ADDRESS: 122 LIPSCOMBE ROAD, DECEPTION BAY, QLD,

Similar documents
CANTILEVER RETAINING WALLS - KOPPERS ROUNDWOOD POSTS FOR WALL HEIGHTS 0.3m to 1.8m

reinforced besser block retaining walls

Galintel RETAINING WALL POST. Installation Guide. The Galintel brand is proudly owned by

NOVEMBER 2016 GRANDWALL. retaining walls installation guide

freestone eco Prestige & quality DIY vertical wall Large blocks - 10/m 2 Smooth surface finish No concrete footings

Retaining Wall System

Tasman Retaining Wall System

FREESTONE ECOTM. Retaining Wall SystemTM. No one knows Blocks and Pavers better

AUGUST 2017 HASTINGS. retaining walls installation guide

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

PISA. Retaining Wall System. The choice of professional contractors

SPECIFICATION FOR REINFORCED SOIL WALL

Tasman Retaining Wall System

MagnumStone Specifications Gravity

Retaining Guide. TerraFirm mm. 500mm (typical)

STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 9/17/18)

BACKYARD BLOCK australianpaving.com.au

Retaining Guide. TerraFirm mm. 750mm (typical)

CHAPTER 11: WALLS.

Features Include: Near Vertical Walls Do it Yourself No Concrete Footings Required

Earth Retaining Structures and Systems Submittal Checklist. Part One: Materials and Material Properties

See the IRC for additional information. See CPD-DS Information Bulletin 100 for Requirements for 1 & 2 Family Dwelling plan submittals.

UPRR INDUSTRIAL LEAD BRIDGE T-WALL RETAINING WALL SYSTEM 5.0 x 7.5 UNITS DESIGN UNIT 018 WORK PACKAGE 04

ITEM 481 MONOLITHIC REINFORCED CONCRETE BOX SEWERS

PENTABLOCK Technical Information 190mm Series

GRANDE WALL large CONCRETE BLOCKS FOR THE CONSTRUCTION OF RETAINING WALLS. 1339_Feuillet_Permacon_Grande_ang.indd 1

GEOTECHNICAL INVESTIGATION PROPOSED OUTFALL LOCATION CITY OF MORGAN S POINT DRAINAGE HARRIS COUNTY, TEXAS REPORT NO

product range HAMPTON LONSDALE BRIGHTON COVE BLACKWOOD MCLAREN SORRENTO E:

RETAINING WALL SYSTEMS SOUTH & NORTH QUEENSLAND

GUIDELINES FOR RETAINING WALLS 4-0 IN HEIGHT OR LESS

CAPRICORN MUNICIPAL DEVELOPMENT GUIDELINES

RETAINING WALL LEVEL BACKFILL

SECTION MECHANICALLY STABILIZED EARTH RETAINING WALLS

GRADING, FILL, EXCAVATION AND LANDSCAPING 2012 EDITION

ARMOR-BLOCK. Installation guide. Installation Manual: ARMOR-BLOCK Retaining Wall System. Cap Block. Exposed void for planting.

Topic: Site Formation

Earth Retaining Walls CIVL455 CHAPTER I: INTRODUCTION

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

SPECIFICATION FOR MAGNUMSTONE GEOGRID REINFORCED Mechanically Stabilized Earth (MSE) SYSTEM

PRODUCT RANGE JUNE 2018

Gravity Wall. A force to be reckoned with... Gravity (SRW) segmental retaining wall systems are structures

Lecture Retaining Wall Week 12

FACSIMILE/ MAIL TRANSMISSION. Date: December 2, 2011 File:

PROPOSED SEGMENTAL RETAINING WALLS ARGONAUT RETAIL VILLAGE - PHASE I PENSACOLA, FLORIDA

CAPRICORN MUNICIPAL DEVELOPMENT GUIDELINES PRECAST BOX CULVERTS CONSTRUCTION SPECIFICATION

NPTEL Course. GROUND IMPROVEMENT Factors affecting the behaviour and performance of reinforced soil

