CI/SfB (52.5) January 2004 Uniclass L L2123. ACO LightShaft Daylight and fresh air. Naturally.

Similar documents
Installation instructions. LORO-ATTIKASTAR siphonic drains

CI/SfB Oct 12 (52.5) Uniclass L7314

CI/SfB Oct 12 (52.5) Uniclass L7314

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

SECTION B. Product Data: Provide manufacturer's standard details and installation instructions.

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 protecting Membranes 90 System Components.

Installation Manual For Conical Tanks. INSTALLATION and MAINTENANCE INSTRUCTIONS FOR CONICAL TANKS

INSTALLATION INSTRUCTIONS B-407-RB SERIES SINGLEWALL RETROFIT TANK SUMP

Straight Panel Bath Screen Instruction Manual

Mounting systems for solar technology

Sikaflex 221 is a high-adhesion, polyurethane-based sealing compound for Low-odour

Planning and installation instructions

Drain DESIGN & INSTALLATION GUIDE 316L STAINLESS STEEL INDUSTRIAL FLOOR DRAINS & LINEAR DRAINAGE CHANNELS

O&M MANUAL STANDARD FLOWPLATE PART NO NMFP - 03

Conergy SolarFamulus II

FLAT. The system: it supports 3 load classes (A15, B125, C250) in compliance with Standard EN 1433

The system: it supports 3 load classes (A15, B125, C250) in compliance with Standard EN 1433

SPECIAL SPECIFICATION 5787 Manhole Rehabilitation

Uniclass L7315 CI/SfB (52.5) X EPIC J3413. Liberty-Drain. Copyright 2010 Peter Savage Limited. LDV2 - Sep 10

CYCLONE Steel gutters and rainwater system. A steel rainwater system designed to protect in the toughest weather

Install & Maintenance Instructions

Sliding Door Systems

Multi-Piece EasyStep Product Installation Instructions

STEP UP SHOWER BASE INSTALLATION GUIDE FOR TIMBER AND CONCRETE FLOORS

Bridge Drainage Systems

1850 x 40/50mm Raised Shower Tray Kit

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 7

SECTION RESILIENT SHEET FLOORING

FS-DUO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.2 cm)

INFO 1/2015. NEWS Outdoor drainage system Universal wall concealed trap New softclose toilet seat Colored toilet seats. INNOVATION New odour trap

PRODUCT INFORMATION Dero Hoop Rack

Freedom Barrier Free Shower Pan Installation Instructions

Freedom Barrier Free Shower Pan Installation Instructions

Multi-Piece EasyStep Product Installation Instructions

The syphonic roof drainage system

Bi-Folding Door Installation Guide

SV24. Submittal Special Precautions Specifications Installation. 12½" (31.8 cm) 12½" (31.8 cm) 12" (30.5 cm) 12" (30.5 cm) 12" (30.

Pittsburgh Corning Glass Block Shower System Mortar Installation Standard Fit Shower Instructions

B500-VRC / B600-VRC SERIES INSTRUCTIONS DETAILS RS-500-VRC INSTALLATION

DRAINS: & , S COMMERCIAL. Drains: Bath, Shower & Commercial

II TECHNICAL INSTALLATION GUIDE

F Ü R D I E ZU K U N FT G E DAC HT. Flat roof vents. Soil vent pipes Refurbishment vents Cold roof vents

Linear Drainage Z886. Perma-Trench. Installation Instructions. 100mm Clear Opening

Gas Protection System Components

Freedom One-Piece Barrier Free Showers Installation Instructions

Impression Graphic panels

Cornerview Shower Enclosure & Base

INSTALLATION MANUAL. B-710/760 H20 SERIES MODULAR UST to AST TRANSITION SUMP

H series. for upper balconies DN 100. DN 100 Vers. a X X. Partial unit Side drain

Technical Data Sheet NEC/GRAN/95:01

6032 SH 3P Residential Shower Installation Instructions Gelcoat & Solid Surface Bathware

Operating Instructions

DRAINAGE SOLUTIONS SINCE 1908 SURFACE DRAINAGE. Installation Guide ARMTEC.COM

Sealing products. The new Generation of sealing-products


Dynamic Bonding Systems B.V. A division of Dutch Bonding Group B.V.

Outline NBS Specification. Protec System to Felt (Waterproofing Only)

Pacific Polymers Elasto-Deck 5000X2 Guide Specification

Maelstrom. Installation and Specification Guide

C.R. LAURENCE CO., INC. Intelli-Track SPS. Phase One - Installation Instructions

WALK-IN SHOWER BASE INSTALLATION GUIDE FOR CONCRETE FLOORS

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.

