UNITHERM ... How to order: X X A X X. Single Process Line How to order: X X X X X. Multiple Process Lines

Similar documents
ENGINEERING DESIGN GUIDE UNITHERM...

TECHNICAL SPECIFICATIONS

Thermon. Cellex TubeTrace. Tubing Bundles BSX TM. Self-Regulating Heating Cable. Now with IEC Ex Product Specifications

Parflex Multitube Instrument and Heat Trace Tubing Products. Catalog 4200-M-2 July 2006

Catalog 4200-M-2 July CAT 4200-M-2 Parflex Division - Multitube Instrument and Heat Trace Tubing Products

Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing

Insulated Jacketed Tubing

Single-Jacketed Tubing

Pre-Insulated Tubing Bundles

OSNALINE. Tubes and tube bundles. Member of the KME Group. KME Germany AG & Co. KG [GB] OSNALINE

Tubes and Pipes. Tubes and Pipes D-02

Hydraulic & Offshore Supplies. Seamless Coiled Tube YOUR GATEWAY TO GLOBAL SUPPLY

U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration Plastic Pipe

Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing JACKETED /

ASME B31.3 Process Piping

DUO-THERM 505 Specification Guide

Hg Umbilical Installation Guide

PFA (Fluororesin) coated temperature sensors

SECTION HVAC PIPING

SELECTION GUIDE Sample Transport Tubing

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket.

Diaphragm seal with flange connection Cell-type with extended diaphragm Model

26/35kV Copper XLPE Insulation Electric Cable

ENGINEERED SOLUTIONS.

SELECTION GUIDE Sample Transport Tubing

Lined Pipes and Fittings

SAMPLE COOLERS LARGEST SELECTION OF MODELS OFFERED BY ANY MANUFACTURER WATER STEAM PROCESS LIQUID/GAS.

Heavy Wall Heat Shrinkable Tubing 5-7. Flame Retardant Heavy Wall Heat Shrinkable Tubing 8. Heat Shrinkable Ends Caps 9

F = Polyethylene R = Fire Resistant Polyethylene FR = Flame Retardant Polyethylene N = Nylon Q = 25' L = 50' C = 100' 50 = 1/2"

NEOTISS TM HPT finned TubES

SECTION HYDRONIC PIPING

PAGE International designs and manufactures custom engineered Fluoropolymer

HT-406 Specification Guide

gyrolok Flareless Tube Fittings Tubing Data Charts Index

TRICON DOUBLE-CON PLUS

CAJ. Combos. C-AJ of 5. Through Penetrations Series. Concrete. 3Fire Protection Products

Heating Cables DATASHEET

Diaphragm seal with flange connection With internal diaphragm Model

Gyrolok. Gyrolok Flareless Tube Fittings Tubing Data Charts

Design and Construction Standards SECTION HYDRONIC PIPING

ENHANCED TYPE G HIGH EFFICIENCY TOWER PACKING (ETG)

Tubing and Pipes.

SECTION HYDRONIC PIPING

System No. SP777 (FOR HORIZONTAL OR VERTICAL SEPARATIONS)

SECTION HYDRONIC PIPING

Diaphragm seal with threaded connection Threaded design Model

STATE UNIVERPROGRAM DIRECTIVES

HVAC Piping Insulation FIBERGLAS Insulation. General Specification Guide SECTION

Target Inline Flowmeter

Single Lumen Tubing. Multi-Lumen Tubing. Quality Commitment:

HVAC Piping Insulation- FIBERGLAS Insulation

System No. C-AJ-8096

SURFACE TEMPERATURE SENSORS

*Nominal values are to be used as guidelines only; this is not a product specification and does not indicate minimum or maximum values.

A. Submit to the Engineer as provided in Section shop drawings showing details of construction and erection for each tank as follows:

Section D Thermoplastic Tubing

UBC Technical Guidelines Section Edition Thermal Insulation for Piping Page 1 of 5

Bare Hard Density Pigs Used for drying and mild cleaning. Fully Coated Hard Density Pigs Withstands 5% presence of H 2

Diaphragm seal with flange connection With internal diaphragm, threaded design Model

UNIVERSITY OF MISSOURI Hydronic Energy Distribution 2016 Q1

Section D Thermoplastic Tubing

Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing

ISO 9001:2008 certified

.1 Thermal insulation for insulated piping and piping accessories affected by construction and new pipe sections as indicated on drawings.

Analytical instrumentation mechanical marine

PVC. System Specifications TABLE 1 TABLE 2

Datasheet Rev.1 Feb 2016 Orifice plate multi-holes

SANDVIK SPRINGFLEX SF SPRING WIRE WIRE

INSTALLATION GUIDELINES FOR CHILL WATER PIPE INSULATION

Installation Guide BLUE904 PEX MUNICIPAL WATER SERVICE TUBING. We Build Tough Products for Tough Environments

PIP PNSC0035 Steam Tracing Specification

Dynalene Ethylene Glycol Series

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR

ASME B31.3 Process Piping. 19. What s Different in B31.1

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 23, 2018

GREEN THREAD Piping Systems

STAINLESS STEEL PIPE/TUBE & PIPE FITTINGS

A. This section is intended to provide design guidelines for Utility Direct Buried Piping and Conduit Systems.

Lifting Lug Standard on all units, for ease of installation. Multi-Ply Bellows Laminated bellows offer maximum flexibility and endurance ONS

Altaflo is an innovative producer of high performance fluoropolymer and fluoroplastic tubing and pipe.

