New European Rules governing medical devices vigilance and combination products. Lincoln Tsang May 2008

Similar documents
Are Pharmaco- and Medical Device Vigilance the same?

PROPOSED DOCUMENT. Global Harmonization Task Force. Title: Reportable Events During Pre-Market Clinical Investigations

Guide to field safety corrective actions for medical devices and in-vitro diagnostic medical devices

Regulatory Affairs in Medical Technology

Essential Requirements Straumann Custom-made Dental Restorative Devices According to 93/42/EEC annex I as amended by 2007/47/EC

Changes to the Medical Devices Directive and affect on Manufacturers

GUIDELINES ON MEDICAL DEVICES

GUIDELINES ON MEDICAL DEVICES

Regulatory Framework for Medical Device

Post market Surveillance ISO EU Medical Device Regulation

Bridging gaps: medical device directive vs regulation. Geert Corstens 1 November 2018

Impact of the IVD Regulations. Barbara Fallowfield Managing Director

Guide for Class I Manufacturers on Compliance with European Communities (Medical Devices) Regulations, 1994

Guidelines for conformity assessment of In Vitro Fertilisation (IVF) and Assisted Reproduction Technologies (ART) products

Guide for Manufacturers and Sponsors on Clinical Investigations Carried Out in Ireland

Update on Regulatory Environment- Europe Experience with 2007/47/EC M5 & Discussions on Possible Recast of EU Medical Device Regulations

Post Market Surveillance (including PMCF): common non compliances

The challenges of software medical device regulation.

IVDR Breakout. Copyright 2017 BSI. All rights reserved.

GUIDELINES ON MEDICAL DEVICES CLINICAL EVALUATION: A GUIDE FOR MANUFACTURERS AND NOTIFIED BODIES

GUIDANCE NOTES FOR MANUFACTURERS OF CLASS I MEDICAL DEVICES

Update on the IVDR. Sue Spencer

Introduction to the new regulatory framework for medical devices and in vitro diagnostic medical devices

MEDICAL DEVICES REGULATORY ISSUES: RESPONSIBILITIES OF A CLINICIAN

Impact Assessment of Revision of the Regulatory Framework for Medical Device Directive in EU

EU MDR Deep Dive: GSPRs, Technical Docs, PMS. 19 JUNE 2018 ASQ RAPS MASSMEDIC Waltham Woods

GUIDANCE NOTE FOR MANUFACTURERS OF CUSTOM-MADE MEDICAL DEVICES

New Regulation (Draft) for Medical Devices. September 11, 2013 Dr. med. Christian Schübel

Post Market Surveillance

Guide to the in-vitro diagnostic medical devices legislation

Regulatory and ethical requirements in medical devices studies. Italy

The New EU Medical Device Regulation (MDR) An Active Device Lifecycle Approach Implementation and Remediation Activities

Experience with Directive 93/42/EEC (MDD)

The importance of implementing a continuous cycle of improvement for medical devices. Roles for various stakeholders

GUIDELINES ON MEDICAL DEVICES GUIDE FOR COMPETENT AUTHORITIES IN MAKING AN ASSESSMENT OF CLINICAL INVESTIGATION NOTIFICATION

Due diligence in the European medical devices industry

MEDICAL DEVICES: Guidance document

Technical documentation. Capita Selecta proposed MDR

IVD Regulation 2017/746

Recast Medical Device directives Impacts on materiovigilance

WHO post-market surveillance of in vitro diagnostics

APPLICATION FORM. Application for a Recognised Research Ethics Committee (REC) Opinion on a Clinical Trial on a Medicinal Product for Human Use.

Manufacturers. Factsheet for. of Medical Devices. Medical Devices Regulation (MDR) background. Act now to be ready on time!

A Review on European Union New Medical Device Regulations- 2017

Clinical Data Evaluation Lessons Learned

GS1 Ireland Healthcare User Group (HUG) Information Day

Technical Documentation

Medical Device Regulatory Framework 9 SEPTEMBER 2015 FUNDISA CONFERENCE JANE ROGERS

Manufacturers. Factsheet for. of Medical Devices. Medical Devices Regulation (MDR) background. Act now to be ready on time!

Impact of the MD/IVD Regulations on Quality Management Systems

Guide for Ethics Committees on Clinical Investigation of Medical Devices

New EU Regulation on medical devices

Ready or Not: The New Medical Device Regulations Are Here!

