MECHANICAL RETROFIT OF HISTORIC WAREHOUSE TO NEW MEDICAL CLINIC IN TULSA, OK TEAM APRIL 10, 2010 JEFFREY DOWGALA LIAM HENDRICKEN LAUREN MCNALLY

Similar documents
BUILDING INTEGRATION

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

IECC 2006 with Hawaii Amendments

The baseline building system for compliance with Senate Bill 668 is defined by Appendix G,

Grunenwald Science and Technology Building

ENERGY CONSERVATION STRATEGIES FOR HVAC SYSTEMS

Environmental Stewardship Conference October 05, 2013 Energy Water and Sustainability (EWaS) Program

Georgetown University New Science Center

ENERGY AND ENVIRONMENT DESIGN AND CONSTRUCTION STANDARDS ENERGY AND ENVIRONMENT

IECC 2006 with Hawaii Amendments

AE 481W Thesis Proposal

Sonoma County Energy Independence Program APPENDIX A ELIGIBLE IMPROVEMENTS

Italcementi Center for Research and Innovation

City of Des Moines. Permit and Development Center 602 Robert D Ray Drive Des Moines, IA Phone: Fax:

VOLUME 4 DIVISION SPECIFICATIONS

Broad Institute Expansion: Cambridge, Massachusetts. Mechanical Thesis Proposal

780 CMR: 9 th Edition Massachusetts State Building Code. Presented to: BSA Codes Committee. DATE: January 20, 2016

43% reduction in water use below code maximum 100% 100% 14% reduction in lighting power density. 56% of offices have thermal comfort controls 100%

COMcheck Software Version Envelope Compliance Certificate

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)

IN THIS ISSUE INTRODUCTION BACKGROUND. March 2018 High Humidity in Winter: Analysis for Multi-Family Passive House Projects

CONSTRUCTION DOCUMENTS NECESSARY FOR PLAN REVIEW

Colorado Mountain College: Sustainable Design Standards

Green Buildings Make Cents

AN INNOVATIVE DEDICATED OUTDOOR AIR APPLICATION FOR A GOVERNMENT OFFICE TOWER. MICHAEL HALLENBECK, PE, CEM Southland Industries

CLARK BROCKMAN, SERA ARCHITECTS

Energy Efficiency, GeoExchange Systems and Renewable Energy MiAPPA Winter 2010

University of Illinois Business Instructional Facility LEED Gold Design. University of Illinois. University of Illinois

Capitalaire. Adapt Today to Shape Tomorrow. National Capital Chapter Capitalaire. Monthly Newsletter. 1

BETA OPTION 1: PERFORMANCE RATING METHOD. Section General Information

Broad Institute Expansion: Cambridge, Massachusetts. Mechanical Thesis Proposal : REVISION I

Name of Project: Address: Zip Code Owner/Authorized Agent: Phone # ( ) - Owned By: Select one Code Enforcement Jurisdiction: Select one

Building Energy Efficiency Analysis for a High School

Franklin Hall Renovation TABLE OF Document Indiana University Bloomington

Name of Project: Address: Zip Code Owner/Authorized Agent: Phone # ( ) - Owned By: Select one Code Enforcement Jurisdiction: Select one

Design and Construction AN ISO 9001:2008 CERTIFIED ORGANIZATION

Energy Strategies That Work Case Studies

ADDENDUM 2 - JULY 14, 2015

35% reduction in water use below code maximum 83% 88% 49% reduction in lighting power density 12%

Next Generation: High Efficiency Energy Recovery Ventilator (ERV) 11/14/11 Dais Analytic Corporation

Seminar 4 Energy Performance of Active Chilled Beam Installations

April 16 th Linda Morrison Jesse Stanley

1.0 Total Points % 2.1 Building Exterior Elements % 2.2 Accessibility % 2.3 Structural %

Chilled Beams. The new system of choice?

