Part 5 Substructure and ground floors. Chapter 5.2. Suspended ground floors

Similar documents
PAGE 415. Part 9. External works. 9.1 Garages. 9.2 Drives, paths and landscaping

9 Revision B

Xtratherm Thin-R Underfloor Board (XT/UF Grade)

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor 70, 100, 150, 200, 250

Polyfoam Floorboard For thermal insulation of floors

Part 8 Services and internal finishing. Chapter 8.3. Floor finishes

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor Premium 70 and 100

Jabfloor is also available in higher grades up to Jabfloor 250 which may be required in certain specialist industrial and commercial applications.

Detail Sheet 1 / Ballytherm BTF Floor Insulation

Jabfloor High Performance (HP) 70 and 100

Jabfloor 70 Floor insulation Suspended timber floor

Jabfloor 70, 100, 150, 200, 250

Jabfloor 70, 100, 150, 200, 250

PRODUCT SHEET 1 KINGSPAN KOOLTHERM K3 FLOORBOARD

JABLITE FLOOR INSULATION JABFLOOR 70

Agrément Certificate 12/4956 website: Product Sheet 6

OS Thermal System Installation Guide

Agrément Certificate / 07/4427 website: /

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES

Agrément Certificate 17/5405 website: Product Sheet 2 CELOTEX INSULATION

April Section 4.1. Ground Floors

RACKHAM FLOOR SYSTEMS POLY-PLUS F/T AND POLY-PLUS F/T EXTRA FLOOR SYSTEMS

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

Introduction. There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet.

Metal Web Floor System

Suspended timber upper floors

Agrément Certificate 15/5283 website: Product Sheet 1

FOAMSEAL FOAMSEAL RANGE OF INSULATION FOR FLOORS

SUNDOLITT EPS FLOORING INSULATION Isolation en polystyrène pour planchers en béton Wärmedämmung aus Polystyrol für Betonfußboden.

Jabfloor 70, 100, 150, 200, 250

Dow Building Solutions. Insulating floors with STYROFOAM Solutions: basic principles

Dow Building Solutions Insulating floors with STYROFOAM Solutions: basic principles

June Residential Refurbishment Basements

August 2008: Issue 1. Non - Residential New Build 4.5 Basements

September Reflex Bearers

Agrément Certificate 89/2196 website: Product Sheet 1

Dwelling-houses and flats performance standards for separating walls, separating floors and stairs that have a separating function.

JABLITE FLOOR INSULATION JABLITE FLOOR INSULATION 100 and 150

June Non - Residential Refurbishment Separating floors

Part 6 Superstructure (excluding roofs) Chapter 6.5. Steelwork

CELOTEX INSULATION CELOTEX RANGE OF PIR INSULATION BOARDS FOR FLOOR INSULATION

PIR Insulation. XT/UF Insulation for Ground Supported and Suspended Floors. Floors 08/ /0183

SPRINGVALE BEAMSHIELD PLUS AND PLATINUM BEAMSHIELD PLUS SYSTEM Système de solives et dalles porteuses pour planchers Bodenbalken.

Superior Performance Phenolic Insulation SR/UF. Insulation for Ground Supported and Suspended Floors. Floors AS LOW AS 10/4803

Housing Easy Guide: Beam and Block Ground Floors

Floors Walls Roofs. Jabfloor Premium board Jablite Premium board Jabfloor board Jablite board. APPLICATION: Basements PRODUCTS: Vencel Resil Limited

June Residential Refurbishment Separating floors

Part 6 Superstructure (excluding roofs) Chapter 6.2. External timber framed walls

