6A V CVQ cable (C rank)

Similar documents
6A-51 DV wire (C rank)

6A-089: 600-V CV Cables (Rank C)

6A-38 Jumper Wire (IJP) (Rank A)

6A-33 SN-HAl-OC wire (A rank)

MATERIAL STANDARD FOR CABLES AND WIRES

11-SDMS-01 REV. 03 ( )

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. TB/T Translated English of Chinese Standard: TB/T1484.

THERMOFIT AP2000 TUBING HEAT-SHRINKABLE CROSSLINKED MODIFIED POLYOLEFIN, ADHESIVE LINER

SPECIFICATION OF LT AERIAL BUNCHED (AB) CABLES (Size: 3C x 35mm² +1C x mm²) FOR LT LINES (APPLICABLE FOR LT AB CABLE WITH XLPE INSULATION ONLY)

2. RATED VOLTAGE: The rated voltage of the AB cables shall be 1100 volts

10-SDMS-02 SPECIFICATIONS FOR BARE COPPER CONDUCTORS

5.2 The phase conductors shall be provided with one, two & three ridges for easy identification.

SPECIFICATION FOR FRLS POWER CABLES

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

ES2000 TUBING Environmental Sealing, Polyolefin, Semirigid, Adhesive-Lined

6C-001 High-Voltage Pin-Type Insulator

SOUTH CAROLINA ELECTRIC COOPERATIVES' PRIMARY UNDERGROUND POWER CABLE SPECIFICATION

PRODUCT SPECIFICATION

THERMOFIT ADHESIVE S-1125 Epoxy, Flexible

TECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 23, 2018

L1-CHE-SPE-171 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE

SPECIFICATION CONTROL DRAWING

PRODUCT SPECIFICATION

Raychem RT-555 TUBING Modified Fluoropolymer, Radiation Crosslinked, Flexible, Abrasion Resistant, Flame Retardant, Heat Shrinkable

3M Optical Fiber Cable Specification

HDPE Conduit Specification 2011

Raychem S1297 and /97 Hot Melt Adhesive

1.1 All testing apparatus shall be periodically checked and calibrated records of such checks/calibration shall be maintained.

RAYCHEM NT-MIL TUBING Modified Chlorinated Polyolefin, Elastomeric, Flexible, Flame Retarded, Heat Shrinkable

Test Report No.: Page 2 of 34

COMPILED BY FUNCTIONAL RESP. APPROVED BY AUTHORIZED BY TABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES...

This translation is provisional translation for reference, formally refer to the original text.

DS131 EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)

3 MODIFICATIONS TO EXISTING STANDARDS

TECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1

3. TEST METHOD FOR BOND PROPERTIES OF CONTINUOUS FIBER SHEETS TO CONCRETE (JSCE-E )

SECTION A. ASTM B3 - Standard Specification for Soft or Annealed Copper Wire; 2013.

*** Supercedes: BECO E and COM , , & ***

Raychem Fluoroelastomer Tubing Flexible, Fluid Resistant, Heat-Shrinkable

Thermofit Polyolefin Molded Components Flame-Retarded. Semi-Rigid, Heat-Shrinkable

SECTION 7.3 TECHNICAL SPECIFICATION OF POWER CABLES & CONDUCTOR

Test Report No.: Page 2 of 35

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

SURFACE VEHICLE STANDARD

ISO 6722 INTERNATIONAL STANDARD. Road vehicles 60 V and 600 V single-core cables Dimensions, test methods and requirements

NEMA Standards Publication No. WC ICEA Publication No. S

ITEM 435 ELASTOMERIC MATERIALS

WIRES, CABLES AND CORDS

FURUKAWA ELECTRIC TAPE FOR ELECTRICAL USES

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

WSD 1800 Issue C Rated Ford Automotive Sensor Cable Specification

STANDARD SPECIFICATION FOR SIGNAL CABLE. A. This Specification provides for single and multi-conductor insulated and jacketed cable for

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS GUARDRAIL AND HANDRAIL. January 24,

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS GUARDRAIL AND HANDRAIL. January 24,

TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 4

TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE

Proposal for the 03 series of amendments to UN Regulation No. 118 (Burning behaviour)

WESTERN UNDERGROUND COMMITTEE GUIDE 3.6 (3.6/02/0588)

Protection of A/C connection using a heat shrinkable jacket

SPECIFICATION OF NEOPRENE RUBBER SEALS

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITH METALLIC SCREEN

1. All Members of Power Cables Sectional Committee, ET 09; 2. All Members of Electrotechnical Division Council; and 3. All other Interested.

