Extractable and Leachable Challenges From a generic injectable drug development perspective

Similar documents
Contract Manufacturing Services for Pre-filled Syringes

Extractable and Leachable Studies of Parenteral Infusion and Transfusion Products

Dealing with Extractables & Leachables from a Regulatory Perspective - Design of Extractables & Leachables Studies - Safety Assessment of Leachables

Extractables and leachables: An Introduction

Compendial Effort to Revise Packaging Material Standards: Glass, Plastic, Elastomer, and Other

The Use of BPOG Generated Extractables Data for Toxicological Assessment

Teeramanas Tanaekakarapong, a peritoneal dialysis patient

Advancements on implementation of single use technology in vaccine manufacturing

Derivation and Justification of Safety Thresholds

Elemental impurities impact on APIs

Leachable and Extractable Testing

2-2 Sterile Product Assessment. Satish Mallya Ph.D Training Workshop CPH, May 2015

WHO GUIDELINE Stability testing of active pharmaceutical ingredients and finished pharmaceutical products

Packaging of Biotech Drug Products: Challenges and Innovative Solutions. Annalisa Delnevo Research Pharma Odra Pinato SG Lab Analytics

STABILITY TESTING OF NEW DRUG SUBSTANCES AND PRODUCTS

OMICS International Conferences

The GCC Guidelines for Stability Testing of Drug Substances and Pharmaceutical Products EDITION TWO 1428 H 2007 G

Analytical and formulation attributes

FOOD AND DRUGS AUTHORITY

Shoot for Share! From Vial to Pre-filled Syringe

Considerations for Ophthalmic Drug Products in Semi-Permeable Packaging

PQRI Workshop: Leachables and Extractables

GUIDELINE FOR THE STABILITY TESTING

Table 37: Design of Stability Studies for Biotechnology Product Development and Lifecycle Management A New USP Chapter

Product Questionnaire

Developing a Best Practice Guide for Leachables Risk Assessment, Study Design, and Analytical Methods

Table 12: Design of Stability Studies for Biotechnology Product Development and Lifecycle Management A New USP Chapter

ICH Topic M 4 Q Location issues for Common Technical Document for the Registration of Pharmaceuticals for Human Use Quality Questions and Answers

Extractables & Leachables. Ophthalmic Drug Products: A Regulatory Perspective Current Industry Challenges and Case Studies

Aseptic Process Validation

Manual 055 Commercial Stability Testing For Formulated Products. This procedure applies to all drug products. The procedure covers:

Validation Needs for Sterilization by Aseptic Filtration

PHARMACEUTICAL TESTING

Case study 2: Parenteral Drug Product

Colorants in Medical Devices:

Evaluating single-use systems

Technical requirements to Good Manufacturing Practice in metered dose inhalers production and development (2. part) Extractable - Leachable

How to Prepare MedDevice Packaging for Regulatory Success A Chemical Characterization (E&L) Perspective

CMC Strategy Forum Europe 2016

Draft regional guidelines on stability testing of active substances and pharmaceutical products

PQRI PODP Extractables & Leachables Workshop Sources of Leachables for Injectable and Ophthalmic Container Closure Systems

STABILITY: STABILITY TESTING OF NEW VETERINARY DRUG SUBSTANCES (REVISION)

QbD in developing semisolid formulations

ANDAs: Stability Testing of Drug Substances and Products- Industry Perspective

Primary Packaging change: Switch from a lyophilisate in vial to a lyophilisate in double chamber cartridge

Q8 Pharmaceutical Development

Hot Topics in Drug Product Process Validation: A Reviewer s Perspective

PDA Midwest Presentation. Extractable/Leachables Overview. Mike Coon, BD Manager May, 2016

How to Avoid Common Deficiencies in INDs and NDAs. Ramesh Raghavachari, Ph.D. Branch Chief, Branch IX ONDQA/OPS/CDER

Medicine Variations Guideline

HISTORY AND MILESTONES

Medicines Variations Guideline

Vetter Development Service

QUALITY & SAFETY CHARACTERISTICS OF PREFILLABLE SYRINGE SYSTEMS: HAZARD CONCERNS & MITIGATION STRATEGIES

DEVELOPMENT PHARMACEUTICS AND PROCESS VALIDATION

Elemental Impurities: An Industry Perspective

ICH Q3D RISK ASSESSMENT: REGULATORY SUCCESS AND STANDARDIZED METHODOLOGY FOR NEW FILINGS WILLIAM STEVENS- MERCK & CO., INC.

