DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Primers for Elastomeric and non-elastomeric Sealant

Similar documents
DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric sealant

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric Sealant

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric Sealant

DIVISION 3 - CONCRETE Section Control Joint Sealers

DIVISION 7-THERMAL & MOISTURE PROTECTION Section Cementitious & Reactive Waterproofing

DIVISION 9 - FINISHES Section Coatings

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric sealant

DIVISION 7-THERMAL & MOISTURE PROTECTION Section Cementitious & Reactive Waterproofing

DIVISION 3 CONCRETE Section Concrete Rehabilitation

DIVISION 9 - FINISHES Section SPECIAL COATINGS Section Coating Systems for Steel

DIVISION 9 - FINISHES Section Protective Coatings

DIVISION 3 CONCRETE Section Concrete Rehabilitation

Division 3 - Concrete Section Concrete Rehabilitation

DIVISION 9 FINISHES Section Floor Finishes

DIVISION 3 - CONCRETE Section Concrete Rehabilitation

DIVISION 7 THERMAL AND MOISTURE PROTECTION Section Traffic Coatings

DIVISION 3 - CONCRETE Section Concrete Toppings Section Concrete Resurfacing Section Concrete Rehabilitation

DIVISION 3 - CONCRETE Section Concrete Toppings Concrete Resurfacing Concrete Rehabilitation

DIVISION 3 - CONCRETE Section Concrete Rehabilitation

Part 1 - General. Spec Component Sikadur 32 Hi-Mod. DIVISION 3 -CONCRETE Section Cast-in-Place Concrete Bonding Agents for Concrete

DIVISION 3 CONCRETE Section Concrete Rehabilitation Gravity Feed Crack Repair

Section Shotcrete

A. This specification describes the sealing of vertical joints/cracks with a one-component, gungrade, elastomeric sealants. B.

DIVISION 3 CONCRETE Section Grouts

DIVISION 3 -CONCRETE Section Concrete Rehabilitation Epoxy-Injected Crack Repair

Wood Floor Bonding Systems

Division 3 - Concrete Section Concrete Rehabilitation

Section Fluid Applied Waterproofing

DIVISION 3 -CONCRETE Section Concrete Rehabilitation Epoxy-Injected Crack Repair

Section Polymer Modified Cement Waterproofing

Wood Floor Bonding Systems

DIVISION 3 -CONCRETE Section Concrete Rehabilitation Epoxy-Injected Crack Repair

Section Cementitious underlayment

Wood Floor Bonding Systems

Dist. by: BEST MATERIALS Ph:

Consult Sika Corporation (Industrial Flooring) for assistance in editing this section for the specific application.

PRODUCT DATA SHEET Sikadur 33

ROOF REPLACEMENT AND ALTERATIONS TO WOODSTOCK Barrett Architecture, PC WASTE WATER TREATMENT FACILITY - Woodstock, VT February 28, 2019 SECTION

PRODUCT DATA SHEET Sika FerroGard -908

SECTION Verrazzo Epoxy Mosaic Floor System

PRODUCT DATA SHEET Sikadur 31 CF Normal (formerly Sikadur 731)

SECTION JOINT SEALERS 1.03 THIS SECTION INCLUDES JOINT SEALERS FOR THE FOLLOWING LOCATIONS:

SECTION PENETRATION FIRESTOPPING PART 1- GENERAL PART 2- PRODUCTS 1.1 RELATED DOCUMENTS

RTV6700 Series. RTV6700 Series One-Component, Modified Alkoxy Adhesive Sealants

SECTION JOINT SEALANTS PART 1 - GENERAL 1.01 RELATED DOCUMENTS

Contractors SCS1001. Contractors SCS1000 sealant is available in 4 colors plus. General Glazing: Glass, plastic, channel or stop.

Rust-Oleum Industrial Brands Specification

SECTION Silane Water Repellents. Vexcon

SS4179 primer helps promote adhesion of Momentive Performance Materials sealant to difficult-to-bond plastic substrates including:

Contract Specs Version 1 Project XXX. SECTION xxxx STRENGTHENING OF MASONRY WITH FRCM (FABRIC REINFORCED CEMENTITIOUS MATRIX) PART 1 - GENERAL

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL

This Section includes surface preparation and field application of anti-graffiti coating systems for the following vertical and horizontal surfaces:

SECTION TEXTURED COATINGS. A. Section includes textured coating for tilt-up panels.