Specification This Issue: Date: Replaces: RT-780_Type-I Issue 5 November 10, 2009 Issue 4. Raychem

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)

ENGINEERING SPECIFICATION NON-MAGNETIC RAISED FLOOR SYSTEM FOR MRI ROOM APPLICATIONS

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 22 kv, SINGLE CORE, 95mm 2 COPPER

Technical Specification for Insulated Low Voltage Single Core Copper Cable

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

EAST AFRICAN STANDARD

RB 107 Specification DuraSeal Splices

THERMOFIT SCL TUBING Polyolefin, Selectively Crosslinked, Semirigid, Heat Shrinkable

THERMOFIT RNF-150 TUBING Flexible, Heat-Shrinkable, Flame-Retarded Modified Fluoropolymer

Four Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES FIBERGRATE MOLDED GRATING WITH GRATING PEDESTALS. January 24,

MATERIAL SPECIFICATION FOR BEARINGS - ELASTOMERIC PLAIN AND STEEL LAMINATED

PART MATERIAL REMARK Metal Case with Pig-tail. Brass (Metal Case) Copper (Pig-tail) Star Contact Copper Silver Plated

PLASTIC PIPE TERMS & DEFINITIONS

THERMOFIT ADHESIVE S Flex Fluid Resistant, High Temperature, One Part-Flexible Epoxy

U.V resistance UL Sunlight Resistance. Flame retardant IEC

SPECIFICATION RW-2514 Document Number NBC MARKER SYSTEM (Ladder Form) NBC-SCE

MATERIAL SPECIFICATION FOR BEARINGS - ELASTOMERIC PLAIN AND STEEL LAMINATED

TABLE OF CONTENTS. Use of this specification or any other specification shall be according to the Contract Documents.

WESTERN UNDERGROUND COMMITTEE GUIDE 2.14 (2.14/01/0990)

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

PRODUCT INFORMATION ÖLFLEX CRANE. Info Suitable for outdoor use Integrated supporting element Also suitable for power chains and cable trolley systems

PTFE BELLOWS POLY FLUORO LTD. POLY FLUORO LTD.260A. Bommasandra Industrial Area, Hosur Road, Bangalore TECHNICAL SPECIFICATION

An Urgent Bulletin from CSA International

Standard Specification for Extruded and Compression Molded Shapes Made from Poly(Vinylidene Fluoride) (PVDF) 1

PERFORMANCE SPECIFICATION SHEET

CONTINUOUSLY TRANSPOSED CABLE

FURUKAWA ELECTRIC TAPE FOR ELECTRICAL USES

Highly Flexible Heat-resistant Aluminum Cable and Connection Technology for HEV/EV

Transcription:

6A-31 600V CVQ cable (C rank) Enactment in July 1977 Approved on June 27, 2008 (revised 02) Enforcement on July 28, 2008 Distribution Department Tokyo Electric Power Company, Incorporated.

