MATERIAL SPECIFICATION FOR EXTRUDED EXPANDED POLYSTYRENE PAVEMENT INSULATION

Similar documents
MATERIAL SPECIFICATION FOR EXTRUDED EXPANDED POLYSTYRENE PAVEMENT INSULATION

MATERIAL SPECIFICATION FOR PRESSURE POLYETHYLENE PIPE PRODUCTS

MATERIAL SPECIFICATION FOR SMOOTH WALLED STEEL PIPE

CONSTRUCTION SPECIFICATION FOR IN-PLACE FULL DEPTH RECLAMATION OF BITUMINOUS PAVEMENT AND UNDERLYING GRANULAR

MATERIAL SPECIFICATION FOR CORRUGATED STEEL PIPE (CSP) PRODUCTS

MATERIAL SPECIFICATION FOR ADMIXTURES FOR CONCRETE

MATERIAL SPECIFICATION FOR EXTRA LOW-VOLTAGE CABLE

CONSTRUCTION SPECIFICATION FOR IN-PLACE FULL DEPTH RECLAMATION OF BITUMINOUS PAVEMENT AND UNDERLYING GRANULAR

MATERIAL SPECIFICATION FOR CIRCULAR AND ELLIPTICAL CONCRETE PIPE

MATERIAL SPECIFICATION FOR NON-PRESSURE POLYVINYL CHLORIDE PIPE PRODUCTS

CONSTRUCTION SPECIFICATION FOR IN-PLACE FULL DEPTH RECLAMATION OF BITUMINOUS PAVEMENT AND UNDERLYING GRANULAR

MATERIAL SPECIFICATION FOR ADMIXTURES FOR CONCRETE

TABLE OF CONTENTS. Use of this specification or any other specification shall be according to the Contract Documents.

CONSTRUCTION SPECIFICATION FOR SUPPORT SYSTEMS

MATERIAL SPECIFICATION FOR NON-PRESSURE POLYETHYLENE (PE) PLASTIC PIPE PRODUCTS

MATERIAL SPECIFICATION FOR LATEX MODIFIERS FOR USE IN CONCRETE

CONSTRUCTION SPECIFICATION FOR TAU II SYSTEM

CONSTRUCTION SPECIFICATION FOR THE GRINDING OF CENTRELINE AND SHOULDER RUMBLE STRIPS IN ASPHALT

MATERIAL SPECIFICATION FOR NON-PRESSURE POLYETHYLENE (PE) PLASTIC PIPE PRODUCTS

MATERIAL SPECIFICATION FOR ADMIXTURES FOR CONCRETE

MATERIAL SPECIFICATION FOR CIRCULAR AND ELLIPTICAL CONCRETE PIPE

MATERIAL SPECIFICATION FOR CIRCULAR AND ELLIPTICAL CONCRETE PIPE

MATERIAL SPECIFICATION FOR CLAY SEAL

CONSTRUCTION SPECIFICATION FOR TRAFFIC CONTROL SIGNING

CONSTRUCTION SPECIFICATION FOR RUBBLIZING CONCRETE PAVEMENT AND CONCRETE BASE

CONSTRUCTION SPECIFICATION FOR REMOVAL OF ELECTRICAL EQUIPMENT AND MATERIALS

CONSTRUCTION SPECIFICATION FOR BORROW

MATERIAL SPECIFICATION FOR SIGNS

CONSTRUCTION SPECIFICATION FOR EXPANDED METAL ANTI-GLARE SCREEN

CONSTRUCTION SPECIFICATION FOR STOCKPILING OF PATCHING MATERIALS AND PATCHING OF ASPHALT PAVEMENT

CONSTRUCTION SPECIFICATION FOR PIPELINE AND UTILITY INSTALLATION BY JACKING AND BORING

CONSTRUCTION SPECIFICATION FOR SITE PREPARATION FOR PIPELINES, UTILITIES, AND ASSOCIATED STRUCTURES

MATERIAL SPECIFICATION FOR EPOXY COATED REINFORCING STEEL BARS FOR CONCRETE

CONSTRUCTION SPECIFICATION FOR TRAFFIC CONTROL SIGNING

CONSTRUCTION SPECIFICATION FOR BORROW

MATERIAL SPECIFICATION FOR CALCIUM CHLORIDE

MATERIAL SPECIFICATION FOR STEEL TRUSS BRACKETS

CONSTRUCTION SPECIFICATION FOR GRANULAR SEALING

MATERIAL SPECIFICATION FOR BEARINGS - ELASTOMERIC PLAIN AND STEEL LAMINATED

Amendment to OPSS 416 (Nov 2013) Construction Specification for Pipeline and Utility Installation by Jacking and Boring

