Energy-Efficient Waste Water Treatment

Similar documents
Ohio Energy. Workshop G. Energy Efficiency Through Better Control: Maximizing the Energy Efficiency by Minimizing Waste

Ohio Energy. Workshop G. Best Practices in Energy Efficiency to Help You Reduce Your Energy Spend. Tuesday, February 21, :45 a.m.

Deep Dive Into Process Efficiency AEP November 14, 2017

How to Save Money and Become More Sustainable Through Energy Efficiency

Water and Wastewater Treatment Energy Savings Guide

ARE YOUR VARIABLE SPEED PUMPING APPLICATIONS DELIVERING THE PREDICTED SAVINGS? IMPROVING CONTROL TO MAXIMIZE RESULTS

Best Practice Pump Control

Energy Efficiency in Wastewater Treatment

2015 HDR, Inc., all rights reserved.

AR No. # Efficient Irrigation

Ditches for Energy Efficiency and Improved Nitrogen Removal

ESTIMATING ENERGY SAVINGS IN COMPRESSED AIR SYSTEMS

Aeration System Improvements with a 5-Year Payback. Scott Phipps

Water & Wastewater Operation: Pipe Systems, System Curves, & Pump Curves

Aeration System Optimization Can Offer the Greatest Long-term Savings

Reduce Grid Required Energy to Utilize Your Wastewater Treatment Facility

Aeration University Advanced Concepts in Energy Efficiency

Modeling and Simulation of Air Compressor Energy Use

Solids Management for Today s Wastewater Systems

O&M Energy Efficiency Checklist for Wastewater Treatment Plants

Benchmarking, Metrics Assessments, and Gap Analyses for Water and Wastewater

Outline. Introduction Case Studies. Anoxic Zone Mixing Channel Mixing. Theory and Criteria. Mixing Theory Design Criteria.

ENERGY BENCHMARKING OF WASTEWATER TREATMENT PLANTS SA WATER S EXPERIENCE

How to Use Your Existing SCADA for Energy Management. Don Best, HDR Engineering, Inc.

COMPREHENSIVE WASTEWATER TREATMENT/ WATER SUPPLY PLANT STUDY WORKSHEET

BEST PRACTICES FOR ENERGY EFFICIENT OPERATION OF WATER AND WASTEWATER SYSTEMS

Frequency-Conversion Transformation Plan for Nanning Sewage Treatment Plant

ENERGY CONSERVATION IN WATER AND WASTEWATER TREATMENT FACILITIES. WEF Manual of Practice No. 32. Prepared by the Energy.

Aeration Blower Requirements. Tom Jenkins 06/15/2016

Black River Wastewater Treatment Plant

The Schatz Energy Research Center

AERATION BLOWERS THEY ARE NOT ALL EQUAL Ken Brischke MWH 1801 California Street, Suite 2900, Denver CO, 80202

Sustainable Energy Management

Best practice in monitoring process, operation and maintenance of wastewater treatment plants 12 September 2011, Bucharest

Benchmarking Case Studies for Water and Wastewater Facilities

6.2.1 Intermediate Pumping Overview

W O C H H O L Z R E G I O N A L W A T E R R E C L A M A T I O N F A C I L I T Y O V E R V I E W

Energy Efficiency Modifications. Small Blowers D.O. Control and VFD s. Joe Cantwell Focus on Energy Kris August Kiel Wastewater Utility

SAF SAF SUBMERGED AERATED FILTER THE PARTNER OF CHOICE

Activated Sludge Treatment Extended Aeration (EA) and Sequencing Batch Reactor (SBR) Systems

Energy Reduction and Nutrient Removal in WWTPs Using Feed- Forward Process Control

Advanced Control in Water and Wastewater Systems

SECTION 2.0 WASTEWATER TREATMENT PLANT AND DISPOSAL SYSTEM DESCRIPTION

Planning for the Future Battle Creek s Approach to Upgrading its Secondary Treatment Processes

City of Andover, Kansas Energy Assessment-Wastewater Treatment Plant

The Undiluted Cost of Energy and Water: From Rainfall to Outfall. Greg Harrington Professor and Associate Chair

Dealing with Unexpected Wastewater Treatment Plant Disruptions. February 16, 2017

Altoona Westerly Wastewater Treatment Facility BNR Conversion with Wet Weather Accommodation