TECHNICAL DATA SHEET CIVILS & INFRASTRUCTURE CLAY HEAVE PROTECTION

Refurbishment site guidance for solid-walled houses ground floors

robustdetails E-FC-7 Separating Floor Concrete Separating Floors Concrete E-FC-7

OLDROYD MEMBRANE SYSTEMS OLDROYD XS

VISQUEEN RADON MEMBRANE SYSTEM

APPLICATION: Floor insulation below chipboard finish

BISON PRECAST FLOORING SPECIFICATION

JABLITE JABFLOOR BOARDS JABFLOOR PREMIUM 70 AND 100

Civil Engineering Construction Chapter 5

Jabfloor High Performance (HP) 70 and 100

June Non - Residential Refurbishment 5.5 Basements

Bison Precast Flooring Specification

Stylite. T-Beam Suspended Floor Insulation Technical Datasheet. Stylite T-Beam Floor Insulation

Garage Conversion - Between and Under Joist Applications

Basement Board High Performance (HP) 70 and 100

BEAM & BLOCK SYSTEM. 108mm. 175mm Deep (160mm) Wide Beam. 160mm

CLAYMASTER COMPRESSIBLE FILL CLAYMASTER COMPRESSIBLE FILL LOW DENSITY EXPANDED POLYSTYRENE BOARDS

Contents. Technical Manual TS Page 1 of 98

Acoustray perimeter cavity stops

CORDEK VENTILATION VOID FORMERS VENTFORM PANELS

robustdetails E-FC-6 Separating Floor Concrete Separating Floors Concrete E-FC-6 SYSTEM INSTALLATION

EUROTHANE GP. Date of Second issue: 17 October 2013 John Albon Head of Approvals Claire Curtis-Thomas

Stylite. T-Beam Suspended Floor Insulation Technical Datasheet. Stylite T-Beam Floor Insulation.

STYRENE FLOOR SYSTEMS STYLITE T BEAM AND STYLITE T BEAM PLUS FLOORING SYSTEMS

Section 02 SUBSTRUCTURE

S AND B EXPANDED POLYSTYRENE INSULATION S AND B EPS FLOORING INSULATION

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

155 & 220 Beam Flooring Systems

Jabfloor 70, 100, 150, 200, 250

Visqueen Gas Barrier STRUCTURAL WATERPROOFING AND GAS PROTECTION SYSTEMS. CE Mark to EN 13967

April Section 4.3. Separating Floors

CHAPTER 11: External Works

Selecting floors and ceilings

Kingspan Aerofloor Floor Insulation System

April Section 5. Basements

KINGSPAN THERMAFLOOR TF73 Isolation en polystyrène pour planchers en béton Wärmedämmung aus Polystyrol für Betonfußboden

APPROVALS. Jabwall has been approved for this application since 1979, and was the first partial-fill insulation product to gain BBA approval.

Introduction. Contents

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

roofing ROOFING Design of the base ROOFING DETAILS

4.1 Ground Floors. Ground floors. Ground floor design. Technical Support Team

The Passive Fire Protection Handbook

Visqueen High Performance Radon Membrane

S AND B EXPANDED POLYSTYRENE INSULATIONS S AND B EPS FLOORING INSULATION

Introduction to timber frame construction

Jablite Board 250, 300, 350, 400 and 500

BDA Agrément BAF /01/A

ROGER BULLIVANT LIMITED SYSTEMFIRST HOUSE FOUNDATION SYSTEM

SOLCO MEMBRANES SOLSHIELD GAS MEMBRANE

Transcription:

Part 5 Substructure and ground floors Chapter

CONTENTS SCOPE Clause Page DESIGN - General Design standards D1 1 Statutory and other requirements D2 1 Resistance to ground contaminants D3-D4 1 This Chapter gives guidance on meeting the Technical Requirements and recommendations for suspended ground floors of in-situ and precast concrete and timber joists. DESIGN - In-situ concrete Structural stability D5 1 Resistance to moisture D6 1 Thermal insulation D7 1 Floor finishes and decking D8 1 DESIGN - Precast concrete Structural stability D9 1 Resistance to moisture D10 2 Thermal insulation D11 2 Floor finishes and decking D12 2 DESIGN - Timber Structural stability D13 2 Structural timber D14 2 Trimmers D15 2 Strutting D16 2 Joist hangers D17-D18 2 Joist support at separating walls D19 2 Intermediate support D20 2 Floor decking D21 3 Damp-proofing D22 3 Thermal insulation D23 3 DESIGN - Information Provision of information D24-D25 3 MATERIALS Materials standards M1 3 Concrete and reinforcement M2 4 Proprietary systems M3 4 Timber M4 4 Damp-proofing and thermal insulation materials M5 4 SITEWORK Sitework standards S1 4 Ventilation and damp-proofing S2-S3 4 Construction of floors S4 4 Thermal insulation S5 4 Floor finishes S6 4 Floor decking : general S7-S8 5 Softwood boarding S9 5 Chipboard flooring S10 5 Oriented strand board flooring S11 5 Other floor decking S12-S13 5 INDEX 5 Page 2 Chapter

DESIGN STANDARDS - D1 Design shall meet the Technical Requirements Design that follows the guidance below will be acceptable for suspended ground floors. STATUTORY AND OTHER REQUIREMENTS - D2 Design of suspended ground floors shall comply with all relevant statutory and other requirements Design should be in accordance with relevant Building Regulations and other statutory requirements. NHBC requires ground floors to be constructed as suspended floors in the following situations: where the depth of fill exceeds 600mm, as described in Chapter 5.1 Substructure and ground bearing floors (Design) where soil swelling may occur, as described in Chapter 4.2 Building near trees on sites which have been subject to vibratory ground improvement, as described in Chapter 4.6 Vibratory ground improvement techniques where ground or fill is not suitable to support ground bearing slabs. For suitable fill providing temporary support to suspended floors, refer to Chapter 5.1 Substructure and ground bearing floors Appendix 5.1-A. RESISTANCE TO GROUND CONTAMINANTS - D3 Design shall ensure that adequate measures are taken against adverse effects of ground contaminants and radioactive materials Any contaminants in or above the ground should be identified to the satisfaction of NHBC, following the guidance given in the appropriate British Standard. Where necessary, precautions against danger to health caused by contaminants should be taken, as described in the Appendix Introduction to remedial measures to Approved Document C1/2/3 and other Building Regulation documents. - D4 Design shall provide adequate protection against radon gas In certain parts of the country, special precautions may be necessary to reduce the entry of radon gas. Areas in England and Wales where special precautions are necessary are detailed in BRE Report 211. When precautions are necessary, they should be acceptable to NHBC. In-situ concrete STRUCTURAL STABILITY - D5 In-situ concrete suspended ground floors shall be designed to transmit all loads safely to the supporting structure without undue movement (a) dead and imposed loads Loads should be calculated in accordance with BS EN 1991-1-1. Suspended in-situ concrete ground floors should be designed either: by an Engineer in accordance with Technical Requirement R5, or in accordance with BS 8103 Part 4. (b) end bearings Bearings on supporting walls should be designed either: by an Engineer in accordance with Technical Requirement R5, or in accordance with BS 8103 Part 4. RESISTANCE TO MOISTURE - D6 In-situ concrete suspended ground floors shall be designed to resist the passage of moisture to the inside of the building (a) damp-proofing Dampness from the ground and supporting structure should be prevented from reaching the floor by use of dpms and dpcs. (b) linking dpm with dpc Damp-proofing of suspended ground floors should be linked with any damp-proofing of the supporting structure in order to provide continuous protection. Where there is a risk of sulfate attack, a polyethylene sheet dpm, not less than 1200 gauge (0.3mm) (or 1000 gauge (0.25mm) if assessed in accordance with Technical Requirement R3) should be used, properly lapped. - D7 Thermal insulation of in-situ concrete suspended ground floors shall be designed to comply with statutory requirements (a) insulation placed below the floor slab Insulation below the ground floor slab should: be placed on a suitable compacted and even substrate have low water absorption be resistant to ground contaminants be strong enough to support wet construction loads be compatible with any dpm. Suitable insulating materials are described in the Materials section. (b) insulation placed above the floor slab For guidance on insulation above the floor slab, reference should be made to Chapter 8.3 Floor finishes (Design and Materials). (c) cold bridging The design should ensure that any risk of cold bridging is minimised, giving particular attention to junctions between floor and external walls. Precautions include: extending cavity insulation below floor slab level linking floor and wall insulation providing perimeter insulation to floors facing the supporting substructure with insulation. FLOOR FINISHES AND DECKING - D8 Finishes and decking to in-situ concrete suspended ground floors shall be suitable for their intended use Details of finishes and decking are given in Chapter 8.3 Floor finishes (each section) and Chapter 6.4 Timber and concrete upper floors. Precast concrete STRUCTURAL STABILITY - D9 Precast concrete suspended ground floors shall be designed to transmit all loads safely to the supporting structure without undue movement (a) dead and imposed loads Loads should be calculated in accordance with BS EN 1991-1-1 Precast concrete suspended ground floors should be: designed by an Engineer in accordance with Technical Requirement R5, or proprietary systems which have been assessed in accordance with Technical Requirement R3, or chosen from manufacturers details which are based on recognised Standards and Codes of Practice. (b) end bearings Bearings on supporting walls should be as recommended by the manufacturer, and in no case less than 90mm. Chapter Page 1

