Transmissi (ERCP) visit. by multiple. sites. it. perform the to this safety. time to help. provided by a. Interim. b. Interim. Method: c.

Similar documents
Update on Duodenoscope Related CRE Transmission. Disclosures. Outline 9/2/2016. None

Prevention of Transmission of the Superbug Carbapenem-Resistant Enterobacteriaceae (CRE) during Gastrointestinal Endoscopy

QUALITY ASSURANCE IN ENDOSCOPY

Elevator (Scope Issues) Going Up! Frank Myers, MA, CIC Infection Prevention Clinical Epidemiology UCSD Health

Endoscope Microbial Surveillance Testing Made Easy

Low Temperature Processing. An Update on Guidelines, Standards and Requirements

Is contamination of bronchoscopes really a problem?

Improper Scope Reprocessing is Dangerous and has caused Patient Infections. 1-6

Standards of Infection Prevention in Reprocessing Flexible Gastrointestinal Endoscopes Webinar FAQ

5 Updates to Flexible Endoscope Reprocessing

The Ethylene Oxide Sterilization Association, Inc. Managed by B&C Consortia Management, L.L.C. POSITION STATEMENT. May 20, 2016

Hoe steriel moet het zijn? Prof Dr Margreet C.Vos MD PhD

OLYMPUS Investor Day 2018 Enhancement of Infection Prevention Activities

Dissecting Outbreaks of Multi-resistant Bacteria in Gastrointestinal Endoscopy

ENDOSCOPE REPROCESSING AND INFECTION CONTROL FOR ENDOSCOPY

BIOTECH-GERMANDE ENDOSCOPE REPROCESSING WITH BRUSHLESS CLEANING PROCESS CONDITIONS. Lionel PINEAU PhD

House Keeping. Introduction to ANSI/AAMI ST91:2015: Flexible and Semi-Rigid Endoscope Processing in Health Care Facilities. Welcome!

ANSI/AAMI ST91: 2015

To Create and Deliver the New Standard of Care in Sterile Reprocessing. Investor Presentation 22 February

Summary of Proposed Legislative Provisions

Validation Strategy for an Automated Endoscope Reprocessor

Flexible Endoscopes: The A,B,C s of Monitoring Manual Cleaning Efficacy!

SUBJECT: Detection of Blood (hemoglobin) residue inside the biopsy channel of an endoendoscope

David R. Lichtenstein, MD, FASGE, AGAF, FACG Director of Endoscopy Boston University Medical Center

SUBJECT: Detection of residual organic soils inside various channels of lumened items.

DEFENDO. Sterile Single-use Valves. Procedure

To Create and Deliver the New Standard of Care in Sterile Reprocessing. Investor Presentation 22 February

Recommended Procedure for Sampling Gastrointestinal Flexible Endoscopes

Case 6. Fight Against Nosocomial Infections

ENDORA Endoscope Tracking System

TOTAL SOLUTION FOR ENDOSCOPE REPROCESSING

Endoscopy What s New Up There? Frank Myers, MA, CIC, FAPIC

Understanding ANSI/AAMI ST 91. Flexible and Semi-Rigid Endoscope Reprocessing in Healthcare Facilities

Amanda Billings, MPH, CLS, CIC

OLYMPUS AUG -1 A9 :02

Standards of Infection Prevention in Reprocessing Flexible Gastrointestinal Endoscopes

The Future of Endoscopy. STARTS NOW Sterile Sing le-use Endoscopy

Monitoring Flexible Endoscope Channels to Assure Cleaning

Manner of Assessment Code (check all that apply) & Surveyor Notes. Yes N/A. Yes. Yes N/A N/A. Yes N/A. N/A Yes N/A

DEC TM Video Duodenoscope ED34-i10T2. Lock in. Elevate your care.

A randomized trial of single versus double high-level disinfection of duodenoscopes and linear echoendoscopes using standard automated reprocessing

Irrigation accessories

MDRAO Importance of Bedside & Manual Precleaning CONMED.CA

MDRAO ONLINE COURSE FOURTH EDITION 2018

Irrigation accessories

Cleaning, Disinfection and Sterilization. Basics of Infection Prevention 2-Day Mini-Course October 2016

Testing the Effectiveness of Antiseptics and Disinfectants *

Endoscope Reprocessing: The Need to Shift from HLD to Sterilization

Infection Prevention in Endoscopy, Keeping Patients and Practioners Safe

To Create and Deliver the New Standard of Care in Sterile Reprocessing

Obtaining Manufacturer s IFU: Challenges and Barriers

POLICY FOR THE DECONTAMINATION OF FLEXIBLE ENDOSCOPES

Best Practices for Reprocessing Endoscopes

SUBJECT: Detection of Blood residue inside the biopsy channel of a scope

Instructions for Use: Duodenoscope Sampling Kit

The Human Touches in Endoscope Infection

Responses to Questions for SYSTEM 1E Process Monitoring and Validation Webinar

3/26/2015. This quote sums up the activity going on right now with flexible scopes

CSA Z314 Series Standards Understanding the Standards

Duodenoscope Surveillance Sampling and Culturing Protocols

Ebola Virus Disease Q&As for Nova Scotia Health Care Workers

Winter/spring 2017/18. CEO Lars Marcher

Duodenoscope and Endoscope Reprocessing: Are We Doing Enough to Protect Patients?

