Attachment A. USG Minimum Design and Construction Requirements for Wood Framed Structures

Similar documents
Building Division Informational Handout

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

SECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.

SECTION PLATE CONNECTED WOOD TRUSSES

Detailing For Wood Shrinkage

FIGURE R502.2 FLOOR CONSTRUCTION

TYPICAL BEARING WALL FRAMING Joints in plates must be offset by 24 min.

WOOD I-JOIST AWARENESS GUIDE

HOLDOWN & STRAP SCHEDULE

DECK PERMIT APPLICATION

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

Formulating a Korea Industrial Standard for light-frame wood construction

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses (MPCWT) Overview Revised 11/17/2016

Typical Deck Details Based on the 2009 International Residential Code (Designed and Printed August 2010)

Residential Deck Guide

Administrative Changes

LPI 56 Technical Guide

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

6-Story Wood Frame Committee

TYPICAL BEARING WALL FRAMING

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses (MPCWT) Design Guide Revised 11/17/2016

CARROLL COUNTY BUREAU OF PERMITS AND INSPECTIONS RESIDENTIAL CODE COMPLIANCE GUIDELINES FOR DECKS

Murphy LVL Limit States Design Guide 2.0 E-LVL 2.2 E-LVL

FACT SHEET #2 DECK INFORMATION

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

PRODUCT: Structural Insulated Panels (SIP) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading

City of Republic Community Development Girder and Header Spans for Exterior Walls

Updated references to SEI/ASCE 7 to the 2016 edition once it is available.

FEMA P-593 STEP-BY STEP PRESCRIPTIVE RETROFIT FOR CRIPPLE WALL BRACING & ANCHORAGE TO FOUNDATION

APPENDIX A1 WIND AND SEISMIC BRACING GUIDELINE FOR ONE AND TWO FAMILY DWELLINGS AND TOWNHOUSES

Jackson Crossing Located in Alexandria, VA. Technical Report 1 Michael Bologna

Mid-Rise Engineering Considerations for Engineered Wood Products

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016

Pulaski County, Virginia Practical Wall Bracing

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

U.S. EDITION RESIDENTIAL CONSTRUCTION DETAILS SAMPLE. A visual guide to construction detailing. Emma Walshaw

Part 1: Vocabulary Select the best answer and write the corresponding letter in the space provided.

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 Virginia Residential Code

Framing Methods Structural Components

Strong-Drive SDWS TIMBER Screw

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

THE ASHTON PERSPECTIVE VIEW

10 EXTREME BASEMENT PANELS

Garage/Accessory Structures

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

TP: 89'-0" BP: 86'-6 1/4" 2'-0" Typ TP: 89'-0" BP: 86'-6 1/4" 2'-0" Typ S201 TW: 89'-0" TF: 86'-0" S201 TW: 87'-11 1/4" S201 TF: 86'-10 1/4" S201

4 EXTREME FOUNDATION PANELS

CHAPTER 6 TYPES OF CONSTRUCTION

Building Guide. Building Guide. Colorado Chapter of the International Code Council. Single Family Residential Patio Covers & Carports

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

Left Elevation. Front Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,842. Scale : 1/4" = 1'

Typical Deck Details. Albemarle County, Virginia. Based on the 2012 Virginia Residential Code

CHAPTER 5 FLOORS SECTION R501

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

BROADSPAN. I-Joist Design Brochure. Design properties for I-joist applications in the U.S. for residential floor systems. I-Joist Design Brochure

THE FLORIDA BUILDING CODE

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

LIGHT-GAUGE PANELIZED WALL SYSTEMS. Michael Waggoner Mark Schroeder

Elevation "L" ASTOR II DESIGN CRITERIA: 2012 International Residential Code with Georgia Amendments

WFCM 120 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

Elevations. Front Elevation. Left Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,647.

BEARING METAL STUD FRAMING

SECTION R614 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION

2003 International Residential Building Code

Elevation "L" CHELSEA II DESIGN CRITERIA: 2012 International Residential Code with Georgia Amendments

Elevations. Front Elevation. Left Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,647.

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

LVL Product Guide 2.0E LVL 1.5E LVL

Modular Wood Framing Goes Vertical

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

130 MPH EXPOSURE B WFCM GUIDE. Guide to Wood Frame Construction in High Wind Areas for One- and Two-Family Dwellings 2015 EDITION

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 International Residential Code

Structural Inspection

SECTION COLD-FORMED METAL FRAMING

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

SECTION COLD-FORMED METAL FRAMING

Lateral load basics Code acceptance of Standard. Standard Overview 2008 Wind & Seismic Standard. Wind. Wind Load Path. IBC Section 1604.