RESISTANCE TO MOISTURE STRUCTURAL TIMBER - D10 Precast concrete suspended ground floors shall be designed to resist the passage of moisture to the inside of the building (a) damp-proofing The supporting structure should, wherever necessary, incorporate adequate dampproofing measures to prevent dampness from reaching the floor as described in the following Chapters: 5.1 Substructure and ground bearing floors (each section) 6.1 External masonry walls (each section). (b) ventilation of underfloor voids A minimum void of not less than 150mm should be provided below the underside of floor slabs and beams. On shrinkable soil where heave could take place, allowance should be made for the void to accommodate the following movements according to the shrinkage potential of the soil: high potential - 150mm medium potential - 100mm low potential - 50mm. Voids should be ventilated by openings providing not less than 1500mm 2 per metre run of external wall or 500mm 2 per m 2 of floor area, whichever gives the greater opening area. Ventilation openings should be provided on at least two opposite sides. Where this is not possible, effective cross ventilation from opposite sides should be provided by a combination of openings and air ducts. Where the finished level below the floor is lower than the finished adjoining ground level, appropriate drainage should be provided. (c) damp-proofing of suspended floors It may not be necessary to provide additional damp-proofing where the: underfloor void is ventilated and dpcs are provided under bearings of precast floors in accordance with CP 102 ground below the floor is effectively drained (if excavated below the level of the surrounding ground). Vapour control layers may be necessary to protect floor finishes and should be positioned in accordance with the manufacturer s recommendations (reference should be made to Chapter 8.3 Floor finishes (each section)). - D11 Thermal insulation of precast concrete suspended ground floors shall be designed to comply with statutory requirements (a) insulation above floor slab For guidance on insulation above a floor slab, reference should be made to Chapter 8.3 Floor finishes (each section). (b) cold bridging The design should ensure that any risk of cold bridging is minimised, giving particular attention to junctions between floor and external walls. Precautions include: extending cavity insulation below floor slab level linking floor and wall insulation providing perimeter insulation to floors facing the supporting structure with insulation. FLOOR FINISHES AND DECKING - D12 Finishes and decking to precast concrete suspended ground floors shall be suitable for their intended use Details of finishes and decking are given in floors and Chapter 8.3 Floor finishes (each section). Timber STRUCTURAL STABILITY - D13 Timber suspended ground floors, including the decking material, shall be designed to: (a) support self weight, dead loads and imposed loads (b) transmit loads safely to the supporting structure (c) not deflect unduly (d) take account of the adverse effects of shrinkage and movement floors (Design). - D14 Structural timber grades and sizes shall be adequate for the spans and imposed loads floors (Design and Materials). TRIMMERS - D15 Where trimming is necessary, adequately sized timbers shall be used STRUTTING - D16 Strutting shall be adequate to limit the twisting of joists JOIST HANGERS - D17 Joist hangers shall be suitable for the joist width and depth, the strength of masonry and the required load - D18 Adequate end bearings shall be provided for joists and joist hangers JOIST SUPPORT AT SEPARATING WALLS - D19 Joists shall be correctly supported at masonry separating walls INTERMEDIATE SUPPORT - D20 Sleeper walls shall adequately support the floor joists For guidance, reference should be made to Chapter 4.4 Strip and trench fill foundations (Design and Sitework). (d) linking dpm with dpc Where provided, damp-proofing of suspended ground floors should be linked with any damp-proofing of the supporting structure in order to provide continuous protection. Page 2 Chapter

