Level III Chapter 1 Worksheet

Similar documents
READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X Adopt Entire Chapter as amended (amended sections listed below) X X X X X X

GRAYWATER SYSTEMS FOR RESIDENTIAL BUILDINGS

GRAY WATER SYSTEMS FOR RESIDENTIAL BUILDINGS

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

1 Exam Prep Florida Building Code- Plumbing, 2014 Tabs and Highlights

Copyright 2017, ProVent Systems Inc., All Rights Reserved

6857 INTERNET TEST PLMB30

GRAYWATER STANDARD PLAN For Simple Residential System

Table of Contents Rules Concerning Uniform Plumbing Code

Amendments to the 2012 International Plumbing Code

International Plumbing Code 2006 Study Guide

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents

3. Sanitary Plumbing Single Stack System

Ontario s 2012 Building Code Division B, Part 7 Ontario Regulation 332/12

Typical Finished Basement Details

2012 International Plumbing Code. Exhibit D

Review the section Preparing for work, then complete the following.

Chapter 2 Definitions. Chapter 2 Definitions COMBINATION WASTE AND VENT SYSTEM.

STORM DRAINAGE CHAPTER 11

REQUEST FOR TECHNICAL CHANGE

STORM DRAINAGE CHAPTER 11

A. This Section includes the following sanitary drainage piping specialties:

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

Amendments to the 2006 International Plumbing Code

Fairfax County, Virginia

Holding tank Interceptor Leaching Leaching bed Leaching bed fill Loading rate Pail privy Percolation time Portable privy Potable Pressurized

2015 IPC Design, Installation and Inspection Principles IPC Design, Installation and Inspection Principles

Charter Township of Raisin

NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING

SUPPLEMENTAL 2011 PLUMBING CORRECTION SHEET FOR HIGH-RISES

SECTION PLUMBING PIPING SYSTEM

3.1 General Requirements:

2006 International Plumbing Code

Water Service Inspection Checklist

Chapter DRAFT - PLUMBING CODE* (Current working draft of Juneau Building Code Advisory Committee 10/24/ unadopted)

PREPARING RESIDENTIAL PROPERTY FORTHE HOUSING HABITABILITY INSPECTION

REGISTRATION EXAMINATION, november 2015 LICENSED PLUMBER. Time allowed THREE hours

City of West Allis W Greenfield Ave Room 222 West Allis, WI Phone: (414) Fax: (414) Plumbing Inspector: Mike Romens

Recommended Amendments to the 2015 International Plumbing Code North Central Texas Council of Governments Region

SOUTHERN NEVADA PROPOSED AMENDMENTS TO THE 2012 UNIFORM PLUMBING CODE PLUMBING/MECHANICAL CODE COMMITTEE SEPTEMBER 07, 2012

Common Plan Review Rejection Reasons

for plumbing regulations.

PORT OF SAN FRANCISCO PLUMBING CODE. Based on the 2010 California Plumbing Codes

The following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors.

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

PLAN CHECK CORRECTION SHEET FOR PLUMBING SYSTEMS 2017 LAPC

Common Plan Review Rejection Reasons

GRAY WATER RECYCLING SYSTEMS

Municipal Code of Chicago CHAPTER PLUMBING* Article 1. Administration Department of Water Management requirements.

SOUTHERN NEVADA AMENDMENTS TO THE 2018 UNIFORM PLUMBING CODE

Pulaski County, Virginia

SANITARY DRAINAGE CHAPTER 30

Errata for the 2003 Uniform Plumbing Code Study Guide (5th Printing)

Accessible Toilet and Bathing Rooms

GRAYWATER SYSTEMS FOR RESIDENTIAL BUILDINGS

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.

2015 UPC Chapter 2 Definitions Part 1 RV 11/8/16

PORT OF SAN FRANCISCO PLUMBING CODE. Based on the 2016 California Plumbing Code

CHAPTER 2 DEFINITIONS CHAPTER 3 GENERAL REGULATIONS

Chapter 3: General Regulations

REQUEST FOR DEVIATION WATER AND WASTEWATER SYSTEM STANDARD SPECIFICATIONS

1 Exam Prep Chapter 64E -6 Questions and Answers

ICC Plumbing Update. St Louis Missouri ASPE Chapter March 5, 2013

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents

APPLICATION FOR GRAYWATER IRRIGATION SYSTEM PERMIT SIMPLE RESIDENTIAL GRAVITY SYSTEMS, NO STORAGE

Septic Permit Application

A. Provide floor drains in all restrooms placed a minimum of 7 from back of wet wall, janitor closets, and mechanical rooms.

