Dräger Jaundice Meter JM-105 Jaundice Management

Similar documents
Dräger Jaundice Meter JM-105 Jaundice Management

Movita systems Medical Supply Units

Performance Overview Calibration of your devices according to use instructions, including test gas at our Dräger workshop or directly on-site.

On-site & Shutdown Safety Service Project Coordinator / Project Manager. Basic Information

Dräger MSI Variox-2 Combustion Gas Analysis

On-site & Shutdown Safety Service Safety Equipment Technician. Basic Information

On-site & Shutdown Safety Service Safety Observer

Dräger Fumigation Test Set Dräger-Tubes

Dräger EM200 Multi-channel analyser for measuring flue gases

Dräger DrugTest 5000 Drug Screening Device

Dräger CSE Connect Software

MiraCradle an affordable solution for developing countries

Product Service Remote Service. Basic Information

D D DrägerService Quality products deserve quality service

Dräger DrugTest 5000 Drug Testing Device

Dräger DrugTest 5000 Analysis system for detecting drugs

An Innovative Web Services-Based Architecture for Distributed Systems of Medical Devices

DRÄGER SERVICES. Product Service

DRÄGER SERVICES. On-site Safety Service

On the way to the smart plant Safety technology in the digital age

Drägerware Workshop Software 5000/7000 Drägerware Software

Dräger Mounting System Medical Supply Units

An Innovative Web Services-Based Architecture for Distributed Systems of Medical Devices

Dräger SmartPilot View Software visualisation of anaesthetic levels

D The tools you need, wherever you need them DRÄGER SUPPLY UNITS

MiniWarn. Fits Your Application. Intelligent. Rugged. Flexible. Ergonomic. Easy to use. Multi-Gas Instrument

ACT PLUS SYSTEM Automated Coagulation Timer

Drägerware.Workshop Software 5000/7000 Drägerware Software

Olivia. Dedicated Analytical Solutions

Drägerwerk AG & Co. KGaA Analysts' Meeting Frankfurt, March 12, 2013

Fast. Easy to use. Secure traceability.

Run critical care tests reliably and economically in low-volume settings

protection from butadiene, ethylene oxide, and acrylonitrile

Just Prove it. Spectroquant Prove

Prepared for the unpredictable at any price?

MPM 100 Monitor Product Description Guide

Advanced Immunoassay Testing

AUTOLOG. Autotransfusion System. A simple, yet sophisticated system.

LOTOS. Optical 3D measuring systems K O C O S A U T O M A T I O N [ ENG ]

Just Prove it. Spectroquant Prove

Online data sheet SMC209 C CEMS SOLUTIONS

Recycling Passport. Device: Babyleo TN500 Issued: Producer information. 2. Product identification. page / of 1 / 6

3 PHASE ENERGY ELECTRONIC METERS MKB-363-M INSTRUCTION MANUAL ( M / 00 B

Model BF 720 Incubators Avantgarde.Line with forced convection

autolog Autotransfusion System

LiMCA III Liquid Metal Cleanliness Analyzer

REVISION HISTORY Rev Description Author. Approved by Date A Initial release per ECO Daniel Livingston

The Infitrak Validated Remote Monitoring Platform

This Specification Data Sheet brought to you by: Trinity Blvd. Fort Worth, Texas /

Sealed Tactile Switch

FULLY AUTOMATED ENZYME IMMUNOASSAY ANALYZER AUTOMATED IMMUNOASSAY ANALYZER. Advanced Immunoassay Testing TOSOH BIOSCIENCE

C101-E112. BioSpec-nano. Shimadzu Spectrophotometer for Life Science

Professional flue gas analyzer

SPECIFICATION FOR APPROVAL

Tosoh Result Integrity Multi-Tasking Efficiency

KEY MANAGEMENT SOLUTIONS

SAC850 and SAC950 Sample Changers

Benzene measurement strategy

MATERIAL SPECIFICATION FOR UNINTERRUPTIBLE POWER SUPPLY SYSTEMS FOR LED TRAFFIC SIGNALS

Maintenance in gas detection: How to work efficiently and stay compliant.