FLOOR DECKING - D21 Appropriate materials for floor decking shall be used (a) decking and joist centres (b) resistance to moisture (c) fixing DAMP-PROOFING - D22 Design of timber suspended ground floors shall ensure that the floors are not adversely affected by moisture (a) damp-proofing of supporting structure The supporting structure should include damp-proofing to prevent moisture penetrating to the suspended floor, as described in Chapter 6.1 External masonry walls (each section). Where the finished level below the floor is lower than the finished adjoining ground level: appropriate drainage should be provided, or the structure should be tanked. (b) resistance to ground moisture Provision should be made to prevent ground moisture affecting timber floor construction. This can be achieved by either: 50mm concrete or 50mm fine aggregate on a polyethylene membrane laid on 50mm sand blinding, or 100mm concrete. In Scotland, the deemed-to-satisfy specification of the statutory regulations should be followed. Where necessary, oversite concrete should be protected against sulfate attack by the use of a polyethylene sheet dpm, not less than 1200 gauge (0.3mm) (or 1000 gauge (0.25mm) if assessed in accordance with Technical Requirement R3) properly lapped. (c) ventilation of underfloor voids A minimum ventilation void of 150mm should be provided below floor joists or 75mm below any wall plate. On shrinkable soil where heave could take place, an allowance for movement should be added to the underfloor ventilation requirement to determine the minimum dimension of the underfloor void. The allowance for movement relates to the shrinkage potential of the soil as follows: high potential - 150mm medium potential - 100mm low potential - 50mm. Voids should be ventilated by openings providing not less than 1500mm 2 per metre run of external wall or 500mm 2 per m 2 of floor area, whichever gives the greater opening area. Ventilators should be spaced at not more than 2m centres and within 450mm of each end of any wall. Air bricks should be ducted through cavities and be unobstructed. Every part of the void under a timber suspended ground floor should be thoroughly ventilated through openings on at least two opposite sides. Where this is not possible, effective cross ventilation from opposite sides should be provided by a combination of openings and air ducts. Provision should be made for ventilation through partitions and sleeper walls. If necessary, pipe ducts should be incorporated in adjoining solid floors, separating walls or other obstructions. Ventilation should not be obtained through a garage. - D23 Thermal insulation of timber suspended ground floors shall be designed to comply with statutory requirements (a) positioning of insulation Insulation may be: insulation quilt, or rigid insulation. Insulation quilt should be supported between joists. Rigid insulation boards should be adequately supported on battens fixed to the sides of joists. (b) cold bridging The design should ensure that any risk of cold bridging is minimised, giving particular attention to junctions between floor and external walls. Precautions include: extending cavity insulation below floor level linking floor and wall insulation providing perimeter insulation to floors facing the supporting substructure with insulation. Information PROVISION OF INFORMATION - D24 Designs and specifications shall be produced in a clearly understandable format and include all relevant information Clear and fully detailed drawings should be available on site to enable work to be carried out in accordance with the design. Design drawings should include: all necessary plan dimensions and levels related to identified benchmarks details of loadbearing walls minimum bearing dimensions information on all proposed underground services points of entry to the building for services penetration of services through the substructure, including support of the structure above details of trench backfill, infill and void formers the required sequence of trench backfill if this is relevant to the design of the walls below dpc work required to maintain the integrity of dpcs and dpms details of junctions between dpm, dpc and tanking details of underfloor and floor edge insulation and cavity insulation, where relevant. - D25 All relevant information shall be distributed to appropriate personnel Ensure that design and specification information is issued to site supervisors and relevant specialist subcontractors and/ or suppliers. MATERIALS STANDARDS - M1 All materials shall: (a) meet the Technical Requirements (b) take account of the design Materials that comply with the design and the guidance below will be acceptable for suspended ground floors. Materials for suspended ground floors should comply with all relevant standards, including those listed below. Where no standard exists, Technical Requirement R3 applies (see Chapter 1.1 Introduction to the Standards and Technical Requirements ). References to British Standards and Codes of Practice include those made under the Construction Products Directive (89/106/ EEC) and, in particular, appropriate European Technical Specifications approved by a European Committee for Standardisation (CEN). Chapter Page 3