Life-Cycle Energy Costs and. Greenhouse Gas Emissions for Gas Turbine Power

2015 ISA Water / Wastewater and Automatic Controls Symposium August 4-6, 2015 Orlando, Florida, USA

Water and wastewater treatment operations

Jet Aeration Systems

Moving Toward Resource Recovery: Energy Management

Sustainable Solutions for Installation Water and Wastewater Infrastructure Presenter: Amy Santos ARCADIS/Malcolm Pirnie May 22, 2012

Compressed Air. How to Justify Projects and Achieve Significant Savings in Multiple Compressor Environments

Indicators for Minimizing Energy Consumption and GHG Emissions at Wastewater Treatment Facilities

Green Project Elements Using Innovative, Energy Efficient, Sustainable Design. GMWEA Spring Conference May 30, 2013

Pumps and Pumping Stations

Compact Waste Water Treatment MBR /MBBR Technology

Background on Energy Use in the U.S. Water and Wastewater Industry

The Superior Jet Aeration System

Session 2 Pump Selection. Mark Markham, P.E. Gresham, Smith and Partners September 14, 2017

Peerless Pump Company Handbook of Engineering Data

ONTARIO ROCK ROAD LIFT STATION EQUALIZATION FACILITY

Pilot Testing a High-Speed Turbo Blower at the City of Plano, Illinois Water Reclamation Facility"

Akiki Engineering Est.

Fact Sheet. Reducing Energy Usage in Water and Wastewater Treatment Facilities : A Tale of Two Cities

Pressure Booster System. Hya-Eco VP. Type Series Booklet

Conducting Successful Energy Audits for Both Water and Wastewater Utilities By: Rich Atoulikian, HDR

CITY OF OXFORD WASTEWATER TREATMENT FACILITY ANNUAL PERFORMANCE REPORT FOR THE CALENDAR YEAR OF 2018

Energy Efficiency / Conservation Case Studies in Waste Water Treatment Facilities

University Curriculum Development for Decentralized Wastewater Management

INCOMPRESSIBLE FLOW TURBOMACHINES Design, Selection, Applications,

Application Solution. Foreword. Figure 1. Affinity Laws for Centrifugal Pumps

Genesee County Drain Commissioner Division of Water & Waste Services District # 3 Water Resource Recovery Facility PATH TO ENERGY REDUCTION

PV Systems IV EE 446/646

Energy Optimization for WWTPs Saving Green by Going Green

Fremont Water Pollution Control Center Plant Expansion for Nutrient Removal and Wet Weather Flow Treatment

6. PUMPS AND PUMPING SYSTEM

REDUCING THE COST OF ELECTRIC ENERGY IN WASTEWATER TREATMENT. Thomas E. Jenkins, P.E. V.P. & General Manager ESCOR - Energy Strategies Corporation

Figure Trickling Filter

On: Effective Turndown of Aeration Air Blowers for Electricity Cost Savings

2015 HDR, Inc., all rights reserved.

HOW TO SAVE COSTS AND IMPROVE SUSTAINABILITY WHILE REDUCING EFFLUENT NITROGEN

BIOLOGICAL WASTEWATER BASICS

PAYBACK GUIDE CENTRIFUGAL PUMPS

Assuming 100 gallons per capita per day, and 3 people per REU, design flows for the development are proposed to be:

By Jack Wendler/Ripon WWTF

DESIGN AND OPERATION OF POROUS METAL CROSSFLOW MICROFILTERS

APS Pump & Blower Program.

City of Leadwood Wastewater System Engineering Report

ATTACHMENT 1 GENERAL FACILITY INFORMATION. BOD5 mg/l mg/l TSS mg/l mg/l NH3-N mg/l mg/l

Attachment N o F Control & Monitoring

WASTEWATER TREATMENT PLANT MASTER PLAN 6. BUSINESS CASE EVALUATION OF ALTERNATIVES

AQUAROBIC MINI-PLANT TM

SAF SAF SUBMERGED AERATED FILTER THE PARTNER OF CHOICE

SBR PROCESS FOR WASTEWATER TREATMENT

CHAPTER 12 TRICKLING FILTER PLANTS

A SIMPLE SOLUTION TO BIG SNAIL PROBLEMS - A CASE STUDY AT VSFCD S RYDER STREET WASTEWATER TREATMENT PLANT

Transcription:

Energy-Efficient Waste Water Treatment For American Electric Power May 17, 2017 Kelly Kissock, Ph.D., P.E. Director: University of Dayton Industrial Assessment Center 937-229-2835 kkissock@udayton.edu

Industrial Assessment Center Program Sponsored by U.S. Department of Energy (DOE) Began during 1970 s energy crisis 28 centers at universities throughout the U.S. 20 no cost assessments per year for mid sized manufacturers Goals Help industry be more resource efficient and costcompetitive Train new energy engineers Advance practice and science of energy efficiency

University of Dayton Industrial Assessment Center Conducted 970+ assessments since 1981 Savings opportunities: 12 Simple payback: 2 years Identified savings: 12% Implemented savings: 6%

All Waste Water Treatment Facilities Qualify for Free IAC Energy Assessment San Diego State IAC: 9 free WWT assessments 49 energy efficiency opportunities $3,278,437 per year in savings 1/3 implemented after 9 months. San Francisco State IAC 10 free WWT assessments 76 energy efficiency opportunities $3,746,308 per year in savings 2/3 implemented after 9 months. If interested contact Kelly Kissock, Ph.D., P.E. 937-229-2835 kkissock@udayton.edu

Waste Water Treatment Steps

Electrical Consumption Benchmark Data Energy consumption increases with level of treatment and decreases with plant influent level

Biggest Energy Users Pumping 15% Aeration 64% Activated Sludge Process

Electrical Power: W e W e = V P / [Eff pump x Eff drive x Eff motor x Eff vfd ] V = volume flow rate P = pressure gain to overcome inlet/outlet effects and friction Eff = efficiencies of pump/fan, drive, motor and VSD

Fluid Flow System Saving Opportunities Reduce pump P Employ energy-efficient flow control V Improve pump, motor or VFD efficiency

Reduce Pump P

Use Large Diameter Pipes W friction = V P friction P friction =k / D 5 W friction = V k / D 5 Work to overcome friction varies inversely with 5 th power of pipe diameter Doubling pipe diameter reduces pump power by: 1- (1/2) 5 = 97% 2 inch 18 ftwg 4 inch 0.6 ftwg

Use Smooth Pipes W friction = V P friction P friction ~ friction factor f f steel = 0.021 f plastic = 0.018 Plastic pipe reduces pump power by: (0.021 0.018) / 0.021 = 14% Material Roughness (m) Glass, plastic Smooth Copper, brass, lead 1.5 x 10 6 (tubing) Cast iron uncoated 2.4 x 10 4 Cast iron asphalt 1.2 x 10 4 coated Commercial steel or 4.6 x 10 5 welded steel Wrought iron 4.6 x 10 5 Riveted steel 1.8 x 10 3 Concrete 1.2 x 10 3

Use Gradual Elbows and Fittings W friction = V P friction P friction ~ loss coef k k std = 0.29 k long rad = 0.18 Long-radius elbows reduce pump power by: (0.29 0.18) / 0.29 = 38%

Minimize Elevation Gain: Increase Initial Reservoir Level W elev = V P elevation difference between inlet and outlet Reducing elevation difference reduces pump power by: (20 15) / 20 = 20%

Employ Energy Efficient Flow Control

Flow Control Systems designed for peak flow Systems operate at less than peak flow Use energy efficient method to control (reduce) flow

Energy Inefficient Flow Control By-pass Valve By-pass loop (No savings) Flow Control Valve (Small savings) Intermittent Flow (Proportional savings)

Energy-Efficient Flow Control Trim impellor for constant-volume systems VFD for variable-volume systems

Pump and System Curves P Pump Curve System Curve P 1 Operating Point W f = V P V 1 V

Bypass Flow: Zero Energy Savings P Pump Curve System Curve Wf at low flow requirement Wf at peak flow requirement V 2 = V 1 V When bypassing, V and P through pump are constant Bypass power = 100% of peak power Savings compared to peak = 0%

Throttling: Small Energy Savings Throttled System Curve P Design System Curve Wf at low flow requirement Wf savings Wf at peak flow requirement V 2 = V 1 / 2 V 1 V With throttling, V decreases but P increases Throttling power = 67% of peak power Savings compared to peak = 33%

