LISTING INFORMATION OF Dryvit - Category 2 OUTSULATION NC EIFS Wall Systems SPEC ID: 29344

Similar documents
LISTING INFORMATION OF Dryvit - Category 1 OUTSULATION EIFS Wall Systems SPEC ID: 29311

LISTING INFORMATION OF Metl-Span, LLC THERMALSAFE 8" Thick 3 Hour Fire Rated Panels SPEC ID: 29868

STRATUM GUARD I AND II An Exterior Insulation and Finish System with Drainage DSC106C. Stratum Guard I and II System Installation Details

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

LISTING INFORMATION OF CCI Manufacturing Inc. - HiBAR SPEC ID: CCI Manufacturing Inc Ave. Edmonton, AB T5V 1K5 Canada

LISTING INFORMATION OF Metl-Span, LLC THERMALSAFE 4" Thick 1 Hour Fire Rated Wall Panels SPEC ID: 29555

BACKSTOP TM NT - Texture A high performance, water-resistive membrane and air barrier

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: DRYVIT SYSTEMS, INC.

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848

LISTING INFORMATION OF Metl-Span, LLC THERMALSAFE 6" Thick 2-hour Fire Rated Panels SPEC ID: 29771

ESR-1794* Reissued September 1, 2012 This report is subject to renewal November 1, 2014.

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

BACKSTOP NT - Texture A high performance, non-cementitious water-resistive membrane and air barrier. Backstop NT - Texture Application Instructions

FEDDERLITE PANEL SYSTEM Prefabricated, Lightweight, Outsulation Exterior Wall Panels with Integrated Reinforcing Channels

Textured Acrylic Finishes (TAFS) Over ICFs Specifications

LISTING INFORMATION OF Mitek Design No. MCI/WI SPEC ID: MiTek Canada, Inc. 100 Industrial Road Bradford, ON L3Z 3G7 Canada

R E S I D E N T I A L B U I L D E R S R E F E R E N C E G U I D E

REPORT HOLDER: COREV AMERICA BRITTMOORE PARK DRIVE HOUSTON, TEXAS EVALUATION SUBJECT:

LISTING INFORMATION OF ClarkDietrich Wall Assembly Design No. CD/WA SPEC ID: 26053

BACKSTOP NT - VB A high performance, non-cementitious water-resistive membrane and air/vapour barrier

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

LISTING INFORMATION OF Fox Block Insulating Concrete Forms (Fox Block ICFs) SPEC ID: 32745

LISTING INFORMATION OF Epilay - Superior, Ultra and Platinum Roofing Underlayments SPEC ID: Epilay Inc S. Main Street, E1 unit C

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

OUTSULATION MD (NC) SYSTEM A commercial Exterior Insulation and Finish System with Moisture Drainage and an optional Non-Combustible (NC) Base Coat

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: PAREX USA, INC.

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER:

Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration

ESR-2771 Reissued December 1, 2013 This report is subject to renewal December 1, 2014.

DSC137NC. Outsulation Plus / Outsulation Plus (NC) Non-Combustible Specifications

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Outsulation Plus / Outsulation Plus (NC) Non-Combustible System Specifications

Code Compliance Research Report CCRR-0228

Beginning of the Course

Originally Issued: 11/30/2015 Revised: 10/20/2017 Valid Through: 11/30/2018

LISTING INFORMATION OF ClarkDietrich Steel 'H' Stud and 'U' Track Fire-resistance-rated Area Separation Wall Assemblies SPEC ID: 26662

Technical Data Sheet

LISTING INFORMATION OF SIPA - Structural Insulated Panels (SIPs) SPEC ID: Structural Insulated Panel Association (SIPA) P.O.