St Boniface Research Centre Winnipeg, Manitoba Canada

Controversies in Reprocessing Flexible Endoscopes: High Level Disinfection or Terminal Sterilization????

Residual bioburden in reprocessed side-view endoscopes used for endoscopic retrograde cholangiopancreatography (ERCP)

American Journal of Infection Control

Administrative Policies and Procedures. Cross Reference: Date Issued: 2/14 Date Reviewed: 9/14 Date: Revised: 12/14 Attachment: None Page of 1 of 6

Environmental Surveillance FIDSSA Dr Ben Prinsloo Medical Microbiologist

Human Tissue Intended for Transplantation Skin, corneas, sclera, bone, heart valves, blood vessels, pericardium, tendons, cartilage, fascia

Critical aspects of endoscope decontamination-an overview of endoscope decontamination training for both engineers and users.

Endoscope Decontamination. A Tube in a Hole??

Hygiene Management Guide for Flexible Endoscopes

Human Research Protection Program Guidance for Human Research Determination

FREQUENTLY ASKED QUESTIONS FOR THE ADVANTAGE

Testing the Endoscope Journey vs the Decontamination Process. Wayne Spencer

ADVANTAGE PLUS Pass-Thru

C. difficile & Environmental Decontamination for Long-Term Care

Reprocessing of Single Use Devices (SUDs) MEDEC Regulatory Conference May 9, 2016

THE TERMS VALIDATION AND VERIFICATION ARE FREQUENTLY

*Slides updated to include newer guidelines in February 2016 by Shelby Lassiter, BSN, RN, CPHQ, CIC

Ethicon, Inc All rights reserved. EVOTECH and the EVOTECH logo are registered trademarks owned by Advanced Sterilization Products.

Loaner Program Guidance

Biotech. MicroSan mf DNA Fmarker ENDOSCOPE REPROCESSING VERIFICATION SYSTEM ITALIAN INVESTMENT SHOWCASE TURIN /// APRIL 2018

Monitoring the disinfection of flexible endoscopes using ATP bioluminescence

Reprocessing of Medical Devices: Concerns about Sharps

Endoscope reprocessing: Update on controversial issues

ENDOSCOPY PRACTICE Manual cleaning and Disinfection of flexible endoscopes

Thorny topics related to CRE control

Loaner Programme Guidance

Loaner Programme Guidance

AUTOMATED ENDOSCOPE REPROCESSOR. OER-Pro Easy. Fast. Reliable.

Slide 1. Slide 2. Slide 3

biopsy valves & irrigation accessories

Infection Control Principles and Practice in Endoscopy

endoscope care and accessories featuring our infection control products

Sterile Compounding elearning Course Curriculum 28 lessons with 33 hours of CE. Fundamentals of Sterile Compounding (8 lessons/8 hours CE)

STERILIZATION VALIDATION IN THIS SECTION REPROCESSING VALIDATIONS FOR REUSABLE MEDICAL DEVICES. Radiation Sterilization Validation

EUROPEAN INDUSTRIAL PHARMACISTS GROUP. Guidance on CPD for QUALIFIED PERSONS

Transcription:

Transmissi on of CRE bacteria through Endoscopicc Retrograde Cholangiopancreatography (ERCP) Interim Guidance NOTE: This document was distributed on 3/17/2015. It iss subject to change and may be updated as new evidence or information arises. Please watch communications from ASGE and visit www.asge.org regularly. Patientt safety is a primary concern for ASGE. Transmission of multi drug resistant bacteria, such as carbapenem resistant enterobacteriacae (CRE), through ERCP has been reported by multiple sites across the country. The ASGE contributed to the safety communication issued on February 19, 2015 by the FDA which stated that the complex design of ERCP endoscopes (also called duodenoscopes) may impede effective reprocessing. Further, that meticulously cleaning duodenoscopes prior to high level disinfection should reduce the risk of transmitting infection,, but may not entirely eliminate it. Patients must continue to have access to this important and potentially life saving procedure. ASGE physician members perform the vast majority of ERCPs across the country. Although simple answers to this complex problem are not readily available, we must take steps to ensure ongoing patient safety. The following guidance provides practical steps endoscopy unitt directors can take at this time to help ensure continued patient safety. ASGE s Interim Guidance for all units that use duodenoscopes and other instruments with an elevator mechanism. 1. Review and adopt the guidance provided by the FDA on February 19, 2015. http://www.fda.gov/medicaldevices/safety/alertsandnotices/ucm434871.htmm 2. Review the interim guidance provided by the CDC on March 12, 2015. a. Interim Duodenoscope Surveillance Protocol: http://www.cdc.gov/hai/organisms/ /cre/cre duodenoscope surveillance protocol.html b. Interim Duodenoscope Sampling Method: http://www.cdc.gov/hai/settings/lab/lab duodenoscope sampling.html c. Interim Duodenoscope Culture Method: http://www.cdc.gov/hai/settings/lab/lab duodenoscope culture method.html These CDC resources and related information can be found on this main page: http://www.cdc.gov/hai/outbreaks/index.html 3. Reassess your reprocessing practices to ensure these practices are being done consistently and in accordance with manufacturer s instructions for use. a. Review your training programs and materials. b. Reeducate your frontline staff about the issues specific to cleaning the elevator mechanism. Reeducation should include training sessionss for all personnel involved in reprocessing. Units must ensuree current reprocessing practices strictly adhere to Page 1 of 5

manufacturers guidance and should enlist the assistance of the manufacturer s representative, if necessary. c. Implement a comprehensive quality control program for reprocessing duodenoscopes and echoendoscopes that have an elevator mechanism. This should include observation by responsible education or supervisory staff, with documentation to ensure that all involved staff are performing the steps in reprocessing correctly, plus written procedures for monitoring training and adherence to the program. d. Conduct and document performance and competency assessments for reprocessing now and at regular intervals. Competencies should be assessed at initiation of employee duties and at least annually and anytime a breach is identified or when a major technique or new endoscope or reprocessing equipment is introduced. e. Include documentation of equipment tests, processes and quality monitors used during the reprocessing procedure. 4. All steps in reprocessing remain important and should be performed in accord with the guidance contained in the Multisociety Guideline on Reprocessing Flexible Endoscopes. a. Both the Multisociety Guideline and manufacturer s Instructions For Use (IFU s) provide specific guidance regarding the major elements of bedside prewashing and fluid aspiration until clear, manual washing and brushing with large volumes of water, high level disinfection, drying and appropriate storage. b. For duodenoscopes and EUS endoscopes with elevators, concerted effort should be employed to meticulously clean the elevator mechanism and the recesses surrounding the elevator mechanism by hand, even when using an Automated Endoscope Reprocessor (AER). The elevator should be raised and lowered throughout the manual cleaning process to allow brushing on all sides. 5. Units should document the specific endoscope used for each procedure to facilitate subsequent testing in the event that a patient is found to have a multi drug resistant organism (MDRO), including CRE infections, following ERCP. 6. Endoscopy unit directors should initiate conversations with your local institution s epidemiology or infectious disease staff, quality officers and hospital administration to better understand your local risk and to establish protocols for how you will deal with several clinical scenarios noted below, including suspected cases of post ERCP MDRO/CRE infections. a. Assess the prevalence of CRE in your institution and in your usual patient population. This may help guide your local practices relative to use of patient screening, episodic or universal endoscope culturing, or use of endoscope sterilization. Note at this time, the FDA and CDC have not recommended widespread screening for CRE in hospitalized patients. b. Assess and consider developing your institution s ability to employ methods for avoidance or halting a problem with endoscope transmission beyond expert performance of cleaning and high level disinfection (HLD). This evaluation should include consideration of local availability, staff resources and laboratory expertise. The methods can include: i. Patient screening tools such as anal swab for culture or polymerase chain reaction (PCR) testing for CRE organisms. See CDC CRE Toolkit: http://www.cdc.gov/hai/pdfs/labsettings/klebsiella_or_ecoli.pdf ii. Double cycles of both washing and HLD after each use. Page 2 of 5