CONSTRUCTION SPECIFICATION FOR EARTH BORROW

MATERIAL SPECIFICATION FOR SPUN CONCRETE POLES

CONSTRUCTION SPECIFICATION FOR TRENCHING, BACKFILLING, AND COMPACTING

CONSTRUCTION SPECIFICATION FOR TRENCHING, BACKFILLING, AND COMPACTING

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF GABIONS

Amendment to OPSS 518 (Nov 2011) Construction Specification for Control of Water from Dewatering Operations

MATERIAL SPECIFICATION FOR STANDARD HIGHWAY FENCE COMPONENTS

MATERIAL SPECIFICATION FOR CLAY SEAL

CONSTRUCTION SPECIFICATION FOR CONCRETE FOOTINGS AND MAINTENANCE PLATFORMS FOR HIGH MAST LIGHTING POLES

MATERIAL SPECIFICATION FOR NON-PRESSURE POLYETHYLENE PLASTIC PIPE PRODUCTS

CONSTRUCTION SPECIFICATION FOR PERMANENT SMALL SIGNS AND SUPPORT SYSTEMS

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF POWER SUPPLY EQUIPMENT

MATERIAL SPECIFICATION FOR CHAIN-LINK FENCE COMPONENTS

CONSTRUCTION SPECIFICATION FOR PRIMING GRANULAR BASE

MATERIAL SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS

CONSTRUCTION SPECIFICATION FOR DUST SUPPRESSANTS

GENERAL SPECIFICATION FOR TEMPORARY FLOW CONTROL FOR CONSTRUCTION IN WATERBODIES

MATERIAL SPECIFICATION FOR STEEL REINFORCEMENT FOR CONCRETE

CONSTRUCTION SPECIFICATION FOR TRENCHING, BACKFILLING, AND COMPACTING

MATERIAL SPECIFICATION FOR SODIUM CHLORIDE SOLID AND SODIUM CHLORIDE SOLUTION

CONSTRUCTION SPECIFICATION FOR SITE RESTORATION FOLLOWING INSTALLATION OF PIPELINES, UTILITIES, AND ASSOCIATED STRUCTURES

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF SECTIONAL STEEL HIGH MAST LIGHTING POLES

CONSTRUCTION SPECIFICATION FOR WICK DRAIN INSTALLATION

MATERIAL SPECIFICATION FOR FRAMES, GRATES, COVERS, AND GRATINGS

CONSTRUCTION SPECIFICATION FOR WICK DRAIN INSTALLATION

CONSTRUCTION SPECIFICATION FOR ADJUSTING OR REBUILDING MAINTENANCE HOLES, CATCH BASINS, DITCH INLETS, AND VALVE CHAMBERS

CONSTRUCTION SPECIFICATION FOR PIPELINE AND UTILITY INSTALLATION BY JACKING AND BORING

MATERIAL SPECIFICATION FOR CLAY SEAL

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF UNDERPASS LUMINAIRES

MATERIAL SPECIFICATION FOR AGGREGATES - GENERAL

MATERIAL SPECIFICATION FOR DECK JOINT ASSEMBLIES

CONSTRUCTION SPECIFICATION FOR PIPELINE INSTALLATION BY TUNNELLING

CONSTRUCTION SPECIFICATION FOR CONCRETE CURB AND GUTTER SYSTEMS

CONSTRUCTION SPECIFICATION FOR THE CLEANING AND FLUSHING OF PIPE SEWERS, CATCHBASINS, MAINTENANCE HOLES, DITCH INLETS, AND OIL-GRIT SEPARATORS