DSC100NC. Outsulation / Outsulation (NC) Non-Combustible System Specifications

Inspection Fundamentals: Stucco & EIFS

THERMAL-FLEX COATING ASSEMBLY TO INSULATION BOARD MANUFACTURERS SPECIFICATIONS / SECTION 07240

(800) (562) A Subsidiary of the International Code Council

Duct Wrap Flexible Wraps

LOWER MACUNGIE TOWNSHIP COMMUNITY CENTER ADDITIONS AND RENOVATIONS

Insulated Concrete Forms (ICFs)

Code Compliance Research Report CCRR-0231

Advantage ICF System Product Information Bulletin

The Perfect Block OEM ICC Equivalent Product Compliance Report

ProGUARD DP The Game-changing Wall System

Sept 30, 2004 Page 1

DSC602NC. Outsulation PD / Outsulation PD (NC) Non-Combustible System Application Instructions

ProGUARD Guide Specification

DRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board

Code Compliance Research Report CCRR 0270

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC. EVALUATION SUBJECT:

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

THERMAL-FLEX ICF INSULATED CONCRETE FORMS COATING ASSEMBLY TO ICF BLOCK MANUFACTURERS SPECIFICATIONS / SECTION STUC-O-FLEX PART 1 - GENERAL

THERMAL-FLEX ICF INSULATED CONCRETE FORMS COATING ASSEMBLY TO ICF BLOCK MANUFACTURERS SPECIFICATIONS / SECTION STUC-O-FLEX PART 1 - GENERAL

Dryvit Textured Acrylic Finishes (TAFS) 100% Acrylic Exterior Architectural Coatings

This is what you see. DS 265

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

ICC-ES Evaluation Report Reissued April 1, 2010 This report is subject to re-examination in two years.

The Right Choice for Stucco.

FOCAL POINT RENDAPANEL TM CLADDING SYSTEM

SECTION WATER-DRAINAGE EXTERIOR INSULATION AND FINISH SYSTEM (EIFS)

AquaFlash System Installation Guide DS196

AUTHORIZATION TO MARK

REPORT HOLDER: GREENMAKER INDUSTRIES, LLC 697 OAKWOOD AVENUE WEST HARTFORD, CONNECTICUT EVALUATION SUBJECT: DECOPLAST DDARS NOTCHED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: STO CORPORATION

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

Senergy Base Coats / Adhesives Fast setting dry-mix polymer adhesive. Product Bulletin

DS131 EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

Dryvit Interior Architectural Coatings Specifications

RENOVATION SOLUTIONS FROM DRYVIT

Dryvit Textured Acrylic Finishes. (TAFS Option 2) For Exterior Soffits Specifications

CEMENT BOARD MD FINISH SYSTEM

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: DIRECT-APPLIED FINISH SYSTEMS REPORT HOLDER: STO CORP.

STRATUM GUARD I & II SYSTEMS Moisture Drainage EIF Systems Over Wood Substrates

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: SUPERFORM PRODUCTS LTD. EVALUATION SUBJECT:

SECTION CEMENT BOARD SUPPORTED ADHERED MASONRY VENEER. 2. Installation materials including adhesives, mortars, and pointing mortars.

CommercialComplete Wall System

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: DIRECT-APPLIED FINISH SYSTEMS REPORT HOLDER: BASF CORPORATION WALL SYSTEMS

Code Compliance Research Report CCRR-1060

Differences between EnCon Insulated Precast and EIFS

STRATUM GUARD I & II An exterior insulation finish system with drainage. Stratum Guard System Specifications

Finestone Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor rigid insulation board

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.

Code Compliance Research Report CCRR-0238

REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: September 14, 2012 REVISED DATE: N/A

Code Compliance Research Report CCRR-0238

FLEXITHERM Double layer with Graphite Core Insulation

Transcription:

LISTING INFORMATION OF Dryvit - Category 2 OUTSULATION NC EIFS Wall Systems SPEC ID: 29344 Dryvit Systems Canada 129 Ringwood Drive Stouffville, ON L4A 8C1 Canada This report is for the exclusive use of Intertek s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Dryvit Systems Canada 29344 Rev: Mar 6 2018 3:52PM Uncontrolled Copy Page 1 of 10

