MATERIAL SPECIFICATION FOR EXTRUDED EXPANDED POLYSTYRENE PAVEMENT INSULATION

Similar documents
MATERIAL SPECIFICATION FOR EXTRUDED EXPANDED POLYSTYRENE PAVEMENT INSULATION

MATERIAL SPECIFICATION FOR SMOOTH WALLED STEEL PIPE

MATERIAL SPECIFICATION FOR PRESSURE POLYETHYLENE PIPE PRODUCTS

MATERIAL SPECIFICATION FOR CORRUGATED STEEL PIPE (CSP) PRODUCTS

CONSTRUCTION SPECIFICATION FOR IN-PLACE FULL DEPTH RECLAMATION OF BITUMINOUS PAVEMENT AND UNDERLYING GRANULAR

MATERIAL SPECIFICATION FOR SMOOTH WALLED STEEL PIPE

ONTARIO PROVINCIAL STANDARD SPECIFICATION

CONSTRUCTION SPECIFICATION FOR IN-PLACE FULL DEPTH RECLAMATION OF BITUMINOUS PAVEMENT AND UNDERLYING GRANULAR

CONSTRUCTION SPECIFICATION FOR IN-PLACE FULL DEPTH RECLAMATION OF BITUMINOUS PAVEMENT AND UNDERLYING GRANULAR

CONSTRUCTION SPECIFICATION FOR THE GRINDING OF CENTRELINE AND SHOULDER RUMBLE STRIPS IN ASPHALT

CONSTRUCTION SPECIFICATION FOR SUPPORT SYSTEMS

TABLE OF CONTENTS. Use of this specification or any other specification shall be according to the Contract Documents.