iii. Endoscope culturing for intermittent surveillance, case investigation or per procedure application, following the CDC interim guidance for interpretation and response to culture results (see http://www.cdc.gov/hai/organisms/cre/cre duodenoscopesurveillance protocol.html). iv. Low temperature sterilization using ethylene oxide (ETO). ETO might be employed on an ad hoc basis for endoscopes used in MDRO/CRE positive patients, or endoscopes thought to be contaminated for MDRO/CRE. Institutions may choose to develop an intermittent or regular per procedure schedule for ETO sterilization of these instruments. Note that ETO sterilization is not widely available and there are questions about instrument durability and expense using this method. Manufacturer s guidance should be carefully reviewed and followed before employing ETO sterilization on more than occasional ad hoc basis. If there are questions regarding implementation of ETO sterilization, contact the manufacturer s representatives. c. Plan how the institution will respond in the situation of a positive culture for CRE. d. Follow the FDA communication regarding patient notification guidance. 7. If you suspect that problems with reprocessing a duodenoscope have led to infection or to positive results of bacterial surveillance culturing of duodenoscopes then file voluntary reports with both the manufacturer and the FDA Medwatch Safety and Adverse Event Reporting Program (http://www.fda.gov/safety/medwatch/howtoreport/default.htm) Potential Clinical Scenarios and Possible Options for Management Scenario A: At this time, in the absence of known MDRO/CRE exposure or heightened risk At this time, given the uncertainties raised by recent reports, even in the absence of known MDRO/CRE exposure or heightened risks for CRE, consider either: a. One time, post reprocessing surveillance culture of the entire inventory of elevatorequipped endoscopes in the unit. If cultures are employed, endoscopes should be sequestered for a minimum of 48 hours until cultures confirm absence of contamination. Those found to be positive for contamination by pathogenic bacteria should undergo repeat manual cleaning, high level disinfection, and sequestration, or ETO gas sterilization according to manufacturer s guidelines. b. Alternatively, proceed with one time ETO sterilization of the entire inventory of elevator equipped endoscopes, with careful attention to manufacturer s guidelines. Scenario B: For routine daily practice without known heightened CRE risk Currently, in the absence of suspected exposure or known risks, no additional reprocessing practices beyond diligent standard washing and HLD of duodenoscopes are advised by the FDA. Some centers however are employing double cycles of washing and reprocessing for all endoscopes with elevators. Other centers are employing culture and sequestration of these instruments until confirmed clear, or ETO sterilization after each procedure. These options should be reviewed with your hospital infection control staff and administration to determine which approach is most practical and efficacious at your institution. Page 3 of 5

Patients undergoing procedures using duodenoscopes should be informed during the consenting process that there is a risk of patient to patient bacterial transmission associated with the procedure, including uncommon transmission of a multidrug resistant organism. Scenario C: Known MDRO or CRE positive patients The FDA and ASGE have advised, when ERCP is performed in a patient with a known multi drug resistant organism such as CRE, that the duodenoscope should be taken out of service until it has been verified to be free of pathogens before reuse. This would entail high level disinfection followed by either endoscope culture and sequestration until confirmed culture negative at 48 hours or ETO sterilization. This approach could also be implemented for other flexible endoscopes that have an elevator mechanism. Scenario D: Infection (or carrier state) with MDRO or CRE identified in a patient with a history of ERCP in recent months When a patient is newly identified with either a clinical infection or silent carriage of a MDRO/CRE organism, their history should be reviewed to identify potential exposure via endoscopy using an instrument with an elevator (ERCP or EUS) in the prior several months. This interval is poorly defined, but transmission at exposure many months earlier has been described. If exposure via these instruments is a possibility, the following steps should be undertaken: Identify the individual endoscope used in the case and culture it according to one of the standardized culture protocols (see CDC interim culture method: http://www.cdc.gov/hai/settings/lab/lab duodenoscope culture method.html). Sequester the scope out of service for at least 48 hours until a culture for high concern organisms is negative. If the endoscope tests positive for MDRO/CRE, then contact the hospital microbiology and infection control departments to assist with characterization of the cultured organisms to ascertain their equivalence. With your infection control department, identify all patients in whom the endoscope was used, both during an interval prior to the index patient s exposure and subsequent to their exposure up until the time it was taken out of use for culturing. Notification of these patients should be considered, in line with the CDC s guidance, for potential screening via anal swab PCR or culture and for tracking to identify potential illness. Treat the positive CRE contaminated scope with either ETO sterilization according to manufacture guidelines or repeat washing and HLD with sequestration until a repeat culture confirms absence of high concern organisms after at least 48 hours. What about testing endoscopes for ATP or other bioburdens during or immediately after reprocessing? While widely practiced, for this particular issue we currently don t have sufficient data to rely upon routine use of surveillance testing of endoscopes for blood, ATP or other bioburdens. These approaches clearly warrant additional research. Page 4 of 5

Important Contacts and Resources Manufacturers Questions about proper manual cleaning and reprocessing steps and ETO sterilization for duodenoscopes should be addressed directly to the manufacturers: Olympus Technical Assistance Center (TAC) 800/848 9024 option 1 www.olympusamerica.com PENTAX Medical 800/431 5880 (Customer Service) www.pentaxmedical.com FUJIFILM USA 800/385 4633 (Technical Support) 800/872 3854 (Customer Service) www.fujifilmusa.com FDA Direct concerns about a potential case of post ERCP CRE infection to the FDA through the FDA MedWatch site: http://www.fda.gov/safety/medwatch/howtoreport/default.htm. CDC http://www.cdc.gov/hai/outbreaks/index.html ASGE Any questions about the ASGE interim recommendations should be directed to 630 570 6788. Page 5 of 5