CCW MiraPLY Installation Instructions

Similar documents
WATERPROOFING. MiraPLY Installation Instructions SCIENCE. SERVICE. SOLUTIONS. Introduction. Description. Substrate Preparation. Features and Benefits

Start the installation at one corner of the building. Unroll the first sheet of MiraPLY-H square/parallel to the building wall, starting at one corner

WATERPROOFING. MiraPLYTM. -H with SeamLOCKSM. Technology SCIENCE. SERVICE. SOLUTIONS. Description. Typical Properties.

WATERPROOFING. MiraPLY -V with SeamLOCK Technology SCIENCE. SERVICE. SOLUTIONS. Standards. Description. Typical Properties.

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

SCIENCE. SERVICE. SOLUTIONS. WATERPROOFING. Waterproofing Solutions Overview

Section Pre-Applied Sheet Membrane Waterproofing

Pre-applied waterproofing membranes that bond integrally to poured concrete for use below slabs or behind basement walls on confined sites

Student Services & Classroom Addition

SECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING

PRODUCT DATA SHEET. Product Description

SECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING

PRODUCT DATA SHEET. Product Description

SECTION SELF-ADHERING SHEET WATERPROOFING CCW-711

G October 2018

PREPRUFE 300R LT & 160R LT

SECTION EPDM MEMBRANE WATERPROOFING

SECTION 07530CP EPDM MEMBRANE ROOFING

PREPRUFE Plus Low Temperature Membranes

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

SECTION SELF-ADHERING SHEET FLASHING

PROTECTO DECK INSTALLATION INSTRUCTIONS

INSTALLATION GUIDELINES PRECON

BENTONITE WATERPROOFING

PREPRUFE SCS Blindside waterproofing system for shotcrete foundation walls

ITEM 458 WATERPROOFING FOR STRUCTURES

EVOH PENETRATIONS INSTALLATION GUIDELINES PERMINATOR PLACEMENT

Installation Guidelines VBC Products

Rubber Roofing Pocket Application Guide

A. Product Data: Submit manufacturer s product data, with complete general and specific installation instructions, recommendations, and limitations.

ERSYSTEM ONESTEP PLUS

SECTION SELF-ADHERING SHEET MEMBRANE WATERPROOFING

MAKE ROOFS LAST LONGER

PREPRUFE 300R Plus & 160R Plus

Fully Adhered EPDM. Installation Instructions. Single-Ply Simplified

SCIENCE. SERVICE. SOLUTIONS. AIR & VAPOR BARRIER. Self-Adhering, Fluid-Applied Membranes & Flexible Flashings

SCIENCE. SERVICE. SOLUTIONS. AIR & VAPOR BARRIER. Self-Adhering, Fluid-Applied Membranes & Flexible Flashings

ACRYLIC Elastek #127 Solar One Plus

INSTALLATION GUIDELINES

1 PVC or ABS drain with strainer

BG SYSTEM Expansion joint installation in blind-side formed floors and walls.

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

Perm-A-Barrier VPS (Vapor Permeable Sheet)

Aussie Skin 550. Heavy Duty Below Grade, Blind-Side, Under-Slab Waterproofing Membrane. Delivery, Storage, and Handling

G October 2018

DURABILITY PUNCTURE RESISTANCE LONG TERM PERFORMANCE

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

INSTALLATION GUIDELINES - With VaporSeal Tape

INSTALLATION GUIDELINES

Aussie Skin 550. Heavy Duty Below Grade, Blind-Side, Under-Slab Waterproofing Membrane. Delivery, Storage, and Handling

UltraPly TPO SA. Product Information. Description: Membrane Preparation: Method of Application: Item Description

PART 1 GENERAL 1.1 SECTION INCLUDES. A. Below grade waterproofing and dampproofing 1.2 RELATED SECTIONS 1.3 REFERENCES

1. Clean the existing totally adhered or mechanically attached roof membrane: TPO, EPDM, Hyplon,

SECTION COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING


Architectural Roof and Wall Products Guide Specifications

Tools & Equipment Chalk line Caulk gun 50-75mm brushes 2 hand roller Hammer Hook blade knife/scissors Pencils