Medical Devices Regulation (MDR) Readiness Review

Medical Device Regulation Overview

Meeting the Clinical Evaluation Requirements for CE Marking: Challenges for Innovative Start-ups Sarah Sorrel, MedPass International SAS

Technical documentation in the new MDR. Gabriele Catignoli, Andreas Purde

Recommendations on Medical Device and IVD Field Safety Corrective Actions and Recalls using Unique Device Identifiers & GS1 Standards

Incorporating FDA Regulatory Thinking into Plans for Medical Devices

Disclosures. Laboratory Stakeholders. IVD vs. LDT. FDA Regulation of Laboratory Developed Tests 10/2/2015. FDA Regulation of LDTs

VIGILANZA E SORVEGLIANZA POST- COMMERCIALIZZAZIONE

MEDICINES CONTROL COUNCIL

BSI Audits for MDR Certification

PHYSICO-CHEMICAL, BIOLOGICAL OR MICROBIOLOGICAL TESTS OF MEDICINAL PRODUCTS

MedDev Rev 4 Medical Devices Regulation. Clinical Evidence Requirements Key Changes and Clarifications. Alan Eller 21 March 2017

IVD Regulation Update

Safety monitoring and reporting in clinical trials involving therapeutic goods

Classification of MDs under the European MDR. Joachim Makowski. Joachim Makowski, MED-RAS GmbH, a partner to confinis ag

CAMD Implementation Taskforce

Guidance on legislation. Clinical investigations of medical devices guidance for investigators

What you need to know about the new European IVD Regulation

COCIR SUSTAINABLE COMPETENCE IN ADVANCING HEALTHCARE

Effects of the European MDR on the Quality Management System. Karl-Heinz Spohn

SOFTWARE APPS AS MEDICAL DEVICES. The Regulatory Landscape 2015 WHITE PAPER WHITE PAPER PRODUCED BY MAETRICS

COMMISSION RECOMMENDATION. of XXX. on the audits and assessments performed by notified bodies in the field of medical devices

Update on Recast of IVD Directive

The upcoming EU MDR. Gert Bos. - key changes overview. Executive director & Partner. ..the practical approach

10728/4/16 REV 4 ADD 1 psc 1 DRI

General Safety and Performance Requirements Regulation (EU) 2017/ 745 on medical devices (MDR) - Annex I I. GENERAL REQUIREMENTS

An introductory guide to the medical device regulation (MDR) and the in vitro diagnostic medical device regulation (IVDR)

New EU Medical Device Regulations.are you ready? Angela Stokes Senior Director Regulatory Affairs March 2017

TERMS AND DEFINITIONS

January Summary

Self-Care Medical Devices Framework. Dr. Simone Breitkopf Head HEOR, Governmental and Public Affairs

Developing a Companion Diagnostics in parallel to a medicinal product Legal and Regulatory requirements in Europe and in the US

GUIDELINES ON MEDICAL DEVICES

The Institutional Review Board (IRB) Manual

Changes in EU Clinical Data Requirements and Expectations

UNCONTROLLED DOCUMENT WHEN PRINTED

MEDICAL DEVICE CLINICAL INVESTIGATIONS AND ISO 14155

IVD Regulation What you need to know. Erica Conway 5 th May 2017

WORKING DRAFT DOCUMENT

State Institute for Control of Drugs-/ Státní ústav pro control léčiv (SÚKL) Regulatory and ethics bodies involved in approval process

Standard Operating Procedure. Safety Reporting for NuTH Sponsored, Medical Device Trials. SOP effective: 03 January 2018 Review date: 03 January 2020

EC REVIEW OF THE ATMP REGULATION CELL THERAPY CATAPULT RESPONSES

Device research sponsors, whether companies or investigators, are held responsible for meeting the same regulations.

3.1. Overall Principal Investigator (PI), who holds the IDE and/or is the Sponsor

Korean Medical Devices Regulations

The New EU RoHS Directive: Key Topics Under Review

Transcription:

New European Rules governing medical devices vigilance and combination products Lincoln Tsang May 2008

Topics Review of rules governing medical devices sector Changes made in the new law New framework governing novel combination products 5/27/2008 2

European regulatory landscape Directives on devices adopted in 1990, 1993 and 1998 constitute the basic regulatory framework to harmonise practices in Member States Placing on the market is linked to the need to undertake conformity assessment with essential requirements Risk assessment Risk management Risk/benefit analysis Standards 5/27/2008 3

Reviews Medical Devices Experts Group (June 2002) Functioning of the Medical Devices Directive Commission Communication to Council of Ministers and European Parliament (May 2003) Enhancing the implementation of the New Approach Directives Commission Communication to Council of Ministers and European Parliament (July 2003) Medical devices 5/27/2008 4

Conclusion of Sector-specific Reviews The basic framework remains appropriate Room for improvement in a number of areas, including Conformity assessment Proper implementation of provisions on clinical data and quality assurance Post-market Surveillance Vigilance Co-operation between Member States International dimension 5/27/2008 5

What happened during the legislative process? EP negotiated 141 amendments definition of single use proposal from Commission on reprocessing of devices specific labelling requiring for SUD and devices containing DEHP Council negotiated 90 amendments 17 out of 23 articles are changed 9 out of 12 annexes of MDD modified Mixture of cosmetic changes and substantial major changes Alignment of AMIDD with MDD 5/27/2008 6