ARDEX GUIDE SPECIFICATION ARDEX MRF Moisture-Resistant, Rapid-Drying, Skimcoat Patching Underlayment

Color Clear Black Black Clear Black. Viscosity seconds seconds Water Thin (DIN Cup) (Ford Cup) Water Thin 50 MPa*s

ARDEX GUIDE SPECIFICATION ARDEX FEATHER FINISH Self-Drying, Cement-Based Finish Underlayment

Shower Waterproofing Membrane Under tile and wet area waterproofing membrane.

Contract Specs Version 1 Project XXX. SECTION xxxx STRENGTHENING OF CONCRETE WITH FRCM (FABRIC REINFORCED CEMENTITIOUS MATRIX) PART 1 - GENERAL

1-part polyurethane sealant for building joints

Magna Wall. Elastomeric Coatings (Non-Textured) Product Overview, Instructions, & Data

Adhesion Promoter/Primer 3M Adhesion Promoter AP596

3M Plastic Primer P591. Color Clear Black Black Clear Black Clear. (Ford Cup) Solids (%) VOC (g/l)

SECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)

Rapid Re-coat PU Modified Under-tile waterproof membrane.

3-component epoxy self-smoothing screed

FIVE STAR PRODUCTS, INC.

PROJECT NO August 19, 2014 SENATE CHAMBER MEZZANINE RENOVATION MISSOURI STATE CAPITOL BUILDING SECTION JOINT SEALANTS

SECTION FIRE RESISTIVE JOINT SYSTEMS

Protective Industrial Polymers - USA Manufacturer s Specification February 11, 2015

RTV123. Technical Data Sheet RTV123

Rust-Oleum Industrial Brands Specification

PRODUCT DATA SHEET Sikalastic -641 Lo-VOC

RTV128. Technical Data Sheet

Non-sag, ultra low modulus, neutral cure silicone sealant for pavements

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WARRANTY ON CONCRETE SURFACE COATING

Rust-Oleum Industrial Brands Specification

ARDEX GUIDE SPECIFICATION ARDEX K 60 ARDITEX A Rapid Setting Latex Smoothing and Leveling Compound

Rust-Oleum Industrial Brands Specification

DOWSIL 796 Neutral Silicone

1.04 REFERENCES STANDARDS.1 For reference standards tests & results refer to Manufactures Product Data Sheets

Rust-Oleum Industrial Brands Specification

TECHNICAL DATA SHEET SIKABOND AT METAL GREY 300CC

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER GRAVEL SURFACE BUR

RTV142. Technical Data Sheet

TECHNICAL DATA SHEET SIKADUR 31 CF NORMAL 6KG

80201R StoColor Acryl Flat Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

DIVISION 7 THERMAL AND MOISTURE PROTECTION SECTION PENETRATION FIRESTOPPING

1-part Flexible Sealant for Concrete and Masonry Facades

EPOXY TERRAZZO 1 REV. 8/02

Rust-Oleum Industrial Brands Specification

RTV106. One-Component Acetoxy High Temperature Adhesive Sealant

1-part high performance sealant for flooring

Rust-Oleum Industrial Brands Specification

TECHNICAL DATA SHEET SIKAFLEX PRO-3 SELF LEVELLING

SECTION A. American Society for Testing and Materials (ASTM):

SECTION DETECTABLE GUIDE TACTILES

TECHNICAL DATA SHEET SIKAFLEX FLOOR

CON-DEK ICC-ES ESR-2097 SYSTEM

80212R StoColor Lastic Acrylic-Based, Elastomeric Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

1-part polyurethane pourable self levelling floor joint sealant

Transcription:

Spec Component: SC-099-03/10 Sikaflex Primer 260 Part 1 - General DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section 07900 Joint Sealers Primers for Elastomeric and non-elastomeric Sealant 1.01 Summary A. This specification describes the coating of joints with a one-component, adhesion promoting primer pior to application of a sealant. 1.02 Quality Assurance A. Manufacturing qualifications: The manufacturer of the specified product shall be ISO 9001: 2008 certified and have in existence a recognized ongoing quality assurance program independently audited on a regular basis. B. Contractor qualifications: Contractor shall be qualified in the field of concrete repair and protection with a successful track record of 5 years or more. Contractor shall maintain qualified personnel who have receivced product training by a manufacturer's representative. C. Install materials in accordance with all safety and weather conditions required by manufacturer or as modified by applicable rules and regulations of local, state and federal authorities having jurisdiction. Consult Material Safety Data Sheets for complete handling recommendations. 1.03 Delivery, Storage, and Handling A. All materials must be delivered in original, unopened containers with the manufacturer's name, labels, product identification, and batch numbers. Damaged material must be removed from the site immediately. B. Store all materials off the ground and protect from rain, freezing or excessive heat until ready for use. C. Condition the specified product as recommended by the manufacturer. 1.04 Job Conditions A. Environmental Conditions: Do not apply material if it is raining or snowing or if such conditions appear to be imminent. Minimum application temperature 40ºF (5ºC) and rising. B. Protection: Precautions should be taken to avoid damage to any surface near the work zone due to mixing and handling of the specified sealant. 1.05 Submittals A. Submit two copies of manufacturer's literature, to include: Product Data Sheets, and appropriate Material Safety Data Sheets (MSDS). 1.06 Warranty A. Provide a written warranty from the manufacturer against defects of materials for a period of one (1) year, beginning with date of substantial completion of the project.

Part 2 - Products 2.01 Manufacturers A. Sikaflex Primer 260, as manufactured by Sika Corporation, 201 Polito Avenue, Lyndhurst, NJ 07071 is considered to conform to the requirements of this specification. 2.02 Materials A. Pimer: 2.03 Performance Criteria 1. The primer shall be a one-component, brush, dauber, spray-applied material. It shall be applicable in a horizontal, vertical, and overhead joints. The primer shall cure under the influence of atmospheric moisture A. Properties of the uncured primer: 2. Dry time prior to sealnt installation: >1 <8 hr. 3. Consistency: brush-, or spray-applied liquid 4. Color: clear B. Properties of the cured primer: 1. Promotes adhesion to the following substrates: a. Marble b. Glass c. Lead d. Brass e. Copper f. Aluminum g. Stainless Steel, Galvanized Steel, and Steel h. Zinc i.. Tinplate j. Lexan k. Porcelain l.. Ceramic Tile m.. Siliconized Polyester 2. Service Range: -40F to 170F max 3. The primer shall be capable of being re-applied if necessary. 4. The primer shall be acceptable for use in joints which will be subjected to total water immersion. Note: Tests were performed with material and curing conditions at 71 o -75 o F and 45-55% relative humidity.

Part 3 - Execution 3.01 Surface Preparation A. All substrates must be clean, dry, sound, free of surface contaminants, and free of frost. Remove all traces of the old sealant, dust, laitance, grease, oils, curing compounds, form release agents and foreign particles by mechanical means, i.e. sandblasting, etc., as approved by the engineer. Blow joint free of dust using compressed air line equipped with an oil trap. 3.02 Mixing and Application A. Primer: 1. Shake or stir primer well before using Apply with a brush, dauber, or spray onto the substrate covering the sides of the joint surfaces. 2. If the Sikaflex sealant cannot be installed within 8 hours of priming, reprime the area is necessary 3.03 Cleaning A. The uncured primer can be cleaned from tools and equipment with an approved solvent. The cured primer can only be removed mechanically. B. Leave work area in a neat, clean condition without evidence of spillovers onto adjacent areas.

SC-099 Sikaflex Primer 260 (for metallic, non-metallic and plastic substrates) 1. Shake or stir primer well before using. 2. Brush or daub onto the substrate covering the entire joint surface. 3. Allow primer to dry from 1 to 8 hours prior to installation of sealant. 2 SIKA CORPORATION MAKES NO WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, AS TO THE ACCURACY, COMPLETENESS OR THE CONTENTS OF THESE GUIDE SPECIFICATIONS SIKA SHALL NOT BE RESPONSIBLE UNDER ANY LEGAL THEORY TO ANY THIRD PARTY FOR ANY DIRECT OR CONSEQUENTIAL DAMAGES OF ANY KIND ARISING FROM THE USE OF THESE GUIDE SPECIFICATIONS. Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product's most current Technical Data Sheet, product label and Material Safety Data Sheet which are available at

www.sikaconstruction.com or by calling (201) 933-7452. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instructions for each Sika product as set forth in the current Technical Data Sheet, product label and Material Safety Data Sheet prior to product use.