Fascia Systems. oofing 7.1

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

SECTION CCW-500R GREEN ROOF WATERPROOFING SYSTEM

FIRESTONE ULTRAPLY TPO SA APPLICATION GUIDE

Peel & Seal Self-Stick Roofing Solutions

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

B-1 DIRECT WATERPROOFING APPLICATION TO LAGGING FOLD OVER ARMORCLAY 1000 FOR GRADE LINE TERMINATION VERTICAL GEO-MAT C DRAIN 110 OR 150 FASTENERS

SELF-ADHERING SHEET WATERPROOFING

Architectural Roof and Wall Products Guide Specifications

SECTION (07100) - DAMPPROOFING AND WATERPROOFING

.2 Flashings at grade to extents shown on the Drawings. .3 Membrane and polyethylene slip sheets at perimeter of walls.

General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions.

GenFlex EZ TPO Peel & Stick SA (HW) APPLICATION GUIDE

GUIDE SPECIFICATION FOR MEL-ROL : ROLLED, SELF-ADHERING WATERPROOFING MEMBRANE

SikaProof Bentonite Plastic DPM overlap - Compacted Backfill Scale 1:5. Detail no: SB01 - Nov 2013

Installation Instructions ALUTRIX 600 ALUTRIX FR

A. The work of this section includes, but is not limited to, the following:

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Seal

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

OPEN SET SYSTEM. Easy-to-install Waterproofi ng Shower System. Installation guide

University of New Hampshire Scholars' Repository

BITUTHENE Deck System

S u b s t r u c t u r e W a t e r p r o o f i n g - Membranes.

AFM Anti-Fracture Membrane & AFM-WM Anti-Fracture Waterproofing Membrane Three-Part Specifications

Acrylic/Urethane. Metal Roof Restoration Sample Design Guideline

SECTION ADHERED SINGLE PLY MEMBRANE ROOFING

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

RoofKit Roofing Membrane Products:

SECTION SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT

March 2016 Replaces June 2013 Preprufe 160 Sheet Tanking and Waterproofing Membrane

SECTION ELASTOMERIC MEMBRANE ROOFING ADDENDUM 10 APRIL 20, 2011

Peel & Seal Self-Stick Roofing Solutions

SECTION FLEXIBLE FLASHING SYSTEM FOR MASONRY VENEER

Protecting Yourself from Heat Illness

D. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for waterproofing.

Ev erguard Adhesiv es Guid e. Updated: 3/ 17

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION

CCW 500R Green Roof Waterproofing System PART I - GENERAL

Transcription:

CCW MiraPLY Installation Instructions www.carlisleccw.com Support: 800.527.7092 Introduction Carlisle Coatings & Waterproofi ng Incorporated (CCW) has prepared this installation guide to assist applicators in the use of MiraPLY and accessories. Every project is different, and this is a guideline that may not cover every aspect for every project. Before commencing any work, the applicator must become familiar with all product installation procedures and all project conditions. System Description As a self-adhering, blindside waterproofi ng membrane, MiraPLY is a fully adhered composite composed of a tough, durable and fl exible TPO backing with a butyl alloy adhesive. MiraPLY comes in two different grades: MiraPLY-H, which is used for horizontal applications and MiraPLY-V, which is used for vertical applications. Advantages Blindside applications Positive-side applications Fully adhered membrane Seals around fasteners Tremendous impermeability and excellent resistance to chemicals (i.e., acids and bases) Quick and easy installation Unaffected by weather conditions Accessories SecurTAPE Pressure-Sensitive Elastoform Flashing CCW Detail Tape Sure-Seal HP-250 Primer EPDM Low-VOC Primer Sure-Seal Lap Sealant Universal Single-Ply Sealant A-1104 Butyl Sealant CCW-703V Liquiseal LiquiFiber Sure-Seal Termination Bar CCW MiraSTOP EJ-500 CCW MiraDRAIN Drainage Composite CCW MiraDRAIN HC Weathered Membrane Cleaner Sure-Seal Splice Wipes CCW Tie-Back Cover Substrate Preparation Gravel sub-base ¾" or smaller aggregate, level and compacted. Concrete working slabs must be level without any voids, honeycombing or protrusions. Lagging cannot have gaps larger than 1". If there are gaps larger than 1", the gaps must either be fi lled with grout or CCW MiraDRAIN Drainage Composite, or plywood must be installed. Shotcrete must be level without any voids, honey-combing or protrusions. MiraPLY-H Installation Start the installation at one corner of the building. Unroll the fi rst sheet of MiraPLY-H square/parallel to building wall starting at one corner with the TPO side down and the adhesive/release liner facing up with the Factory-Applied Tape (FAT ) on the side for the succeeding sheet to lap onto. Unroll the next sheet of MiraPLY-H and align parallel to and overlap the preceding roll of MiraPLY-H 3 (width of the FAT) and a minimum 6 end overlap. Stagger end laps. Ensure that the membrane lays fl at and no openings are visible. Make sure that the TPO side of the lap is clean, dry and free of contaminants. Leave plastic release liner on until ready for concrete pour or placement of rebar.