Heat Transfer Compounds

6.1 General. This chapter shall provide requirements for correct use of sprinkler system components and hardware.

JUMO flowtrans DP P. Pitot tube P01 to P04. Applications. Brief description. Special features. Customer benefits

Tubing Data. Contents. Tubing Selection. Tubing Handling. Tubing Material. Tubing Outside Diameter Hardness. Tubing Wall Thickness

Specification for Crosslinked Polyethylene Double-Wall Storage Tank with Enclosed Secondary Containment

Parflex/Atlantic. Fluoropolymer Tubing Products. Catalog 4150/USA March 2003 revised Sept. 2003

D-10 OUTLINE SPECIFICATION FOR PRE FAB Undergrd Piping System

Stainless Steel Seamless Tubing and Tube Support Systems

Special Provision for LRFD Pipe Culvert Burial Tables

H A N D Y & H A R M A N T U B E C O.

Ice Rink Renovation & New Clubhouse

Match your Inspection Ports to your Process Temperatures

Application Note AN 84/01. Pressure Transducer Temperature. Isolation Using Tubing. (Steady State Condition)

Steam Tracing 1 / 5. Fig. 1 Typical steam-tracing layout

APlus-QMC LLC. Catalog 2017

According German Standard DIN part 1. Standard range of PVC-P based flexible waterstops for movement (expansion) and construction joint sealing

3M Cold Shrink Silicone Rubber Connector Insulators 8440 Series

Series K7130 Heavy Wall PVC Transfer Hose. Compound hardness 73 ±3 Shore A. Self-extinguishing. Non-marking, non-toxic and silicone-free.

SECTION HVAC INSULATION

Transcription:

UNITHERM.... UNITHERM 2202/2204 LIGHT-STEAM TRACE TUBING Principal of Operation Unitherm 2202/2204 pre-insulated steam trace consists of single and multiple process lines; single tracer line; moisture resistant, non-wicking, inorganic fibrous glass thermal insulation; and a black 105ºC PVC jacket. It is designed for light tracing of process, sampling and impulse lines to help prevent freezing, and protect the process fluids against high temperature degradation. Recommended for use where heavy tracing (2201/2203) will cause high temperature degradation or boil off of the process fluids. This highly efficient, compact product is designed to limit the jacket to a nominal surface temperature of 1ºF (60ºC) or lower at 80ºF (26ºC) ambient conditions, with tracer temperatures at 0ºF (204ºC) 232.6 PSIG saturated steam. Higher temperatures designs for tracing applications up to 1000ºF are available. Features Pre-Insulated & prefabricated for fast, easy installation Light, durable and easy to handle Maintenance free Consistent and predictable thermal characteristics Personnel protection Applications Analyzer and Instrument lines Small diameter process lines Impulse lines-d/p cells How to Specify Example: 2202-20A21 Unitherm steam trace tubing (1) 1/4 x wall 316-Welded S/S process tube; (1) 1/4 x wall #122 copper tracer line; moisture resistant, non-wicking, inorganic fibrous glass thermal insulation; 105ºC black PVC jacket; MTR*= 0ºF * Maximum Temperature Rating is the design condition for which this product is manufactured. Temperatures in excess of this rating may result in deterioration of the components or changes in the operational characteristics. How to order: 2202- X X A X X Single How to order: 2204- X X X X X Multiple s 2 = 3 = 4 = 5 = 5/8 6 = 3/4 Material 0 = 316 S/S Welded 1 = #122 4 = PFA Fluoropolymer 7 = 316 S/S Seamless Number of s A = 1 B = 2 C = 3 2= 3= 4= Material 0= 316S/S Welded 1= #122 7=316 S/S Seamless List above shows most common product configurations. Alternative tube sizes, wall thickness and materials, as well as, alternate jacket materials are available upon request. See page 3 for expanded list of product offerings. Form 2202/4LTSTM 0103 Copyright 2003 Dekoron/Unitherm. All rights reserved