Major changes to the regulatory framework Refinement made: clinical evaluation classification and the corresponding conformity assessment uniform application of rules and demarcation reclassification issues principle of design for patient safety 5/27/2008 7

Why clinical trials and monitoring? Failure ex vivo to mimic clinical evaluation Proof of concept Modifications New purpose User issues Efficacy Safety for humans Pharmacoeconomic considerations 5/27/2008 8

An example- treatment of abdominal aortic aneurysms Design Stress testing Fatigue testing X Fractures in vivo X Endoleaks 5/27/2008 9

Clinical evaluation In principle clinical evaluation is necessary for every device In principle for Class III device and implantable devices a clinical investigation has to be performed Documentation of clinical evaluation now part of the technical documentation Notified bodies are required to assess clinical evaluation as part of conformity assessments (subject to classification of the device) Principles of clinical evaluation clarified 5/27/2008 10

Clinical data in new law (amendment made to Annex X) Information about safety and/or performance generated from use of device Clinical investigations Clinical investigations or other studies reported in literature or similar device (where equivalence to the device in question can be demonstrated) Published and/or unpublished reports on other clinical experience of either the device or similar device 5/27/2008 11

Continuous monitoring Clinical evaluation must be kept up to date Implementation of post-market clinical follow up (PMCF) as part of PMS unless justification for absence Exchange of information as regards clinical investigations between CAs information on approval or non-approvals of clinical studies information on termination of clinical trials information on adverse events 5/27/2008 12

Essential requirements Inclusion of design for patient safety Consideration of ergonomic features mental, physical and health conditions of patients and users (home use devices for disabled and elderly patients) Electronic labelling possible in the future (requires implementation) Specific labelling requirements for SUD (risks on reuse) 5/27/2008 13

Read across to Machinery Directive Machinery Directive excluded medical devices Where the relevant hazard exists, devices which are also machinery must also meet the essential health and safety requirements set out in Annex I of [Machinery Directive] to the extent that those essential health and safety requirements are more specific than MDD lex specialis applies if Machinery Directive is more specific (moving parts, assembling of devices at point of care) 5/27/2008 14

Special labelling requirements Devices intended to administer and/or remove medicines, body fluids or other substances to or from the body or devices intended for transport or storage of such body fluids or substances contain Phthalates Devices including treatment of children or pregnant or nursing women, justification for use substances which are classified as carcinogenic, mutagenic or toxic to reproduction in technical documentation and instructions for use residual risks based upon precautionary principle EP wanted to place prohibition of all dangerous substances 5/27/2008 15

Device Vigilance Most significant Changes made in amending Directive basic framework not changed collect, record, report Parallel changes made to MEDDEV 2.12-1 (Device Vigilance) 2.5 years consultation with CAs, Commission, industry and other interested parties agreed position of best practice in interpretation definitions process GHTF 5/27/2008 16

Reporting timescales Serious public health threat immediately but not later than 2 calendar days after awareness by the manufacturer Death or unanticipated serious deterioration in state of health immediately after the manufacturer established a link between the device and the event but not later than 10 elapsed calendar days following the date of awareness of the event Immediately means without delay that could not be justified 5/27/2008 17

Definitions Serious deterioration in state of health (expanded) life threatening illness or deterioration in state of health permanent impairment of a body function or permanent damage to a body structure a condition required medical or surgical intervention to prevent any indirect harm as a consequence of an incorrect diagnostic or IVD test results when used within IFU foetal distress, foetal death or any congenital abnormality or birth defects Serious public health threat any event type resulting in imminent risk of death, serious injury, or serious illness that may require prompt remedial action 5/27/2008 18

Field safety corrective action Replaced definition for recall action taken by manufacturer to reduce a risk of death or serious deterioration in the state of health associated with the use of a medical device already on the market action notified via a field safety notice In assessing need for FSCA, use methodology described in harmonised standard EN ISO 14971 last edition 5/27/2008 19

FSCA Return of device to supplier Device modification Device exchange Device destruction Retrofit by purchaser of manufacturer s modification or design change Advice given by manufacturer regarding use of the device 5/27/2008 20

Exemption rules Previous exemption rules 1-6 replaced by conditions where under the vigilance system a report is usually not required. Summary reporting might be allowed for incidents described in FSNs and for common and well documented incidents (cfr old exemption rules 7 & 8) 5/27/2008 21

Enforcement National competence effective dissuasive proportionate Co-ordination and centralisation of information exchange May be based upon consumer protection and/or general product safety regulation 5/27/2008 22

Challenges ahead: ancillary component to a device Novel drug/device combination products EMEA guidance on quality, safety and effectiveness of medicinal substance Advanced therapy medicinal products gene therapy cell therapy tissue engineered specific risk management guidance 5/27/2008 23