Water Channeling System

Outward Folding Bathscreen Instruction Manual

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

2K UniSlope Kit. Wet Room Materials UK: 25 Town Street, Duffield, Belper, Derbyshire, DE56 4EH

T TABLE OF CONTENTS SPUNWRAP COLLAR

FLOOR DRAINS GENERAL INFORMATION

Technical Data Sheet

Pacific Polymers Elasto-Deck 5000MR Guide Specification

ACO SELF Euroline. Euroline Polymer concrete drainage channels. Euroline 100 Euroline 150

Important Information

PanelGrip Dry Glaze Glass Railing System

DRAINAGE CHANNEL PROFI. Drainage systems. unrivalled in durability resistant to corrosion galvanised, cast iron, stainless steel

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE

Curtain Wall Stick System (Capped)

US Pool Lift Model #114 (Independence) Installation Guide

LINEAR DRAINAGE. Z886 Perma-Trench. 6" Perma-Trench Installation Instructions

30mm Height Linear Drain Shower Trays

Exterior Wall Solutions Building Shell

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

adjustable fusion shower pan surface mounted on subfloor installation guide

Ubau Flo Shower Element Installation Manual

SRP-AirOutshield UV Issued:

Complete Modern Drainage System

SECTION 07530CP EPDM MEMBRANE ROOFING

Exterior System installation instructions

6x5. Assembly Manual CAUTION. Sharp Edges PATENTS ARE PENDING. Building Dimensions. Approximate Size. Storage Area. Interior Dimensions

Installation Manual. Foundations. Version 4.3ᵠ

ZS880 Linear Shower Drain Installation Instructions

CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT

HC-Omega (Sinus Slide ) armour joints

adjustable fusion shower pan on wood joists installation guide

SECTION RESILIENT SHEET FLOORING

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

Assembly and Installation Instructions Grease Separator KLsepa.pop

A. This section is intended to provide design guidelines for Utility Direct Buried Piping and Conduit Systems.

ACO Building Drainage

Shower and Floor Gullies SECTION

TECHSEAL POLYSULPHIDE SEALANT RDL 940 (Gun Grade) RDL 941 (Pour Grade)

Transcription:

CI/SfB (52.5) January 2004 Uniclass L7315 + L2123 ACO LightShaft Daylight and fresh air. Naturally.

OVERVIEW Why choose ACO LightShaft? Maximum daylight transmission thanks to bright white polypropylene body Allows natural airflow to basement Strong galvanized steel gratings, safe for pedestrians or car parking Watertight design eliminates damp problems Simple, rapid installation saves time and money Versatile thanks to wide range of accessories Strong Tough, tear-proof glass-fibre reinforced body Will not crack if distorted by excessive loading or abuse All versions suitable for pedestrian or vehicle traffic, depending on choice of grating Can be fitted to walls with exterior insulation The LightShaft System: The beauty of the ACO Allround LightShaft is in the detail: every model has a drain point and sealant groove around the mating surface with the basement wall, making watertight installation straight forward. For standard applications four wall anchors (supplied) hold the shaft securely, and each unit is supplied with full installation instructions. A choice of gratings are available; whether heavy load capacity or optimum light transmission is your priority. The accessories supplied with the LightShaft are tailored to each and every application to ensure the best fit and greatest strength. If appearances are important, clip-on stainless steel trims are also available, as well as safety glass raincovers. For externally tanked walls in areas with a high water table, an additional kit is available to ensure LightShaft sealing, as well as a choice of drainage options to deal with rainwater. Versatile Watertight, even in areas with a high water table Choice of four gratings Suitable for all wall types Suitable for bituminous or white tanked walls Drainage connection for watertight installations Secure Safety glass raincovers available for all installations Anti-vandal grating securing clips 2

ACO 400mm ALLROUND LIGHTSHAFT - SPECIFICATION Material The robust main body is manufactured from bright white glass-reinforced polypropylene, giving an ideal mix of elasticity, stability and watertightness, while maximising natural light transmission. Easy to specify All LightShaft bodies are supplied with the relevant grating and fitting kits to fulfil your requirements exactly. Easy to fit All LightShafts come with a set of assembly instructions and fitting kits. Please see pages 11-15 for installation details. Drilling locations for the four standard mounting points are clearly marked on the mounting face. Further blind mounting points for watertight installations are clearly marked. D W 100mm H Y LightShaft Window Width Grating Size H D W Y Pressurised Watertight Size (mm) (mm) (mm) (mm) (mm) (mm) Applications 800 x 600 x 400 800 840 x 400 666 429 920 809 Yes 1000 x 600 x 400 1000 1040 x 400 666 429 1120 1008 Yes 1000 x 1000 x 400 1000 1040 x 400 1073 429 1120 1008 Yes 1000 x 1300 x 400 1000 1040 x 400 1373 429 1120 1008 Yes 3

