A.01.50-02/06) All rights reserved. Published in Korea. Visit our website at www.incyto.com 6

Contents C Erythrocyte counting (1:200 dilution) Unpacking..... 1 Features 1 Safety Precautions. 1 Safety Symbols... 2 Introduction.. 3 Counting with C-Chip. A. General Methods... B. Mammalian cell counting C. Erythrocyte counting. 5 D. Leukocyte counting 5 Trouble shooting. 6 1 Dilute blood using accepted laboratory methods. 2 Load 10 µl of diluted sample into the sample injection area in Fig. 2. 3 Count the erythrocytes in the 5 small squares (four small corner squares and one small middle square) of the large center square. RBCs per ml = cells in 5 smallsquares 5 200(dilution factor) 10 (volume factor) D Leukocyte counting (1:20 dilution) 1 Dilute blood using accepted laboratory methods. 2 Load 10 µl of diluted sample into the sample injection area in Fig. 2. 3 Count the leukocytes in the large corner squares. WBCs per ml = cellsin corner squares 20(dilution factor) 10 (volumefactor) 5

Counting with C-Chip A General Methods 1 Mix the samples well. 2 Load 10 µl of sample into the sample injection area in Fig. 2, so that it fills the chamber by capillary action. 3 Count the cells under microscope. Cells per ml = Average count per square dilution factor volume factor B Mammalian cell counting 1 Treat the cell samples with trypsin-edta. 2 Carefully remove the supernatant with a pipette tip without disturbing the pellet. 3 Add an appropriate volume of growth media or PBS to dilute to a final concentration of 5ⅹ10 3 cells/ml to 5ⅹ10 6 cells per ml. Thoroughly resuspend the cell pellet with a pipette. 5 Check visually if there are any cell clumps or agglomerates. 6 Load 10 µl of sample into the sample injection area in Fig. 2. 7 Count the cells in 5 large squares. Cells per ml = cells in 5 large squares dilution factor 10 (volume factor) 5 Unpacking When you receive the C-Chip (DHC-N01) for the first time, you will find the following components in your package. Disposable hemocytometer chip Instruction manual Features Precise fixed depth counting chamber with superior accuracy and reproducibility. No need to place cover glass on slide. Reduced the risk of exposure to potentially infectious material. Increased productivity by eliminating cleaning and work interruptions. Light and unbreakable, compared with glass. Safety Precautions For analyzing hazardous or potential infectious materials: Take necessary precautions Handle with care Dispose in an appropriate way Long exposure to solvents will cause the slide to warp. Xylene and toluene based mounting media should be avoided. Glycerol, gelatin, and other aqueous based media are recommended. 1

Safety Symbols Introduction The safety symbols on the C-Chip (DHC-N01) are to inform you of potential danger or particular caution. Before use, please read and consult symbols and their meanings. The C-Chip (DHC-N01) is a disposable plastic hemocytometer used for manual cell counting. It consists of surface-patterned two enclosed chambers with two ports for sample injection (Fig. 2). Batch Code (Lot Number) Use By The DHC-N01 grid pattern is exactly same as the Neubauer Improved. It consists of 9 large squares, each measuring 1ⅹ1 mm, and the depth of the chamber is 0.1 mm. Each square has a total volume of 0.1 mm 3 or 10 - cm 3 (Fig. 1). Date of Manufacture A Manufacturer The central square is divided into 25 small squares with triple lines and four corner squares are divided into 16 small squares. Do not Reuse Danger i See Instruction for Use Figure 1. Grid pattern Detection area NOTE The C-Chip (DHC-N01) is for single use only. Do not reuse. It should be used immediately after unsealing. The warranty on the C-Chip included in the conditions of supply is valid for 15 months from the date of manufacturing. Sample injection area Figure 2. DHC-N01 2 3