Fine particle measuring system

SEMI-CONTINUOUS EMISSION MONITORING SYSTEM

BC Auto Hematology Analyzer. A CUTE 5-part

Cedex Bio Bioprocess Analyzer. Be Confident. Be Assured.

FoodScan for dairy. Dedicated Analytical Solutions

BC Auto Hematology Analyzer. A CUTE 5-part

Model SUP-PH4.0/PH6.0. Supmea SUP-PH4.0 Supmea SUP-PH6.0. Features SUP-PH4.0

ENDOSCOPIC ULTRASOUND CENTRE EU-ME2. Dedicated ultrasound processor with versatile functions.

Magister C24 BECAUSE SMALL IS OUR CHALLENGE! The world s first small fully automated blood group analyser RESEARCH DIAGNOSTICS PHARMACEUTICALS

Digitize Dräger! Employees with a Digital Mindset are the base for our Digital Transformation. Digitize Dräger! Andreas Homolla September 2018

Choose both quality and value

AMOTECH SPECIFICATION MULTILAYER CHIP VARISTOR TYPE : AVLC 5S July 3, 2001 MULTILAYER CHIP VARISTOR SHEET 1/6 DESIGNED CHECKED APPROVED

The new era of digital mobile X-ray imaging. MOBILETT XP Digital. Answers for life.

PITOT TUBE THERMO ANEMOMETER

602VFM MULTIVARIABLE VORTEX MASS FLOWMETER

602VFM MULTIVARIABLE VORTEX MASS FLOWMETER

SINGLE-PHASE TWO-WIRE, DIRECT TYPE, 5(5A) User Manual for SGE-1Y-10100M

Xxxxx Xxxxxx Autoclave Validation Data Logging System

SPECIFIC TECHNICAL CRITERIA

The New Secura : Easy, Reliable Weighing in Regulated Areas

Digital Refractometers. The world's highest standard of technology now available with touch screen. ATAGO taking refractometers to the next level.

meddispense Automated Dispensing Series Medication and Inventory Management that s easy-to-use, easy-to-afford, not easy to be without.

SECURE.GUARD Ultra low temperature freezer

Measure. Print. Done. testo 310. Flue gas analysis the easy way.

RCCS-1 FAQ. The Synthecon Rotary Cell Culture System. 3D Culture Systems for a 3D World RCCS-1. Single Station Rotator Base. Autoclavable Vessel

Single-Use Sensors. TruFluor and TruTorr Excellence in bio-processing measurement

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

HI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter

EPA Compliant Turbidity & Chlorine Meter

WASTEWATER DISINFECTION DESIGNED FOR LARGE-SCALE APPLICATIONS

WASTEWATER DISINFECTION DESIGNED FOR LARGE-SCALE APPLICATIONS

KA 17. Compact Cash Drawer. Product Manual

MEDICATION AND INVENTORY MANAGEMENT

Creating the Improved Standard in Healthcare Sterilization

chemagic STAR New methods for total RNA extraction Standard Solutions Workstation for nucleic acid extraction

EXM500. Online Gas Analyser. Specialist Of UV Spectroscopy

CEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy

OPERATOR S INSTRUCTIONS

MULTIλYZER STx. Flue gas analyzer. BlueLine

Transcription:

Dräger Jaundice Meter JM-105 Jaundice Management The Dräger Jaundice Meter JM-105 gives you consistent quality screening, cost-effectively delivered over the lifetime of the device. As a result, you optimize the efficiency of your jaundice management program, save time and money while delivering an exceptional standard of care. D-86399-2013