ACO 400mm ALLROUND LIGHTSHAFT - EXTENSION PIECES Extension pieces are available for both 800 and 1000mm wide LightShafts, and up to three may be used per LightShaft Safe for pedestrian passage No cutting necessary to fit extension pieces Extension pieces are not watertight or suitable for vehicle passage Fitting kit included No additional reinforcement pieces are required where only one extension piece is used. Where LightShafts are fitted with more than one extension piece, the first and second extension piece must be fitted with a reinforcement piece. Removable grating with anti-vandal securing clips Reinforcement pieces Backfilled soil, compacted in layers Homogenous backfill, ideally gravel and sand 150mm min. Optional drainage W D H Height Range (stepless adjustment) (mm) H D W Extension Piece 1 Ext. Piece 2 Ext. Piece 3 Ext. Piece (mm) (mm) (mm) 800 x 400 90-300 300-580 580-860 320 431 1040 1000 x 400 90-300 300-580 580-860 320 431 1240 4

ACO 400mm ALLROUND LIGHTSHAFT - ACCESSORIES Grating options Drainage Expanded mesh grating, pedestrian loadings up to 1.5kN Standard outlet, with foul air trap and standard 100mm pipe attachment Mesh grating, mesh size 30 x 30mm, pedestrian loadings up to 1.5kN Fitting Kits Mesh grating, mesh size 30 x 10mm, pedestrian loadings up to 1.5kN, vehicle wheel loadings up to 9.0kN A fitting kit for pedestrian-trafficked LightShafts is included in standard LightShaft assemblies. For thoroughfares or terraces the 30 x 10mm mesh grating is recommended. All LightShaft assemblies come equipped with a grating to match your requirements. Expanded mesh, 30mm x 30mm or 30mm x 10mm mesh are all available, the latter suitable for light vehicle passage. The grating anti-vandal attachments simply screw into pre-formed points in the LightShaft body, further speeding installation. Fitting kit for vehicle-trafficked LightShafts is included in LightShaft assemblies with vehicle - suitable 30/10mm gratings. 5 Fitting kit included with all extension pieces.

ACO 500 AND 600mm LIGHTSHAFT SPECIFICATION Large ACO LightShafts in detail ACO LightShaft is available for watertight installations in 1000 x 1300 x 500 and 1250 x 1200 x 600mm sizes. ACO LightShaft has been independently tested and certified for watertightness. Easy to fit Standard and pressurised watertight fitting instructions are similar to ACO Allround LightShafts. Please see Page 12. D W 100mm H Y LightShaft Window Width Grating Size H D W Y Pressurised Watertight Size (mm) (mm) (mm) (mm) (mm) (mm) Applications 800 x 800 x 500 800 910 x 505 850 530 970 870 No 1000 x 800 x 500 1000 1110 x 505 850 530 1170 1060 No 1000 x 1000 x 500 1000 1110 x 505 1050 530 1170 1060 No 1000 x 1300 x 500 1000 1110 x 505 1350 530 1170 1060 Yes 1250 x 1300 x 600 1250 1360 x 605 1350 630 1420 1320 Yes 6

ACO 500 AND 600mm LIGHTSHAFT - EXTENSION PIECES Extension pieces are available for both 800 and 1000mm wide LightShafts, and up to three may be used per LightShaft Safe for pedestrian passage Each extension piece must be fitted with a reinforcement piece The 1250 x 1300 x 600mm LightShaft should not be used with more than two extension pieces Extension pieces are not watertight or suitable for vehicle passage Removable grating with anti-vandal securing clips Reinforcement pieces Backfilled soil, compacted in layers Homogenous backfill, ideally gravel and sand 150mm min. Optional drainage W D H Height Range (stepless adjustment) (mm) H D W Extension Piece 1 Ext. Piece 2 Ext. Piece 3 Ext. Piece (mm) (mm) (mm) 800 x 500 90-300 300-580 580-860 320 550 1090 1000 x 500 90-300 300-580 580-860 320 550 1260 1250 x 600 90-300 300-580 N/A 320 650 1520 7