Scalable Strategies for Parenteral Dosage Form Selection

Sterilizing and Bioburden Filter Risk Assessment in Vaccine Processes as part of QRM

United State Pharmacopeia: Compendial Plastic Standards: Beyond Packaging

Formulation Development & CTM Manufacturing Services

PDA: A Global. Association. Extractables and Leachables Aspects in Drug. Product Manufacturing

Commonly Seen Drug Product Related Quality Deficiencies

Single-Use Final Fill: Benefits and Considerations

of the TTC Douglas J Ball, MS, DABT

VICH Topic GL3. Step 7 (after revision at step 9) GUIDELINE ON STABILITY: STABILITY TESTING OF NEW VETERINARY DRUG SUBSTANCES AND MEDICINAL PRODUCTS

Quality Issues for Clinical Trial Materials: The Chemistry, Manufacturing and Controls (CMC) Review

Annex 10. Stability testing of active pharmaceutical ingredients and finished pharmaceutical products. Introduction and background

Presentazione: Use of coupled chromatographic analytical. registration of new medicinal products. Relatore: Dr.ssa Federica Bruno

EVALUATION FOR STABILITY DATA

On the Q&A to the Guideline for Common Technical Documents

Developing a Phase-Appropriate Extractables and Leachables Program

Why change is inevitable in aseptic manufacturing?

AMRI Acquires Whitehouse Laboratories Investment Community Presentation. December 15, 2015

International Pharmaceutical Excipients Council Of The Americas

ontainer Closure Systems

Extractables and leachables: Regulatory requirements for vaccine and biologic products

Regulatory expectations on impurities in drug substances - Pavia, October 2, Luisa Torchio Euticals SpA

NOVEL APPLICATIONS AND PRODUCT DESIGNS: DRIVING NEW REQUIREMENTS FOR ASSESSMENT AND SELECTION

WHO DRAFT PHARMACEUTICAL DEVELOPMENT FOR MULTISOURCE (GENERIC) PHARMACEUTICAL PRODUCTS

Container Closure Integrity Testing Method Development and Validation for Pre lled Syringes

COMMITTEE FOR PROPRIETARY MEDICINAL PRODUCTS (CPMP)

Roadmap of stability studies for Biosimilarproduct development. Head Biotech Stelis Biopharma

ANNEX V ASEAN GUIDELINES ON STABILITY STUDY AND SHELF-LIFE OF HEALTH SUPPLEMENTS

Guidelines for Pharmaceutical Equivalence Requirements

2017 AAM CMC Workshop

Guideline Regarding Non-Containment Management on Fujitsu Group Specified Chemical Substances

WHAT S NEXT FOR STERILE CONTRACT MANUFACTURING IN EMERGING MARKETS?

Delivery of materials (usually finished product from a distribution center) to a first paying customer external to Site

Preparing Your Aseptic Processing Facility for an FDA Inspection. Valerie Welter, Director Quality Bayer HealthCare March 10, 2014

Future of Question-based Review and Regulatory Submissions

Gx Syringe Systems.

Outline. Opportunities Overview of ASAP Areas of Application ASAP Proposal to Regulators Summary

Review Validation of aseptic processes for pharmaceuticals

Extractables and Leachables in Early Phase Development

Global Regulatory Affairs

Solutions for All Your Aseptic Parenteral Drug Formulation/Filling Needs. BUBBLE-FREE FILLING : A New Option in Prefilled Syringe Filling

Why Do I Test, What Do I Test & When Do I Test It? Ross Caputo, PhD Chief Technical Officer Eagle Analytical Services

Key-points of Post approval variation in Korea

Transcription:

Extractable and Leachable Challenges From a generic injectable drug development perspective Andrea Redd Director, US Regulatory Affairs Fresenius Kabi November 8, 2017

Disclaimer This presentation contains a summary of the opinion and perspective from industry representatives on the topic of Extractable and Leachable Challenges. This presentation does not necessarily represent the opinion of the presenter nor its employers.