TOWNSHIP OF UPPER DEERFIELD

CHAPTER 7 SANITARY DRAINAGE SYSTEMS

City of Muskogee Pollution Control Department POLICY STATEMENT FOR GREASE AND OIL CONTROL

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

Proposed Revisions ******

CITY OF ANDERSON BUILDING AND CODES 601 South Main Street

Application For Graywater Irrigation System Permit

CONTINUING EDUCATION UPC Definitions Code Course. 4 hours Course # ID09143 (CODE) PO Box Spokane, WA

International Plumbing Code (IPC), 2012 Edition with 2014 Georgia State Amendments

WATER & SEWER SERVICES

CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE CHAPTER 11 - STORM DRAINAGE

DEVICES AND LUMINAIRES

Student Services & Classroom Addition. A. This Section includes the following sanitary drainage piping specialties:

Union County Vocational - Technical Schools Scotch Plains, New Jersey. A. This Section includes the following sanitary drainage piping specialties:

County of Yolo Development Services Building Inspection Division

City of Rohnert Park When Permits are Required

CONTINUED ON FOLLOWING PAGE

DIVISION 22 PLUMBING SECTION INTERIOR SANITARY WASTE AND VENT PIPING SYSTEM

RENTAL INSPECTION CHECKLIST. Helpful Definitions: Egress: the free and unobstructed access to the exterior of a habitable space.

Advanced Water Supply and Distribution

Section 8.7 Building Storm Drainage Systems

CRAFTSMAN EXAMINATION, NOVEMBER 2008 PLUMBING ANSWER SCHEDULE

Typical Finished Basement Details

COMMERCIAL PROJECT PLAN REVIEW PROCESS

2018 IRC Sections R303 through R310 Building Planning II

CHAPTER 15 PLUMBING CODE

CHAPTER 11 MOBILE HOME PARKS

AN ORDINANCE TO ADOPT A PLUMBING CODE FOR THE CITY OF MOBILE, ALABAMA BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF MOBILE, ALABAMA, AS FOLLOWS:

DEVICES AND LUMINAIRES

SANITARY SEWER BACKUP

CHAPTER 11 STORM DRAINAGE Subsoil drains shall be piped to a storm Where it is not possible to convey the

City of Edwardsville Safe Housing Program Rental Property Registration and Inspection. Rental Property Guide

Uniform Construction Code

Transcription:

Chapter 1 Worksheet 1. For applicability requirements of the Plumbing Code, refer to: a. Building Code b. Administration and Enforcement Code c. Plumbing Code d. Residential Code 2. The provisions of the Plumbing Code shall apply to: a. every plumbing installation b. alterations and repairs c. replacements d. all of the above 3. The provisions of the Plumbing Code shall NOT apply to: a. Gas-fired water heaters b. Water heater venting systems c. Fuel gas piping d. All of the above 2012 NC Plumbing Code Level 3 Page 1 of 14 Revised: 10/2016

Chapter 1 Answer Key 1. C 102 2. D 102 3. D 101.2 2012 NC Plumbing Code Level 3 Page 2 of 14 Revised: 10/2016

Chapter 8 Worksheet 1. A restaurant has an indirect waste line discharging into a floor drain located in a closet and an additional indirect waste is discharged into a floor drain located in a toilet room. Which of the following makes this a code violation? a. waste receptors shall not be installed in a closet b. waste receptors shall not be installed in a toilet room c. Both A and B d. None of the above 2. What is the minimum air gap required by the code for a 2 inch drain? a. 2 b. 3 c. 4 d. 6 3. Indirect waste pipe exceeding inches horizontal/developed or inches in total developed lengths shall be trapped. a. 18, 24 b. 24, 48 c. 36, 48 d. 30, 54 4. The outlet of the laundry tray shall be a maximum horizontal distance of inches from the standpipe trap. a. 18 b. 24 c. 30 d. 42 2012 NC Plumbing Code Level 3 Page 3 of 14 Revised: 10/2016

5. The vertical standpipe inlet for a washing machine drain to the trap weir shall be a minimum of inches? a. 24 b. 18 c. 12 d. 36 2012 NC Plumbing Code Level 3 Page 4 of 14 Revised: 10/2016

Chapter 8 Answer Key 1. C 802.3 2. C 802.2.1 3. B 802.2 4. C 802.4 5. B 802.4 2012 NC Plumbing Code Level 3 Page 5 of 14 Revised: 10/2016

Chapter 9 Worksheet 1. On the lower floors of multi- story buildings, when wet venting, with 7 bathtubs, what size vent stack is required? a. 2 b. 2½ c. 3 d. 4 2. With vertical combination waste and wet venting, a 4 diameter stack with a maximum length of 100 would be required for 6 public use water closets. a. True b. False 3. A 4 diameter drain having 300 fixture units, 60 foot long vent, requires a vent stack of. a. 2 b. 2½ c. 3 d. 4 4. Can the waste pipe from one or two lavatories be used as a wet vent for one or two bathtubs or shower on the top floor of a multi-story building? a. Yes b. No 5. A domestic bathtub has a 1½ p-trap and a 2 waste arm. What is the maximum length of this trap arm to its vent terminal? a. 5 feet b. 8 feet c. 6 feet d. 10 feet 2012 NC Plumbing Code Level 3 Page 6 of 14 Revised: 10/2016