02 Dräger Jaundice Meter JM-105 Benefits Effective Jaundice Screening With the Jaundice Meter JM-105 you can accurately identify at-risk infants as young as 35 weeks gestational age. Effective screening can decrease readmission rates and durations of stay. Having dependable results in seconds rather than hours increases patient safety and expedites decision making. New integrated flagging feature helps you keep track of patients in need of special attention and comply with your jaundice management protocols. Easy to use, easy on everyone The JM-105 expands the concept of ease of use. It also means an easier experience for all involved. Since there s no blood draw, there s less stress on fragile newborns and their parents which makes things easier on you. Screening with the JM-105 is fast and easy; simply clean the reusable tip with an alcohol wipe and take your measurement. No fumbling with disposable tips. No recalibration with every baby. Finally, the JM-105 makes it easy for you to get the information you need because it eliminates waiting for laboratory results. And because the device connects to your hospital information system, transferring jaundice screening information to the infant s electronic medical record is effortless and accurate. Simply put, the Dräger Jaundice Meter JM-105 is gentle for the newborn and efficient for you. Improved process and cost efficiency The Jaundice Meter JM-105 streamlines jaundice screening practices by eliminating time-consuming blood draws, scheduling of laboratory work, and processing costs. It improves efficiency by delivering reliable measurements with significantly fewer steps, which frees up more time for direct infant care. The data transfer functionality and barcode scanner help you optimise your screening program and reduce the risk of human error. Because the JM-105 has a reusable probe tip, it requires no disposables. With the volume of screenings performed in nurseries today, the cost of such disposable items can ultimately exceed the initial cost of the device itself. As a result, you save time and money while delivering an exceptional standard of care.

Dräger Jaundice Meter JM-105 03 Related Products Photo-Therapy 4000 With its high reliability and low running costs, the Photo-Therapy 4000 is recommended as a highly effective piece of pediatric equipment for use in the breakdown of high concentrations of bilirubin. PT4000

04 Dräger Jaundice Meter JM-105 Technical Data SPECIFICATIONS DEVICE CLASSIFICATION Protection class per IEC 60601-1 (Jaundice Meter) Protection class per IEC 60601-1 (AC adapter) Ingress of liquids and particulate matter (IEC60601-1) Classification in accordance with EU Directive 93/42/EEC Appendix IX Internally powered ME equipment, Type BF, continuous operation, not AP Class I ME equipment, externally powered, Type BF, continuous operation, not AP IPX0 UMDNS code/gmdn code 16-166/35475 lla ELECTRICAL SPECIFICATIONS Battery Number of measurements (when fully charged) AC adapter Input Output Light source Light source life Sensors PHYSICAL SPECIFICATION Width Depth Height Weight PERFORMANCE SPECIFICATIONS Measurement range DATA TRANSMISSION USB port Internal NiMH 250 9 VDC, 500 ma 100 V ~ to 240 V ~, 50/60 Hz, 11 VA to 18 VA Pulse xenon arc lamp 150,000 measurements Silicon photodiodes 2.20 in 1.77 in 6.61 in 7.16 oz ± 1.5 mg/dl or ± 25.5 μmol/l (> 35 weeks gestation) HL-7 or CSV AMBIENT CONDITIONS DURING OPERATION Temperature Air pressure Altitude range Relative humidity DURING STORAGE AND TRANSPORT Temperature Air pressure Altitude range Relative humidity 10 C to 40 C (50 F to 104 F) 700 hpa to 1,060 hpa -400 m to 3,000 m 30 % to 95 % (without condensation) -10 C to 50 C (14 F to 122 F) 700 hpa to 1,060 hpa -400 m to 3,000 m 30 % to 95 % (without condensation)

Notes Dräger Jaundice Meter JM-105 05

06 Dräger Jaundice Meter JM-105 Notes 90 68 970 15.09-2 Communications & Sales Marketing PP Printed in USA Chlorine-free environmentally compatible Subject to modifications 2015 Drägerwerk AG & Co. KGaA CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee 53 55 23558 Lübeck, Germany www.draeger.com Manufacturer: Draeger Medical Systems, Inc. 3135 Quarry Road Telford, PA 18969-1042, USA USA Draeger Medical, Inc. 3135 Quarry Road Telford, PA 18969-1042, USA Tel +1 215 721 5400 Toll-free +1 800 437 2437 Fax +1 215 723 5935 info.usa@draeger.com CANADA Draeger Medical Canada Inc. 2425 Skymark Avenue, Unit 1 Mississauga, Ontario, L4W 4Y6 Tel +1 905 212 6600 Toll-free +1 866 343 2273 Fax +1 905 212 6601 Canada.support@draeger.com Locate your Regional Sales Representative at: www.draeger.com/contact