experienced. focused. evolving. just like you.

Similar documents
i n t e r v e n t i o n a l b r e a s t b i o p s y s o l u t i o n s The Right Biopsy Solution for every patient

Comprehensive Solutions

Breast Biopsy. Breast Tissue Markers. Cassi II. Beacon. Cassi Star Breast Tissue Marker with exceptional visualisation

MultiCare Platinum & StereoLoc II Prone and Upright Stereotactic Biopsy Solutions

in Ultrasound-guided breast biopsy

Quality ID #262: Image Confirmation of Successful Excision of Image-Localized Breast Lesion National Quality Strategy Domain: Patient Safety

Measure #262: Image Confirmation of Successful Excision of Image-Localized Breast Lesion National Quality Strategy Domain: Patient Safety

Automated Breast Volumes. Simplified.

3/6/2017 TOMOSYNTHESIS GUIDED BREAST BIOPSY LEARNING OBJECTIVES DISCLOSURES

BEYOND WIRES. Overcoming the Challenges of Breast Tumor Localization. Charles Cox, MD Pat Whitworth, MD Kate Maguire. Published by

Extending Ultrasound Capabilities. General Imaging

Urology Equipment & Accessories

Your surgical room. Simplified.

Leksell. Vantage Stereotactic System. Advancing stereotactic neurosurgery

HOLOGIC products available from ALKO Enterprises, Inc.

GE Healthcare LOGIQ 7

BodyFIX Maximize positional accuracy. Support delivery with precise patient positioning and immobilization

Occams Business Research & Consultancy

GE Healthcare. PET/CT + MR Trimodality Imaging

Uncompromised accuracy in neuroimaging and treatment

Accepted Manuscript. Tag, You re It! Finding and Treating Early Lung Cancers in a Single Setting. Ngoc-Quynh Chu, MD, Yolonda L.

Selenia Digital Breast Imaging Saving Time, Saving Lives.

CLEAR ANSWERS FROM PROSTATE

CASCINATION CAS-ONE SURGERY STEREOTACTIC NAVIGATION SYSTEM FOR ABDOMINAL SURGERY

The Next Revolution in Endoscopic Ultrasound Guided Biopsy Products

Setting The study setting was secondary care. The economic study was carried out in the USA.

Visualizing the invisible

SONOLINE G60 S A new perspective on multi-specialty ultrasound

Making the difference with Live Image Guidance

Ultrasound Fleet with Ease

Ultrasound guided biopsy using magnetic resonance volume navigation for the histological approach of additional breast lesions: a new technique

Connect and Deliver Optima CT580 RT

Scan. Smart. ACUSON NX2 Series. siemens.com/nx2

Advanced FEA Stress Analysis of Medical Instruments and Devices using Femap, NX Nastran and LS-DYNA

Built for strength and security.

Soft Tissue Puncture Model for Situation Awareness Percutaneous Robot

Resona 6. New Waves in Ultrasound Innovation. Premium Ultrasound System

Digital breast tomosynthesis-guided biopsy: preliminary experience

STEPS TO APPLY FOR A NOVEL CPT CODE

ultrasound your way Exceptional performance. Intuitive console. 3D/4D imaging. SonixSP 3D/4D ultrasound system

LAP-BAND System Access Port II Kit

Quantum Perfusion Systems

Smaller. Smarter. Simpler.

Creating the future of Healthcare through meaningful innovation. Gene Saragnese, CEO Healthcare Imaging Systems

Growth Strategy for Medical Systems Business

CARESTREAM DRX-Evolution SIMPLE. GENIUS.

Pulmonary Nodule Localization - Best Method. Jay M. Lee, M.D. Chief and Associate Professor Division of Thoracic Surgery, UCLA

Senographe. Crystal. Nova. Digital mammography transformation, simplified. gehealthcare.com

LOGIQ S8 with XDclear Simply Amazing

GE Healthcare. Vivid i Cardiovascular Ultrasound System. Call For More Information

Cardiac Rhythm Management // Patient Brochure // BioMonitor 2. BioMonitor 2. Patient Information

SONOLINE G20 Ultrasound System Performance that goes the distance

Own. The Day MENTOR. MemoryGel Xtra. Breast Implant

Novel Kidney Imaging. Objectives. Imaging surveillance in VHL. Disclosures. From nephrology perspective 10/11/2018

Vantage Titan 1.5T MR. The Intelligent Choice.

VA L U E A N A LY S I S B R I E F

Diamond Select. Brighten the way ahead

LOGIQ 5 TruScan Imaging Technology

Rockwell Automation Drive Systems. Solutions for the Mining Industry

Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration

The neov endovascular

TITLE: Fluorescence and Diffuse Reflectance Spectroscopy for Breast Cancer Diagnosis During Core Needle Biopsy

Scan. Smarter. ACUSON NX3 Series. siemens.com/nx3

GE Healthcare. GoldSeal. Refurbished imaging systems. Reliable quality. Certified confidence.