Appendix J - Custom Uniformat for EDU Migration

The New Student Housing Building at The Mount St. Mary s s University Emmitsburg,, Maryland

Building Energy Efficiency Analysis for a High School

Building Energy Analysis for a Multi-Family Residential Building (Multi V III VRF Heat-Pump System)

THE NEW YORK TIMES BUILDING

Technical Report Three

Santa Fe County Sustainable Land Development Code ORDINANCE NO , December 8, 2015

GATES-HILLMAN CENTERS

CITY OF ANDERSON BUILDING AND CODES 601 South Main Street

Gerald R. Ford Museum

2000 Antwerp, terraced house

Thesis Proposal. Clemson University Advanced Material Research Laboratory Anderson, SC. David Anderson Mechanical Option. Photo by Fred Martin

Retail Effects of ANSI/ASHRAE/IES Standard

BIM Ex Plan Research Integration Model Codes Looking Forward

COMMERCIAL TENANT IMPROVEMENT PERMIT APPLICATION

Next Connecticut Energy Code

Mechanical Product Overview

Walter Reed National Military Medical Center Bethesda, MD

SOUTH DAKOTA BOARD OF REGENTS. Budget and Finance ******************************************************************************

CITY OF CALABASAS RESIDENTIAL PLAN REQUIREMENTS 1 OF 5 8/2017 PLAN INFORMATION

CREDIT COMPLIANCE (Please complete the color coded criteria(s) based on the option path selected)

Oklahoma University Children s Medical Office Building

OFFICE OF EDUCATIONAL FACILITIES FLORIDA BUILDING CODE SECTION 423 APPLICATION MATRIX

Building Services / MEPF Scopes

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

OUR PASSION: Your Engineer

Element Z General Design Requirements Existing Facilities Information

Thesis Proposal for Berks Classroom and Lab Building

TABLE OF CONTENTS Public Safety Building

Analysis of the Energy Savings Potential in K-5 Schools in Hot and Humid Climates. Jeff S. Haberl, Ph.D., P.E.

Coppin State University Physical Education Complex - Technical Report 2

About Southface. Southface promotes sustainable homes, workplaces and communities through education, research, advocacy and technical assistance.

FACILITY DESIGN PLAN FOR HARDING HALL RENOVATION AND ADDITION SOUTH DAKOTA STATE UNIVERSITY DATE: March 29, 2017

Commercial HVAC. Emerging Technologies

Design Standard Sustainability

SECTION AIR-TO-AIR ENERGY RECOVERY EQUIPMENT

DESIGN CHECKLIST PROJECT NAME DISCIPLINE DATE TYPE REVIEW REVIEWER DRAWINGS REVIEWED

45% 39% 17% 92% 100% All paints and adhesives are low VOC

Sustainability + Learning an equation for success at RVC

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

ENERGY PERFORMANCE DOCUMENTATION. Architecture at Zero dwellbeing San Francisco, CA

Residence Hall Retrofit: A Project to Reuse, Renew, Revive, Recycle, Recruit and Retain

Mechanical Systems Proposal

IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST

4043 N. Ravenswood Suite 207 Chicago, IL

LASALLE - BACKUS EDUCATION CAMPUS

Project Proposal Proposal for Investigation of Alternative Systems

LEED 2009 for New Construction and Major Renovations

DISTRICT WIDE STRATEGIES FOR ENERGY EFFICIENT SCHOOLS

NOTE: For construction other than new commercial or additions (renovations), only those areas below describing the scope of work will be applicable.

WEST VIRGINIA UNIVERSITY ALUMNI CENTER Morgantown, West Virginia

2012 INTERNATIONAL CODES SIGNIFICANT CHANGES

White Paper ENVELOPE-FIRST APPROACH TO NET-ZERO ENERGY BUILDINGS

Transcription:

RETROFIT OF HISTORIC WAREHOUSE TO NEW MEDICAL CLINIC IN TULSA, OK MECHANICAL TEAM 2010-5 JACQUELINE BAYER JEFFREY DOWGALA LIAM HENDRICKEN LAUREN MCNALLY APRIL 10, 2010

INTRODUCTION (CIRCA 1927)

PROPOSED NEW DESIGN

INTRODUCTION GOALS ASCE CHARLES PANKOW FOUNDATION ANNUAL ARCHITECTURAL ENGINEERING STUDENT COMPETITION INNOVATION SUSTAINABILITY DESIGN FOCUS EXISTING STRUCTURE MEDICAL CLINIC NEEDS TORNADO SHELTER TRIAGE CENTER

PROJECT REQUIREMENTS DISCIPLINARY COORDINATION ARCHITECTURAL CIVIL STRUCTURAL MECHANICAL HISTORIC PRESERVATION DEVELOP SAFE DESIGN DERIVED FROM CODES AND GUIDELINES TORNADO SHELTER TRIAGE CENTER

CODES & STANDARDS MULTI-DISCIPLINARY IBC, 2006 IEBC, 2006 TORNADO SHELTER REQUIREMENTS FEMA 361 SUSTAINABILITY LEED V3 2009