MATERIAL SPECIFICATION FOR NON-PRESSURE POLYVINYL CHLORIDE PIPE PRODUCTS

MATERIAL SPECIFICATION FOR NON-PRESSURE POLYETHYLENE (PE) PLASTIC PIPE PRODUCTS

MATERIAL SPECIFICATION FOR CIRCULAR AND ELLIPTICAL CONCRETE PIPE

CONSTRUCTION SPECIFICATION FOR CLEARING, CLOSE CUT CLEARING, GRUBBING, AND REMOVAL OF SURFACE AND PILED BOULDERS

CONSTRUCTION SPECIFICATION FOR TAU II SYSTEM

EXPANDED POLYSTYRENE (EPS GEOFOAM) EMBANKMENT DIVISION 31 EARTHWORK

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF SECTIONAL STEEL HIGH MAST LIGHTING POLES

MATERIAL SPECIFICATION FOR NON-PRESSURE POLYETHYLENE (PE) PLASTIC PIPE PRODUCTS

CONSTRUCTION SPECIFICATION FOR RUBBLIZING CONCRETE PAVEMENT AND CONCRETE BASE

MATERIAL SPECIFICATION FOR CIRCULAR AND ELLIPTICAL CONCRETE PIPE

CONSTRUCTION SPECIFICATION FOR GUIDE RAIL END TREATMENT - EXTRUDER TERMINAL SYSTEM

CONSTRUCTION SPECIFICATION FOR TRENCHING, BACKFILLING, AND COMPACTING

CONSTRUCTION SPECIFICATION FOR TRAFFIC CONTROL SIGNING

MATERIAL SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS

CONSTRUCTION SPECIFICATION FOR TRAFFIC CONTROL SIGNING

CONSTRUCTION SPECIFICATION FOR EMBEDDED WORK IN STRUCTURES FOR ELECTRICAL SYSTEMS

CONSTRUCTION SPECIFICATION FOR EARTH BORROW

MATERIAL SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS

CONSTRUCTION SPECIFICATION FOR BORROW

MATERIAL SPECIFICATION FOR ADMIXTURES FOR CONCRETE

MATERIAL SPECIFICATION FOR BEARINGS - ELASTOMERIC PLAIN AND STEEL LAMINATED

CONSTRUCTION SPECIFICATION FOR TRENCHING, BACKFILLING, AND COMPACTING

CONSTRUCTION SPECIFICATION FOR TRENCHING, BACKFILLING, AND COMPACTING

MATERIAL SPECIFICATION FOR BEARINGS - ELASTOMERIC PLAIN AND STEEL LAMINATED

MATERIAL SPECIFICATION FOR ADMIXTURES FOR CONCRETE

CONSTRUCTION SPECIFICATION FOR STOCKPILING OF PATCHING MATERIALS AND PATCHING OF ASPHALT PAVEMENT

CONSTRUCTION SPECIFICATION FOR REMOVAL OF ELECTRICAL EQUIPMENT AND MATERIALS

CONSTRUCTION SPECIFICATION FOR BORROW

MATERIAL SPECIFICATION FOR NON-PRESSURE POLYETHYLENE PLASTIC PIPE PRODUCTS

MATERIAL SPECIFICATION FOR EXTRA LOW-VOLTAGE CABLE

Construction Specification for Trenching, Backfilling and Compacting

CONSTRUCTION SPECIFICATION FOR PIPELINE AND UTILITY INSTALLATION BY JACKING AND BORING

CONSTRUCTION SPECIFICATION FOR BORROW

CONSTRUCTION SPECIFICATION FOR EXPANDED METAL ANTI-GLARE SCREEN

CONSTRUCTION SPECIFICATION FOR GRANULAR SEALING

CONSTRUCTION SPECIFICATION FOR INERTIAL MODULE SYSTEM

MATERIAL SPECIFICATION FOR SPUN CONCRETE POLES

MATERIAL SPECIFICATION FOR CALCIUM CHLORIDE FLAKE AND CALCIUM CHLORIDE SOLUTION

MATERIAL SPECIFICATION FOR CIRCULAR AND ELLIPTICAL CONCRETE PIPE

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF POWER SUPPLY EQUIPMENT

Amendment to OPSS 416 (Nov 2013) Construction Specification for Pipeline and Utility Installation by Jacking and Boring

CONSTRUCTION SPECIFICATION FOR CONCRETE FOOTINGS AND MAINTENANCE PLATFORMS FOR HIGH MAST LIGHTING POLES

CONSTRUCTION SPECIFICATION FOR OPEN GRADED DRAINAGE LAYER

CONSTRUCTION SPECIFICATION FOR GROUNDING

CONSTRUCTION SPECIFICATION FOR STEEL BEAM GUIDE RAIL AND CABLE GUIDE RAIL

MATERIAL SPECIFICATION FOR ADMIXTURES FOR CONCRETE

ONTARIO PROVINCIAL STANDARD SPECIFICATION

CONSTRUCTION SPECIFICATION FOR DUST SUPPRESSANTS

MATERIAL SPECIFICATION FOR CHAIN-LINK FENCE COMPONENTS

CONSTRUCTION SPECIFICATION FOR COMPACTING

CONSTRUCTION SPECIFICATION FOR TRENCHING, BACKFILLING, AND COMPACTING

CONSTRUCTION SPECIFICATION FOR WICK DRAIN INSTALLATION

MATERIAL SPECIFICATION FOR STEEL REINFORCEMENT FOR CONCRETE

CONSTRUCTION SPECIFICATION FOR PAVEMENT MARKING

CONSTRUCTION SPECIFICATION FOR PIPELINE AND UTILITY INSTALLATION BY JACKING AND BORING

CONSTRUCTION SPECIFICATION FOR WICK DRAIN INSTALLATION

MATERIAL SPECIFICATION FOR CLAY SEAL

MATERIAL SPECIFICATION FOR STEEL TRUSS BRACKETS

MATERIAL SPECIFICATION FOR LATEX MODIFIERS FOR USE IN CONCRETE

ONTARIO PROVINCIAL STANDARD SPECIFICATION

CONSTRUCTION SPECIFICATION FOR CONCRETE CURB AND GUTTER SYSTEMS

CONSTRUCTION SPECIFICATION FOR WICK DRAIN INSTALLATION

CONSTRUCTION SPECIFICATION FOR PERMANENT SMALL SIGNS AND SUPPORT SYSTEMS

CONSTRUCTION SPECIFICATION FOR CONCRETE CURB AND GUTTER SYSTEMS

MATERIAL SPECIFICATION FOR CLAY SEAL

CONSTRUCTION SPECIFICATION FOR WICK DRAIN INSTALLATION

CONSTRUCTION SPECIFICATION FOR PRIMING GRANULAR BASE

CONSTRUCTION SPECIFICATION FOR CONCRETE CURB AND GUTTER SYSTEMS

CONSTRUCTION SPECIFICATION FOR STEEL REINFORCEMENT FOR CONCRETE

CONSTRUCTION SPECIFICATION FOR TACK COATING AND JOINT PAINTING

CONSTRUCTION SPECIFICATION FOR NEW MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION

Amendment to OPSS 518 (Nov 2011) Construction Specification for Control of Water from Dewatering Operations

CONSTRUCTION SPECIFICATION FOR GUIDE RAIL END TREATMENT - STEEL BEAM ENERGY ATTENUATING TERMINAL SYSTEMS

CONSTRUCTION SPECIFICATION FOR PRIMING GRANULAR BASE

MATERIAL SPECIFICATION FOR SODIUM CHLORIDE SOLID AND SODIUM CHLORIDE SOLUTION

PROPOSED ONTARIO PROVINCIAL STANDARD SPECIFICATION. By CATT Technical Committee Committee Chair: Alex Sandovski Phone #:

MATERIAL SPECIFICATION FOR FRAMES, GRATES, COVERS, AND GRATINGS

GENERAL SPECIFICATION FOR TEMPORARY FLOW CONTROL FOR CONSTRUCTION IN WATERBODIES

CONSTRUCTION SPECIFICATION FOR SITE PREPARATION FOR PIPELINES, UTILITIES, AND ASSOCIATED STRUCTURES

MATERIAL SPECIFICATION FOR EPOXY COATED REINFORCING STEEL BARS FOR CONCRETE

CONSTRUCTION SPECIFICATION FOR FULL DEPTH REPAIR OF CONCRETE PAVEMENT OR CONCRETE BASE

MATERIAL SPECIFICATION FOR PERFORMANCE GRADED ASPHALT CEMENT

CONSTRUCTION SPECIFICATION FOR ADJUSTING OR REBUILDING MAINTENANCE HOLES, CATCH BASINS, DITCH INLETS, AND VALVE CHAMBERS

CONSTRUCTION SPECIFICATION FOR CONCRETE SIDEWALK

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF GABIONS

CONSTRUCTION SPECIFICATION FOR SITE RESTORATION FOLLOWING INSTALLATION OF PIPELINES, UTILITIES, AND ASSOCIATED STRUCTURES

