J1939 to NMEA2000 Adaptor Part Numbers: 3185 USER MANUAL

Similar documents
3601 E. 34th St. Tucson, AZ USA Tel Fax Web:

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2

CFL Series User Manual

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

APC Step-Down Transformer. Models: AP9626, AP9627, and AP9628

Model T2642E Wall Mount. Television Wall Mount with Tilt Option

Signal Follower Card. Instruction Manual Model C

TEACO TRUCK DOCK PARK ASSISTANT. MODEL DockView -16 FORWARD/REVERSE READING DISTANCE INDICATOR

Stretch Wire. P/N Rev. 2. IOM Stretched wire festoon manual

Instructions and E00 Series Sampling Module Extenders

Wash Down Duty Non-Contact Sensor

Agilent 16047D Test Fixture

CMR Quick Start Guide. CMR-5975 Digicast Media Router (MR-S2) Part Number MN-CMR5975-QSG REV. 3

Smart-UPS X-Series External Battery Pack Installation and Operation

PI /09 Dedicated to improving vehicle fun, safety & performance

Global Water Instrumentation, Inc.

Drag Chain Conveyor Installation and Operation Manual

OM-CP-QUADPROCESS 4-Channel Low Level DC Current Data Logger. OM-CP-OCTPROCESS 8-Channel Low Level DC Current Data Logger INSTRUCTION SHEET

H8SX/1650 Series E6000H TFP-120 User System Interface Board User s Manual HS1650ECN61H

Field Economy Unit Instruction Manual

Owner s Manual Calcite Cartridge System

INSTALLATION & OPERATION INSTRUCTIONS ICW-3 WINDOW INTERCOM

Agilent 16034E Test Fixture

END TRUCKS WHEEL SIZES: 9", 12", 15" & 18"

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

OptoLum MegaLine RGBW Luminaire

2 3 Rough-in Wiring Rough-in

Model 3185E DUAL TONE DECODER INSTRUCTION MANUAL

DUST FREE ACTIVE Total Home Air Purification

Dancer Duty Potentiometer

B4 Servo Cover Update S , V ipd #

Switch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches

P1902 Installation Manual

OM-90 SERIES Portable Temperature and Humidity Data Loggers. Shop online at omega.com

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

Festoon Manual Stretch Wire

Precision Roller Pinion System Models RPS16, RPS20, RPS25, RPS32, RPS40 LINEAR MOTION CONTROL PRODUCTS FORM NO. L A-1204.

General Safety Information

Continuous Wave Single Frequency Lasers. SCHERZO Series. 532nm 300mW

SAVE THESE INSTRUCTIONS

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Installation & User Manual

Infant Warmer Care Station Cabinet Light

RAPiD Safe Setup and Operation

User Manual. PAT-Stand-16 Docking Station. Release 1.3. November EL-CELL GmbH

Continuous Wave Single Frequency Lasers. SYMPHONY Series. 532nm 2000mW

INSTALLATION MANUAL Accordion Gangplank Model No. FBL-1000

Free-standing rail systems, adjustable. Item no:

Ignition Switch Replacement for 850/70 Series ipd # , #

Xxxxx Xxxxxx OM-CP-TEMP101A. Temperature Data Logger with 10 year battery life INSTRUCTION SHEET MQS5026/0117

TABLE OF CONTENTS. Section Paragraph Title Page. ADDENDUM Visual Index Quick Reference. 1 General Information 1-1

Festoon Manual Heavy Duty C-Track

M LIM Line Leak Interface Module Procedure Guide (only for the Integra 500)

HD Firewall Mount 850 all, S/V , C ipd #

3601 E. 34th St. Tucson, AZ USA Tel Fax Web:

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Model PVIV-PROBE-KIT. Electrical Contact Probe. User's Manual

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

ISIMET. E Series Enclosure. Custom Assemblies Installation, Maintenance, and Operation Instructions

Key-type Selector Switches

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

Thermoelectric Cooler

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols.

