DURASHIELD 210 &

Similar documents
DURASHIELD 210 &

APPLICATION SPECIFICATION SHEET GENERAL INDUSTRIAL EFFECTIVE: 01/09/12

DURASHIELD 310 &

DURASHIELD 110 &

DURASHIELD JARS APPLICATION SPECIFICATION SHEET FIELD-APPLIED JOINT & REPAIR SYSTEM (JARS) EFFECTIVE: 6/2/15

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents.

Elastocoat Protective Coatings APPLICATION GUIDE

3M Scotchkote Liquid Epoxy Coating 323+

POLYURETHANE COATINGS ON STEEL OR DUCTILE IRON PIPE

Nap-Gard Plant Application - Nap-Gard Gold Dual Powder System on Line Pipe Revised: 17 September 2013

COATING INSPECTION PRACTICES Prepared by: Don Holt VP Technical Sales-Wilko Paint, Inc.

Quality Control Instrumentation for Paint and Coating Installations. William Corbett, KTA-Tator, Inc.

COATING NEW STRUCTURAL STEEL SIGN SUPPORT STRUCTURES - Item No. Special Provision No. 911S09 November 2006

COATING SPECIFICATION EPOXY MASTIC, POLYURETHANE TOP COATING ON FUSION BONDED POLYETHYLENE COATING (SINTAKOTE )

Joint Surface Preparation Standard. NACE No. 3/SSPC-SP 6 Commercial Blast Cleaning

Food Service FDA Title 21 CFR

Rust-Oleum Industrial Brands Specification

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

PROLINE MID-TEMPERATURE VINYL ESTER LINING INSTALLATION GUIDE ProLine 4865T with optional 4822S Gel Coat Food Service FDA Title 21 CFR 175.

Application Guidelines

Prepared By: Engineering Staff Approved By: Jerome T. Schmitz

Armor Plate Pipe Wrap

APPLICATION GUIDELINE FOR

TECHNICAL REQUIREMENTS AND SPECIFICATIONS. PROTECTIVE COATING OF STEEL (As Provided by Raven Lining Systems) FOREWORD

Rust-Oleum Industrial Brands Specification

FIELD JOINT COATING AND REPAIRS PROCEDURE. Table of Contents. Section 1. Introduction Purpose and Limitations. Section 2. Terms and Definitions

NAPCA Bulletin

GUIDE SPECIFICATION SECTION 07576

SSPC: The Society for Protective Coatings. Commercial Blast Cleaning

APPLICATION GUIDELINE FOR

Application Guidelines

Product Information CHEMGLAZE B 9942 A/B. Coating for Casting Pits. Easy Application Chemglaze B 9942 A/B will bond to damp and wet surfaces.

Rust-Oleum Industrial Brands Specification

Girth Weld Coating With Fusion Bond Epoxy

Application Guide HI-TEMP 1027 APPLICATION GUIDE. Number: AG-3001 Revision: Page 1 of Introduction. 2. Where to apply Hi-Temp 1027

Refer to Substrates & Surface Preparation.

PRODUCT DATA SHEET SP-3888

Protective Industrial Polymers - USA Manufacturer s Specification February 11, 2015

TNEMEC ELEVATED TEMERATURE VINYL ESTER LINING INSTALLATION GUIDE ProPolymer Series 1402, 1422 and 1432 Direct Food Contact FDA Title 21 CFR 175.

Application Guidelines

IMTECH ADHESIVE SYSTEMS

A/D Firefilm III PRODUCT DATA SHEET

Aliphatic Acrylic-Polyester Polyurethane

SECTION CERAMIC EPOXY LINING DUCTILE IRON PIPE AND FITTINGS

1.04 REFERENCES STANDARDS.1 For reference standards tests & results refer to Manufactures Product Data Sheets

SSPC: The Society for Protective Coatings. White Metal Blast Cleaning

Specification for Fusion Bond Epoxy Coating

Rust-Oleum Industrial Brands Specification

Intercure 99NA Application Guidelines

TS 24 SOUTH AUSTRALIAN WATER CORPORATION

Fireside 258. Fireside 258 is very stable and will neither outgas, nor cause skin irritations like many other high temperature coatings.