Featuring Selection and Installation Information for Lateral Wind Loads

WALL CONSTRUCTION CHAPTER 6

WFCM 90 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 110 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 100 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

Building Guide. olorado Chapter of the International Conference of Building Officials. Lancaster County Building Department

Danielle Shetler - Structural option Courtyard by Marriott Lancaster, PA

Technical Data for. Headers. and Beams

Manufactured decking (composite) may be used when approved by the building department

#G445 Plans, 48'x28' x 10' detached garage with bonus room By SDS-CAD Specialized Design Systems

Building Envelope

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

Campbell County Building Inspection Division Guideline to 2018 IRC Residential Construction for Decks

assembly an open space between the roof and ceiling of a building attic balloon frame a joist constructed of steel with bars in the verticle web space

Transcription:

Attachment A USG Minimum Design and Construction Requirements for Wood Framed Structures 1. General Design Criteria 1.1. Per Adopted Georgia State Minimum Standard Building Code 1.2. Minimum Live Loads Dormitory rooms and corridors serving them: Live Load: 40 PSF Partitions: 15 PSF (Including demising walls) Public rooms and corridors serving them: Live Load: 100 PSF Storage rooms, mechanical rooms and kitchens: Live Load: 125 PSF 1.3. Minimum Superimposed Dead Loads (Self weight additional) Typical unless noted: Dead Load: 5 PSF Above Kitchens and Mechanical Rooms: Dead Load: 15 PSF minimum Equipment: In addition to the above load, account for the weight of all equipment (mechanical, electrical and plumbing units; including piping, piping risers, kitchen hoods, elevators, exhaust ducts, etc. 1.4. Account for anticipated future build-out or occupancy changes. 1.5. Deflection Criteria: Roofs: Live Load: L/240 (1 max.) Total Load: L/180 Floors: Live Load: L/480 (0.5 max.) Total Load: L/240

Page 2 1.6. Wood Shrinkage Per IBC Section 2304.3.3, for structures with wooden walls supporting more than two floors and a roof, prepare and submit calculations and details, signed and sealed by a GA Professional Engineer, indicating that shrinkage of wood framing will not have adverse affects on the following: Equipment (including piping risers, elevator guiderails, etc.). Architectural finishes (including interior walls, doors and finishes). Exterior walls doors, windows and veneers. Structural levelness (including roof drainage systems). Provide details to accommodate computed differential movements. For brick veneer, details should accommodate brick veneer expansion as well as wood shrinkage. 2. Materials/Specifications 2.1. Exterior and Loadbearing Wall Framing: 2.2. Floor Framing: Studs: Min. 2x6 So. Pine or SPF, No. 2., 19% max. moisture content @ 24 o/c max. Plates: Min. So. Pine or SPF, No. 2, 15% max. moisture content. Provide double top plates to support floor & roof trusses. Handling and storage of material shall be such that these moisture contents are not exceeded at the time of installation. Floor Joists: Wooden trusses or engineered wood products @ 24 o/c max. Dimension lumber is allowed for special framing conditions. Rim Bands and Blocking at Loadbearing Walls: Use of low shrinkage engineered wood rim bands and loadbearing blocking (such as OSB or LSL products) to minimize cross-grain shrinkage. LVL products shall not be assumed to minimize cross grain shrinkage.

Page 3 2.3. Roof Framing: 2.4. Sheathing: Wooden trusses or engineered wood products @ 24 o/c max. Dimension lumber is allowed for special conditions. Floor Sheathing: APA Rated Sheathing (Plywood or OSB), min. ¾ T&G, Exposure 1. Place sheathing with face grain perpendicular to the supporting framing. Splice panels only over supporting joists. Provide blocking at non-t&g joints perpendicular to supporting joists. All floor sheathing shall be glued and screwed to all supporting framing members. Water resistant floor sheathing (i.e. Advantech) is recommended to minimize warping, cupping or swelling. Roof Sheathing: APA Rated Sheathing (Plywood or OSB), min. 5/8, Exposure 1. Place sheathing with face grain perpendicular to the supporting framing. 2.5. Masonry Veneer Anchors: Secure directly to framing (not sheathing) with stainless steel screws and in accordance with manufacturer s recommendations (nails not allowed). 2.6. All wooden framing including beams, studs, plates and blocking that are in contact with concrete or masonry or that are exposed to weather or water shall be pressure treated (PT) lumber. 2.7. All connectors and hangers shall be galvanized. 3. Structural Layout 3.1. Design stacking unit demising walls as loadbearing elements wherever possible. Stacking demising walls will act as loadbearing elements whether or not they are assumed to be. Not accounting for this may result in unintended structural behavior and distress. Where nonloadbearing demising walls are unavoidable, provide connections that allow vertical slip between the wall top plate and the floor or roof structure above and detail finishes accordingly.