CONSTRUCTION SPECIFICATION FOR PRIMING GRANULAR BASE

Construction Specification for Trenching, Backfilling and Compacting

CONSTRUCTION SPECIFICATION FOR STANDARD HIGHWAY FENCE

CONSTRUCTION SPECIFICATION FOR GUIDE RAIL END TREATMENT - STEEL BEAM ENERGY ATTENUATING TERMINAL SYSTEMS

MATERIAL SPECIFICATION FOR CALCIUM CHLORIDE

CONSTRUCTION SPECIFICATION FOR ABRASIVE BLAST CLEANING - CONCRETE CONSTRUCTION

MATERIAL SPECIFICATION FOR SMOOTH WALLED STEEL PIPE

CONSTRUCTION SPECIFICATION FOR FULL DEPTH REPAIR OF CONCRETE PAVEMENT OR CONCRETE BASE

MATERIAL SPECIFICATION FOR FRAMES, GRATES, COVERS, AND GRATINGS

CONSTRUCTION SPECIFICATION FOR PAVEMENT MARKING

MATERIAL SPECIFICATION FOR STANDARD HIGHWAY FENCE COMPONENTS

MATERIAL SPECIFICATION FOR HIGH PRESSURE SODIUM LUMINAIRES FOR HIGHWAY LIGHTING

PROPOSED ONTARIO PROVINCIAL STANDARD SPECIFICATION. By CATT Technical Committee Committee Chair: Alex Sandovski Phone #:

CONSTRUCTION SPECIFICATION FOR WICK DRAIN INSTALLATION

CONSTRUCTION SPECIFICATION FOR OPEN GRADED DRAINAGE LAYER

CONSTRUCTION SPECIFICATION FOR SITE PREPARATION FOR PIPELINES, UTILITIES, AND ASSOCIATED STRUCTURES

MATERIAL SPECIFICATION FOR STEEL POLES, BASE MOUNTED

CONSTRUCTION SPECIFICATION FOR TACK COATING AND JOINT PAINTING

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

CONSTRUCTION SPECIFICATION FOR COMPACTING

CONSTRUCTION SPECIFICATION FOR NEW MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ROADWAY LUMINAIRES

CONSTRUCTION SPECIFICATION FOR SODDING

CONSTRUCTION SPECIFICATION FOR SODDING

CONSTRUCTION SPECIFICATION FOR CONCRETE SIDEWALK

CONSTRUCTION SPECIFICATION FOR GUIDE RAIL END TREATMENT - ECCENTRIC LOADER TERMINAL SYSTEM

Transcription:

ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 1605 NOVEMBER 2010 MATERIAL SPECIFICATION FOR EXTRUDED EXPANDED POLYSTYRENE PAVEMENT INSULATION TABLE OF CONTENTS 1605.01 SCOPE 1605.02 REFERENCES 1605.03 DEFINITIONS 1605.04 DESIGN AND SUBMISSION REQUIREMENTS - Not Used 1605.05 MATERIALS 1605.06 EQUIPMENT - Not Used 1605.07 PRODUCTION 1605.08 QUALITY ASSURANCE 1605.09 OWNER PURCHASE OF MATERIAL APPENDICES 1605-A Commentary 1605.01 SCOPE This specification covers extruded expanded polystyrene for use as pavement insulation for frost heave treatment of pavements. 1605.01.01 Specification Significance and Use This specification has been developed for use in provincial- and municipal-oriented Contracts. The administration, testing, and payment policies, procedures, and practices reflected in this specification correspond to those used by many municipalities and the Ontario Ministry of Transportation. Use of this specification or any other specification shall be according to the Contract Documents. Page 1 Rev. Date: 11/2010 OPSS 1605