PRODUCT GUIDE: ZINC-RICH COATINGS. Version:

COATING SPECIFICATION HIGH BUILD CERAMIC FILLED EPOXY COATING ON NEW AND EXISTING PUMPS COATING SPECIFICATION: F3 ISSUE: 1 DATE: 12 DECEMBER 2012

Bharat Heavy Electricals Limited Piping Centre Chennai-17. Specification Number Revision Number Sheet Number PC:E:GF: of 7 CONTENTS

Solventless two-component crosslinked epoxy

PPI NBR: H (REV 01) DATE: September 02, 2005

SSPC: The Society for Protective Coatings. Brush-Off Blast Cleaning

AMERLOCK 2 AL. PRODUCT DATA SHEET September 12, 2018 (Revision of May 2, 2018) DESCRIPTION. Fast Dry Aluminum Epoxy Mastic Coating

GULF COAST PAINT MFG., INC

ITW- American Safety Technologies

1/16 Single Broadcast Polymer Flooring System

COATING SPECIFICATION HIGH BUILD EPOXY COATING ON BUTTERFLY VALVES COATING SPECIFICATION: D2 ISSUE: 2 DATE: FEBRUARY 2016

3M Scotchkote Liquid Epoxy Coating 323+

Refer to Substrates & Surface Preparation.

TL-280 Sprayable Flake Glass Vinyl Ester Lining System

Ganicin 2.8 ZR-E Zinc-Rich Epoxy Primer

SECTION STEEL PIPE COATING AND LINING. 1. Exterior: Polyurethane coating with a cement mortar armor coating. 2. Interior: Polyurethane lining.

Note: This specification was written for Clarabelle Mill's flotation cells but may have other applications.

SURFACE PREPARATION AND APPLICATION GUIDE

Application Procedures for Uncured Rubber Linings on Pipe

Application Guide for Internal Flow Efficiency Coating Jotapipe FC 400

COATING SPECIFICATION ZINC RICH EPOXY PRIMER, EPOXY MASTIC COATING ON STEEL OR CAST IRON COATING SPECIFICATION: C3 ISSUE:2 DATE: OCTOBER 2016

NAVSEA REVIEWED ASTM F-718. Interline 783 Finish, Ultra High Solids Two-Pack Fast Cure Solvent-Free Coating

QUALITY CONTROL OF SURFACE PREPARATION AND COATING INSTALLATION ON PIPELINE GIRTH WELDS

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Tunnel Painting

Special Specification 4038 Zinc Cathodic Protection System

ARDEX GUIDE SPECIFICATION ARDEX FEATHER FINISH Self-Drying, Cement-Based Finish Underlayment

Armor Plate 360 MP ( Multi-Purpose ) Pipe Wrap For External Corrosion and Mechanical Damage

Specification for Field Joint Coatings for Casing Pipes 1 of 12

The Application Guide offers product details and recommended practices for the use of the product.

SECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)

CONSTRUCTION SPECIFICATION FOR COATING STRUCTURAL STEEL SYSTEMS

QUALITY ASSURANCE MANUAL FOR APPLICATORS OF ELASTOMERIC SHEET LININGS

Ganicin 2.8 ZR- U Zinc-Rich Polyurethane Primer

Heresite P-413 TECHNICAL DATA SHEET. P-413 Typical Properties 1 mil DFT) Our 50 years of coating history speaks for itself.

SECTION POLYURETHANE MIC COATINGS. A. Furnish and install special coating systems in accordance with the Contract Documents.

Application Guide for Internal Flow Efficiency Coating

ADDENDUM TO THE CONTRACT. for the. East Valley Reservoir Exterior and Lemon Creek Reservoir Interior Repainting. Contract No.

ITEM 431 PNEUMATICALLY PLACED CONCRETE. All material shall conform to the pertinent requirements of the following items:

SECONDARY CONTAINMENT COATING SPECIFICATION

Epoxy Application Procedures Technical Bulletin

Note: Epoxies will chalk and change color with exterior exposure. Colors are approximately and will tend to change over time.

SURFACE PREPARATION INSTRUCTIONS: CONCRETE

Rust-Oleum Industrial Brands Specification

IGS-C-TP-010-Amnd2 Oct IGS. Iranian Gas Standards -(./ !" # 3 % % 2 '(!)*+ Amendment No. 2 to Three Layer Polyethylene Coating System

.4 Submit proof of qualifications and authorization in writing to the Contract Administrator, four (4) weeks prior to commencement of Work.