CONCRETE AND REINFORCEMENT - M2 Concrete shall have appropriate reinforcement and be of a mix design that will: (a) achieve sufficient strength to support floor loads safely (b) be sufficiently durable to remain unaffected by chemical or frost action For guidance on the specification and use of in-situ concrete, additives and reinforcement, reference should be made to Chapter 2.1 Concrete and its reinforcement (each section). PROPRIETARY SYSTEMS - M3 Proprietary flooring systems shall have adequate strength and durability Proprietary concrete flooring systems should be designed in accordance with BS EN 1992-1-1. Where a system incorporates elements which cannot be designed to this standard, eg polystyrene infill blocks, the floor should be assessed in accordance with Technical Requirement R3. TIMBER - M4 Structural timber, decking and related materials shall be suitable for their location and intended use Materials should be selected in accordance with the relevant parts of Chapter 6.4 Timber and concrete upper floors (Design and Materials). DAMP-PROOFING AND MATERIALS - M5 Materials shall be suitable for their location and intended use (a) damp-proofing materials Damp-proofing materials should be selected in accordance with Chapter 5.1 Substructure and ground bearing floors (Design and Materials). For thermal insulation used above concrete floor slabs, materials should be selected in accordance with Chapter 8.3 Floor finishes (Design and Materials). SITEWORK STANDARDS - S1 All sitework shall: (a) meet the Technical Requirements (b) take account of the design (c) follow established good practice and workmanship Sitework that complies with the design and the guidance below will be acceptable for suspended ground floors. VENTILATION AND DAMP- PROOFING - S2 Construction of suspended ground floors shall ensure adequate damp-proofing Masonry supporting suspended ground floors should have been damp-proofed using dpm, dpc or tanking in accordance with the guidance given in the following Chapters: 5.1 Substructure and ground bearing floors (each section) 6.1 External masonry walls (each section). Where proprietary floor systems are used, moisture-resistant membranes, etc should be installed in accordance with the manufacturer s recommendations. - S3 Construction of suspended ground floors shall ensure adequate ventilation Ventilation should be provided in accordance with the design. This is normally provided by ventilators on at least two opposite external walls. Air bricks in cavity walls should be properly ducted as detailed in Chapter 6.1 External masonry walls (Design and Sitework). Sleeper walls should be constructed with sufficient openings to ensure adequate through ventilation. Where underfloor voids adjoin ground bearing floors, ventilation ducts should be installed. Ventilation should not be obtained through a garage. the design relevant parts of Chapter 2.1 Concrete and its reinforcement (each section) relevant parts of Chapter 6.4 Timber and concrete upper floors (each section). (b) precast concrete floors All sitework for precast concrete floors should be carried out in accordance with the manufacturer s recommendations. Care should be taken to ensure that dpcs are not damaged or displaced. (c) timber floors All sitework for timber floors should be carried out in accordance with the relevant parts of Chapter 6.4 Timber and concrete upper floors (Sitework). - S5 Thermal insulation shall be installed to minimise thermal transmission through the floor (a) floor insulation methods TIMBER FLOORS Insulation quilts should be supported, eg by draping plastic mesh across the joists and stapling it to joist sides so that the quilt can be laid to the full thickness. Insulation draped over the joists is not acceptable. mesh supporting insulation quilt Rigid insulation boards should be supported on battens or fillets nailed to the sides of joists. CONCRETE FLOORS For guidance on insulating concrete floors, reference should be made to Chapter 8.3 Floor finishes (each section). (b) thermal insulation materials Thermal insulating materials used below cast in-situ suspended floor slabs should be selected in accordance with the relevant recommendations given in Chapter 5.1 Substructure and ground bearing floors (each section). Thermal insulating materials for use with timber floors should be: expanded polystyrene boards (grade EPS 70) to BS EN 13163 mineral wool to BS 5803 : Part 1 other materials which have been assessed in accordance with Technical Requirement R3. CONSTRUCTION OF FLOORS - S4 Construction of suspended floors shall ensure that they safely support the intended loads and are reasonably level (a) in-situ concrete floors Concreting should be carried out in accordance with: (b) cold bridging The design should be followed to ensure that any risk of cold bridging is minimised. Pay particular attention to junctions between floor and external walls. FLOOR FINISHES - S6 Finishes to concrete suspended ground floors shall be protected, where necessary, against damp, condensation or spillage For guidance, reference should be made to Chapter 8.3 Floor finishes (Design and Sitework). Page 4 Chapter