1. Scope of application This product shall be used for a trunk cable for low voltage underground construction works and incoming electrical line for our customers. 2. Type Copper conductors are used, and the following types are classified based on the number of wire cores and conductor cross-sectional areas. Table 1 Conductor The number of wire cores Copper 4 Conductor cross-sectional area (mm 2 ) 4 22 3 60 + 1 38 3 100 + 1 60 3 150 + 1 100 3 250 + 1 150 3. Structure and materials 3.1 General matters This product is a 600V single-core 4 wire-stranding type cross-linked polyethylene power cable. For the product, copper conductors are insulated by cross-linked polyethylene, and compounds (hereinafter vinyl ) mainly consist of vinyl chloride resin as a protective coating. An insulation layer shall have sufficient insulation, and there shall not be any cracks, air bubbles, etc. on the layer. A protective coating shall have flexibility, high insulation, high waterproofness and durability, and any cracks, peelings and abrasions shall not be observed. 3.2 Conductors As for conductors, annealed copper wires prescribed in JCS C 3102 (annealed copper wires for electricity) or other similar kinds shall be used. A round compression strand shall be mainly made by twisting a strand concentrically and compression-molding it in a circular shape. The direction of an outermost layer twisting shall be right (S). 3.3 Insulators Cross-linked polyethylene is covered concentrically on conductors with a thickness of the attached table. However, dropping of cross-linked polyethylene into conductors shall be avoided. In this case, a separator can be installed in a part where cross-linked polyethylene touches to conductors. The average thickness of insulators must be more than 90% of a value from the attached table, and a minimum measured value must be more than 80% of the value from the attached table. Furthermore, thermoplastic materials by using cross-linked polyethylene coating materials from the removed parts of power distribution equipment of our company (in the rest, we called them as XLPE recycled materials) mixed with polyethylene raw material shall be used for insulators. However, the mixing rate of XLPE recycled materials shall be 25%. 2

3.4 Identification of wire cores By coloring insulators in ink or other appropriate methods, wire core identification shall be performed as in the following. 4 core cables black, white, red and green (However, green is used for the color of neutral lines.) 3.5 Sheath Black vinyl shall be coated on wire cores with a thickness shown in the attached table. The average sheath thickness must be more than 90% of a value from the attached table, and a minimum measured value must be more than 85% of the value from the attached table. 3.6 Wire stranding Each vinyl sheathed wire core shall be twisted toward the right (S). The pitch of wire stranding is less than 20 times of a finished outer diameter. 3.7 Terminal treatment Both ends of a cable shall be sufficiently sealed by using molded caps made of vinyl. 3.8 Naming of a product Naming of a product is shown as in the following example. Example: '600V single-core 4 wire-stranding type cross-linked polyethylene insulated vinyl sheath power cable 3 x 250 + 1 150 mm 2 ' or '600VCVQ 3 x 250 + 1 150 mm 2 ' 3.9 Dimensions Dimensions are based on the attached table as a standard. (The section below is intentionally left blank) 3

4. Performance Cable performance is as in Table 2 when tests in Section 6 are carried out. Table 2 Tensile strength and elongation Item Conductor resistance Withstand voltage Insulation resistance Cross-linked polyethylene insulator Vinyl sheath Value in the attached table or less Performance A test voltage from the attached table shall be withstood for 1 minute. Value in the attached table or more At room Tensile strength 10 MPa temperature Elongation More than 350% Retention after Tensile strength More than 80% of a value before heating heating Elongation More than 80% of a value before heating At room Tensile strength 10 MPa temperature Elongation More than 120% Retention after Tensile strength More than 85% of a value before heating heating Elongation More than 80% of a value before heating Thermal deformation resistance The decreasing rate of thickness Insulator Less than 40% Vinyl sheath Less than 50% Oil resistance Cold resistance Vinyl A test specimen shall not be broken. Flame retardant Vinyl Disappearing in less than 15 seconds without burning Tensile strength Vinyl More than 80% of a value before oil immersion Retention after oil immersion Elongation Vinyl More than 60% of a value before oil immersion 4