NAVSEA Documents. Topics. Scope. Learning Outcome. Relevant Documents. NAVSEA Basic Paint Inspector Training: NAVSEA Documents

Instruction Guide APPLICATION OF CIM TO CONCRETE

METHOD STATEMENT. BluSeal Tekflex EXTERNAL CEMENT LATEX MEMBRANE

CIM IG 13 11/06. Instruction Guide

Transcription:

DURASHIELD 210 & 210-61 I. Scope A. This specification defines application requirements of DuraShield 210 & DuraShield 210-61 plural-component 100% solids, 2:1 volumetric mix ratio polyurethane to steel substrates and over-coat areas. B. The coating material described in this specification can be applied in either a shop or field environment. C. The parts to be considered by this specification are as follows: 1. Piping 2. Piping components elbows and tees 3. Girth welds/field joints 4. Valves 5. Repair areas 6. Other parts as directed by the end user. II. Definitions A. PART all service steel that is to be coated under the direction of this specification. B. APPLICATOR the company selected by the END USER to apply plural-component coatings to the internal and external surfaces of PARTS. C. MANUFACTURER the Company responsible for the chemical formulation and characteristics of the plural-component coatings applied to PARTS (LifeLast Inc. is the Manufacturer that is composed within these specifications). D. INSPECTOR the company or person selected by the END USER to ensure quality control of the work and adherence to this specification, where applicable. E. END USER the pipeline or part owner. F. RESIN the two-part component of the urethane system to be referred to as Part A. G. ACTIVATOR the one-part component of the urethane system to be referred to as Part B. III. Additional Requirements A. All specifications and standards mentioned in this document form part of this specification. The applicator shall ensure that a copy of this specification is kept at the coating site and shall ensure that their workers fully understand each specification and standard listed below. B. The following standards shall be a part of this specification. 1301 NE 144 TH STREET, SUITE 125 VANCOUVER, WA 98685 O: 360.254.0563 WWW.LIFELAST.COM

Society of Protective Coatings (SSPC) SSPC-SP1 Solvent Cleaning SSPC-SP10/ NACE No. 2 Near-White Metal Blast Cleaning SSPC-SP11 Power Tool Cleaning to Bare Metal SSPC-VIS-1-89 Pictorial Surface Preparation Standard NACE International RP0287-2002 NACE Standard Recommended Practice for Field Measurement of Abrasive Blast Cleaned Surfaces Using Replica Tape SP0188-2006 NACE Discontinuity (Holiday) testing of new protective coatings on conductive substrates. IV. Surface Preparation A. Prior to commencement of work, all parts shall be visually inspected. B. Rough welds and other sharp projections shall be ground smooth by the end user or as designated by the inspector. C. Prior to abrasive blast or power-tool cleaning the substrate, all contaminants such as dirt, dust, oil and/or grease must be removed in accordance with SSPC-SP1. D. The substrate shall not contain soluble salt concentrations in excess of the following values: chloride levels 3 ppm (micrograms per square centimeter), nitrates 5 ppm, sulfates 10 ppm. Surfaces with soluble salt concentrations in excess of these levels shall be treated until satisfactory results are achieved. E. Prior to abrasive blasting or grinding, the metal surface shall be dry and warmed to a temperature at least 3 C (5 F) above the dew point to prevent oxidation of the part after cleaning. The applicator shall use a contact thermometer, psychrometer, and psychrometric charts, or equipment that provides equivalent accuracy, to monitor these environmental requirements. F. All parts that are not to be abraded shall be adequately protected. G. All large surfaces to be coated will be prepared by abrasive blast cleaning. Smaller surfaces (less than 50 ft 2 ) may be prepared by power tool cleaning using a hand-held angle grinder. All blast media will be clean and clear of any contaminates, have a maximum of one percent (1%) free silica, and will meet the specification of the coating manufacture. A 24-grit 3M grinding disk (recommended for coating), a metal grinding disk (required for steel) or equivalent should be used with the angle grinder. H. All compressors shall be in good working order and have adequate separators, filters, and drains to ensure contaminants such oil and water are not deposited onto the steel surface. Accumulation of oil and moisture shall be removed by regular purging. I. For bare steel application an anchor pattern profile will be produced with a minimum average of 0.075 mm (3.0 mils). Individual measurements shall not be less than 0.065 mm (2.5 mils). Profile measurements shall be taken with replica tape and spring micrometer in accordance with NACE RP0287-2002. J. For larger parts and/or structures (> 50 ft 2 ), the substrate shall be abrasive blasted in accordance with the NACE No. 2/SSPC-SP10 specification to achieve an anchor pattern that is both sharp and angular. Smaller surface areas (< 50 ft 2 ) may be power tool abraded using an angle grinder with either a metal grinding disk (for steel) or 24-grit 2