Harvesting a New Standard of Care

Investor Relations Hologic

Introducing a new take on efficient workflow: Deeply integrated clinical applications

Ultrasound. It understands your everyday. Philips Affiniti 30 ultrasound system for women s health care

Angio PL.U.S. PLaneWave UltraSensitive TM ultrasound imaging. White Paper

ViewPoint 6 Clarify your View

FRIENDS OF AMIGO. Advanced Multimodality Image Guided Operating Suite

Integrated Radiology & Pathology Diagnostic Services: The Time is Now at UCLA

Best Total Solutions for Breast Cancer Diagnosis & Treatment

Vacuum-Assisted Ultrasound excision of a breast lesion

RapidPort EZ Access Port Kit DIRECTIONS FOR USE (DFU)

CareCenter MD The first PC-based, wireless, diagnostic workstation

Unlimited potential at your fingertips

Dynamically Oscillated Biopsy Needle

A LASER PLATFORM. A REMARKABLE DESIGN.

Genentech, Inc., its research partners, collaborators, assignees, licensees or designees. Invitation to Participate

EVIS EXERA III. Advancing the Art of Bronchoscopy.

Biograph TruePoint PET CT. The World s First HD PET Platform.

Teleflex Incorporated (NYSE: TFX) Investor Presentation

TRACERcenter. One source. One complete solution. imagination at work. About GE Healthcare

Delivering top performance. Outstanding value. Diagnostic scalability. ACUSON X150 Ultrasound System.

The 2.9 mm Percuvance Percutaneous Surgical System. Less trauma. All the performance and versatility you need.

Delivering Top Performance. Outstanding Value. Exceptional Reliability. ACUSON X150 Ultrasound System. Answers for life.

SOLUTIONS Express Enterprise SP Enterprise XP Integral Breast Workspace. better images mean better results

INVALUABLE VERSATILITY. GO DIGITAL. YOUR WAY. DRX-Evolution

YOULASER MT. THE WOLRD S FIRST FRACTIONAL C02 AND GaAs 1540nm LASER FOR ANTI-AGING AND BEYOND

Premium Performance. Extraordinary Technology.

CP MEDICAL PERFORMANCE PLUS DISTRIBUTOR PROGRAM

The 2.9 mm Percuvance Percutaneous Surgical System Less trauma. All the performance and versatility you need.

Welch Allyn Connex. Electronic Vitals Documentation (EVD) System

Realize your full potential

Integration for the Most Demanding Surgical Environments

Ultrasound-Based Real-Time Monitoring of Intrafraction Prostate Motion a transperineal approach

Transcription:

experienced. focused. evolving. just like you.

CONTROL MODULE Together, we re changing the outcome Over the past 17 years, we ve partnered with clinicians to achieve some remarkable firsts in breast cancer care. + 1995: We introduced vacuum-assisted breast biopsy with the Mammotome Breast Biopsy System. For the first time, you could remove more tissue more quickly, with less blood accumulation. Biopsy confidence increased, and over time, upgrade and underestimation risks decreased. With one device, you improved patient outcomes. + 1997: We introduced MicroMARK clip, the first tissue marker breast biopsy product, enabling you to return to the precise site of lesion removal when additional biopsy was required. + 2000: We pioneered Sentinel Lymph Node (sln) biopsy with Neoprobe Corporation, releasing Neoprobe 1500. Less breast cancer patients had to undergo extensive lymph node surgery. Millions of women have experienced the benefits of vacuum-assisted biopsy including lower underestimation rates, less pain and better cosmesis. Our comprehensive portfolio of products offers a range of options that help you deliver better patient outcomes. The Mammotome Biopsy System is clinically the most well acclaimed vacuum-assisted breast biopsy device. The key clinical proof is the nearly 4 million patients who have undergone the procedure in the last 17 years and the 280 clinical articles that have been published on its efficacy.

CONTROL MODULE The point of everything we do goes way beyond the performance of our products. It s about what our products can provide help to reach the proper diagnosis and treatment for patients. Nearly 4 million women worldwide have had a stereotactic, ultrasound or mri-guided minimally invasive breast biopsy using the Mammotome Biopsy System. + The proven Mammotome Biopsy System + Upgradable (3 modalities) + Unparalleled clinical training

STEREOTACTIC Mammotome st was the first of the three Mammotome platforms, launching the legacy of confidence, accuracy and trust.