Generic Small Molecule Perspective 1. Landscape of E/L studies in injectable product development Manufacturing components with bulk solution Finished Products o Plastic containers with label-ink o Lyo products and recon solutions o Liquid products in glass vials or PFS 2. Challenges and Strategies Challenges in workload, cost and timeline Consolidation of choices and centralized extractable database Simulation Study for waiving stability sample monitoring Bracketing of stability samples for leachable testing

Overview of Common Terminology Migration Studies potential impact: what could come out Extractables actual impact: what will come out Leachables Chemical entities that can be pulled from a pharmaceutical packaging/delivery system Needed for all container closure components with direct product contact, including label (with ink and adhesives) and secondary packaging (for plastic containers) Not in drug product Chemical entities that can migrate into an associated drug product formulation Typically a subset of extractables or are derived from extractables. Evaluated over drug product shelf-life Performed in product can be performed during stability batch testing

Manufacturing Components Examples of Component Types Qualification Approaches Recent FDA Deficiency Examples Copyright Fresenius Kabi AG

Component Types Components possibly to contact with bulk solution Tank: Stainless steel, Glass-lined tanks Tubings: Tygon; Silicone; Cflex; Cflex Ultra; Pharmed; PFA (teflon); Silicone Pharma 50; Stainless steel Diaphragms: Red TL silicone; clear TL silicone Filters: PVDF; PES; Nylon66 Filler: Stainless steel, ceramic

Qualification Approaches COMPATIBILITY STUDIES EXTRACTABLE/LEACHABLE STUDIES Compatibility studies often only look at physicochemical properties of DP when in contact with manufacturing components don t always include E/L assessment. First place to go is to vendor! Use extractable report to justify no need for leachable testing Justify leachable not required due to limited product contact time Justify that testing extractables under prolonged stagnant contact time represents worst-case as compared to the transient exposure time the product has with components during routine manufacturing conditions Institute a total contact time (if necessary) for routine manufacturing If leachables were present from the components, this would be detected in the finished product leachable samples as the method would be capable of detecting any peaks.

Example Deficiency Questions Small Molecule Aqueous Solutions FDA Deficiency Question: During the manufacturing process, the drug product exists as a solution and thus has the potential for leachables and extractables from materials. Other than the extractable studies for the proposed filters, extractable/leachables data was not provided for the processing components (e.g., stainless steel vessel, jacketed vessel, silicon tubing) used in the proposed manufacturing process. Please provide this information to demonstrate compatibility between the equipment contact materials and the bulk solution. Response: Consider product properties versus stainless steel Consider available vendor data Consider actual contact times Run studies if still deemed necessary

Co-solvent Bulk Solutions or Drug Product + Diluent FDA Deficiency Question: Please provide additional information to demonstrate that the hold and flush strategies as employed during the manufacturing of the diluent are adequate to mitigate the risk of leachables or to reduce them to levels which are considered acceptable. We note that the control strategies suggested for the bulk solution of drug product are based on compatibility studies; however such compatibility studies as described in the pharmaceutical development report did not discuss potential leachables. Explain why such control strategies applied for Drug Product (DP) manufacturing is adequate and why similar holding and flushing strategies as applied for diluent are not warranted. Response: Consider product properties Consider available vendor data Consider actual contact times Run studies if still deemed necessary Copyright Fresenius Kabi AG

Finished Product Glass Vials Flexible Plastic PreMix bags Pre-Filled Syringe or AutoInjectors

Special Considerations Small Molecule GLASS PLASTIC: If glass is coated (with silicone), a study may need to look specifically for extractables that are coming from coating. Needs to be determined based on the drug product formulation and the potential for it to interact with the coating. Labeling components typically do NOT need to be evaluated Are deemed semi-permeable so also need to consider the secondary packaging as well as port system components (for bags and pre-filled syringes) It is critical to evaluate all labeling components in the extractable study, inclusive of inks, glue, adhesives, etc. LYO PRODUCTS: Typically are not performing leachable studies on lyo products May need to perform leachable studies on reconstituted solution if recon stability times exceed 7 days based on PI (have received deficiency questions from FDA even for shorter recon times)