3M grinding disk (for coating and/or steel) or equivalent in accordance with SSPC- SP11 specification. Grinding should be done in such a way to achieve the roughest surface possible, and the direction of the final grind marks should run perpendicular to the flow of water in the pipe. The applicator shall ensure the proper surface finish is attained by regular checks with the SSPC-VIS-1-89 Standard. Profile depth shall be check using replica tape and a spring micrometer (NACE RP0287-2002). Note: profile, particularly with power-tool preparation, should be deep enough such that it is very noticeable when scraping the end of a fingernail across the profile grooves. K. When over-coating existing coating material the applicator will verify adhesion compatibility with the coating manufacturer before proceeding. Once compatibility is determined, the existing coating shall be sweep blasted or abraded with a grinder to remove the gloss and provide a roughened surface suitable for over-coating. This process should remove approximately 1-3 mils of coating. L. Existing coating shall be feathered 4 cm (1.5 in.) to 8 cm (3 in.) when coating adjacent bare steel, such as girth welds. Prior to coating, the applicator will tape off, using duct tape, a line between feathered coating and the remaining non-blasted coating prior to application of new coating material, making sure that edge of tape is on the roughened coating. M. Profile measurements will be taken, at a minimum, at the start of each shift, after a shut down to refill blasting pot, and after every hour of continuous blasting. N. Cleaned surfaces shall be dry air blasted and either brushed off or vacuumed, in a matter to remove dust and debris prior to coating, and shall be coated before any rust blooming occurs. Any cleaned steel showing rust stains shall be re-prepared prior to coating. V. Coating Application A. The coating shall be applied according to the proceeding guidelines. B. Thinning is not allowed. C. The coating thickness shall be specified by the end user or the inspector. The minimum thickness for DuraShield 210 & DuraShield 210-61 is 20 mils. The applicator shall measure and record coating thickness using a thickness gauge that is acceptable to the end user/inspector. D. The relative humidity, dew point and steel surface temperature shall conform to the recommended parameters outlined in the DuraShield 210 and DuraShield 210-61 Technical Data Sheets. Ensure that the resin (Part A) and activator (Part B) components are within the recommended product Application Temperatures for the chosen application method as listed on the respective Technical Data Sheet. The applicator shall use a contact thermometer, a psychrometer and psychrometric charts, or equipment that provides equivalent accuracy, to monitor these environmental requirements. E. A list of approved application equipment can be found in Appendix 1. F. Application shall be done in a professional manner, mitigating runs and sags and providing complete coverage on all surfaces, including difficult to spray areas like welds, seams and angles. Application shall be accomplished in a manner that achieves as smooth and uniform of a coat as possible. G. If recoating is required, it must be accomplished prior to the maximum recoat window as listed on the Technical Data Sheet for the respective product. If the maximum recoat window is exceeded, then follow the instructions in Section IV.J above. 3

H. Refer to the DuraShield 210 and DuraShield 210-61 Technical Data Sheets for cure time required before placing system into service. VI. Inspection and Testing A. Visual 1. Coating shall be uniform in color. The coating shall be visually inspected and found to be free of blisters, cracks, pinholes, missed areas and excessive roughness. 2. Sags and runs shall be kept to a minimum. Excessive runs can be sanded smooth and overcoated with a layer of DuraShield 210 or DuraShield 310. B. Coating Thickness 1. During continuous spray operations, the coating thickness shall be measured using a wet film thickness gage whenever feasible. The dry film coating thickness shall be tested using a properly calibrated magnetic pull off or eddy current equipment after completion of each pipe. In either measure, if the thickness of the coating is below the minimum specified millage anywhere along the length of the pipe, then adjustments must be made to the spray system to account for this. 2. In field spray and hand application projects, the coating thickness shall be measured using a wet film thickness gage whenever feasible. At a minimum, the thickness shall be measured for every 50 ft 2 of sprayed area or every joint for joint repair applications. The dry film coating thickness shall be tested using a properly calibrated magnetic pull off or eddy current equipment after completion of each pipe or joint for joint repair applications. In either measure, if the thickness of the coating is below the minimum specified millage anywhere along the length of the pipe, then adjustments must be made to the spray system to account for this. C. Holiday Testing 1. Holiday testing will be conducted on the completed coating after cure or 24 hours, whichever is less, using a high voltage spark test in accordance with NACE Standard RP-0188. 2. Coating shall be at 75% or greater of its fully cured hardness value prior to holiday testing. 3. Coating thickness used for holiday detection shall be the minimum specified coating thickness. 4. All holidays shall be plainly marked immediately after detection and shall be repaired according to Section VII in this specification. 5. Holiday testing will be performed in such a way as to mitigate possible damage to the coating by performing as few of passes as required over the coating. VII. Coating & Joint Repairs A. Coating and joint repairs may be made with DuraShield 210, DuraShield 310, Dura- Shield 310 Trowel Grade, or the DuraShield 310 JARS (Joint & Repair System) kit. All three systems are available in NSF certified versions. B. Please follow the Application Specifications for the particular product chosen for the repairs. 4