Page 4 3.2. Avoid offsetting loadbearing walls between levels. If stacking of loadbearing wall is not feasible, provide LVL, steel or similar heavy structural member instead of relying on typical floor framing for support. 3.3. Minimize cross grain shrinkage within floor systems at loadbearing elements. Use low shrinkage rim bands and loadbearing blocking. 3.4. For loadbearing walls, avoid offsetting studs between floors. Where more studs are required at a lower story than at an upper story, it is recommended to have lower floor studs directly beneath upper floor studs plus additional lower floor studs. It is recommended to match spacing of studs and supported floor members. At special conditions where offsetting studs must be used, explicitly design wall top plates to transfer load between studs above and below without excessive stress or deflection. 3.5. Where floor joists or trusses run parallel to a girder, loadbearing wall, or other stiff structural element, place the first joist or truss at 6 max. from the adjacent stiff element (in order to minimize differential displacement). 3.6. Avoid spread or strip footing founded on fill wherever possible. Where unavoidable, limit soil settlement to ½ max. Step strip footings at 1V : 2H max. at grade transitions. 4. Structural Design 4.1. Account for differential vertical movement at intersections of loadbearing and non-loadbearing walls. 4.2. Account for differential vertical movement at interface of steel, masonry and wood elements. 4.3. Design wall-opening headers to support load from all levels above unless openings stack exactly from floor to floor. 4.4. Design for the transfer of shearwall lateral loads through the floor system. Indicate required blocking, nailing and connectors to provide a continuous load path. 4.5. Trusses and their connection design calculations and shop drawings shall be prepared by registered Specialty Engineer and shall be submitted for approval.

Page 5 5. Structural Drawings 5.1. Draw structural framing plans at 1/8 = 1-0 min 5.2. Show all members on main framing plan. Avoid reference to subframing plans as much as possible. 5.3. Indicate all non-typical joist hangers and connectors on framing plans. 5.4. Clearly indicate all required vertical loadbearing walls and columns on framing plans. Show loadbearing elements below the floor plane vs. above. 5.5. Clearly indicate shearwalls and lateral load elements on framing plans, including locations of holdowns. Distinguish between shearwalls and gravity walls. Provide full height shearwall elevations keyed to framing plans indicating sheathing, nailing, stud placement, blocking, chords, holdowns, etc. 5.6. Account for and describe special conditions, such as transfer beams where loadbearing elements do not align above and below a floor. 6. Construction Requirements 6.1. Adhere to the following finish installation sequence requirements: Delay installation of masonry veneer and other brittle finishes as long as possible to minimize differential movement between them and the wooden wall structure. In any case, do not begin installation until the structure in the affected area has been topped out. Wherever possible, install gypsum board from the top story down, after the structure has been topped out. Provide wall blocking to ensure lateral stability of loadbearing wall studs prior to gypsum board installation. As a minimum, provide one line of continuous blocking at wall mid-height for all loadbearing walls. 6.2. Store all wood members a minimum of 12 above grade and keep continuously covered to prevent exposure to rain and water. Higher than specified moisture content at time of installation shall be cause for rejection.

Page 6 7. Inspection Requirements 7.1. The following inspections are required in addition to those required by Chapter 17 of the IBC, and shall be added to the Statement of Special Inspections for the project: Wood Framing and Connections: Continuous inspection by a Georgia Professional Engineer to verify compliance with Drawings, Specifications, Shop Drawings, manufacturer s requirements, and the requirements of this document, including the following: Grade of lumber, manufactured wood products and sheathing. Details of wood framing including member types, sizes, spacing, blocking, bridging and bearing. Wood connections including nailing, bolting, tie downs, hangers and anchors. Diaphragm sheathing thickness, fastener size and spacing. Metal-plate-connected wood trusses. Temporary and permanent restraint/bracing in accordance with the approved truss submittal package. Masonry Veneer Anchors: Continuous inspection to verify compliance with Drawings, Specifications and manufacturer s requirements. Foundation subgrade: Hand auger tests and a dynamic cone penetrometer tests at each spread footing and at 20 ft. o/c at each strip footings in order to verify that fill soils conform to geotechnical report requirements and limit settlement to ½ maximum at footings on fill. Moisture Content: Periodic inspection of installed studs, plates, rim bands and blocking to verify that moisture content is less than specified value. 7.2. As used above, continuous inspection means daily observation during the performance of the indicated construction activity before the work is covered by finishes (gypsum board, sheathing, veneers, gyp-crete, etc.)

Page 7 8. Typical Details (See Appendix A ) Typical Plumbing Riser Requirements Typical Floor Level Compression Joint for Brittle Finishes Typical Detail at Window Head in Brick Veneer Typical Detail at Window Sill in Brick Veneer 9. Technical References USDA Wood Handbook http://www.fpl.fs.fed.us/documnts/fplgtr/fpl_gtr190.pdf Accommodating Movement in High-Rise Wood Frame Building Construction http://www.structuremag.org/article.aspx?articleid=1269 BIA TN-18: Volume Changes - Analysis and Effects of Movement http://www.gobrick.com/portals/25/docs/technical notes/tn18.pdf American Wood Council http://www.awc.org/index.php

Page 8 Appendix A Typical Details 1. Typical Plumbing Riser Requirements 2. Typical Floor Level Compression Joint for Brittle Finishes 3. Typical Detail at Window Head in Brick Veneer 4. Typical Detail at Window Sill in Brick Veneer