TECHNICAL INFORMATION UNITHERM 2202/2204 LIGHT-STEAM TRACE TUBING Performance Specifications 2202/2204 Product Nominal Jacket Surface Temperature With 0ºF (204ºC) tube and 80ºF (26ºC) ambient 1ºF (60ºC) Nominal Heat Loss at 0ºF (204ºC) inside and 80ºF (26ºC) ambient BTU/HR/FT (2) (2) Product Specifications Jacket 105ºC Black PVC Insulation Moisture resistant, non-wicking, Inorganic Fibrous Glass 5/8 Standard Thickness*** Material (1) ASTM Working Pressure @ 0ºF 600 psi 450 psi 360 psi 530 psi 415 psi 5170 psi** 3310 psi** 2430 psi** Max. Coil Length 100 * * * Metric available 6,8 and 10 mm x 1 mm WT Standard *** Heavier wall thickness available (1) Other tube materials available upon request * Longer coil lengths available upon request ** Values given are for welded. Seamless slightly higher Profile: 2202 Product (Typical) See page 5 for enlarged graph (For other tube sizes, ambient and steam pressures, refer to Engineering Design Guide for Steam Traced Products.). Product Rating (2) (2) 0ºF (204ºC) Bundle 1.4 1.5 1.6 1.7 1.8 1.8 1.9 Nominal Weight (lb/ft.).6.6.7.7.8.9 1.0 Min. Bending Radius 10 12 12 14 14 16 18 Profile: 2204 Product (Typical) See page 6 for enlarged graph Installation Recommendation See Installation Guidelines for details. Maximum Support Centers Vertical 15 Ft. Horizontal 6 Ft. Minimum Recommended Slope for Condensate Run-Off (steam Applications) 3/4 Per Ft. Minimum Installation Temperature for PVC Jacket +15ºF(-9.4ºC) Alternate flame retardant jacket materials available include: Low Temperature Flame Retardant Polyvinyl Chloride Flame Retardant Urethane Flame Retardant Thermoplastic Elastomer Copyright 2003 Dekoron/Unitherm. All rights reserved Form 2202/4LTSTM 0103, Cape Coral, FL 33909 Toll Free 800.633.5015, Phone: 239.995.8111 FAX: 239.995.8027 UNITHERM

PRODUCT DERIVATION UNITHERM.. DEKORON/UNITHERM Product Derivation Dekoron/Unitherm Light Steam Trace Tubing MTR 0ºF 2202- X X A X X - X X X - X X - X X X - X 2204- X X X X Material Number s Material Thickness Jacket Material 1=1/8 0=Wld T316 SS A=1 1=1/8 0=Wld T316 SS L=Light 0=FR PVC L=Light S=17-24Ft 2= 1=#122 DHP B=2 2= 1=#122 DHP S=Standard 1=FR LT PVC S=Standard 3= 2=Wld T304 SS C=3 3= 2=Wld T304 SS H=Heavy 2=FR TPE H=Heavy 4= 3=Smls T304 SS Etc. 4= 3=Smls T304 SS X=Extra Hvy 3=FR PE X=Extra Hvy 5=5/8 4=PFA Fluoropolymer 5=5/8 4=PFA Fluoropolymer 5=FR Urethane 6=3/4 5=FEP Fluoropolymer 6=3/4 5=FEP Fluoropolymer 7=7/8 6=Smls Low Carbon Steel 7=7/8 6=Smls Low Carbon Steel Tubing Thickness Standards 8=1 7=Smls T316 SS 8=1 7=Smls T316 SS 9=1 ¼ 8=Monel 0* 9=1 ¼ 8=Monel 0* A=1 ½ 9=Wld T316 AA A=1 ½ 9=Wld T316 AA M=4 mm A=Smls T316L SS M=4 mm A=Smls T316L SS N=6 mm B=Wld T304L SS N=6 mm B=Wld T304L SS P=8 mm C=Smls T 304L SS P=8 mm C=Smls T 304L SS Q=10 mm D=TFE Fluoropolymer Q=10 mm D=TFE Fluoropolymer R=12 mm E=Wld Low Carbon Steel R=12 mm E=Wld Low Carbon Steel F=Smls Inconel C22* F=Smls Inconel C22* G=Incoloy 825* G=Incoloy 825* H=Hastelloy C-22* J=Hastelloy C-276* K=Nickel 200 K=Nickel 200 L=Alloy 20 K=Nickel 200 M=Polypropylene L=Alloy 20 N=Low Density Poly P=High Density Poly Q=Thermoplastic Hose R=Customer Spld. Matl. S=Nylon T=FR Polyethylene U=Permbar Z=Other Material H=Hastelloy C-22* J=Hastelloy C-276* M=Polypropylene N=Low Density Poly P=High Density Poly Q=Thermoplastic Hose R=Customer Spld. Matl. S=Nylon T=FR Polyethylene U=Permbar & 3/4 Metal 1/8 3/4 Plastic NOTES: 1. Reference tubing and material selection are to determine appropriate derivations. 2. Twelve (12) digit part numbers are used only for products which require outer jacketing material other than our standard FR PVC or if material is required in 17-24 straight length rather than maximum coil length. 3. Jacketing material with FR = Flame Retardant. *Hastelloy is a trade name of Haynes International, Inc. *Monel, Inconel, and Incoloy are trade names of Inco Alloys International, Inc. Light.020.0 Length Std. Hvy X-Hvy.0.047.093.093.093 Form 2202/4LTSTM-0103 Copyright 2003 Dekoron/Unitherm. All rights reserved

DEKORON/UNITHERM Form 2202/4LTSTM-0103 Copyright 2003 Dekoron/Unitherm. All rights reserved

DEKORON/UNITHERM Form 2202/4LTSTM-0103 Copyright 2003 Dekoron/Unitherm. All rights reserved