ArmorWire Cable Barrier

TUNNEL LINER PLATE INTRODUCTION GENERAL APPLICATIONS CHAPTER 11

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

DESIGN CONSIDERATIONS FOR NSWS NATURAL STONE RETAINING AND FREE-STANDING WALL SYSTEMS

Five Stone System. Trench Depth Compactible Rock. Foundation. 57 lbs 41 lbs 31 lbs 47 lbs. Patent Pending. Approximate Weight

Date: December 7, 2017 Project No.:

ETTAMAR, INC. Engineers and Consultants TBPE # Joe DiMaggio Blvd. Suite 28, Bldg. 300 Round Rock, TX (512) (512) FAX

MOA Project # Golden View Drive Intersection & Safety Upgrades

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

CONCRETE SEGMENTAL RETAINING WALLS

CAPRICORN MUNICIPAL DEVELOPMENT GUIDELINES

Pulaski County, Virginia

ENGINEERING DIRECTIVE

TIMELESS BEAUTY Experience Old-World Charm on a Grander Scale...

DESIGNING AND CONSTRUCTION OF T-WALL RETAINING WALL SYSTEM

twenty four foundations and retaining walls Foundation Structural vs. Foundation Design Structural vs. Foundation Design

Design and monitoring of EPS embankment on D1 near Ivanovice in the Czech Republic

Design of Soil Nailed Walls According to AS

masonry. style and function Keystone High Performance Segmental Retaining Wall Systems

STORMCAPTURE. Installation Manual

Technical Data Sheet Timber Retaining Walls for Residential Applications 9

Earth Retaining System

CITY OF ORANGE PUBLIC WORKS DEPARTMENT GRADING FIELD INSPECTION REQUIREMENTS

SPECIFICATION FOR CORNERSTONE GEOGRID REINFORCED SEGMENTAL RETAINING WALL SYSTEM

CONCRIB SEGMENTAL RETAINING CRIBWALL

Building. Anchorplex. Retaining Wall Systems

KEYSTONE. high performance segmental retaining walls

Anchorplex retaining wall construction guide. Building. Anchorplex. Retaining Wall Systems

Downloaded from Downloaded from /1

RETAINING WALL SYSTEMS

VERTI-BLOCK - DESIGN MANUAL

INSPECTION GUIDE FOR SEGMENTAL RETAINING WALLS TEK 18-11B

5 ¼" (H) x 6 ¾" (W) x 9" (D) minimum. 5 ¼" (H) x 10 ½" (W) x 9" (D) minimum. 5 ¼" (H) x 13 ¾" (W) x 9" (D) minimum

SECURE & STYLISH FENCING, WE'LL BRING THE GOOD NEIGHBOUR DESIGN GUIDE: GOOD NEIGHBOUR FENCING

Anchorplex retaining wall construction guide

PROJECT: SLAB DESIGN SITE ADDRESS LOT 36, HAMISH ROAD, DARLEY VICTORIA 3340

Terraces. Terraced hillsides may require engineering assistance. Contact your C&M Representative for more information.

Universal Armorwire Terminal End

Draft. Not Yet Approved SECTION 10.1 GENERAL SCOPE DEFINITIONS

16. Design of Pipeline Structures.

Notes for Erection of Evergreen Maxi Wall Retaining Walls

DIY Garden Wall. Planning your Project Easy Step by Step Guide Simple Illustrations Maintainence

Misan University - College of Engineering Civil Engineering Department

Transcription:

WWW.TUFFOZYCONCRETESLEEPERS.COM.AU ADDRESS: 122 LIPSCOMBE ROAD, DECEPTION BAY, QLD, 4508 EMAIL: SALESTUFFOZYCONCRETESLEEPERS@HOTMAIL.COM PHONE: 0405233099