CODES & STANDARDS HVAC DESIGN GUIDELINES 2009 ASHRAE HANDBOOK -FUNDAMENTALS 2007 ASHRAE HANDBOOK HVAC APPLICATIONS IMC HVAC STANDARDS ASHRAE 90.1 2007 ASHRAE 62.1 2007 PLUMBING IPC FIRE PROTECTION NFPA 13: INSTALLATION OF SPRINKLER SYSTEMS, 2007 NFPA 101: LIFE SAFETY CODE, 2009

PROJECT MANAGEMENT: DESIGN PROCESS Architectural Design Site Design Structural Design Mechanical Design Tornado Shelter Design Building Integration

PROJECT MANAGEMENT: DESIGN PROCESS Concept Design Analytical Model Proposed Design Final Design Architectural Architectural Site Site Structural Structural Mechanical Mechanical Tornado Shelter Tornado Shelter

SITE LOCATION TULSA, OK BRADY ARTS DISTRICT SIZE OF SITE ~1 ACRE SITE USE OBJECTIVES PARKING SMALL PARK

SITE Park Medical Clinic

EXISTING FIRST FLOOR

EXISTING SECOND FLOOR

COMPETITION PROPOSED FIRST FLOOR

FINALIZED FIRST FLOOR Lobby Enhancement Tornado Shelter Fire Stair Tower

FINALIZED SECOND FLOOR Community Space Fitness Childcare Mechanical Room Alternative Mdii Medicine Fire Stair Tower Staff Room

CLIENT GOALS HVAC GOALS ROOM PRESSURIZATION MEET OR EXCEED FEMA VENTILATION REQUIREMENTS INNOVATION AND SUSTAINABILITY TEAM GOALS LOW LIFE-CYCLE COSTS REDUCE ENERGY CONSUMPTION AT LEAST 10% PRECISE TEMPERATURE AND HUMIDITY CONTROL

HVAC DESIGN CHALLENGES TORNADO SHELTER -SELF-CONTAINED SYSTEM LIMITED INTERSTITIAL SPACE COLLABORATING WITH STRUCTURAL ENGINEERS MINIMIZE HVAC AND FIRE PROTECTION PENETRATIONS IN TORNADO SHELTER EQUIPMENT PLACEMENT SUSTAINABLE PLUMBING SYSTEMS

HVAC INNOVATION GEOTHERMAL HEAT PUMP SOY-BASED SPRAY INSULATION FOAM ENERGY SAVING STRATEGIES RAINWATER HARVESTING LOW-FLOW FIXTURES

OUTDOOR DESIGN CONDITIONS ASHRAE ZONE 3A (www1.eere.energy.gov)

OUTDOOR DESIGN CONDITIONS REQUIRES HEATING, COOLING, AND HUMIDITY CONTROL Table D 1: Table Summarizing Tulsa Outdoor Design Conditions (Reference: ASHRAE 90.1, Table D 1) Latitude Longitude Elev., ft Heat DD Cool DD Heating Dry Cooling Dry Cooling Wet 36.18 N 95.90 W 668 3691 5150 9 F 97 F 76 F

INDOOR DESIGN CONDITIONS ASHRAE STANDARD 62.1, 2007 Room Classification Patient Relations, Orthography, ENT, Staff Areas Dry Bulb ( F) Relative Humidity (%) Sensible Gi Gain (W) Latent Gain (W) Lighting Gain (W/SF) 70 75 30 60 75 4500 55 3300 0.8 1.5 Surgery, 62 80 30 80 600 3300 440 2420 2.2 Procedure X Ray 78 80 40 50 75 55 0.4

BUILDING ENVELOPE CURRENTLY DOUBLE-WYTHE MASONRY NO MOISTURE PROTECTION LIMITED THERMAL RESISTANCE SOY-BASEDB SPRAY INSULATION FOAM WALLS AND ROOF IMPERMEABLE EFFECTIVE R-VALUE:12 HR-FT 2 - F/BTU TRIPLE PANE GLASS R-VALUE: 12 HR-FT 2 - F/BTU

HVAC LOAD CALCULATIONS Application Baseline R Value ASHRAE R value Actual R value Roof 625 6.25 20.83 27.03 Wall 4.15 11.9 17.86 Glazing 1.67 11.76 BASELINE - 115 TONS COOLING 690 KBTU/HR HEATING 60,000 CFM ACTUAL 95 TONS COOLING 400 KBTU/HRHEATING 50,000 CFM 16% REDUCTION