Dryvit Category 2 OUTSULATION Wall Systems DRYVIT OUTSULATION NC WALL SYSTEM DRYVIT OUTSULATION PLUS NC WALL SYSTEM DRYVIT OUTSULATION MD NC WALL SYSTEM DRYVIT OUTSULATION PD NC WALL SYSTEM Dryvit Category 2 OUTSULATION Wall Systems are Exterior Insulation and Finish Systems (EIFS) consisting of an adhesive, expanded polystyrene insulation board, non-combustible base coat, reinforcing mesh and a finish coat. The systems can also be mechanically attached through the expanded polystyrene insulation board into approved substrates. Refer to Design Listings DSC-WDEIFS 15-01, DSC-WDEIFS 15-02, and DSC-WDEIFS 15-03 for detailed specifications on each system. RATINGS Standard Rating Design Number CAN/ULC S101 15 minute Stay-in-Place DSC-WDEIFS 15-01 DSC- WDEIFS 15-02 DSC-WDEIFS 15-03 Note: The Primus DM and Genesis DM base coats within the Design Listings are considered noncombustible per testing conducted in accordance with CAN/ULC S114. Attribute Value Criteria CAN / ULC S101 (2007) Criteria CAN / ULC S114 (2005) Criteria CAN / ULC S101 (2014) CSI Code (EIFS) Intertek Services Certification Listed or Inspected LISTED Listing Section EIFS CATEGORY 2 Report Number 7212; 3172311; 100182049; 100829985; 102420572; 103282758 Spec ID 29344 Dryvit Systems Canada 29344 Rev: Mar 6 2018 3:52PM Uncontrolled Copy Page 2 of 10

DRAWING INDEX DSC-WDEIFS 15-01 DSC-WDEIFS 15-02 DSC-WDEIFS 15-03 Dryvit Systems Canada 29344 Rev: Mar 6 2018 3:52PM Uncontrolled Copy Page 3 of 10

DSC-WDEIFS 15-01 07 24 19 Water-Drainage Exterior Insulation and Finish Systems Page 1 of 2 Design Number: DSC/WDEIFS 15-01 EXTERIOR WALL SYSTEMS Dryvit Systems Canada Dryvit OUTSULATION NC, OUTSULATION PLUS NC, AND FEDDERLITE 2000 CAN/ULC S101 (2014) Rating: 15 Minute Meets the Requirements of Clause 3.2.3.8(1)(b) of the National Building Code of Canada, 2015 and 2010 1. WALL ASSEMBLY: Construct a wall assembly that complies with the local Building Code or other applicable regulatory requirements when those are greater. System may be installed over ICF. Total combined thickness of the exterior side ICF and the Dryvit EIFS cannot exceed max. allowable thickness noted in Item 3. Additionally, concrete is to be formed flush with ICF surface at floor-lines for the securement of Dryvit detail mesh to the substrate. If installed, the Water Resistive Barrier shall be Dryflex with mesh reinforcement. 2. WATER RESISTIVE BARRIER: Apply one of the following membrane systems to the exterior side of the wall assembly (Item 1): Dryvit Systems Canada 29344 Rev: Mar 6 2018 3:52PM Uncontrolled Copy Page 4 of 10