Basic Extractable Screening Study Design 1. What to Study: Obtain information from vendor of packaging components with direct product contact (includes inks and label adhesives) 2. Selection of Test Method: Based on proposed drug product formulation HPLC GC/MS ICP 3. Baseline Extractable Screening Study: Select a range of representative test solutions in order to develop product families that can be used to cover different drug product vehicles (aqueous products, non-aqueous products (i.e. oil based, emulsions), etc.) o ph adjusted water (ph 2.0 and ph 10.0) o Alcohol mixture (15% ethanol / water or IPA) Subject the test solutions to worse-case parameters (i.e. processed under high sterilization temps) Determine extraction time based on proposed drug product formulation Performed on lab batches filled in the final container closure system- primary container, labels with ink (for plastic), and secondary packaging-if needed

Deficiency Question Examples Recent FDA deficiency questions received: Have asked that extractable studies performed on plastic bags be performed on larger range of solutions, including ph-adjusted water and alcohol Have asked to lengthen the extraction time to > 1 hour Have asked questions specific to potential extractables coming from labels, including ink and adhesives critical to get all available information from relative supplier Recent deficiency question received on Premix Flexible Container:

Ink Qualification Studies for Plastic Containers Qualification of Inks for Primary Container Label: Information on ink and label adhesive must be obtained from relevant suppliers One-time baseline extractable evaluation of label + new ink must be performed on multiple solvents (not just water) ph adjusted water at ph 2.0 and ph 10.0 Alcohol (50:50 ethanol / water mixture) Additional organic solvent as determined by drug product vehicle A new one-time baseline extractable study should be performed on every new ink Could consider development of a multi-color label to serve as worse-case test condition

Example of Lyo Product Limited to no direct stopper contact E&L studies were not typically performed on lyo products due to short contact time (even after reconstitution) Lyophilized products: no direct contact (no extracting force) with stoppers. Recon Solution Leachable study required for Label-claimed prolonged in-use time (>7 days) If multiple recon solutions in PI, may need to perform a leachable study using different recon solutions Example FDA Deficiency: Submit extractable & leachable studies for proposed stopper. Label Claim: Recommended duration for treatment is 5 14 days. Once reconstituted, product may be stored at room temperature(not to exceed 25 C/77 F) for up to 24 hours (up to 6 hours in the vial and the remaining time in the intravenous bag). KEY TAKE-AWAY: Even with limited contact time after recon (24 hours!!), FDA still required extractable AND leachable evaluation. An in-use leachable study was performed. A representative sample of drug product was reconstituted with each diluent and stored inverted at an elevated temperature of 40 C for 24 hours for assessment of leachables.

Leachables Leachables Study Design Example Deficiency Questions Copyright Fresenius Kabi AG

Leachables Study Design 1. What to Study: Based on extractable test results, determine what chemical entities need to be evaluated over product shelf-life 2. Method Development/Verification: Standard extractable methods may not be appropriate due to interference with API. Product specific leachable method may be required. The leachable method validation should meet all appropriate ICH validation parameters 3. Study Design: Studies are product specific (evaluate proposed commercial product formulation) Studies must be performed using the proposed commercial product presentation: Including label, inks, and aluminum overwraps for plastic containers For glass containers, labels are not required. Are typically performed using samples from the ICH stability batch manufacture and evaluated during stability testing over product shelf-life Copyright Fresenius Kabi AG

Proposed Study Requirements Leachable testing should be performed on samples from all exhibit batches For glass or plastic vials, perform leachable testing on inverted samples only A toxicological evaluation must be performed on any leachables seen during stability batch testing Justification needs to be provided based on outcome of literature studies and PPD Proposed stability test requirements: Storage Conditions Initial 3 6 9 12 18 24 36 Long-term X X X X X X X Accelerated X X X NOTE: Additional time points may be required based on drug product formulation, proposed dosage form, and route of administration Copyright Fresenius Kabi AG

