TaqMan Sample-to-SNP Kit

Similar documents
Multiplex RT for TaqMan Array Human MicroRNA Panel

TaqMan Protein Assays

TaqMan Protein Assays Probe Development

TaqMan GTXpress Master Mix. Protocol

Ion AmpliSeq Library Kit 2.0

Protocol for Creating Custom RT and Preamplification Pools using TaqMan MicroRNA Assays

Applied Biosystems 7900HT Fast Real-Time PCR System. Performing Fast Gene Quantitation with 384-Well Plates DRAFT

Volume of Each Kit Reagent (ml) XTerminator Solution. 2-mL mL 1, mL 2,

PrepSEQ Nucleic Acid Extraction Kit

TaqMan PreAmp Master Mix Kit. Protocol

Arcturus CapSure LCM MicroCaps

Perform an HRM Methylation Study

Phosphate buffered saline (PBS) for washing the cells TE buffer (nuclease-free) ph 7.5 for resuspending the SingleShot RNA control template

Protocol. Path-ID Multiplex One-Step RT-PCR Kit Protocol TaqMan probe-based multiplex one-step real-time RT-PCR detection of RNA targets

Phosphate buffered saline (PBS) for washing the cells TE buffer (nuclease-free) ph 7.5 for resuspending the SingleShot RNA control template

Applied Biosystems TaqMan Array Microfluidic Cards

PrepFiler Express and PrepFiler Express BTA Forensic DNA Extraction Kits

BigDye Direct Cycle Sequencing Kit

Direct amplification of FTA and swab samples using the Investigator Argus X-12 QS Kit

Prepare a Barcoded Fragment Library with the SOLiD Fragment Library Barcoding Kit 1 96

HelixAmp TM Direct RT-PCR Kit

Reliable extraction of DNA from Whatman FTA cards

E.Z.N.A. Plant Direct PCR Kit

For in vitro Veterinary Diagnostics only. Kylt Chlamydiaceae Screening. Real-Time PCR Detection.

For in vitro Veterinary Diagnostics only. Detection Reagents specific for. Chlamydia psittaci Real-Time PCR.

A Recommended Procedure for Real-Time Quantitative TaqMan PCR for Roundup Ready Canola RT73 Monsanto Biotechnology Regulatory Sciences

3 r. ProbeSure Genotyping Master Mix User Guide. Cbioscience. Page 1 ProbeSure User Guide v1.4

For in vitro Veterinary Diagnostics only. Kylt Brachyspira spp. Real-Time PCR Detection.

PROTOCOL. TaqMan OpenArray microrna Panel Using Megaplex Primer Pools

Clostridium difficile Toxin Genes A and B. Real-Time PCR Detection Kit for detection and differentiation of.

HighPrep Blood & Tissue DNA Kit

DIRECTION FOR USE. Art. No / /25 reactions in vitro Diagnosticum for birds

hpsc Genetic Analysis Kit

For in vitro Veterinary Diagnostics only. Kylt MHRS Triplex. Real-Time PCR Detection.

For in vitro Veterinary Diagnostics only. Kylt MHRS. Real-Time PCR Detection kit for Mycoplasma hyorhinis and hyosynoviae.

GenScript TissueDirect TM Multiplex PCR System

RapidFinder Quant Multi-Meat Set

resdnaseq Quantitative DNA Kits

High Resolution Melting Protocol

For in vitro Veterinary Diagnostics only. Real-Time RT-PCR Detection Kit for beta-actin.

For in vitro Veterinary Diagnostics only. Real-Time RT-PCR Detection Kit for Avian Hepatitis E Virus

Applied Biosystems Real-Time PCR Rapid Assay Development Guidelines

TaqMan OpenArray MicroRNA Panels

PrepSEQ Sample Preparation Kits for Mycoplasma, MMV, and Vesivirus

DNA Extraction and Real-Time PCR Detection Kit for Mycoplasma gallisepticum live vaccine strain ts-11.