1605.01.02 Appendices Significance and Use Appendices are not for use in provincial contracts as they are developed for municipal use, and then, only when invoked by the Owner. Appendices are developed for the Owner s use only. Inclusion of an appendix as part of the Contract Documents is solely at the discretion of the Owner. Appendices are not a mandatory part of this specification and only become part of the Contract Documents as the Owner invokes them. Invoking a particular appendix does not obligate an Owner to use all available appendices. Only invoked appendices form part of the Contract Documents. The decision to use any appendix is determined by an Owner after considering their contract requirements and their administrative, payment, and testing procedures, policies, and practices. Depending on these considerations, an Owner may not wish to invoke some or any of the available appendices. 1605.02 REFERENCES When the Contract Documents indicate that provincial-oriented specifications are to be used and there is a provincial-oriented specification of the same number as those listed below, references within this specification to an OPSS shall be deemed to mean OPSS.PROV, unless use of a municipal-oriented specification is specified in the Contract Documents. When there is not a corresponding provincialoriented specification, the references below shall be considered to be to the OPSS listed, unless use of a municipal-oriented specification is specified in the Contract Documents. When the Contract Documents indicate that municipal-oriented specifications are to be used and there is a municipal-oriented specification of the same number as those listed below, references within this specification to an OPSS shall be deemed to mean OPSS.MUNI, unless use of a provincial-oriented specification is specified in the Contract Documents. When there is not a corresponding municipaloriented specification, the references below shall be considered to be the OPSS listed, unless use of a provincial-oriented specification is specified in the Contract Documents. This specification refers to the following standards, publications, or specifications: Underwriters Laboratories of Canada (ULC) CAN/ULC S701-05 Thermal Insulation, Polystyrene, Boards and Pipe Covering 1605.03 DEFINITIONS For the purpose of this specification, the following definitions apply: Extruded Expanded Polystyrene Pavement Insulation means insulation in the form of rigid boards made by extrusion of expanded polystyrene beads. Production Lot means the quantity of insulation boards produced in a continuous period of manufacturing the same grade and thickness of product within the same production day. Truckload means a truck, including trailer, loaded with rigid insulation boards. Page 2 Rev. Date: 11/2010 OPSS 1605

1605.05 MATERIALS The extruded expanded polystyrene boards shall be according to the requirements of CAN/ULC S701, Type 4, with the exception of the compressive strength. The minimum compressive strength for each grade shall be according to Table 1. 1605.07 PRODUCTION Each board of the same production lot shall be stamped with the same production code showing plant identification, type, grade, and date of production (i.e., yyyy-mm-dd). 1605.08 QUALITY ASSURANCE 1605.08.01 Certificate of Compliance Test certificates for each production lot supplied showing compliance with all requirements of this specification shall be obtained by the Contractor and submitted to the Contract Administrator prior to installation. 1605.08.02 Sampling One board from each production lot on each truckload shall be selected at random by the Contract Administrator when the material arrives at the job site. The samples shall be tested by a laboratory designated by the Owner for compliance with this specification. 1605.08.03 Testing All test procedures shall be according to CAN/ULC S701. The compressive strength shall be the average of 5 specimens taken at different places across the width of the board and determined on the face perpendicular to the extrusion plane. 1605.08.04 Acceptance or Rejection Failure of any one of the sample boards to comply with any requirement of this specification shall be cause for rejection of the production lot from which it was taken. Culling of the rejected material by the Contractor shall be permitted and a proposal for retesting the remaining material shall be submitted to the Contract Administrator to demonstrate conformance with the specification. Retesting of material remaining from culling rejected material shall be at no cost to the Owner. 1605.09 OWNER PURCHASE OF MATERIAL 1605.09.01 Measurement and Payment Measurement of extruded expanded polystyrene pavement insulation shall be by area in square metres. Payment at the price specified in the purchasing order shall be for the supply of extruded expanded polystyrene pavement insulation delivered to the destination on the date and time specified. The cost of all testing, except that performed in the Owner's laboratory, shall be included in the price. Page 3 Rev. Date: 11/2010 OPSS 1605

TABLE 1 Minimum Compressive Strength Grade Minimum Compressive Strength, kpa at 5% Deflection or Yield A 275 B 400 C 690 Page 4 Rev. Date: 11/2010 OPSS 1605

Appendix 1605-A, November 2010 FOR USE WHILE DESIGNING MUNICIPAL CONTRACTS Note: This is a non-mandatory Commentary Appendix intended to provide information to a designer, during the design stage of a contract, on the use of the OPS specification in a municipal contract. This appendix does not form part of the standard specification. Actions and considerations discussed in this appendix are for information purposes only and do not supersede an Owner s design decisions and methodology. Designer Action/Considerations The designer should ensure that the General Conditions of Contract and the 100 Series General Specifications are included in the Contract Documents. Related Ontario Provincial Standard Drawings OPSD 514.010 OPSD 514.020 Extruded Expanded Polystyrene Frost Heave Treatment, 25 mm Thickness Extruded Expanded Polystyrene Frost Heave Treatment, 40 mm Thickness Page 5 Rev. Date: 11/2010 OPSS 1605