THE ACO 500 AND 600mm LIGHTSHAFT RANGE Making the most of natural light. Grating options Greater light transmission thanks to greater depth from wall High reflectivity thanks to smooth, bright white surface Larger version suitable for standard or pressurised watertight installations No flooding risk thanks to drainage outlet at lowest point Expanded mesh grating, pedestrian loadings up to 1.5kN Easily fitted to externally insulated walls Drainage Mesh grating, mesh size 30 x 30mm, pedestrian loadings up to 1.5kN Pressurised watertight drainage outlet. Mesh grating, mesh size 30 x 10mm, pedestrian loadings up to 1.5kN, vehicle wheel loadings up to 9.0kN 8 Standard outlet, with foul air trap and standard 100mm pipe attachment. For thoroughfares or terraces the 30 x 10mm mesh grating is recommended. All LightShaft assemblies come equipped with a grating to match your requirements. Expanded mesh, 30mm x 30mm or 30mm x 10mm mesh are all available, the latter suitable for light vehicle passage. The anti-vandal grating attachments simply screw into pre-formed points in the LightShaft body, further speeding installation.

ACCESSORIES - FOR ALL ACO LIGHTSHAFTS ACO LightShaft Raincovers ACO LightShafts raincovers are made from tempered safety glass and include a full fitting kit. The wall-facing edge has a flexible seal to ensure watertightness. Stainless Steel Trim The aesthetic appeal of the ACO LightShaft can be further enhanced with a stainless steel trim, available for all sizes of LightShaft. The simple clip on edging also protects the top edges from vehicle tyre marks. Protects against dirt, leaves and rain Ensures the LightShaft stays clean for maximum light transmission Does not reduce light transmission or airflow A grating must be fitted to raincoverequipped LightShafts for safety ACO LightShaft with clip-on stainless steel trim and 30 x 30mm mesh grating Speed up installation Drilling holes for each LightShaft size on the ACO Spirit Level body gives the best possible start to each installation. 9

10 ACO LightShaft INSTALLATION - NON-WATERTIGHT ACO LightShaft installation 5. Position the plugs, then install and for pedestrian and light tighten screws. vehicle traffic 1. Insert the grating into the LightShaft body and secure using the chain and clip assembly. Secure the grating 6. Backfill in layers fastener in the with excavated lateral slots when material and using an expanded compact down. metal grating, and in the mesh when using a mesh grating. 2. Mark the level of the upper edge of the light shaft at 7. Ensure heavy plant ground level. If is kept at a safe using the ACO distance from the Spirit Level, the LightShaft upper edge of the installation to assembly aid prevent damage. represents the upper edge of the LightShaft. The distance from the lower edge of the window to the base of the light shaft should be at least 150mm. Extension Piece Installation 3. Mark the 4 holes 1. First install against the wall. LightShaft main The upper holes will body. lie 60mm below the upper edge of the 2. Insert the light shaft. LightShaft grating into the extension piece. 3. Place the required 4. Drill out and clean number of fixing holes. extension pieces onto the LightShaft. 4. Drill out attachment holes. 5. Insert securing screws and tighten. 6. Backfill in layers with excavated material and compact down. 90-300mm installed height 7. Ensure heavy plant is kept at a distance from the LightShaft installation to prevent damage.

INSTALLATION - WATERTIGHT, WHITE WALLS Overview Thanks to its extremely strong design, regularly spaced securing points, robust polypropylene body and integral sealant groove, it is simple to have a watertight connection to externally tanked basement walls. In addition, a heavy-duty stainless steel clamping set is available to spread the bolting pressure across the entire facing edge of the LightShaft, making it essential for watertight installations. ACO also supplies Profix, the ideal sealant for this type of installation, guaranteeing the watertightness of your LightShaft installation. ACO Profix: Single-pack sealant This should be applied to the sealant groove in the LightShaft edges to give a watertight seal on externally tanked walls. Approximately 2 tubes will be required for an average LightShaft. Bitumen-sealed wall installations Where an ACO LightShaft is installed on an externally bituminous-sealed wall, a compatible sealing compound must be used, as ACO Profix is not suitable. For an installation to this kind of wall, please refer to the instructions on page 14. 11

INSTALLATION - WATERTIGHT, WHITE WALLS Preparation Tools required 17mm ring spanner Slot and Philips screwdrivers Pliers Tape measure ACO Spirit Level Hammer Drill with depth stop Masonry drill bits Hammer Sanding block Lint-free cloth Acetone or similar solvent Stiff brush Skeleton gun and ACO Profix Torque wrench and 17mm socket Preparation Conditions Ensure the outer wall surface is clean and dry Ensure all traces of grease or oil are removed from the LightShaft mating face Only install ACO LightShafts between +5 and +40 C to eliminate thermal stresses Ensure the LightShaft is located centrally in relation to the basement window Clean loose debris from the wall with a stiff brush Remove traces of oil with a steam cleaner or solvent If the wall surface is porous, apply an epoxy primer to the area where the LightShaft mating surface will touch Remove any loose pieces of wall surface, and repair defects or pitting with an epoxy repair kit and allow to cure. 12