Using the C 1 Single-Cell Auto Prep System to Capture Cells from Cell Culture and Perform Preamplification Using TaqMan Assays.

GeneAmp Fast PCR Master Mix (2 )

For in vitro Veterinary Diagnostics only. Real-Time RT-PCR Detection Kit for Reticuloendotheliosis Virus

E.Z.N.A. MicroElute Genomic DNA Kit. D preps D preps D preps

For in vitro Veterinary Diagnostics only. Kylt Avian Nephritis Virus. Real-Time RT-PCR Detection.

For in vitro Veterinary Diagnostics only. Kylt Chicken Astrovirus. Real-Time RT-PCR Detection.

PlantDirect TM Multiplex PCR System

Real-Time PCR Detection Reagents for Detection of Marek Disease Virus and differentiation between field strains and Rispens vaccine CVI988 strain

For in vitro Veterinary Diagnostics only. DNA Extraction and PCR Detection Kit for Pasteurella multocida.

Cells-to-CpG Bisulfite Conversion Kit (2x96) Protocol

For in vitro Veterinary Diagnostics only. Kylt Influenza A - H9. Real-Time RT-PCR Detection.

ncounter Elements TagSets General Purpose Reagents PACKAGE INSERT Molecules That Count NanoString Technologies, Inc.

Georgia Bureau of Investigation - Division of Forensic Sciences DNA Procedures Manual DNA QUANTIFICATION USING QUANTIFILER HUMAN / Y HUMAN MALE KIT

For in vitro Veterinary Diagnostics only. Kylt Avian Hepatitis E. Real-Time RT-PCR Detection.

Fragment Library Preparation Using the AB Library Builder System

Fragment Library Preparation

For in vitro Veterinary Diagnostics only. Real-Time PCR Detection Kit for detection of Histomonas meleagridis.

TaqMan SNP Genotyping Protocol

3C bioscience. ProbeSure Genotyping Master Mix User Guide. P a g e 1 ProbeSure User Guide v1.0

Eureka Genotyping Assay

Applied Biosystems 7500 Fast Real-Time PCR System

QIAGEN Supplementary Protocol

For in vitro Veterinary Diagnostics only. Real-Time RT-PCR Detection Kit for Avian Nephritis Virus

Protocol for DNA and RNA Isolation from the Same FFPE Sample

For in vitro Veterinary Diagnostics only. Kylt E. coli F18, F41, Stx2e. Real-Time PCR Detection.

Eluted DNA is high quality and inhibitor-free making it ideal for PCR and genotyping.

ProNex DNA QC Assay Calibration Kit, 7500

Compatible with commonly used anticoagulants (i.e., EDTA, heparin, citrate).

MagMAX FFPE RNA Isolation

myt KRAS qpcr primers for detection of seven human KRAS codon 12/13 mutations:

TaqMan GMO Maize Quantification Kit

TaqMan Environmental Master Mix 2.0 Real-time PCR Master Mix for inhibited samples. Protocol

Characterization of the Pipette Wash Station for SNP Genotyping and Presence/Absence Testing on the Nexar System

Idaho Technology Inc. Kit No. HRLS-ASY Reactions

Copy Number Analysis Using Biomark HD with the IFC and TaqMan CNV Assays

RapidFinder TM Goat ID Kit

High Capacity RNA-to-cDNA TM Master Mix. Protocol

MagMAX DNA Multi-Sample Ultra Kit

QuickExtract RNA Extraction Kit

For in vitro Veterinary Diagnostics only. PCR Detection Kit for Fowl Adenovirus.

E.Z.N.A. Forensic DNA Kit. D preps D preps D preps

TECHNICAL BULLETIN. SYBR Green Extract-N-Amp Tissue PCR Kit Catalog Numbers XNATG and XNATRG

High specificity and sensitivity for fungal DNA allows reliable quantification in a background of nonfungal. Contents

Spin Micro DNA Extraction Kit

Salmonella Enteritidis vaccine strain SM24/Rif12/Ssq

Accurately and reproducibly quantify as little as 20 fg of bacterial DNA using real-time PCR.