Confidential Information Example Deficiency Questions

Case Study: Flexible Plastic Bag Recent FDA deficiency question received: Leachables were not performed on all stability batches Leachables were evaluated at minimal time-points Due to the above issues, FDA has requested that testing for leachables be added to both release and shelf-life product specifications No toxicological evaluation was performed on leachables. FDA has asked for literature to support that leachables have no potential toxicological effects. Excerpt from recent FDA deficiency question: Leachable data on one batch at six months is insufficient to justify the exclusion of leachable testing in the drug product specification. Include monitoring leachable levels on stability until end of shelf-life for the three ongoing registration stability batches, and for each annual batch as part of post-approval stability protocol. Test the leachable levels in the three registration stability batches and the batch for which the six month leachable data were provided. If data from a sufficient number of commercial scale batches show negligible levels of leachables or data are generated to provide accurate PDE for each leachable you may propose to eliminate the leachable test. Copyright Fresenius Kabi AG

Case Study: Pre-Filled Syringe Product Please explain why some of the detected leachables were not detected in the extractable study o Extractable studies were performed by different lab with different methods then lab used for leachable studies. As a result, some of the detected leachables from the migration study were not detected in the original extractable study Please clarify how the migration study was initiated in the absence of fully validated methods. o Methods were not validated until after the T=3 month stability pull date We are unable to locate the extractable and leachable testing to qualify the use of the elastomeric tip cap and plunger stopper o Components were not included in original extractable evaluation so study had to be repeated with all components in order to correlate peaks seen in leachable study to potential extractable compounds It appears that your extractable and leachable studies do not consider the label on the COC syringe. We recommend that the leachable (migration) studies be conducted in the primary container closure which is inclusive of the label on the syringe barrel. Copyright Fresenius Kabi AG Confidential Do Not Distribute

Challenges and Strategies Challenges Faced Overview of Simulated Leachable Approach Copyright Fresenius Kabi AG

Challenges Faced AnalyticalMethods Identification of Source Toxicological Assessment Validation work not completed by T=3 months (for both general screening methods and productspecific methods) Different methods being used for extractable testing vs product specific leachable studies to quantify the same compounds. Since different methods are being used, may not get adequate correlation between potential extractable compounds and leachable peaks Need to clearly identify where extractables are coming from (i.e. primary bag film, stopper, overwrap, etc.) If source is not identified, may not be able to confirm where leachable peaks are coming from Can be time consuming and expensive First approach should be to try and use literature based approach Safety levels is based on Permitted Daily Exposure (PDE) and Maximum Daily Dose If leachable compound is not stable, may be difficult to isolate for evaluation in a toxicological study Copyright Fresenius Kabi AG Confidential Do Not Distribute

Overview of Simulation Study Approach Simulation Study for waiving stability sample monitoring E/L major time consuming and costly: Leachable method validation Leachable testing of stability samples Two Conservative assumptions in the predictions of leachable levels: The extraction rates of extractable/leachable from the IV drug container material follow the Arrhenius equation. The accumulated amount of extracted compounds are linearly proportional to extraction time and may be extrapolated to the product shelf life. Copyright Fresenius Kabi AG

Simulated Leachable Study Approach Copyright Fresenius Kabi AG

Simulation Study Case Study A refrigerated product with 2 year shelf life Extractable study Head-space GC/MS for stopper. 8 compounds were detected. The Permitted Daily Exposure (PDE)/extractable amount is 27. Liquid injection GC/MS & UHPLC/UV/MS for stopper: 65% ethanol /35% water extract. ph 2.5 formic acid extract. The extractables do not pose toxicological concerns. Simulation Study at 55C for 2 weeks The predicted leachable concentrations are estimated to be 3.2 times after two year storage compared to the ones in simulation study or 0.4 ppm x 3.2= 1.3 ppm. This is much less than the TTC (16.7 ppm). Also the inorganic leachable would be much less than the PDE. It is predicted that the potential organic and inorganic leachables would be many times lower than the TTC/PDE and therefore no target leachable monitoring will be performed. This approach accelerates and reduces the cost of medical product development. Copyright Fresenius Kabi AG

Questions Questions?

Thank You!