Intermittent : Proportional Energy Savings P Pump/Fan Curve System Curve Wf at peak flow requirement Wf average Wf savings V 2 = V 1 / 2 V 1 V Pump operating time is proportional to flow Intermittent power = 50% of peak power Savings compared to peak = 50%

VFD : Big Energy Savings P Pump/Fan Curve System Curve Wf at peak flow requirement Wf savings Wf at low flow requirement V 2 = V 1 / 2 V 1 V Pump power is proportional to cube of flow Impellor/VFD power = (V 2 /V 1 ) 3 = (1/2) 3 = 12% of peak power Savings compared to peak = 88%

Flow Control Savings Summary at 50% Flow Bypass: 0% Throttling: 34% Intermittent: 50% VFD: 88%

Should Make Intuitive Sense Bypass (all the lights on, all the time) Throttling (pedaling bike hard with brakes on) Intermittent pump/fan operation (tortoise and hare)

Eliminate Intermittent Pumping: Pump Slow, Pump Long More energy to pump at high flow rate for short period than low flow rate longer Pump slow, pump long Example: Current: Two pumps in parallel for 10 hours/day Recommended: One pump for 11 hours/day Fraction Savings: 14%

Optimize VFD Control Most variable flow systems use pressure as control variable for VFD Savings depend on location and setpoint of pressure sensor Savings maximized when pressure is dynamically reset based on valve position

Variable Flow Pumping Control: Pressure Sensor at Discharge

Variable Flow Pumping Control P at Intermediate End Use

Variable Flow Pumping Control P at Most Remote End Use

Variable Flow Pumping Control Maximum Open Valve Pressure Reset

Variable Flow Pumping Control Summary P A B C D A: Pset,discharge (Worst) B: Pset,midway C: Pset,remote D: Pset,max valve (Best) V 2 = V 1 / 2 V 1 V

WWT Plants: Use Advanced Digital Sensors for Control Analog sensors age over time and lose calibration New digital sensors remain calibrated and transmit continuous data to improve control

IAC Experience with VFDs at WWT plants

Resize Over-sized Pumps Pump operating at offdesign point M at Eff = 47% Replace with properly sized pump at Eff = 80% Savings: 1-(.47/.80) = 41%

Refurbish Inefficient Pumps Pump impellors degrade over time Pump efficiency and capacity decline Mechanical refurbishment: +5.4% Sandblasting and coating: +6.2% Impeller coating: +1.5%

Resize Over-sized Motors Motor efficiency declines at low loads. Motor power factor declines at low loads.

IAC Experience with Oversizing at WWT Plants

Energy Efficient Motors

Motors: Energy Cost >> Purchase Cost Purchase and Energy Costs (20 hp motor at 8,000 hours/year over 20 years) 150,000 120,000 ($) 90,000 60,000 30,000 0 Purchase Energy 20-hp, 93% efficient motor costing $1,161 Motor 75% loaded, 8,000 hrs/year, $0.06 /kwh Annual energy cost = 20 hp x 75% x.75 kw/hp / 93% x 8,000 hr/yr x $0.06 /kwh = $5,806 /yr Over 20-yr life, energy cost is 100x greater than purchase cost!

1% Improvement in Efficiency Equals Purchase Cost Consider 20 hp motor, 93% efficient, 80% loaded, 6,000 hr/yr, 10 years Cost of electricity If efficiency = 93%, then 10 year electricity cost = $77,500 If efficiency = 94%, then 10 year electricity cost = $76,600 Savings = $77,500 - $76,600 = $900 Cost of motor Purchase cost = $1,000 Thus, Purchase premium efficiency motors!

Replace or Repair? Size Efficiency Cost Efficiency Cost Rew-Rep Rep-Rew S. P. (hp) Rewound Rewound ($) Engy Eff Engy Eff ($) ($/yr) ($) (yr) 1 73 220 84.6 275 68 55 0.8 5 82 330 89.8 432 191 102 0.5 10 84.7 500 91.7 686 324 186 0.6 15 85.5 550 92.6 911 484 361 0.7 20 87.3 600 93 1,071 505 471 0.9 30 88.2 760 93.8 1,553 731 793 1.1 50 90.6 980 94.4 2,482 800 1,502 1.9 60 90.8 1,116 94.8 3,280 1,004 2,164 2.2 75 91 1,320 95.3 4,476 1,339 3,156 2.4 100 91.2 1,650 95.4 5,645 1,738 3,995 2.3 150 91.8 2,400 95.5 8,624 2,279 6,224 2.7 200 92.3 2,650 95.7 10,680 2,771 8,030 2.9 250 92.9 2,860 95.8 13,043 2,933 10,183 3.5 300 93.1 3,080 96.1 14,084 3,621 11,004 3.0 500 92.8 4,400 96.6 25,725 7,630 21,325 2.8 Assuming 80% loaded, 6,000 hr/yr, $0.10 /kwh