STEREOTACTIC + Multiple probes and accessories to ensure maximum access: + 8-gauge probe tip Bladed tip facilitates insertion through dense tissue; 1 gram of tissue in 4 cores; tissue architecture preserved; take a sample/see a sample + 11-gauge probe tip Facilitates stroke margin management + Variable aperture sleeve for superficial lesions and thinly compressed breasts + Easy access to deep lesions + Optimal access to chest wall lesions + Multiple probes and accessories to ensure maximum access I chose to use the 8-gauge Mammotome st because it is a fast and efficient tool for complete or partial removal of imaged evidence of the lesion. In addition, the size and integrity of the 8-gauge samples offer simple and immediate confirmation that I am sampling the correct area in question. +terri-ann gizienski, m.d. cm 1 2 3 cm 1 2 3 8g 8g ST Sample Size 310mg per core 6mm incision size 11g 11g ST Sample Size 116mg per core 4.6mm incision size

ULTRA SOUND Mammotome ex brings the efficiency and accuracy of the Mammotome System to the ultrasound suite. Watch in real-time as you remove tissue from the breast. 8g 8g EX Sample Size 250mg per core 6mm incision size Porcine mammary tissue shown in actual size 11g 11g EX Sample Size 83mg per core 4.6 mm incision size Footswitch and remote control options available

ULTRA SOUND With ultrasound-guided biopsy, the imaging is in real-time. You can see the aperture and watch as you sample the areas of concern. Mammotome ex provides diagnostic confidence, especially for lesions 1 centimeter or smaller. + Single insertion, multiple contiguous samples + Reduces procedure time: 63% reduced force to penetrate allows for controlled, rapid and precise positioning + Needle size options include 8-gauge and 11-gauge + Comfort fit with ergonomic contours for various hand positions + Simple introduction of tissue marker using special ports + High patient satisfaction: 99% of patients would tell other women about the procedure The 8-gauge Mammotome ex has allowed me to offer a treatment option to women with benign disease. Instead of open surgery, I use the 8-gauge to remove the lesion. The procedure is fast, easy and my patients are relieved to know that they don t have to go to surgery. + lydia hernandez, m.d. + Use Mammotome ex to manage benign disease: 25% of women want lesions removed even if they are benign + For indeterminate lesions, use Mammotome ex to reduce the risk of underestimation + For malignant lesions, use Mammotome ex to provide proper staging + + The sampling aperture is clearly seen here between the indicators prior to retracting the cutter Virtually no imaged evidence remains of the lesion and the procedure is almost complete The lesion is clearly smaller while the ring down effect indicates the position of the open aperture

MRI Imageable aperture For a patient population whose lives depend on it, Mammotome mr complements your existing Mammotome Biopsy System perfectly. Mammotome mr offers breast biopsy guidance by magnetic resonance imaging technology: + Two needle size options (8- or 11-gauge) to obtain large samples with a single insertion + Two probe lengths (145 or 115mm) for maximum access to the breast + Marker placement independent of probe; marker is visible under sterotactic, ultrasound, and mri Now the mri-guided Mammotome mr is available for your patients who need additional evaluation most those who have had breast cancer before or have a family history of cancer, and patients with surgical implants or dense breast tissue. + Imageable aperture offers visual confirmation of lesion to aperture + Hands-free probe and holster minimize risk of movement after targeting + Three-dimensional Cartesian targeting + Pillar and post for controlling angulation + Mounted/detachable targeting set + Z-screw/Z-top accuracy + Open window access to the breast + Easy-to-read feedback window provides real-time feedback of cutter position and mode indicator + + Stereotactic post-fire image Mammotome mr confirmation image Mounted/detachable targeting set

MRI With a Mammotome mr-guided biopsy, the picture is clear. You can see the aperture, so you know you re in position. Hands-free probe and holster Z-Screw and Z-Stop enable you to make fine adjustments (as little as 2 mm) and to lock in your position on the rail

BREAST BIOPSY SYSTEM Leading the category with you As the world-wide leader in vacuum-assisted breast biopsy and tissue marking, Mammotome is committed to advancing technology for early detection of breast cancer. With world-class training, education, and customer support around the globe, Mammotome will keep you on the forefront of patient care. Order Placement Simply choose the option that works best for you. + Phone: Contact your Mammotome Customer Service Representative at 1-877-9-A-MAMMO between the hours of 8:30am and 6:30pm est. Shipping details and an order confirmation number will be provided to you upon completion of your order. + Fax: Send your order via fax to your Mammotome Customer Service Representative at 1-888-260-6362. + Email: Send your order via email to your Mammotome Customer Service Representative at customerservice@mammotome.com.

2012 Devicor Medical Products, Inc. All rights reserved. For complete product details, see Instructions for Use. MDM 12-0016.