DSC-WDEIFS 15-01 (2 of 2) 07 24 19 Water-Drainage Exterior Insulation and Finish Systems Page 2 of 2 A. DryvitDryflex Polymer based cementitious air/moisture barrier applied in accordance with manufacturer's instructions or, B. Dryvit Backstop NT /NT VB Polymer based non-cementitious air/moisture barrier applied in accordance with manufacturer s instructions. 3. ADHESIVE: Mix Dryvit adhesive (Item 5) and apply using a 12.5mm x 12.5mm (1/2 in. 1/2 in.) stainless steel notched trowel, in accordance with manufacturer s application instructions. Adhesive ribbons shall run vertically and measure approximately 9mm (3/8 in.) when formed and will be compressed when adhered to the substrate. 4. INSULATION BOARD: Secure insulation board with adhesive (Item 3) using one of the following options: A. 16 kg/m 3 (1 pcf) expanded polystyrene (EPS) board, max. 150mm (6 in.) thick, bonded with adhesive. B. 16 kg/m 3 (1 pcf) graphite-enhanced polystyrene (GPS) board, max. 150mm (6 in.) thick, bonded with adhesive and four supplemental mechanical fasteners with appropriate type and length of corrosion-resistant fasteners and PBH Washers by Demand Products, Wind-lock Wind-Devil 2 plastic washers, or approved equivalent washer, per 610 x 1220mm (24 in. x 48 in.). Fasteners must be within 200mm (8 in.) of the sides of the boards and within 100mm (4 in.) of the top and bottom. Exact location will depend upon the substrate (spacing of framing, or solid masonry). C. 28.8 kg/m 3 (1.8 pcf) extruded polystyrene (XPS) board, max. 83mm (3.3 in.) thick, bonded with adhesive. The board face receiving adhesive must be sanded. Insulation boards must be manufactured under a quality assurance program and conform- to CAN/ULC S701 Type 1 for EPS and GPS, and Type 4 for XPS, with a flame spread rating less than 500 per CAN/ULC S102.2. All outside edges are to be chamfered. 5. BASE COAT: Apply one of the following noncombustible protective materials to the exterior side of the insulation board (Item 4). In accordance with the manufacturer s application instructions, the exterior face of the insulation board must be sanded. After the initial coat, apply reinforcing mesh (Item 6) and then additional coats so that the mesh (Item 6) is completely embedded and the final thickness of the base coat is min. 2mm (1/12 in.). A. Primus DM Adhesive/Base Coat Mixed at a 4:1 ratio with clean potable water or, B. Genesis DM Adhesive/Base Coat Mixed at a 4:1 ratio with clean potable water. 6. REINFORCING MESH: Apply Dryvit mesh, either "Standard ", "Standard Plus", Intermediate Mesh 150 372 g/m 2 (0.49 1.22 oz/ft 2 ) self-extinguishing, edges overlapped 75mm (3 in.) min. and embedded into the base coat (Item 5) with a stainless steel trowel. The fiberglass mesh is prewrapped, back-wrapped, or edge-wrapped with min. 63mm (2-1/2 in.) face coverage at terminations to encapsulate the insulation board. For additional impact resistance, a layer of Dryvit Panzer Meshes 488 671 g/m 2 (1.6 2.2 oz/ft 2 ) may be applied to the system prior to the application of standard meshes in accordance with the manufacturer s application instructions. 7. FINISH COAT: Apply Dryvit "DPR" finish, StoneMist, TerraNeo, Ameristone, LymeStone, Custom Brick, and smooth coatings over the base coat (Item 5) in accordance with the manufacturer s application instructions for the specific finish using stainless steel trowel. 8. OPTIONAL MECHANICAL FASTENING FOR EPS AND XPS INSULATION (Not Shown): Where supplemental mechanical fastening is to be used for restraining the insulation to substrate, mechanical fasteners with appropriate type and length of corrosionresistant fasteners and PBH Washers by Demand Products, Wind-lock Wind-Devil 2 plastic washers, or approved equivalent washer, can be used for penetrating through the insulation into the component substrate. Details of this installation can be found in the manufacturer s application instructions. Dryvit Systems Canada 29344 Rev: Mar 6 2018 3:52PM Uncontrolled Copy Page 5 of 10