GEOTHERMAL PRIMARY SYSTEM HEAT PUMP CLIMATEMASTERM OUTSIDE AIR REQUIREMENTS REDUNDANCY WELLS (36) 500 VERTICAL WELLS 15 SPACING - COVERS 6,000 SF NO TEAR OUT LIFE-CYCLE COST

ZONING 1 ST FLOOR 2 ND FLOOR

SECONDARY SYSTEM CONSTANT AIR VOLUME TEMPERATURE AND HUMIDITY CONTROL SURGERY AND PROCEDURE ROOMS ROOM PRESSURIZATION DUCTED RETURN ENHANCED INDOOR AIR QUALITY

TORNADO SHELTER 2 REDUNDANT AHUS INDEPENDENT SYSTEM ONLY 2 MECHANICAL PENETRATIONS TORNADO RATED LOUVERS PROVIDE CONDITIONED AIR AFTER A TORNADO EVENT EXCEEDS FEMA VENTILATION REQUIREMENTS

ENERGY RECOVERY CLIMATEMASTER DESICCANT WHEEL (LATENT AND SENSIBLE) HEAT RECOVERY VENTILATOR (SENSIBLE) ( ) EXHAUST FANS PLUMBING APPLICATIONS

PLUMBING DESIGN CHALLENGES MEET IPC, 2006 REQUIREMENTS 10 WATER CLOSETS 8LAVATORIES 3 DRINKING FOUNTAINS REDUCE WASTE WATER BY 50% GREY WATER RAINWATER LOW-FLOW FIXTURES

PLUMBING DESIGN BASELINE LAVATORIES IN BATHROOMS AND EXAM ROOMS 47 LAVATORIES 350 COLD/350 HOT GALLONS DAILY WATER CLOSETS IN BATHROOMS 20 WATER CLOSETS 1760 COLD GALLONS DAILY

PLUMBING DESIGN PLUMBING EFFICIENCY STRATEGIES GREY WATER USE LAVATORY WATER IN WATER CLOSETS 28% WATER REDUCTION RAINWATER 42 RAINWATER ANNUALLY / 20,000 SF ROOF 41% WATER REDUCTION LOW-FLOW FIXTURES SENSOR / DUAL-FLUSH TOILETS 37% WATER REDUCTION

FIRE PROTECTION GOALS PROTECTION OF LIFE PROPERTY BUILDING OPERATION NFPA 13 AND 101

FIRE PROTECTION DESIGN LIGHT HAZARD FACILITY WET PIPE SYSTEM WITH 200 SF COVERAGE PER SPRINKLER HEAD PIPE SIZING NFPA 13, 2007 0.07GPM/SF 100 GPM FOR INDOOR/OUTDOOR HOSE DURATION OF 30 MINS 5,100 GALLONS (TORNADO( SHELTER) ) 85,000 GALLONS (REST OF BUILDING)

FIRE PROTECTION DESIGN HVAC AND ADDITIONAL REQUIREMENTS DEDICATED SMOKE EXHAUST SYSTEM FIRE SMOKE DAMPERS FIRE EXTINGUISHERS HORN AND STROBE NOTIFICATION ALARM PULL STATIONS

SUSTAINABILITY LEED 2009 NEW CONSTRUCTION AND MAJOR RENOVATIONS SILVER CERTIFICATION (55 POINTS) MECHANICAL ACHIEVEMENTS WATER EFFICIENCY RAINWATER HARVESTING ENERGY REDUCTION INDOOR ENVIRONMENTAL QUALITY

CLIENT BUDGET BUDGET COST CONSTRUCTION $3,227,825 FURNISHINGS $775,000 DESIGN $330,000 PERMITTING FEES $10,000000 LAWYER & BOND COSTS $50,000 SITE A ACQUISITION $0 TOTAL: $4,400,000

INTEGRATION AND COLLABORATION COORDINATION ARCHITECTURAL, STRUCTURAL, MECHANICAL, ETC. TORNADO SHELTER NEW BACKUP WALL CONSTRUCTION BUILDING INFORMATION MODELING: REVIT 2010

RETROFIT OF HISTORIC WAREHOUSE TO NEW MEDICAL CLINIC IN TULSA, OK MECHANICAL TEAM 2010-5 JACQUELINE BAYER JEFFREY DOWGALA LIAM HENDRICKEN LAUREN MCNALLY