E.Z.N.A. Microorganism Direct PCR Kit

Extended Protocol for RNA Isolation from FFPE Sample

Cells-to-C T 1-Step TaqMan Kit

For in vitro Veterinary Diagnostics only. PCR Detection Kit for Salmonella Gallinarum, Pullorum (separate detection) & DIVA 9R.

Table of Contents. I. Kit Components...2. Storage...2. Principle...2. IV. Precautions for operation...3. V. Protocol : reverse transcription...

RealLine Food Kit Turkey Detect

CENTER FOR CELL & GENE THERAPY VECTOR DEVELOPMENT LABORATORY, 10 TH FLOOR, ALKEK BUILDING ONE BAYLOR PLAZA, HOUSTON, TEXAS 77030

KAPA PROBE FAST qpcr Master Mix (2X) Kit

Transcription:

Quick Reference Card TaqMan Sample-to-SNP Kit Note: For safety and biohazard guidelines, refer to the Safety appendix in the Applied Biosystems TaqMan Sample-to-SNP Kit Protocol (PN 4402136). For all chemicals in bold red type, read the MSDS and follow the handling instructions. Wear appropriate protective eyewear, clothing, and gloves. Prepare the samples 1 2 3 Lyse the samples a. Obtain the samples for lysis according to Table 1 on page 2. b. Thoroughly mix the Lysis Solution. c. Add one volume of Lysis Solution to each 1.5-mL microcentrifuge tube or well of the plate containing the sample. See Table 1 on page 2 for volumes based on sample type and sample quantity. d. Pipette up and down to mix the Lysis Solution and the sample in each tube or plate well. e. Cap the tubes or seal the plate with an adhesive cover, then centrifuge the tubes or plate briefly. Incubate the samples Incubate the samples according to sample type as shown in Table 1 on page 2. For samples incubated at 95 C, cool at room temperature for 30 seconds before stabilizing the DNA (step 3). Stabilize the DNA a. Thoroughly mix the DNA Stabilizing Solution. b. Open the tube or uncover the plate. c. Add one volume of DNA Stabilizing Solution to each tube or well of the plate containing sample. See Table 1 on page 2 for volumes based on sample type. d. Pipette up and down to mix the solution and the sample in each tube or plate well. e. Cap the tubes or seal the plate with an adhesive cover, then centrifuge the tubes or plate briefly. 4 5 (Optional) Store the sample lysates Preamplify the samples or perform fast genotyping You can store the sample lysate at 4 C. For longer storage, you can store the sample lysate at 20 C. Before use, mix the sample lysate. Note: If the amount of sample is limited, preamplification may be necessary. Applied Biosystems recommends a test study without preamplification to determine if the fluorescence signal is sufficient for good allelic discrimination. If you: Need to preamplify the samples, go to Preamplify the samples on page 3. Do not need to preamplify the samples, go to Perform fast genotyping on page 4.

TaqMan Sample-to-SNP Kit Quick Reference Card Table 1 Sample type Blood (freshly drawn, EDTA, citrate, heparin) Blood, cells, saliva (blood cards, FTA paper) Cell culture suspension Preparation of sample lysate according to sample type Sample input Volume of Lysis Solution (μl) Incubation Temperature for 3 minutes ( C) 2 μl 20 Room temperature Volume of DNA Stabilizing Solution (μl) Notes 20 3-mm punch 50 95 50 2 μl 20 Room temperature 20 Buccal swab 1 400 95 400 1. Twist the swab from the cap. 2. Rotate and firmly brush the swab using 20 strokes throughout the inside cheek. 3. Use a 1.5-mL screw-capped tube and immerse the swab into the Lysis Solution. 4. Rotate the swab 5 times. 5. Lift the swab above the Lysis Solution, then press the swab against the side of the tube to squeeze out its contents. 6. Dispose of the swab. 7. Continue preparing the sample (see Incubate the samples on page 1). Rat or mouse tail 1 to 2 mm 50 95 50 Tissue 1 to 2 mm 50 95 50 Hair with follicle 2 to 3 follicles Leaf punch or needle Seed chip Formalin-fixed paraffinembedded tissue (FFPE) 3-mm leaf punch or 2- to 3-mm needle 2- to 3-mm seed chip or 2 to 5 mg pulverized seed 2 to 3 pieces of a 10-μm section The swab may be air-dried, re-capped, then stored at room temperature. 50 95 50 Ensure that the hair and follicles are immersed in Lysis Solution. 50 95 50 50 95 50 200 95 200 Before the lysis step, you can deparafinize the FFPE tissue using a standard protocol. Ensure that the FFPE is immersed in Lysis Solution. Page 2