MiraPLY-V Installation Start the installation at one corner of the building. Unroll the fi rst sheet of MiraPLY-V and hang it square/parallel to building wall starting at one corner with the TPO side facing the soil retention system (lagging, sheet pile, shotcrete, etc.) and the adhesive/release liner facing out. Install a minimum of 4 fasteners across the top of the sheet and 12" on center in the lap. Fasten the fi eld of the MiraPLY-V with approximately 1 fastener per 2 ft 2 (not including fasteners in the seam). Unroll the next sheet of MiraPLY-V and align parallel to and overlap the preceding roll of MiraPLY-V 3" and a minimum 6" end overlap. Stagger end laps. Ensure that the membrane lays fl at and no openings are visible. Make sure that the TPO side of the lap is clean, dry and free of contaminants. Leave plastic release liner on until ready for concrete pour or placement of rebar. MiraPLY Repair Inspect the MiraPLY-H or -V membranes for damaged areas before placement of rebar or concrete. The membrane should be cleaned with a cloth dampened with water and the allowed to dry. Repair slices, cuts and small punctures (½" or less) with SecurTAPE, CCW Detail Tape or P/S Elastoform Flashing. Repair larger areas with a piece of MiraPLY extending beyond damaged areas by approximately 6" in all directions. Apply SecurTAPE to the cleaned TPO side of patch. Remove release liner of SecurTAPE, then position patch on damaged area and roll patch with fi rm hand pressure or position patch and apply CCW Detail Tape around all edges of patch and then roll with fi rm hand pressure. Concrete Placement Completely remove all release liners from MiraPLY and SecurTAPE. CCW recommends that the concrete should be installed within 60 days of membrane installation.

MiraPLY-H Side Lap w/ FAT Installation Install sheets of MiraPLY-H with minimum 3" side overlaps. Ensure the membrane lays fl at and no openings are visible. Stagger end laps. Make sure that the TPO side of the lap is clean, dry and free of contaminates and prime the TPO lap area surface with Sure-Seal HP-250 or EPDM Low-VOC Primer. Allow primer to fl ash off and dry. Remove the release liner on the FAT and join the sheets together while simultaneously applying fi rm hand pressure. After the seam is fully constructed, roll the seam with a hard rubber roller using fi rm hand pressure. Please Note: Clean seam area by using a clean rag to remove debris. If debris cannot be removed with a clean rag then Weathered Membrane Cleaner must be used. Weathered Membrane Cleaner coverage rate is approximately 1 gallon per 1,000 lineal feet of seam. Caution should be taken because solvent-based cleaners are extremely fl ammable and installers should read material safety data sheets and observe recommended safety procedures.

End Laps w/ SecurTAPE Install sheets of MiraPLY-H with a minimum 6" end overlap. Ensure the membrane lays fl at and no openings are visible. Make sure that the TPO side of the lap is clean, dry and free of contaminants and prime the TPO and butyl lap area surfaces with Sure-Seal HP-250 or EPDM Low-VOC Primer. Allow primer to fl ash off and dry. Position the 6" SecurTAPE in the lap area. Roll SecurTAPE using a hard rubber roller and fi rm hand pressure. Remove release liner on the SecurTAPE and join the sheets together while simultaneously applying fi rm hand pressure. After the seam is fully constructed, roll the seam with a hard rubber roller using fi rm hand pressure. Please Note: Clean seam area by using a clean rag to remove debris. If debris cannot be removed with a clean rag then Weathered Membrane Cleaner must be used. Weathered Membrane Cleaner coverage rate is approximately 1 gallon per 1,000 lineal feet of seam. Caution should be taken because solvent-based cleaners are extremely fl ammable and installers should read material safety data sheets and observe recommended safety procedures.