5. Wire display The following items shall be continuously displayed on wire cores in an appropriate way that they cannot be erased easily. Furthermore, in the case of using XLPE recycle materials, CVQ/R shall be displayed. a. Nominal voltage: Example: '600 V' b. Product name and its abbreviation: Example: ' CVQ' c. The number of wire cores and a conductor cross-sectional area: Example: '3 x 150 + 1 x 100 mm 2 ' d. Name of manufacturer or its abbreviation e. Date of production Example :'2008' f. A product to which electrical appliances and materials safety act applies shall display type certification. 6. Tests and inspection methods 6.1 Appearance inspection One shall examine a scratch, the smoothness of a surface, a color display, etc. by eyes, textures, etc. 6.2 Structure inspection A sample whose length is about 200mm is taken, and this test shall be performed by Section 4.3 of JIS C 3005 (test methods for rubber and plastic insulation wires). 6.3 Conductor resistance test This test shall be performed by Section 4.4 of JIS C 3005 (test methods for rubber and plastic insulation wires). 6.4 Insulation resistance test This test shall be performed by Section 4.7 of JIS C 3005 (test methods for rubber and plastic insulation wires). 6.5 Withstand voltage test This test shall be performed by Section 4.6 (a) Underwater of JIS C 3005 (test methods for rubber and plastic insulation wires). 6.6 Insulator test (1) Tensile test a. Testing at room temperature This test is performed by Section 4.16 of JIS C 3005 (test methods for rubber and plastic insulation wires). Furthermore, a strain rate is as in Table 4-B. The grip part of a dumbbell-like test piece 5

b. Heating test This test shall be performed by Section 4.17 of JIS C 3005 (test methods for rubber and plastic insulation wires). Furthermore, a strain rate is as in Table 4-B. After heating a test piece for 96 hours in the circulating air at 120±3 c, take it out, leave it for 4 hours at room temperature, and perform a test described in Section 6.6 (1) a within 96 hours. (2) Heating deformation test a. Preparation of a test piece A test piece shall be prepared by cutting out a wire core whose length is about 30mm from a finished product. However, the length of a conductor can be more than 30mm. b. Test method Measure the thickness t of a test piece as in the following figure. Heat up the test piece and a heat deformation testing machine in advance for 30 minutes at 120±3 c. After that, place the test piece between parallel plates, and add a load as described in the following table. After 30 minutes, at the same condition and temperature, measure the thickness of a test piece. Calculate the decreasing rate of thickness by using thickness before heating and thickness after heating as follows. Conductor cross-sectional area Load (N) (mm 2 ) 22-38 14.7 60 19.6 100-200 24.5 250 29.4 Pressure direction Parallel plates Test piece t = Insulator thickness d = Conductor diameter D = Insulator outer diameter Conductor 6.7 Sheath test (1) Tensile test a. Testing at room temperature This test shall be performed based on Section 6.6 (1). However, a strain rate shall be 500 mm/min. b. Heating test The test shall be performed based on Section 6.6 (1). However, a sample is heated at 100 ± 2 c for 48 hours. (2) Heating deformation test The test shall be performed based on Section 6.6 (2). However, a test piece and a load are as below. 6

a. Test piece Take a piece whose length is approximately 30 mm from a finished product. Place the piece parallel to a wire axis direction and cut it in the shape of an arc to form a test piece. b. Preparation of a test piece Place a test piece on a rod whose length is about 35mm and sectional shape is semicircular with the same diameter as the diameter of a conductor or wire core before a test piece cutting out. (See a figure below) c. Load Loads described in the following table shall be applied. Conductor cross-sectional area Load (N) (mm 2 ) 22 7.35 38-250 9.81 Pressure direction Parallel plates Test piece Rod t = Sheath thickness d = Diameter of semicircular rod D = d + t t = D - d (3) Cold resistant test a. Preparation of a test piece A test piece whose length, width and thickness are 38.0±2.0mm, 6.0±0.4mm and 2.0±0.2mm shall be prepared. However, in the case when it is impossible or inappropriate to sample a test piece from a finished product, take a compund whose quality is same as that of the product and prepare a test piece. b. Cold resistant testing machine This machine consists of a striking tool that gives a blow to a test piece gripping tool and a test piece at a constant speed and a thermostatic chamber that keeps the temperature of the test piece constant. As in the figure below, a test piece gripping tool can hold a test piece tightly as a cantilever, and it needs to pick up a test piece whose length is more than 6.3mm at least. Also, a diameter for the tip of a striking tool is 1.57±0.12mm, and when a blow is given to a test piece as well as after that at least, the striking tool must operate at a uniform linear velocity of 1.97±0.15mm/sec while a distance of 6mm approximately is traversed. As for the relative position of the striking tool and the gripping tool, a distance between the central line of the striking tool and the edge of the gripping tool must be 7.92±0.25mm as shown in the following figure. During and soon after striking, a space between the striking tool and the gripping edge must be always 6.35±0.25mm. A thermostatic chamber can maintain the prescribed temperature of a medium uniformly. 7

