PINLESS LCD MOISTURE METER WITH TRICOLOR BAR GRAPH USER S MANUAL

Similar documents
PINLESS LCD MOISTURE METER WITH TRICOLOR BAR GRAPH USER S MANUAL

DRS220. DRS220 Digital Refrigerant Scale Limited Warranty. Digital Refrigerant Scale

User Instructions for pin-less Ligno-Scanner S and Ligno-Scanner D

user guide CME4 concrete encounter 06/2014

VI-D4. Concrete Moisture Meter

Model 292A. Surface Resistance Test Kit. Instruction Manual

user guide CME4 concrete encounter

Manual No Revision MODEL GLI HAND-HELD/PORTABLE TOTAL/FREE CHLORINE METER

Sby SR Instruments, Inc.

User Instructions for Ligno-VersaTec Moisture Meter

Tracer TM Total Chlorine PockeTester Code 1740

Model M120 Mini Temperature/Humidity Meter

Concrete Encounter CME 4

Owner s Manual & Safety Instructions

WeighSouth. WBT Toploader Balance

INSTRUCTION MANUAL DAFM3

user guide SKIPPER PLUS non-destructive moisture meter for the marine industry

Model M130 Mini Anemometer

EP100 EMERGENCY POWER BANK

Elcometer Concrete Moisture Meter

Oyster ph - Conductivity - TDS - Temperature Meters

Concrete Encounter CME 4

NOVALYNX CORPORATION MODEL B & M-B EVAPORATION GAUGE TESTER INSTRUCTION MANUAL

F-2000H HAY AND HOPS MOISTURE METER. OPERATION MANUAL v3.6 DELMHORST EUROPE TITANIUMLAAN 100 THE NETHERLANDS

Limited Product Warranty

Moisture Meters For. Flooring

USER MANUAL. ExStik CL200A. Waterproof Total Residual Chlorine Tester. Patent Pending. Additional User Manual Translations available at

Xxxxx Xxxxxx OM-CP-TEMP101A. Temperature Data Logger with 10 year battery life INSTRUCTION SHEET MQS5026/0117

Safety Precautions. 3. Cabinet Assembly 4. Operating buttons / functions.5-6. Machine Operation

SAWDUST MOISTURE METER WTR-1E USERS MANUAL

Model E100 Gauss Meter

7 TFT LCD COLOR REAR VIEW SYSTEM

Cole Parmer Conductivity Meter

Moisture Content Meter for Wood and Building Material MC-160SA

WARNING ELECTRIC PALLET TRUCK EPT Revised A company dedicated to solving ergonomic and material handling problems since 1955.

DMC When Accuracy Counts

user guide CME4 concrete encounter

Turbidity Meter Instruction Manual

OM-CP-QUADPROCESS 4-Channel Low Level DC Current Data Logger. OM-CP-OCTPROCESS 8-Channel Low Level DC Current Data Logger INSTRUCTION SHEET

TEST & MEASUREMENT TOOL LIMITED WARRANTY Every Test & Measurement Tool is warranted for five (5) years from the date of purchase *.

OM-90 SERIES Portable Temperature and Humidity Data Loggers. Shop online at omega.com

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

Opti-Check Handheld Fluorometer

user guide MEP moisture encounter plus

Instruction Manual HI Portable ph/ec/tds/ C Meters

DS-520 Digital Indicator Operation Manual 73366

AUTOMATIC FOLDING DOOR

WAGNER MODEL L722 "STACK PROBE" ATTACHMENT

Model 10A. Model 20A. Operating Manual. ECG Simulator. ECG / Arrythmia Simulator

F owners manual. TestEquipmentDepot.com WHEN ACCURACY IS THE POINT.

RJE INTERNATIONAL, INC. STI- 350 R EV 2.2

Introduction Specifications Control Panel / Remote Unit Diagrams Setting Up the Unit Maintaining the Unit Safety info / Warnings Warranty Information

SQ-1 ROOF TRUSS WEG-IT TABLE

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

DICKSON TH8 DICKSON. Temperature & Humidity Chart Recorder Operation. Useful Features. Applications & Product. Specifications. Product.

Effective This guide supersedes all previous versions

User's Guide. ExStik CL200A. Waterproof Total Residual Chlorine Tester Patent Pending

ENMET Corporation PO Box 979 Ann Arbor, MI GS-24-DF. Manual October 2003 MCN-314, 12/05/03

User s Manual. June 23, 2017 P/N Revision D. TURNER DESIGNS 1995 N. 1 st Street San Jose, CA Phone: (408) FAX: (408)

OWNERS MANUAL. Micro TPI Field Portable Turbidimeter

DRYWALL DOLLY 900 LB. CAPACITY

WARNING! Read all of the information in this booklet, and any relevant Application Notes, before using the Eco Sensors DO3.

TABLE OF CONTENTS. Electromatic Equipment Co. Inc. -8- Electromatic Equipment Co. Inc. -1-

MODEL NUMBER: 1419 SERIES

Circular Expansion Cement Curing Kit Instruction Manual

TABLE OF CONTENTS. Section Paragraph Title Page. ADDENDUM Visual Index Quick Reference. 1 General Information 1-1

Quick Start TIME mode Set Time... 4 Set Alarm... 5

Breath Simulation Module

PHS-3D-01 Lab ph Meter. User s Guide. Shanghai San-Xin Instrumentation, Inc.

SAUTER TB-US, TB-US-red Version /2017 GB

BC Series Compact Counting Scale INSTRUCTION MANUAL

Pallet Jack 4,400 Lbs Capacity Model #31001

ECH 2 O EA-10. Soil Moisture Sensor. Integrator s Guide

Instruction Manual. Model 2831D. 4 ½ Digit True RMS Digital Multimeter

INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL

DATA LOGGER Model DL-SA11

This product has been tested and certified to conform to ASTM F2456, Youth Resistant Firearms Container.