Preamplify the samples TaqMan Sample-to-SNP Kit Quick Reference Card 1 Prepare the preamplification mix a. Thoroughly mix the TaqMan PreAmp Master Mix (PN 4391128) by swirling the bottle. b. Thaw any frozen TaqMan assay reagents by placing them on ice. Vortex then centrifuge the tubes briefly. c. In a 1.5-mL microcentrifuge tube, combine equal volumes of 20 TaqMan SNP Genotyping assays of up to 100 assays, then dilute the combined assays in 1 TE buffer to a final concentration of 0.2. d. For each sample, combine in a PCR tube the components as shown in the table below. Multiply the volume for one component in the table below by the total number of s, then add that volume of the component to the tube. Preamplification of sample Component for preamplification Volume for one 10-μL (μl) Volume for one 50 -μl (μl) TaqMan PreAmp Master Mix, 2 5 25 0.2 Pooled assay mix 2.5 12.5 Sample lysate 1.2 6 DNase-free water 1.3 6.5 Total 10 50 2 Set up the run method Set up the run method using the following conditions: Thermal-cycling conditions: Stage Step Temp Holding DNA polymerase activation 95 C 10 min Cycling (14 cycles) Denature 95 C 15 sec Anneal/Extend 60 C 4min Run speed: 9600 emulation or standard Reaction volume: 10 μl or 50 μl 3 4 Load and run the plate Load the plate into the thermal cycler, then start the run. Dilute the preamplified samples After the run, dilute the preamplified products 1 to 20 in 1 TE Buffer. Go to Perform fast genotyping on page 4. 5 (Optional) Stopping point For long-term storage, you can store the preamplified sample (undiluted or diluted) at 20 C. Page 3

Perform fast genotyping TaqMan Sample-to-SNP Kit Quick Reference Card 1 Prepare the PCR mix Note: To prepare for fast genotyping, refer to Before you begin fast genotyping in the TaqMan Sampleto-SNP Kit Protocol (PN 4402136). a. Thoroughly mix the TaqMan GTXpress Master Mix before use. Avoid creating bubbles. b. Thaw on ice, vortex, then centrifuge TaqMan assay reagents, sample lysate, or genomic DNA. c. In an appropriate tube, combine the mix components shown in the table below. Determine the volume appropriate to the instrument and plate. Multiply the volume for one component in the table below by the total number of s, then add that volume of the component to the tube. PCR mix components Component Volume for 5-μL PCR (μl/well) Volume for 10-μL PCR (μl/well) Volume for 25-μL PCR (μl/well) TaqMan GTXpress Master Mix (2 ) TaqMan genotyping assay mix (20 ) 2.50 5.0 12.50 0.25 0.5 1.25 DNase-free water 1.25 2.5 6.25 Total 4.0 8.0 20.0 For ease of use, dilute 40 and 80 Assay Mixes to 20 working solutions with 1 TE buffer (10 mm Tris-HCl, 1 mm EDTA, ph 8.0). Use DNase-free water. If you use Custom TaqMan Probes and Sequence Detection Primers rather than a TaqMan genotyping assay, Applied Biosystems recommends 900 nm for primers and 200 nm for probes. d. Cap, vortex the tubes, then briefly spin down the contents to eliminate air bubbles. e. Into each well of a plate, pipette the PCR mix volume (4, 8, or 20 μl) appropriate to your plate. f. Observe the purple tracking dye in each well to ensure uniform filling. g. Seal the plate with a MicroAmp clear adhesive film. h. Centrifuge the plate briefly to spin down the contents and eliminate any air bubbles. i. Remove the clear adhesive film from the plate, then pipette one control or diluted DNA sample into the appropriate well(s). j. Add sample lysate, diluted preamplification product, or DNA control to each well according to the volume of the PCR volume: Volume of sample lysate, diluted preamplification product, or DNA control (μl/pcr ) 5-μL 10-μL 25-μL 1.0 2.0 5.0 k. Cover the plate with MicroAmp Optical Adhesive Film or MicroAmp Optical Caps. l. Centrifuge the plate briefly to spin down the contents and eliminate air bubbles. m. Use a MicroAmp Optical Film Compression Pad when you use a MicroAmp Optical Adhesive Film. Ensure that the gray, nonreflective side of the pad faces down on the plate. Also use a compression pad with a MicroAmp Optical 96-well plate on the 7900HT Real- PCR System. Page 4