1.0 INTRODUCTION 1 2.0 DESIGN ASSUMPTIONS 1 2.1 SLEEPERS 1 2.2 POSTS 1 2.3 FOOTINGS 2 2.4 FENCES 2 2.5 FOUNDATION 3 2.6 SURCHARGE 4 2.7 DRAINAGE 4 2.8 BATTERING 5 2.8.1 POST BATTER 5 2.8.2 SUBGRADE BATTER 5 2.8.3 BACKFILL BATTER 5 2.9 WALL TERRACING 5 3.0 RELEVANT AUSTRALIAN STANDARDS 6 4.0 SELECTION PRECEDURE / EXAMPLE 7 5.0 DESIGN GRAPHS 8 5.1 SAND / GRAVEL FOUNDATION 9 5.2 SOFT CLAY FOUNDATION 10 5.3 STIFF CLAY FOUNDATION 12

This brochure has been produced with the intent of providing design information and guidance for those wishing to install a sleeper retaining wall using Tuff Ozy Concrete Sleepers. User friendly design graphs have been compiled by Alta Projects, and can be found in section 5.0 of this document. The design assumptions used to assemble these graphs are discussed in detail throughout this brochure, and have been selected so that the advice given will be applicable to the majority of sleeper retaining wall applications throughout Queensland. If you are in any doubt as to whether your proposed retaining wall is covered by the recommendations contained within this document, please consult a registered engineer for further advice. An example of the appropriate selection procedure has also been provided in section 4.0 of this brochure for your convenience. The following design assumptions have been used to produce the design graphs located in section 5.0 of this brochure. They have been selected from the relevant Australian Standards with the intent of covering the majority of sleeper retaining wall applications throughout Queensland. It is imperative that you ensure that all of the following design assumptions are suitable for your proposed sleeper retaining wall application, prior to using the provided design graphs. If in any doubt, or if your proposed sleeper retaining wall falls outside the scope of this document, please ensure that you seek expert advice from a registered engineer. Tuff Ozy concrete sleepers are to be used within these retaining walls. We precast our sleepers in N40 concrete, and reinforce them with 2N12 longitudinal reinforcing bars, with 30mm minimum cover. Our standard sleepers are 80mm thick and 200mm high, and are typically made in 1000, 1200, 1500, 2000 and 2400mm lengths. Use packers under bottom row of sleepers to achieve horizontal alignment if required. Maximum retaining wall heights within this design guide are limited by the capacity of a single sleeper layer when posts are spaced at 2.4m centres. Double sleeper layers within larger posts will allow for larger retaining heights. The design graphs in section 5.0 of this brochure recommend the use of either 100UC14.8 or 150UC23 posts, depending on the proposed wall height. These posts 1

are to be Grade 300 and are to be hot dipped galvanised to a system designation of HDG600. This will ensure 25+ years of post durability before first maintenance is required within atmospheric corrosion category C in accordance with AS/NZS 2312 2002. Sleeper retaining walls within this brochure are not permitted to be installed within 1km of the coastline, or a large body of salt water. Please seek expert advice from a registered engineer for sleeper retaining walls within this exclusion zone, or where proposed post sizes vary from the above mentioned. 100UC14.8 posts are to be cast into bored piers of 400mm minimum diameter, and 150UC23 posts are to be cast into bored piers of 450mm minimum diameter. Posts are to be embedded into the footings, and extend to 100mm from the base of the bored pier excavation (refer Figure 4 in section 5.0). Footings are to be cast in a minimum of N25 concrete, with 100mm minimum cover to post. Allow a minimum of 48 hours for the concrete footings to set prior to installing sleepers. Please note that the footing depths recommended within the design graphs are to be considered as absolute minimum values. Footing depths are critical to the integrity of cantilever retaining walls, and hence a conservative approach should be adopted where possible. Ensure that no underground services will be affected by the installation of your sleeper retaining wall. Seek expert advice if the proposed bored pier footings are within the zone of influence of any nearby underground service. A fence up to 1800mm high is permitted to be installed on top of the proposed sleeper retaining wall, provided the appropriate design graph is used for the selection procedure. For example, the following 3 fence design options have been supplied within each subgrade category; No Fence: There will be no fence fixed to the top of the wall. General Zone: A maximum 1800 high fence that is further than 3.6m away from a free end may be installed on top of the wall. Fence posts located within this general zone are subjected to only half the wind pressure of those within the end zone. End Zone: A maximum 1800 high fence that is within 3.6m away from a free end may be installed on top of the wall. Fence posts located within this end zone are subjected to twice the wind pressure of those within the general zone. 2