DSC-WDEIFS 15-02 07 24 19 Water-Drainage Exterior Insulation and Finish Systems Page 1 of 3 Design Number: DSC/WDEIFS 15-02 EXTERIOR WALL SYSTEMS Dryvit Systems Canada Dryvit OUTSULATION PD NC CAN/ULC S101 (2014) Rating: 15 Minute Meets the Requirements of Clause 3.2.3.8(1)(b) of the National Building Code of Canada, 2015 and 2010 1. WALL ASSEMBLY: Construct a wall assembly that complies with the local Building Code or other applicable regulatory requirements when those are greater. System may be installed over ICF. Total combined thickness of the exterior side ICF and the Dryvit EIFS cannot exceed max. allowable thickness noted in Item 3. Additionally, concrete is to be formed flush with ICF surface at floor-lines for the securement of Dryvit detail mesh to the substrate. If installed, the Water Resistive Barrier shall be Dryflex with mesh reinforcement. Dryvit Systems Canada 29344 Rev: Mar 6 2018 3:52PM Uncontrolled Copy Page 6 of 10

DSC-WDEIFS 15-02 (2 of 3) 07 24 19 Water-Drainage Exterior Insulation and Finish Systems Page 2 of 3 2. WATER RESISTIVE BARRIER: Apply one of the following membrane systems to the exterior side of the wall assembly (Item 1): A. Dryvit Dryflex Polymer based cementitious air/moisture barrier applied in accordance with manufacturer's instructions or, B. Dryvit Backstop NT /NT VB Polymer based non-cementitious air/moisture barrier applied in accordance with manufacturer's instructions. 3. ADHESIVE: Mix Dryvit adhesive (Item 5) and apply using a 12.5mm x 12.5mm (1/2 in. 1/2 in.) stainless steel notched trowel, in accordance with manufacturer s application instructions. Adhesive ribbons shall run vertically and measure approximately 9mm (3/8 in.) when formed and will be compressed when adhered to the substrate. 4. INSULATION BOARD: Secure insulation board with adhesive (Item 3) using one of the following options: A. 16 kg/m 3 (1 pcf) expanded polystyrene (EPS) board, min. 51mm (2 in.) thick and max. 150mm (6 in.) thick, bonded with adhesive. B. 16 kg/m 3 (1 pcf) graphite-enhanced polystyrene (GPS) board, min. 51mm (2 in.) thick and max. 150mm (6 in.) thick, bonded with adhesive and four supplemental mechanical fasteners with appropriate type and length of corrosion-resistant fasteners and PBH Washers by Demand Products, Windlock Wind-Devil 2 plastic washers, or approved equivalent washer, per 610 x 1220mm (24 in. x 48 in.). Fasteners must be within 200mm (8 in.) of the sides of the boards and within 100mm (4 in.) of the top and bottom. Exact location will depend upon the substrate (spacing of framing, or solid masonry). C. 28.8 kg/m 3 (1.8 pcf) extruded polystyrene (XPS) board, min. 51mm (2 in.) thick and max. 83mm (3.3 in.) thick, bonded with adhesive. The board face receiving adhesive must be sanded. Insulation boards must be manufactured under a quality assurance program and conform- to CAN/ULC S701 Type 1 for EPS and GPS, and Type 4 for XPS, with a flame spread rating less than 500 per CAN/ULC S102.2. 3. Insulation board has profile consisting of three 10mm (0.4 in.) deep 25mm (1 in.) wide rectangular grooves running vertically on the interior side of the board spaced 305mm (12 in.) oc. Between rectangular grooves are four inverted triangular grooves spaced 305mm (12 in.) oc. The grooves measure 38mm (1-1/2 in.) at the base and narrow to 2mm (0.08 in.) at the peak. The base of the triangles aligns with the perimeter chamfer at a depth of 15mm (0.6 in.). Insulation boards have profile consisting of 6-10mm (.25-.40 in.) 25mm (1 in.) grooves running vertically on the interior side of the board spaced 305mm (12 in.) oc. All outside edges are to be chamfered. 5. BASE COAT: Apply one of the following noncombustible protective materials to the exterior side of the insulation board (Item 4). In accordance with the manufacturer s application instructions, the exterior face of the insulation board must be sanded. After the initial coat, apply reinforcing mesh (Item 6) and then additional coats so that the mesh (Item 6) is completely embedded and the final thickness of the base coat is min. 2mm (1/12 in.). A. Primus DM Adhesive/Base Coat Mixed at a 4:1 ratio with clean potable water or, B. Genesis DM Adhesive/Base Coat Mixed at a 4:1 ratio with clean potable water. 6. REINFORCING MESH: Apply Dryvit mesh, either "Standard ", "Standard Plus", Intermediate Mesh 150 372 g/m 2 (0.49 1.22 oz/ft 2 ) self-extinguishing, edges overlapped 75mm (3 in.) min. and embedded into the base coat (Item 5) with a stainless steel trowel. The fiberglass mesh is pre-wrapped, back-wrapped, or edgewrapped with min. 63mm (2-1/2 in.) face coverage at terminations to encapsulate the Dryvit Systems Canada 29344 Rev: Mar 6 2018 3:52PM Uncontrolled Copy Page 7 of 10