Blow Striking method R 1.57±0.12 Unit: mm Gripping tool Test piece 6.3 and over 6.35±0.25 c. Test method In this method, take a liquid that does not affect on a test piece at -15±0.5 as a heat transmitting medium (hereinafter medium ). Put the medium in a testing machine in advance and adjust it at -15±0.5 c. Install a test piece gripping tool and soak the test piece into the medium for 2.5±0.5 minutes. After that, record a temperature, give a blow, and examine if it is damaged or not. Here, a test piece is damaged means that it is cracked into more than two pieces, and the generation of a chink or a break does not include for that. (4) Oil resistance test In this test, take a test piece prepared by Section 5.6 (1) and soak it in the oil (#2) of JIS K 6301 at 70±3 for 4 hours. After that, take out the piece, wipe surplus oil attached to its surface lightly, and leave it at room temperature for 4 hours. Then, within 96 hours, measure a tensile strength and elongation by using Section 5.6 (1), and calculate retention by the following equation. However, a cross-sectional area is a value calculated by Section 5.6 (1) before oil immersion, and a reference line shall be marked after oil immersion. (5) Flame retardation test In this test, take a test sample whose length is about 300mm, and hold it horizontally. The central part of the test sample shall be combusted from the bottom for 30 seconds by the oxidizing flame of a spirit-lamp whose length is about 50mm or the tip of the reducing flame of a Bunsen burner whose length is about 130mm. After the flame is put off gently, examine if the ignited flame on the sample is quenched or not within 15 seconds. Furthermore, take an appropriate way to prevent a flame from flickering in a breeze. 6.8 Test for the degree of cross-linking When XLPE recycled materials are used for insulators, a test for the degree of cross-linking shall be performed to the XLPE recycled materials after heat plasticization. The test shall be performed based on Section 4.25 of JIS C 3005, and the degree of cross-linking shall be 40% or less. 7. Test and inspection 7.1 General matters Section 7.2 Model test, Section 7.3 Manufacturing process inspection and Section 7.4 Acceptance inspection shall 8

be performed by using Section 6 Test method, and this product must pass all the above provisions. 7.2 Model test To confirm manufacturer s quality standards, a model test shall be carried out as in the following test items and must conform to the provisions of Sections 3 and 4. Furthermore, a sample is a drum whose cable length is 100 m or more. (1)Appearance inspection (2)Structural inspection (3)Conductor resistance test (4)Insulation resistance test (5)Withstand voltage test (6)Insulator test a. Tensile test (a)testing at room temperature (b)heating test b. Heating deformation test (7)Sheath test a. Tensile test (a) Testing at room temperature (b) Heating test b. Heating deformation test c. Cold resistant test d. Oil resistance test e. Flame retardation test (8)Cross-linking degree test (for XLPE recycled materials) 7.3 Manufacturing process inspection In performing a model test, to confirm that the exactly same product as a model test product is produced in a production process, a series of inspections such as materials used, quality management items of each production process, quality control methods, defect countermeasures, quality management systems, etc. shall be generally carried out. 7.4 Acceptance inspection Acceptance inspection shall be performed by a method described in Section 7.2 Model test under supervision if it is directed by product delivery destination. Also, specific test items and a sampling rate are consulted with customers at delivery destinations. If the acceptance inspection is carried out without any supervision, manufacturers shall perform an in-house test predetermined after consultation with our company and submit a test report to customers at delivery destinations. 9