General Guidelines. Tools Required. Safety. Deluxe Steel Folding Scooter & Wheelchair Carrier Instructions for Part # SC500-V3

Operation and Service Manual

User s Guide OM240. Linear & Polynomial Conversion. Shop online at omega.com SM

Agilent 16048D Test Leads

4-Wire Buffer Amplifier. User Manual

MRac Trapezoidal Metal Roof Mounting System. Installation Guide

Lithonia Lighting Terms and Conditions of Sale

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

ipd Intercooler S60 5cyl turbo V70/XC70 5cyl turbo ipd #114813

SHCM SHOWER COLUMN INSTALLATION INSTRUCTIONS

MPM-10 Piezo Translator INSTRUCTION MANUAL

Rack Power Distribution Unit AP7562, AP7563, AP7564 General Information

Address: City: State: Zip: Day Phone: Fax: 5. Where Were Your Products Purchased and/or Installed: Installer s Name/Company:

Models FWB, LWB, MWB and HWB Brakes AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

CORNERVIEW SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

Global Water Instrumentation, Inc.

E3X-DRT21/SRT21/CIF11

J60 Lithium Ion UPS 350VA Model User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

DICKSON TH8 DICKSON. Temperature & Humidity Chart Recorder Operation. Useful Features. Applications & Product. Specifications. Product.

TAYLOR FORGE STAINLESS

USER MANUAL MODEL 1019 and 1019S DB-9 Async. Short Range Modem With Transformer Isolation

HDI 2200 Choke Position Indicator

92831 TEL: (714) FAX:

LIGHT CONTROLLER LC 500

1. DEFINITIONS 2. ORDERS, PRICES AND FEES

Global Water Instrumentation, Inc.

INSTALLATION PROCEDURE

DLB-23 Shower Enclosure Installation and User s guide

This product has been tested and certified to conform to ASTM F2456, Youth Resistant Firearms Container.

Keysight 16380C Capacitance Standard Set

RAPiD VEHICLE SAFE. Owner s Manual. Instructional videos for Hornady Security products are available at hornady.com. With patented RFID technology.

REUSABLE TOOL UNU-USB

Carbon Forged Steel Fittings

Carbon Forged Steel Fittings

Model HH Signal-Conditioner / Indicator

Transcription:

J1939 to NMEA2000 Adaptor Part Numbers: 3185 USER MANUAL Revision 1.01

1 Introduction...2 1.1 Firmware Revision...2 1.2 Product Features...2 2 Installation...3 2.1 Unpacking the box...3 2.2 Mounting the unit...3 2.3 Connecting the NMEA2000 Cable...3 2.4 Connecting the J1939 cable to the WAGO socket...4 2.5 J1939 Connections...4 3 Configuration...5 3.1 NMEA2000 Device Instance...5 4 Warranty... 8 5 Technical Support...9 1 of 12

1 INTRODUCTION The Offshore Dynamics NMEA2000 3185, J1939 to NMEA2000 Adaptor is designed to convert Engine, Transmission and Generator messages on the J1939 network onto the NMEA2000 network. This unit is designed to operate in a protected marine environment such as an engine room. It is very important that it is installed and set up correctly according to this manual. Please read and follow the installation and setup instructions carefully to achieve the best results. 1.1 Firmware Revision The information in this manual corresponds to firmware revision 1.1.3 1.2 Product Features The 3185, J1939 to NMEA2000 Adaptor has the following features: Connection to J1939 network using a 3 pole Wago cage clamp connector Green LED confirming valid J1939 message reception. NMEA2000 micro C interface plug User Settable a NMEA2000 Device Instance using rotary switch Blue LED confirming NMEA2000 transmission NMEA2000 Interface optically isolated from J1939 Power drawn only from NMEA2000 interface Panel or DIN rail mounting option NOTE: FOR SAFETY REASONS THIS UNIT DOES NOT HAVE THE CAPABILITY OF TRANSMITTING ANY MESSAGES ONTO THE J1939 NETWORK. 2 of 12

2 INSTALLATION 2.1 Unpacking the box You should find the following items in the 3185 shipping box: 1 x 3185 J1939 to NMEA2000 Adaptor 1 x Din Rail mounting Kit with 2 rail mounts and 4 countersunk M3 screws for rails 1 x 3185 User Manual (This document) 2.2 Mounting the unit The unit can either be mounted to a flat surface using 4 mounting screws. The unit dimensions and mounting hole locations are shown on the following drawing. Or the unit can be Din Rails mounted by attaching the Din Rail mounts to the case using the supplied M3 CSK screws and then clipping the unit to the Din Rail 2.3 Connecting the NMEA2000 Cable The unit is connected to the NMEA2000 network by the 5 way micro C socket on the front. Carefully attach the network drop cable to this plug and hand tighten until it it is fully seated. Take care to match the orientation of the pip inside the socket to the recess inside the drop cable plug. The other end of the drop cable should be connected to a suitable Tee connector on the NMEA2000 network backbone cable. 3 of 12