Side & End Laps Install sheets of MiraPLY-V with a minimum 3" overlap. Ensure the membrane lays fl at and no openings are visible. Stagger end laps. Make sure that the TPO side of the lap is clean, dry and free of contaminates and prime the TPO lap area surface with Sure-Seal HP-250 or EPDM Low-VOC Primer. Allow primer to fl ash off and dry. Remove the release liner on the lap (edge of the sheet) and join the sheets together while simultaneously applying fi rm hand pressure. After the seam is fully constructed, roll the seam with a hard rubber roller using fi rm hand pressure. Please Note: Clean seam area by using a clean rag to remove debris. If debris cannot be removed with a clean rag then Weathered Membrane Cleaner must be used. Weathered Membrane Cleaner coverage rate is approximately 1 gallon per 1,000 lineal feet of seam. Caution should be taken because solvent-based cleaners are extremely fl ammable and installers should read material safety data sheets and observe recommended safety procedures.

Horizontal/Vertical Transition Installation Start the installation at the side of the building. Unroll the fi rst sheet of MiraPLY-H square/parallel to the building wall, starting 6" above the grade, secure to wall and turn out onto the grade. Make sure membrane is tight to corner without voids. Fold and hand-roll MiraPLY, crease it to form corners and ensure that it does not bridge corners. The FAT should be at the grade side so the succeeding sheet can lap onto it. Unroll and install the next sheet of MiraPLY-H and align parallel to and overlapping the preceding sheet of MiraPLY-H by 3" min. (width of the FAT). Make sure that the butyl side of the lap is clean, dry and free of contaminants. Prime the butyl side of the MiraPLY-H that is turned up with Sure-Seal HP-250 or EPDM Low-VOC Primer and allow to fl ash off and dry. Install 6" SecurTAPE on the primed MiraPLY-H that is turned up. Roll SecurTAPE using a hard rubber roller and fi rm hand pressure. Install MiraPLY-V with the TPO side facing the soil retention system (lagging, sheet pile, shotcrete, etc.) and the adhesive/release liner side out so as to have a 3" minimum overlap onto the MiraPLY-H. Make sure that the TPO side of the lap is clean, dry and free of contaminants. Prime the TPO side of the MiraPLY-V that is overlapped onto the MiraPLY-H and allow to fl ash off and dry. Remove release liner of SecurTAPE and mate the MiraPLY-V to the MiraPLY-H, roll seam with a hard rubber roller and fi rm hand pressure. Leave plastic release liner on until ready for concrete pour or placement of rebar.

Slab Penetrations (Option 1) All penetrations must be secured to prevent any movement. Penetrations must be clean, dry and free from rust. Make sure that the Butyl side of the lap is clean, dry and free of contaminants. Cut a 4' x 4' piece of MiraPLY-H and cut a hole in the center the size and shape of penetration. Slide the 4' x 4' sheet over the penetration and remove plastic release liner. Apply Sure-Seal HP-250 or EPDM Low-VOC Primer to penetration and butyl portion of MiraPLY-H and let dry. Use CCW-1104, CCW Detail Tape or SecurTAPE to detail inside angle change to eliminate gaps and keep CCW-703V in place. Apply a 60-mil fi rst layer of CCW-703V 3" up penetration and 3" onto MiraPLY-H. Immediately place CCW LiquiFiber Reinforcing Fabric in the fi rst layer of CCW-703V. Apply 60-mil second layer of CCW-703V, fully covering reinforcing material. Above reinforced 120 mils of CCW-703V, wrap penetration with CCW MiraSTOP with a minimum 3" concrete coverage.

Slab Penetrations (Option 2) All penetrations must be secured to prevent any movement. Penetrations must be clean, dry and free from rust. Make sure that the butyl side of the lap is clean, dry and free of contaminants. Cut a 4' x 4' piece of MiraPLY-H and cut a hole in the center the size and shape of the penetration. Slide the 4' x 4' sheet over the penetration and remove plastic release liner. Apply Sure-Seal HP-250 or EPDM Low-VOC Primer to penetration and butyl portion of MiraPLY-H and let dry. Apply a 6" minimum P/S Elastoform Flashing, 3" minimum onto the primed penetration and then 3" minimum onto the primed MiraPLY-H. Install a stainless steel pipe clamp to secure P/S Elastoform Flashing to the pipe. Apply Sure-Seal Lap Sealant or Universal Single-Ply Sealant to the lap edges of P/S Elastoform Flashing. To ensure a watertight bond, roll P/S Elastoform Flashing with a hard rubber roller and fi rm hand pressure.