6. A multi-story apartment building is using wet vent tubs and shower on all floors. there are 6 tubs and 5 showers. The minimum size vent stack is? a. 3 inches b. 2 inches c. 2½ inches d. 4 inches 7. A 4 inch soil stack has 250 dfu connected to it. This stack is vented with a 3 stack vent. What would be the maximum permitted length of this stack vent? a. 170 feet b. 260 feet c. 70 feet d. 250 feet 8. A 4 soil stack receives the discharge of 180 dfu. This soil stack is stack vented to the open air, but this vent is not the main vent for the building. The stack vent portion is 36 feet, what is its minimum size? a. 1½ inches b. 2 inches c. 2½ inches d. 3 inches 9. A 5 inch horizontal branch is required to have a relief vent. The relief vent is serving as a relief for 96 dfu. The developed length of this vent is 24 feet. What is the minimum allowed size of this relief vent? a. 1½ inches b. 2 inches c. 2½ inches d. 3 inches 2012 NC Plumbing Code Level 3 Page 7 of 14 Revised: 10/2016

Chapter 9 Answer Key 1. C T 909.4 2. B 910.2 3. C T 916.1 4. B 909.4 5. C T 906.1 6. D T 909.4 7. A T 916.1 8. C T 916.1 9. C T 916.1 2012 NC Plumbing Code Level 3 Page 8 of 14 Revised: 10/2016

Chapter 10 Worksheet 1. Which of the following is an approved trap? a. S-trap b. Bell-trap c. P-trap d. Crown-trap 2. Sand and similar interceptors for heavy solids shall have a water seal of not less than inches. a. 1 b. 2 c. 4 d. 6 3. Each interceptor shall be. a. properly vented b. at least 3 inches in diameter c. galvanized d. designed to become air bound 4. Traps shall have a water seal of not more than inches and not less than inches. a. 3 & 2 b. 4 & 1 c. 2 & 4 d. 4 & 2 5. An intercepting device shall prevent the passage of solids of inch and larger. a. ½ b. ¼ c. ¾ d. 1 2012 NC Plumbing Code Level 3 Page 9 of 14 Revised: 10/2016

6. Interceptors shall be maintained in efficient operating condition by removal of accumulated grease. a. annual b. semi-annual c. monthly d. periodic 7. A combination plumbing fixture may be installed on one trap, if one compartment is not more than inches deeper than the other and the waste outlets are not more than inches apart. a. 6 & 30 b. 12 & 24 c. 6 & 18 d. 4 & 24 2012 NC Plumbing Code Level 3 Page 10 of 14 Revised: 10/2016

Chapter 10 Answer Key 1. C 1002.3 2. D 1003.5 3. A 1003.9 4. D 1002.4 5. A 1003.6 6. D 1003.10 7. A 1002.1 #2 2012 NC Plumbing Code Level 3 Page 11 of 14 Revised: 10/2016

Chapter 11 Worksheet 1. When roof drains are provided they shall have strainers extending not less than inches above the surface of the roof immediately adjacent to the roof drain. a. 3 b. 4 c. 5 d. 6 2. What is the maximum projected roof area that a 4 inch vertical leader can handle with a 4 inches per hour rainfall? a. 18,400 square feet b. 9,200 square feet c. 6,130 square feet d. 4,600 square feet 3. A roof has an area of 4,600 square feet. What is the minimum size horizontal drain required if it has 1/4 per foot fall and 4 inches per hour rainfall? a. 4 b. 5 c. 6 d. 8 4. Secondary roof drain systems are sized according to what rain flow rate? a. 100 year, 15 minute precipitation b. 100 year, 60 minute precipitation c. 60 year, 15 minute precipitation d. 60 year, 60 minute precipitation 5. A receptacle designed to collect surface or rain water from an open area is a a. Conductor b. Leader c. Backwater device d. Area drain 2012 NC Plumbing Code Level 3 Page 12 of 14 Revised: 10/2016

6. Which of the following shall not be connected to a storm drain? a. Roof leaders b. Floor drains c. Area drains d. Roof conductors 2012 NC Plumbing Code Level 3 Page 13 of 14 Revised: 10/2016

Chapter 11 Answer Key 1. B 1105.1 2. D 1106.2 3. B 1106.3 4. A F 1106.1.A 5. D 202 6. B 1104.3 2012 NC Plumbing Code Level 3 Page 14 of 14 Revised: 10/2016