Appendix 1: Approved Spray Application Equipment for DuraShield 210 and DuraShield 210-61 Polyurethanes I. DuraShield 210/DuraShield 210-61 A. Hydraulic Spray Machine 2:1 (Resin:Activator) volumetric ratio 1. Graco/Gusmer H-35 or HXP3 Spray Machine or comparable a) Setup #1: Resin #80 cylinder; Activator #40 cylinder b) Setup #2: Resin #120 cylinder; Activator #60 cylinder 2. Transfer Pumps a) Resin: 5:1 Graco Monark or larger b) Activator: 2:1 Graco FastFlo, 5:1 Graco Monark or larger 3. Mixers/Spray Guns a) Graco Restrictor Manifold (Restrictors Resin 0.032, Activator 0.024 ) or similar; two 8 long by ¼ diameter spiral tube mixers or one 5 Simpson static mixer; Graco Flex Gun or comparable. Acceptable tips and whip lines are as follows: b) Remote manifold with ⅜ x ¼ heated lines; two 8 long by ¼ diameter spiral tube mixers or one 5 Simpson static mixer; Graco Flex Gun or comparable. Acceptable tips and whip lines are as follows: c) Impingement-mix setup using Graco Fusion Air or Mechanical Purge Gun with 2:1 module (i.e. AR2232 or AR2942 for Air Purge and XF2332 for Mechanical Purge). Fusion Air Purge Gun must have an extension adapter for a contractor flat tip. Acceptable tips for each module size are as follows: AR2232: 0.035 to 0.040 AR2942: 0.046 to 0.052 XF2332: 0.038 4. Application Temperatures a) Static Mix Setup (1) Resin: 110ºF to 160 ºF (2) Activator: 90ºF to 160 ºF (3) Line Temperature: 110ºF to 160 ºF b) Impingement-Mix Setup (1) Resin: 130ºF to 160 ºF (2) Activator: 130ºF to 160 ºF (3) Line Temperature: 130ºF to 160 ºF 5. Spray pressures: 2000 psi minimum at the gun. B. Pneumatic Spray Machine 1. Graco HydraCat with King Airhead 2:1 ratio (Resin:Activator) or comparable 2. Transfer Pumps 5

a) Resin: 5:1 Graco Monark or larger b) Activator: 2:1 Graco FastFlo, 5:1 Graco Monark or larger 3. Mixers/Spray Guns a) Graco Restrictor Manifold (Restrictors Resin 0.032, Activator 0.024 ) or similar; two 8 long by ¼ diameter spiral tube mixers or one 5 Simpson static mixer; Graco Flex Gun or comparable. Acceptable tips and whip lines are as follows: b) Remote manifold with ⅜ x ¼ heated lines; two 8 long by ¼ diameter spiral tube mixers or one 5 Simpson static mixer; Graco Flex Gun or comparable. Acceptable tips and whip lines are as follows: c) Impingement-mix NOT ACCEPTABLE 4. Application Temperatures a) Static Mix Setup (1) Resin: 110ºF to 160 ºF (2) Activator: 90ºF to 160 ºF (3) Line Temperature: 110ºF to 160 ºF b) Impingement-Mix Setup NOT APPLICABLE 5. Spray pressures: 2000 psi minimum at the gun. 6