2.4 Connecting the J1939 cable to the WAGO socket The cables from the power-source to the external sockets are connected using the WAGO Cage Clamp terminal block. The wire should be stripped for 8mm and then the cage clamp opened with a small screwdriver in the slot above the wire connection. Then simply insert the wire into it s connection slot and release the cage clamp by removing the small screw driver. This will produce a secure gas tight connection on wire sizes from 0.08 1.5 mm² 2.5 J1939 Connections The terminal connections are numbered as follows: Terminal 1 Terminal 2 Terminal 3 CAN H (HIGH-level J1939 CAN bus line) Ground CAN L (LOW-level J1939 CAN bus line) These are marked on the unit case. 4 of 12

3 CONFIGURATION The following two items can be configured directly on the 3185 using the two small rotary switches. There are no other menu setups to worry about. 3.1 J1939 Source The J1939 Source dial is now redundant to the design and does not require setting to a specific setting. Dial can be set to 0 as a precaution. 9ABCDEF08 1234567 3.2 NMEA2000 Device Instance Each 3185 J1939 to NMEA2000 Adaptor connected to the NMEA2000 network needs to have a unique Device Instance Address. The Device Instance of each unit is set by turning the small rotary switch with a small screw driver. Valid Device Instances range from 0 through to F. J1939 Data Translated to NMEA2000 Type PGN No Parameters J1939 PGNs PGN61443 Engine Percent Load PGN61444 Engine Speed Percent Torque PGN65270 PGN65262 PGN65271 PGN65266 PGN65253 PGN65263 PGN65214 PGN65260 PGN65242 Engine Turbocharger Boost Pressure Engine Oil Temperature Engine Coolant Temperature Alternator Potential (Voltage) Engine Fuel Rate Engine Total Hours Operation Engine Coolant Pressure Engine Fuel Delivery Pressure Engine Oil Pressure Engine Rated Speed Vehicle Identification Number Software Identification 5 of 12

PGN61445 PGN65272 PGN65030 Transmission Current Gear Transmission Oil Pressure Transmission Oil Temperature Generator Average Line to Line Voltage Generator Average Line to Neutral Voltage Generator Average Frequency Generator Average Current NMEA2000 Parameter Group Numbers (PGNs) Type PGN No Parameters Periodic Data PGNs PGN127488 Engine Parameters PGN127489 Engine Parameters PGN127498 Engine Parameters PGN127493 Transmission Parameters PGN65030 Generator Average Basic AC Quantities Protocol PGN126464 Tx/Rx PGN List PGN126996 Product Information PGN059392 ISO Acknowledge PGN059904 ISO Request PGN060928 ISO Address Claim PGN126208 Command/Request Group Electrical and Mechanical Parameter Value Comment Operating Voltage 9 to 16 Volts DC Voltage Power Consumption 120mA Average Operating Load Equivalence Number 3 LEN Reverse Battery Protection Yes Indefinately Load Dump Protection Yes SAE J1113 Size mm 96 x 84 x 35 Weight gr 120 6 of 12

Environmental Parameter Value IEC 60954 Classification Protected Degree of Protection IP40 Operating Temperature -25 C to 50 C Storage Temperature -40 C to 70 C Relative Humidity 93%RH @40 per IEC60945-8.2 Vibration 2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 7 of 12