Vertical Installation Start the installation at the one end of the wall working from the base up the wall. Remove perforated release liner along edges and mechanically fasten the membrane vertically, using fasteners with plastic washer heads that are compatible with the substrate. The MiraPLY-V TPO side should be facing the substrate with the adhesive side/release liner facing the installer. Fasten lap seams every 12" on center. Fasten the MiraPLY in the fi eld of the membrane as required to keep membrane from blousing. Install the MiraPLY-V in suitable lengths for ease of installation. Install the next row of MiraPLY-V and align parallel to and overlapping the preceding roll of MiraPLY-V by 3". Make sure that the TPO side of the lap is clean, dry and free of contaminants and prime the TPO lap area surface with Sure-Seal HP-250 or EPDM Low-VOC Primer. Allow primer to fl ash off and dry. Mate the two sheets of MiraPLY-V together, making sure the lap is tight and secure without wrinkles. To ensure a watertight bond, roll P/S Elastoform Flashing with a hard rubber roller and fi rm hand pressure. Stagger end laps by approximately 12". Leave plastic release liner on until ready for concrete pour or placement of rebar. Cover fasteners with a 3" x 3" piece of SecurTAPE or CCW Detail Tape.

Wall Penetrations (Option 1) All penetrations must be secured to prevent any movement. Penetrations must be clean, dry and free from rust. Make sure that the butyl side of the lap is clean, dry and free of contaminants. Cut a 4' x 4' piece of MiraPLY-H and cut a hole in the center the size and shape of penetration. Slide the 4' x 4' sheet over the penetration and remove plastic release liner. Apply Sure-Seal HP-250 or EPDM Low-VOC Primer to penetration and butyl of MiraPLY-H and let dry. Use CCW-1104, CCW Detail Tape or SecurTAPE to detail inside angle change to eliminate gaps and keep CCW-703V in place. Apply a 60-mil fi rst layer of CCW-703V 3" up penetration and 3" onto MiraPLY-H. Immediately place CCW LiquiFiber Reinforcing Fabric in the fi rst layer of CCW-703V. Apply 60-mil second layer of CCW-703V, fully covering reinforcing material. Above reinforced 120 mils of CCW-703V, wrap penetration with CCW MiraSTOP with a minimum 3" concrete coverage.

Wall Penetrations (Option 2) All penetrations must be secured to prevent any movement. Penetrations must be clean, dry and free from rust. Make sure that the butyl side of the lap is clean, dry and free of contaminants. Cut a 4' x 4' piece of MiraPLY-H and cut a hole in the center the size and shape of the penetration. Slide the 4' x 4' sheet over the penetration and remove plastic release liner. Apply Sure-Seal HP-250 or EPDM Low-VOC Primer to penetration and butyl of MiraPLY-H and let dry. Apply a 6" minimum P/S Elastoform Flashing, 3" minimum onto the primed penetration and then 3" minimum onto the primed MiraPLY-H. Install a stainless steel pipe clamp to secure P/S Elastoform Flashing to the pipe. Apply Sure-Seal Lap Sealant or Universal Single-Ply Sealant to the lap edges of P/S Elastoform Flashing. To ensure a watertight bond, roll P/S Elastoform Flashing with a hard rubber roller and fi rm hand pressure.

Wall Terminations Terminate the MiraPLY-V with the Sure-Seal Termination Bar and Sure-Seal Lap Sealant. Make sure termination is below grade approximately 6". Install Sure-Seal Termination Bar by fastening the termination bar, compressing the MiraPLY-V to the concrete at 6" minimum on center with fasteners compatible with the termination bar and substrate. Cover top edge of MiraPLY-V and termination bar with Sure-Seal Lap Sealant. Carlisle Coatings & Waterproofing 900 Hensley Lane Wylie, TX 75098 800.527.7092 www.carlisleccw.com 604806 12.02.13 Carlisle and MiraPLY are trademarks of Carlisle. 2013 Carlisle.