INSTALLATION - WATERTIGHT, WHITE WALLS Procedure 1. Attach the grating to the LightShaft body using the clips and chains provided. 2. Mark the two upper securing holes of the light shaft at ground level. If using the ACO Spirit Level, the upper edge of the assembly aid represents the upper edge of the light shaft. The distance from the lower edge of the window to the base of the light shaft should be at least 150 mm. 3. Drill out the top two holes to a depth of 70mm. Take care not to drill further. 4. Blow out dust from holes. 5. Knock in the top two expanding anchor bolt. 6. Temporarily hang the LightShaft from the top two anchor bolts and mark out the other drilling points. Remove the LightShaft and drill out the marked holes to a depth of 70mm, as close to 90 to the wall as possible. Clean the holes out and knock in the expanding anchor bolts. Clean the wall with a stiff brush. 7. Key the mating surface of the LightShaft flange with a sanding block or wire brush. 8. Clean the mating surface of the LightShaft flange with a cloth and acetone or similar solvent. 9. Apply a thick bead of ACO Profix to the flange groove, ensuring it adheres cleanly. 10. Lower the LightShaft assembly onto the bottom right anchor bolt, and then press into the wall ensuring all bolts pass through the holes. Attach the two vertical clamping rails and hold in place by screwing the nuts down finger-tight. 11. Fit the two lower clamping rails and screw securing nuts on finger-tight. Then evenly tighten down all nuts so that the sealant is forced out of the joint. If possible, use a torque wrench and tighten to 30Nm (23 lb.ft.). 12. Leave the sealant to cure for 72 hours. ACO Profix cures on contact with oxygen and is accelerated by high humidity. If required, attach the drainage pipework to the water outlet. Backfill the pit around the LightShaft and compact down in stages. Auxiliary Clamping System (Optional) If bolting through preformed holes in the LightShaft body is not possible, due to weak masonry or to avoid cabling, you can use an auxiliary clamp up to 55mm from the original hole. Fill the failed hole with ACO Profix to prevent seepage, and drill a new hole alongside the LightShaft body to attach the auxiliary clamp, ideally at the same height. Ensure that bolts are used at every bolting point, whether through a fixing hole or alongside. NB: Extension pieces are not watertight, so where possible, use a taller LightShaft assembly. 13

INSTALLATION - WATERTIGHT BITUMINOUS WALLS Procedure Installation is similar to that for white walls, but with the following differences: 1. Ensure the black coating on the basement wall is sufficiently thick and in good order, and sufficiently flat. 2. Do not use ACO Profix for sealing the LightShaft body to the wall. Choose a sealant compatible with the wall coating and coat the mating surface of the LightShaft thickly. NB: When attaching ACO Allround 400mm LightShafts to externally-tanked bituminous walls, use fixing kit 35599. Drainage connection - black or white walls If using a drain in this application, use part number 00331, as this is fitted with a watertight seal to prevent leakage into the LightShaft from surrounding groundwater. This should be hand tightened (1Nm). If drainage is not necessary, two types of stainless steel stopper are available: 1. First-Fit stopper (35583), which can be fitted before or during installation. 2. Retrofit stopper (35665), suitable for fitting after installation or to replace an existing outlet. NB. Plugs or Drains for watertight installations must be tightened from the inside of the LightShaft to eliminate the risk of damage to the seal. 14

ACO VENTILATION SHAFTS The ACO Ventilation Shaft is ideal for rooms where constant airflow is required (e.g. washrooms with tumble dryers and heating boilers). Quick and easy to install Can be stacked to any height, with infinitely variable adjustment Available with expanded or welded mesh galvanised steel gratings Only 400 x 400 x 200mm in size Internal aperture is 170 x 337mm for maximum airflow Fits wall apertures up to 300mm - ideal for most domestic applications Expanded mesh grating 30 x 30mm mesh grating 30 x 10mm mesh grating Installation Before fitting, assemble and secure the Ventilation Shaft and grating together Position and mark the shaft upper edge against the wall Mark out securing points Drill out and clean holes Insert and screw shaft to wall Backfill excavated area with mixed material and compact Ensure heavy plant is kept away from the installation 600-700mm 700-780mm If two complete Ventilation Shafts are assembled vertically, a height range of 700-780mm is possible. If the two lower securing lugs are removed, the height range can be reduced to 600-700mm. Securing lugs Securing lugs 15