DSC-WDEIFS 15-02 (3 of 3) 07 24 19 Water-Drainage Exterior Insulation and Finish Systems Page 3 of 3 insulation board. For additional impact resistance, a layer of Dryvit Panzer Meshes 488 671 g/m 2 (1.6 2.2 oz/ft 2 ) may be applied to the system prior to the application of standard meshes in accordance with the manufacturer s application instructions. 7. FINISH COAT: Apply Dryvit "DPR" finish, StoneMist, TerraNeo, Ameristone, LymeStone, Custom Brick, and smooth coatings over the base coat (Item 5) in accordance with the manufacturer s application instructions for the specific finish using stainless steel trowel. 8. OPTIONAL MECHANICAL FASTENING FOR EPS AND XPS INSULATION (Not Shown): Where supplemental mechanical fastening is to be used for restraining the insulation to substrate, mechanical fasteners with appropriate type and length of corrosion-resistant fasteners and PBH Washers by Demand Products, Wind-lock Wind-Devil 2 plastic washers, or approved equivalent washer, can be used for penetrating through the insulation into the component substrate. Details of this installation can be found in the manufacturer s application instructions. Dryvit Systems Canada 29344 Rev: Mar 6 2018 3:52PM Uncontrolled Copy Page 8 of 10

DSC-WDEIFS 15-03 07 24 19 Water-Drainage Exterior Insulation and Finish Systems Page 1 of 2 Design Number: DSC/WDEIFS 15-03 EXTERIOR WALL SYSTEMS Dryvit Systems Canada Dryvit OUTSULATION MD NC CAN/ULC S101 (2014) Rating: 15 Minute Meets the Requirements of Clause 3.2.3.8(1)(b) of the National Building Code of Canada, 2015 and 2010 1. WALL ASSEMBLY: Construct a wall assembly that complies with the local Building Code or other applicable regulatory requirements when those are greater. System may be installed over ICF. Total combined thickness of the exterior side ICF and the Dryvit EIFS cannot exceed max. allowable thickness noted in Item 3. Additionally, concrete is to be formed flush with ICF surface at floor-lines for the securement of Dryvit detail mesh to the substrate. If installed, the Water Resistive Barrier shall be Dryflex with mesh reinforcement. 2. WATER RESISTIVE BARRIER: Apply one of the following membrane systems to the exterior side of the wall assembly (Item 1): A. Dryvit Dryflex Polymer based cementitious air/moisture barrier applied in accordance with manufacturer's instructions or, Dryvit Systems Canada 29344 Rev: Mar 6 2018 3:52PM Uncontrolled Copy Page 9 of 10