Payback for Replacing Rather than Rewinding Motors Operating Hours: 4,000 hrs/year Simple Payback (Years) 10 9 8 7 6 5 4 3 2 1 0 $0.05 /kwh $0.08 /kwh $0.11 /kwh 0 50 100 150 200 250 Motor HP Source: US DOE Motor Master+ 4.0

Payback for Replacing Rather than Rewinding Motors Operating Hours: 8,000 hrs/year Simple Payback (Years) 10 9 8 7 6 5 4 3 2 1 0 $0.05 /kwh $0.08 /kwh $0.11 /kwh 0 50 100 150 200 250 Motor HP Source: US DOE Motor Master+ 4.0

WWT Plant Pumping Summary Treatment plants use multiple pumps to move water through treatment stages Minimize friction and lift Control flow with VFDs with advanced controls Right-size pumps and motors Repair degraded pumps Replace rather than repair motors

Aeration Systems Aerators maintain oxygen levels for aerobic digestion Aeration is typically most energy intensive processes: thus prime target for energy savings Three main types of aeration systems Activated Sludge Process

Mechanical Surface Aeration

Oxidation Ditch Aeration

Blowers push air through course, medium or fine pore aerators Diffused Air Aeration

Fine-pore Most Energy-Efficient Way to Add Oxygen to Water

Aeration Savings Opportunities Course to fine pore reduced blower energy by 30% with 24 month payback Replace 50% efficient positive-displacement rotary lobe blower with 70% efficient centrifugal blower Control aeration VFDs using Biochemical Oxygen Demand (BOD) Automatic DO control systems save 20-40% of aeration energy and usually prove cost-effective for activated sludge installations. Take aeration tanks out of service during periods of low flow, low organic loading, and/or high temperature.

Pre-treatment Savings Opportunities Sequence Influent Screen Blowers Based on Influent Flow

Disinfection Savings Opportunities Install a Low-Pressure High-Intensity Ultraviolet (UV) Radiation Disinfection System Match UV Lights to Flow

Solid Stream Treatment About 2/3 of plants use anaerobic digestion to break down solid sludge sediment Biogas produced as byproduct of solids stabilization is about 65% methane, and 35% CO 2 and can be burned. About 1/3 of plants use nitrification instead of anaerobic digestion to break down solid sludge sediment Waste treated by nitrification is great fertilizer

Solid Stream Saving Opportunities Pre-treat solid sludge with focused electric pulse to improve biogas output 3x to 6x ratio of energy produced as heat and biogas to electricity treatment with 4 year simple payback Use biogas to generate electricity or provide heat to maintain digester temperatures Sell waste treated by nitrification as fertilizer or burn for process heat

CO 2 Emission Abatement Potential Xylem

CO 2 Emission Abatement Potential Xylem Key findings: Significant emissions abatement does not require new technologies or carbon tax policy. All that is required is accelerated adoption and reinvestment in high efficiency technologies Primary barriers are awareness of opportunity and willingness to adopt solutions with higher capital investment but lower operating costs.

References and Photo Credits Recent Advancements in Wastewater and Water Treatment Technologies, C. Deppe and D. Kasten, IAC Directors Meeting, 2016 Energy Savings Opportunities in a Waste Water Treatment Facility, West Virginia IAC, 2016 Energy Efficiency Experience in Hawaii, A. Ganji, San Francisco State University IAC, IAC Directors Meeting, 2013 Energy Efficiency in Wastewater Treatment in North America_ A Compendium of Best Practices and Case Studies of Novel Approaches-WERF, 2011 Powering the Wastewater Renaissance: Energy Efficiency And Emissions Reduction In Wastewater Management, Xylem Inc., 2015 Following the Flow: An Inside Look at Wastewater Treatment, Water Environment Federation, 2009

Thank you! If interested in free energy assessment please contact: Kelly Kissock 937-229-2835 kkissock@udayton.edu