TaqMan Sample-to-SNP Kit Quick Reference Card 2 Perform the PCR a. Set up the following run conditions: IMPORTANT! These conditions are optimized for use only with TaqMan genotyping assays on the PCR systems specified in the table below and with the instruments and plates specified in the TaqMan Sample-to-SNP Kit Protocol, Appendix A. Stage Step Temp (StepOne, StepOne Plus,7900) (Fast 7500) (7300, 7500) Holding DNA polymerase activation 95 C 20 sec 20 sec 20 sec Cycling (40 cycles) Denature 95 C 3 sec 3 sec 15 sec Anneal/Extend 60 C 20 sec 30 sec 60 sec Use the minimum extension time available on your instrument but no less than 20 seconds. Run speed: Fast or Standard Reaction volume: 5, 10, or 25 μl b. Load the plate into the thermal cycler, then start the run. 3 Read the plate After PCR amplification, you perform an endpoint plate read on a real-time PCR instrument. IMPORTANT! For all real-time PCR instruments, reagardless of default temperature, use a post-read temperature of 25 C when using the TaqMan GTXpress Master Mix. The SDS software uses the fluorescence measurements from each well made during the plate read, then plots R n (signal) values. The software determines which alleles are in each sample for later allelic discrimination analysis. Refer to the allelic discrimination section of the appropriate instrument user guide for instructions on how to use the system software to perform the plate read and analysis. 4 Analyze the results a. If allelic discrimination is not possible because of low fluorescence, return the plate to the thermal cycler, then perform another 10 PCR cycles using the following thermal-cycling conditions change according to run conditions in previous table: Stage Step Temp (StepOne, StepOne Plus,7900) (Fast 7500) (7300, 7500) Cycling 10 cycles Denature 95 C 3sec 3sec 15 sec Anneal/Extend 60 C 20 sec 30 sec 60 sec Use the minimum extension time available on your instrument but no less than 20 seconds. b. Perform allelic discrimination analysis again to see if the results improve. For optimal results, never exceed a total of 50 cycles. Page 5

TaqMan Sample-to-SNP Kit Quick Reference Card Copyright 2008, Applied Biosystems. All rights reserved. For Research Use Only. Not for use in diagnostic procedures. NOTICE TO PURCHASER: PLEASE REFER TO THE TAQMAN SAMPLE-TO-SNP KIT PRODUCT INSERT AND PROTOCOL FOR LIMITED LABEL LICENSE OR DISCLAIMER INFORMATION. Applied Biosystems, AB (Design) and MicroAmp are registered trademarks and GTXpress, Sample-to-SNP, StepOne and StepOnePlus are trademarks of Applied Biosystems Inc. or its subsidiaries in the US and/or certain other countries. TaqMan is a registered trademark of Roche Molecular Systems, Inc. 09/2008 www.appliedbiosystems.com Part Number 4402745 Rev. A