The following maximum wind speed parameter have been adopted from AS/NZS1170.2 2011, and used to calculate the design graphs (with a fence allowance) in section 5.0 of this brochure; Wind Region = B Terrain Category = 2 Importance Level = 1 Design Life = 50 years Please note that this design guide does not cover fences within cyclonic areas. If you are unsure whether these design wind speed assumptions are suitable for your proposed fence, or for areas of greater wind loading (e.g. cyclonic areas), please seek expert advice from a registered engineer. Proposed fences on top of sleeper retaining walls are to be designed and certified by others. The design guidelines provided within this brochure assume that subgrade and backfill (refer Figure 4 in section 5.0) comprise of the same material (e.g. the foundation). It is also assumed that subgrade into which the footings are to be founded is in an undisturbed natural state. Backfill behind the retaining wall is to be placed as Controlled Fill Class 1 as specified in AS4678 2002. This requires fill to be compacted in layers of 200mm maximum thickness at +/ 2% of optimum moisture content, with compaction levels to achieve 98% of the soil s maximum dry density. Please note that care should be taken using heavy machinery within the immediate vicinity of the retaining wall. The following minimum soil parameters have been assumed for the calculation of the design graphs in section 5.0 of this brochure; Foundation Density Angle of Internal Friction Cohesion Sand / Gravel 1900kg/m³ 30 0kPa Soft Clay 1900kg/m³ 25 25kPa Stiff Clay 1900kg/m³ 25 75kPa If you are unsure whether these design soil parameters are suitable for your proposed sleeper retaining wall, please seek expert geotechnical advice. Similarly, if the proposed foundation material is not covered by the above table (e.g. rock, silt, etc.), or if the soil parameters are less desirable than the assumed values, expert advice should be sought from a registered engineer. 3

This brochure assumes that the potential failure of the proposed sleeper retaining wall will result in only minimal damage and loss of access, and has hence been designed to structure classification A in accordance with AS4678 2002. As such, a surcharge load of 2.5kPa acting at the top of the wall has been allowed for. If your proposed sleeper retaining wall requires a larger surcharge allowance, or is of a higher structure classification, please seek expert advice from a registered engineer. House footings, or other heavily loaded foundations are to be founded below the angle of influence of the proposed sleeper retaining wall (refer Figure 1 below). If this is unavoidable, then expert advice from a registered engineer should be sought. Figure 1 Sleeper Retaining Wall Angle of Influence The design graphs in section 5.0 of this brochure have made no allowance for hydrostatic loads (e.g. water pressure). As such, it is imperative that the wall builder implements an appropriate and effective drainage system behind the wall. It is 4