4 WARRANTY Offshore Dynamics warrants this product to be free from defects in materials and workmanship for one year from the date of original purchase. If within the applicable period any such products shall be proved to Offshore Dynamics satisfaction to fail to meet the above limited warranty, such products shall be repaired or replaced at Offshore Dynamics option. Purchaser s exclusive remedy and Offshore Dynamics sole obligation hereunder, provided product is returned pursuant to the return requirements below, shall be limited to the repair or replacement, at Offshore Dynamics option, of any product not meeting the above limited warranty and which is returned to Offshore Dynamics; or if Offshore Dynamics is unable to deliver a replacement that is free from defects in materials or workmanship, Purchaser s payment for such product will be refunded. Offshore Dynamics assumes no liability whatsoever for expenses of removing any defective product or part, or for installing the repaired product or part or a replacement therefore or for any loss or damage to equipment in connection with which Offshore Dynamics products or parts shall be used. The foregoing warranties shall not apply with respect to products subjected to negligence, misuse, misapplication, accident, damages by circumstances beyond Offshore Dynamics control, to improper installation, operation, maintenance, or storage, or to other than normal use or service. THE FOREGOING WARRANTIES ARE EXPRESSLY IN LIEU OF AND EXCLUDES ALL OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE. Statements made by any person, including representatives of Offshore Dynamics, which are inconsistent or in conflict with the terms of this Limited Warranty, shall not be binding upon Offshore Dynamics unless reduced to writing and approved by an officer of Offshore Dynamics. IN NO CASE WILL OFFSHORE DYNAMICS BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, DAMAGES FOR LOSS OF USE, LOSS OF ANTICIPATED PROFITS OR SAVINGS, OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE. IN NO EVENT SHALL OFFSHORE DYNAMICS AGGREGATE LIABILITY EXCEED THE PURCHASE PRICE OF THE PRODUCT(S) INVOLVED. OFFSHORE DYNAMICS SHALL NOT BE SUBJECT TO ANY OTHER OBLIGATIONS OR LIABILITIES, WHETHER ARISING OUT OF BREACH OF CONTRACT OR WARRANTY, TORT (INCLUDING NEGLIGENCE), OR OTHER THEORIES OF LAW WITH RESPECT TO PRODUCTS SOLD OR SERVICES RENDERED BY OFFSHORE DYNAMICS, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATING THERETO. OFFSHORE DYNAMICS does not warrant that the functions contained in any software programs or products will meet purchaser s requirements or that the operation of the software programs or products will be uninterrupted or error free. Purchaser assumes responsibility for the selection of the software programs or products to achieve the intended results, and for the installation, use and results obtained from said programs or products. No specifications, samples, descriptions, or illustrations provided by Offshore Dynamics to Purchaser, whether directly, in trade literature, brochures or other documentation shall be construed as warranties of any kind, and any failure to conform to such specifications, samples, descriptions, or illustrations shall not constitute any breach of Offshore Dynamics limited warranty. WARRANTY RETURN PROCEDUREe To apply for warranty claims, contact Offshore Dynamics or one of its dealers to describe the problem and determine the appropriate course of action. If a return is necessary, place the product in its original packaging together with proof of purchase and send to an Authorized Offshore Dynamics Service Location. You are responsible for all shipping and insurance charges. Offshore Dynamics will return the replaced or repaired product with all shipping and handling prepaid except for requests requiring expedited shipping (i.e. overnight shipments). Failure to follow this warranty return procedure could result in the product s warranty becoming null and void. Offshore Dynamics reserves the right to modify or replace, at its sole discretion, without prior notification, the warranty listed above. 8 of 12 8 of 12

5 TECHNICAL SUPPORT If you require technical support for any Offshore Dynamics products you can reach us using any of the following ways: Tel: +44(0)1425 610022 Fax: +44(0)1425 614794 Email: support@osukl.com Web: www.osukl.com Post: Offshore Dynamics Ltd Unit 10-11 Milton Business Centre Wick Drive, New Milton, Hampshire BH25 6RH Offshore Dynamics Ltd Unit 10-11 Milton Business Centre, Wick Drive, New Milton, Hampshire, BH25 6RH, United Kingdom Tel: +44(0)1425 610022 Fax: +44(0)1425 614794 Email: sales@osukl.com Web: www.osukl.com Copyright 2016 Offshore Dynamics Ltd. All rights reserved. Our policy is one of continuous product improvement so product specifications are subject to change without notice. Offshore Dynamics products are designed to be accurate and reliable. However, they should be used only as aids to vessel monitoring, and not as a replacement for traditional navigation and vessel monitoring techniques. NMEA2000 is a registered trademark of the National Marine Electronics Association. 9 of 12 9 of 12

10 of 12 8 OFFSHORE DYNAMICS PRODUCT MAP