DSC-WDEIFS 15-03 (2 of 2) 07 24 19 Water-Drainage Exterior Insulation and Finish Systems Page 2 of 2 B. Dryvit Backstop NT /NT VB Polymer based non-cementitious air/moisture barrier applied in accordance with manufacturer's instructions. 3. ADHESIVE: Mix Dryvit adhesive (Item 5) and apply using a 12.5mm x 12.5mm (1/2 in. 1/2 in.) stainless steel notched trowel, in accordance with manufacturer s application instructions. Adhesive ribbons shall run vertically and measure approximately 9mm (3/8 in.) when formed and will be compressed when adhered to the substrate. 4. INSULATION BOARD: Secure insulation board with adhesive (Item 3) using one of the following options: A. 16 kg/m 3 (1 pcf) expanded polystyrene (EPS) board, min. 51mm (2 in.) thick and max. 150mm (6 in.) thick, bonded with adhesive. B. 16 kg/m 3 (1 pcf) graphite-enhanced polystyrene (GPS) board, min. 51mm (2 in.) thick and max. 150mm (6 in.) thick, bonded with adhesive and four supplemental mechanical fasteners with appropriate type and length of corrosionresistant fasteners and PBH Washers by Demand Products, Wind-lock Wind-Devil 2 plastic washers, or approved equivalent washer, per 610 x 1220mm (24 in. x 48 in.). Fasteners must be within 200mm (8 in.) of the sides of the boards and within 100mm (4 in.) of the top and bottom. Exact location will depend upon the substrate (spacing of framing, or solid masonry). C. 28.8 kg/m 3 (1.8 pcf) extruded polystyrene (XPS) board, min. 51mm (2 in.) thick and max. 83mm (3.3 in.) thick, bonded with adhesive. The board face receiving adhesive must be sanded. Insulation boards must be manufactured under a quality assurance program and conform- to CAN/ULC S701 Type 1 for EPS and GPS, and Type 4 for XPS, with a flame spread rating less than 500 per CAN/ULC S102.2. Insulation boards have a profile consisting of 6-10mm (.25-.40 in.) 25mm (1 in.) grooves running vertically on the interior side of the board spaced 305mm (12 in.) oc. All outside edges are to be chamfered. 5. BASE COAT: Apply one of the following noncombustible protective materials to the exterior side of the insulation board (Item 4). In accordance with the manufacturer s application instructions, the exterior face of the insulation board must be sanded. After the initial coat, apply reinforcing mesh (Item 6) and then additional coats so that the mesh (Item 6) is completely embedded and the final thickness of the base coat is min. 2mm (1/12 in.). A. Primus DM Adhesive/Base Coat mixed at a 4:1 ratio with clean potable water or, B. Genesis DM Adhesive/Base Coat mixed at a 4:1 ratio with clean potable water. 6. REINFORCING MESH: Apply Dryvit mesh, either "Standard ", "Standard Plus", Intermediate Mesh 150 372 g/m 2 (0.49 1.22 oz/ft 2 ) self-extinguishing, edges overlapped 75mm (3 in.) min. and embedded into the base coat (Item 5) with a stainless steel trowel. The fiberglass mesh is prewrapped, back-wrapped, or edge-wrapped with min. 63mm (2-1/2 in.) face coverage at terminations to encapsulate the insulation board. For additional impact resistance, a layer of Dryvit Panzer Meshes 488 671 g/m 2 (1.6 2.2 oz/ft 2 ) may be applied to the system prior to the application of standard meshes in accordance with the manufacturer s application instructions. 7. FINISH COAT: Apply Dryvit "DPR" finish, StoneMist, TerraNeo, Ameristone, LymeStone, Custom Brick, and smooth coatings over the base coat (Item 5) in accordance with the manufacturer s application instructions for the specific finish using stainless steel trowel. 8. OPTIONAL MECHANICAL FASTENING FOR EPS AND XPS INSULATION (Not Shown): Where supplemental mechanical fastening is to be used for restraining the insulation to substrate, mechanical fasteners with appropriate type and length of corrosionresistant fasteners and PBH Washers by Demand Products, Wind-lock Wind-Devil 2 plastic washers, or approved equivalent washer, can be used for penetrating through the insulation into the component substrate. Details of this installation can be found in the manufacturer s application instructions. Dryvit Systems Canada 29344 Rev: Mar 6 2018 3:52PM Uncontrolled Copy Page 10 of 10