recommended that a geotextile layer be placed against the rear face of the sleepers, followed by a 200mm drainage layer (e.g. gravel). A 100mm diameter slotted and sleeved agi pipe is to be placed within the drainage layer at the base of the wall, and is to discharge to stormwater infrastructure (refer Figure 4 in section 5.0). An impermeable clay layer or cut off drain should also be placed at the top of the wall to reduce the risk of any potential hydrostatic pressures acting on the wall. It is important to consider the effect of post, subgrade, and backfill batters prior to installing a sleeper retaining wall. The following sub sections discuss the design assumptions made regarding the abovementioned batters. Posts for sleeper retaining walls greater than 1000mm high are to be laid back at a minimum batter of 1 in 20 (refer Figure 4 in section 5.0). Posts for walls less than 1000mm high may be installed vertically (e.g. no batter). Subgrade shall remain flat (e.g. no batter) for a minimum of 500mm in front of the sleeper retaining wall, after which it may begin to slope away from the wall at a maximum batter of 1 in 5 (refer Figure 4 in section 5.0). Expert advice should be sought if this is not achievable. The design graphs in section 5.0 of this brochure have made no allowance for a battered backfill (refer Figure 4 in section 5.0). If the backfill behind the proposed wall will not be flat (e.g. horizontal), then please seek expert advice from a registered engineer. Terracing of multiple sleeper retaining walls is permitted, provided that the distance between the two walls is at least twice the height of the lower wall (refer Figure 2 over page). 5

Figure 2 Sleeper Retaining Wall Terracing The following list of Australian Standards were referenced during the production of the design graphs in section 5.0 of this brochure; AS/NZS1170.0 2002 Structural Design Actions Part 0: General Principals AS/NZS1170.0 2002 Structural Design Actions Part 2: Wind Actions AS/NZS2312 2002 Guide to the Protection of Structural Steel Against Atmospheric Corrosion by the use of Protective Coatings AS3600 2009 Concrete Structures AS4100 1998 Steel Structures AS4678 2002 Earth Retaining Structures 6

The following is an example of the step by step procedure required to interpret the design graphs from section 5.0 of this brochure. Step 1: Select appropriate foundation material based on professional geotechnical advice E.g. Foundation = Stiff Clay Go to Stiff Clay design graphs in section 5.3 Step 2: Select appropriate fence design option based on proposed wall design E.g. 1800 High Fence General Zone Go to the General Zone design graph Step 3: Select appropriate sleeper retaining wall height based on site measurement/survey E.g. Wall Height = 1400mm Draw a horizontal line across the 1400 wall height axis Step 4: Select appropriate post spacing based on proposed wall design E.g. Post Spacing = 2000mm Draw a vertical line from intersection with graph Step 5: Read off the recommended post size and footing depth E.g. Therefore adopt 100UC14.8 posts and a footing depth of 1450mm. Refer to Figure 3 below for a diagrammatical explanation of the above design graph interpretation example. Figure 3 Design graph procedure / example 7

The information provided in the graphs within this section is intended for design guidance purposes only. Ensure that all of the design assumptions listed in section 2.0 are reviewed, and that your proposed sleeper retaining wall satisfies all the necessary criteria before using the below design graphs. If in any doubt regarding interpretation of the information provided, or if your wall falls outside the scope of this brochure, please seek expert advice from a registered engineer. We highly recommend engaging a registered geotechnical engineer to confirm the soil conditions prior to using these design graphs. This is particularly important for walls greater than 2000mm high, as they generally have a larger consequence of failure. Sleeper retaining walls designed using the following graphs are to be constructed in general accordance with the specifications listed throughout this brochure, and with the typical configuration diagram shown in Figure 4 below. Figure 4 Typical Sleeper Retaining Wall Configuration 8

Figure 5 Sand / Gravel (No Fence) Design Graph Figure 6 Sand / Gravel (1800 Fence General Zone) Design Graph 9

Figure 7 Sand / Gravel (1800 Fence End Zone) Design Graph Figure 8 Soft Clay (No Fence) Design Graph 10

Figure 9 Soft Clay (1800 Fence General Zone) Design Graph Figure 10 Soft Clay (1800 Fence End Zone) Design Graph 11

Figure 11 Stiff Clay (No Fence) Design Graph Figure 12 Stiff Clay (1800 Fence General Zone) Design Graph 12

Figure 13 Stiff Clay (1800 Fence End Zone) Design Graph 13