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF UNDERPASS LUMINAIRES

CONSTRUCTION SPECIFICATION FOR DUST SUPPRESSANTS

Transcription:

ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 1605 NOVEMBER 2005 MATERIAL SPECIFICATION FOR EXTRUDED EXPANDED POLYSTYRENE PAVEMENT INSULATION TABLE OF CONTENTS 1605.01 SCOPE 1605.02 REFERENCES 1605.03 DEFINITIONS 1605.04 SUBMISSION AND DESIGN REQUIREMENTS - Not Used 1605.05 MATERIALS 1605.06 EQUIPMENT - Not Used 1605.07 PRODUCTION 1605.08 QUALITY ASSURANCE 1605.09 OWNER PURCHASE OF MATERIAL APPENDICES 1605-A Commentary 1605.01 SCOPE This specification covers extruded expanded polystyrene for use as a pavement insulation for frost heave treatment of pavements. 1605.01.01 Significance and Use of Appendices Appendices are not a mandatory part of this specification unless invoked by the Owner. Appendix 1605-A is a commentary appendix to provide designers with information on the use of the specification in a Contract. Page 1 Rev. Date: 11/2005 OPSS 1605

1605.02 REFERENCES This specification refers to the following standards, publications, or specifications: Underwriters Laboratories of Canada CAN/ULC S701-05 Thermal Insulation, Polystyrene Boards and Pipe Covering 1605.03 DEFINITIONS For the purpose of this specification, the following definitions apply: Extruded Expanded Polystyrene Pavement Insulation means insulation in the form of rigid boards made by extrusion of expanded polystyrene beads. Production Lot means the quantity of insulation boards produced in a continuous period of manufacturing the same grade and thickness of product within the same production day. Truckload means a truck, including trailer, loaded with rigid insulation boards. 1605.05 MATERIALS The extruded expanded polystyrene boards shall be according to the requirements of CAN/ULC S701, Type 4, with the exception of the compressive strength. The minimum compressive strength for each grade shall be according to Table 1. 1605.07 PRODUCTION Each board of the same production lot shall be stamped with the same production code showing plant identification, type, grade, and date of production. 1605.08 QUALITY ASSURANCE 1605.08.01 Certificate of Compliance Test certificates for each production lot supplied showing compliance with all requirements of this specification shall be obtained by the Contractor and submitted to the Contract Administrator prior to installation. 1605.08.02 Sampling One board from each production lot on each truckload shall be selected at random by the Contract Administrator when the material arrives at the job site. The samples shall be tested by a laboratory designated by the Owner for compliance with this specification. 1605.08.03 Testing All test procedures shall be according to CAN/ULC S701. Page 2 Rev. Date: 11/2005 OPSS 1605

The compressive strength shall be the average of 5 specimens taken at different places across the width of the board and determined on the face perpendicular to the extrusion plane. 1605.08.04 Acceptance or Rejection Failure of any one of the sample boards to comply with any requirement of this specification shall be cause for rejection of the production lot from which it was taken. Culling of the rejected material by the Contractor shall be permitted and a proposal for retesting the remaining material shall be submitted to the Contract Administrator to demonstrate conformance with the specification. Retesting of material remaining from culling rejected material shall be at no cost to the Owner. 1605.09 OWNER PURCHASE OF MATERIAL 1605.09.01 Measurement and Payment Payment at the price specified in the purchasing order in square metres shall be full compensation for all labour, Equipment, and Material for the supply and delivery of extruded expanded polystyrene pavement insulation to the destination and at the time specified. The cost of all testing, except that performed in the Owner's laboratory, shall be included in the price. Page 3 Rev. Date: 11/2005 OPSS 1605

Table 1 Minimum Compressive Strength Grade A B C Minimum Compressive Strength, kpa at 5% Deflection or Yield 275 400 690 Page 4 Rev. Date: 11/2005 OPSS 1605

Appendix 1605-A, Commentary for OPSS 1605, November 2005 Note: This Appendix does not form part of the standard specification. It is intended to provide information to the designer on the use of this specification in a Contract. Designer Action/Considerations The designer should ensure that the Ontario Provincial Standards General Conditions of Contract and the 100 Series General Specifications are included in the Contract Documents. Related Ontario Provincial Standard Drawings OPSD 514.010 OPSD 514.020 Extruded Expanded Polystyrene Frost Heave Treatment, 25 mm Thickness Extruded Expanded Polystyrene Frost Heave Treatment, 40 mm Thickness Page 5 Rev. Date: 11/2005 OPSS 1605