FLOOR DECKING : GENERAL INDEX - S7 Flooring shall be fixed only when the dwelling is substantially weathertight floors (Sitework). - S8 Completed floor decking shall not be overloaded and shall be protected against damage floors (Sitework). Care should be taken to prevent trapping any water spillage below timber floors. SOFTWOOD BOARDING - S9 Softwood boarding shall be securely fixed CHIPBOARD FLOORING - S10 Chipboard flooring shall be of the type and thickness specified and shall be fixed securely ORIENTED STRAND BOARD FLOORING B Bearings 1, 2 Boarding 5 C Chipboard flooring 5 Cold bridging 1, 2, 3, 4 Concrete 4 Concrete floors 4 D Damp-proofing 1, 2, 3, 4 Decking 1, 2, 5 E End bearings 1 F Floor decking 3, 5 Floor finishes 1, 2, 4 Floor slab 1, 2 G Ground contaminants 1 I Insitu concrete 1, 4 Insulation 1, 2, 3, 4 Intermediate support 2 J Joist hangers 2 L Loads 1 O Oriented strand board 5 P Plywood 5 Precast concrete 1, 4 Proprietary systems 4 Protection 4 Provision of information 3 R Radon gas 1 Reinforcement 4 Resistance to moisture 1, 2 S Separating walls 2 Sleeper walls 2 Softwood boarding 5 Structural stability 2 Strutting 2 T Thermal insulation 1, 2, 3, 4 Timber 2, 4 Timber floors 4 Trimmers 2 U Underfloor voids 2, 3 V Ventilation 2, 3, 4 Voids 2, 3 - S11 Oriented strand board flooring shall be of the type and thickness specified and shall be fixed securely OTHER FLOOR DECKING - S12 Plywood decking shall be fixed securely - S13 Proprietary materials shall be fixed in accordance with manufacturers recommendations Other floor decking should have been assessed in accordance with Technical Requirement R3 and should be installed in accordance with manufacturers recommendations. Chapter Page 5