8. Other 8.1 General matters (1) Except items prescribed in this specification, necessary items to satisfy product performance and functionality shall be determined after consultation with our company. (2) This specification can be changed with our company s approval if substantial profits are expected for use and in manufacturing by changing a part of it. (3) When deemed necessary by our company, process on-site and material inspections, etc. can be performed. 8.2 Packing A strand of cables shall be wound around a tough drum, and its starting part is held outside of the drum. The drum must have strength so that its winding frame etc. perfectly withstands by a fall from the height of 50cm on a wooden board. (The body diameter of a drum is more than 12 times of the outer diameter of a finished cable.) Also, the following items shall be displayed on the side of a drum in an appropriate way that they cannot be erased easily. a. Name b. Nominal voltage c. The number of wire cores d. Nominal cross-sectional area e. Length f. Net mass g. Total mass h. Name of a manufacturer or its abbreviation and a registered trademark i Date of production 8.3 Load of testing products A product used for testing, specimens and implementation costs shall be paid by a deliverer or an applicant for inspection. 8.4 Documents to be submitted 8.4.1 Production specification In order that our company evaluates compliance with this specification, the following (1)-(5) and necessary items shall be stated in a production specification specifically, and a figure with dimensional tolerances and materials shall be attached. Also, technical references according to the production specification shall be attached if necessary. (1)Conductor : Materials, configurations, outer diameter, performance, pitch (2)Insulator : Guarantee limit of materials, performance, scratches and bubbles on the surface of coating, etc. (3)Display : Display method (4)Finished outer diameter : Wire core outer diameter (5)Packing : Method, dimension, display 10

8.4.2 Test result list A model test described in Section 7.2 shall be carried out, and its result and test conditions shall be stated. 8.4.3 Quality management report Contents concerning to materials used, quality control items for each production process, quality control methods, defect countermeasures, quality management systems, etc. shall be specifically described in quality management process diagram, outsourced supplier management, etc. Furthermore, in the case when main production processes are outsourced, outsourced process control documents (that show the status of outsourced process managements and is described as in the format of a management process diagram) shall be submitted. The scope of a specific description shall be consulted with our company. 8.4.4 Technical references For the model review, to determine product performance and quality adequately and properly, the following technical references shall be submitted. Also, submission of technical references other than the below is sometimes requested. (1) In the case of using XLPE recycling materials for insulators, the technical description of the following items shall be reported individually. (a) Conditions for thermoplasticity (b) Quality assurance after repeatedly recycling (c) Technical references on removing foreign substances and impurities of recycled materials and quality control methods Attached table the structure table of a 600V copper conductor single-core 4 wire-stranding CVQ cable. The number of wire cores 4 3 + 1 3 + 1 3 + 1 3 + 1 Conductor Nominal cross-sectional area mm 2 22 60 38 100 60 150 100 250 150 Shape Round compression Round compression Round compression Round compression Round compression Outer diameter (mm) 5.5 9.3 7.3 12.0 9.3 14.7 12.0 19.0 14.7 Insulator thickness (mm) 1.2 1.5 1.2 2.0 1.5 2.0 2.0 2.5 2.0 Outer diameter after insulation (mm) 7.9 12.3 9.7 16.0 12.3 18.7 16.0 24.0 18.7 Sheath thickness (mm) 1.5 1.5 1.5 1.5 1.5 1.6 1.5 1.8 1.6 Outer diameter with a sheath (approx. mm) Finished (wire stranding) outer diameter (approx. mm) Conductive resistance 20 (Ω /km) Electric test Testing voltage (V.1 min.) Insulation resistance (M Ω.km) 10.9 15.3 12.7 19.0 15.3 21.9 19.0 27.6 21.9 27 36 44 52 64 0.849 0.311 0.491 0.187 0.311 0.124 0.187 0.0754 0.124 2000 2500 2500 3000 2500 3000 3000 3000 3000 1500 1000 1500 1000 1000 900 1000 900 900 Approximate mass (kg/km) 1230 2630 4180 6160 9850 11

12