1.0. Post Install Kit. For Use With All Vinyl Railing BOM V1 1/13. Owner's Manual. Assembly and Installation Instructions.

Instruction Manual C20

testo 616 Appareil de mesure de l'humidité

Universal Tactical Light

Installation Guide. Single AC or Dual AC Sump Pump Installation. 1 AC Primary Pump or 2 AC Pumps with Auxiliary Alternator

MAKING MODERN LIVING POSSIBLE INT. Danfoss Link RS. Installation Manual. Danfoss Heating

BD-2100 BUILDING MATERIALS MOISTURE METER OPERATION MANUAL. DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s-hertogenbosch THE NETHERLANDS

F owners manual WHEN ACCURACY IS THE POINT.

General Terms and Conditions for Laminate Warranties

Model 3185E DUAL TONE DECODER INSTRUCTION MANUAL

HY-ALERTA 500 Handheld Hydrogen Leak Detector

Moisture Encounter Plus User Guide

Royal Sovereign RSL 2701 Laminator

Model Instruction Manual

BD-10 BUILDING MATERIALS MOISTURE METER OPERATION MANUAL DELMHORST EUROPE TITANIUMLAAN 100 THE NETHERLANDS

Pallet Gate Installation Instructions and Operators Manual

F-6/6-30. owners manual. TestEquipmentDepot.com WHEN ACCURACY IS THE POINT.

Coating Thickness Gauge Model: AX-CTG10 User s Manual

SQ-1 INTELLIGENT ROOF

INSTALLATION & OPERATION INSTRUCTIONS ICW-3 WINDOW INTERCOM

92831 TEL: (714) FAX:

Consort MANUAL HANDLEIDING MODE D EMPLOI D230

Transcription:

PINLESS LCD MOISTURE METER WITH TRICOLOR BAR GRAPH USER S MANUAL MM8 Please read this manual carefully and thoroughly before using this product.

TABLE OF CONTENTS Introduction................................. 2 4 Key Features................................... 4 Product Overview................................ 5 Setup Instructions............................... 6 Install Battery............................. 6 Operating Instructions............................ 6 Measurement Tips............................ 6 7 Specifications............................... 7 8 Warranty Information............................. 8 Return for Repair Policy........................... 8 INTRODUCTION Thank you for purchasing General Tools & Instruments MM8 Pinless LCD Moisture Meter with Tricolor Bar Graph. Please read this user s manual carefully and thoroughly before using the instrument. The MM8 is designed for use in woodworking, water damage restoration, building construction and home renovation. Examples include: Checking for moisture on or below the surface of carpets and subflooring Measuring the moisture content of wood, drywall or masonry before painting, wallpapering, sealing or treating Locating water leaks above ceilings, below floors or behind walls Selecting dry lumber The meter is a non-invasive (pinless) instrument that can detect moisture up to 3/4 in. (19mm) below the surface of the following materials: wallboard, masonry, hardwood and softwood. It infers the level of moisture from the material s capacitance, which the meter measures by gauging its effect on an electric field that the meter generates each time it is powered on. 2

The meter exploits two physical phenomena to make its measurements: 1. The linear relationship between a solid material s moisture level and its dielectric constant and therefore its capacitance. 2. The so-called fringing-field effect the slight spreading of the electric field produced by current flowing between two electrodes when both electrodes are on the same side of a material. Behind the top of the MM8 are two metal plates. When the meter is powered on, the plates are given small and opposite charges. The potential difference causes current to flow, creating a three-dimensional electric field. When the top of the meter is placed against one side of a material with moisture on or slightly below its surface, the increased capacitance of the material distorts the electric field to an extent that can be sensed (as a change in flux over the sensing area) and measured. Displayed readings reflect the average moisture level of the material between its surface and the electric field s maximum penetration of 3/4 in. Moisture closer to the surface has a greater effect on readings than moisture at the maximum penetration depth. The MM8 has been calibrated at the factory for use with wallboard, masonry, hardwood and softwood. The capacitance of wood and the capacitance of building materials are affected differently by moisture because they have different densities. The meter compensates for density by adjusting the gain of its internal sensing circuitry. The MODE button on the front of the meter provides a convenient way to switch among the four materials. The name of the material selected appears on the LCD. Below the LCD is a bank of colored LEDs that roughly mirrors the digital reading above it in bar graph format, with green indicating dry, red indicating wet, and yellow indicating an intermediate moisture level. An audible out-of-range alarm (beeper) sounds whenever wood is tested and found to have a moisture content above 17%, or when drywall or masonry is found to be more than 70% wet. Although the LCD displays measurements of drywall and masonry moisture content as % readings, these are actually relative readings with no accuracy specification. Despite that shortcoming, relative readings are useful for quickly comparing the moisture levels of materials, or the wetness of different areas of the same material. For example, you can use the meter to locate the source of 3

a water leak above a ceiling by comparing readings at various points on it. If the ceiling is level, the point that produces the highest reading is below the source of the leak. Any digital reading can be held by pressing the HOLD button on the front of the meter. This button makes it possible to make a measurement in a dark place and display it after bringing the meter into a lighted area. To extend battery life, the MM8 automatically powers off after two minutes of inactivity. The instrument is powered by a 9V battery included in the blister pack. KEY FEATURES Separate settings for drywall, masonry, softwood and hardwood 2 in. diagonal high-contrast, white-on-black backlit LCD + 3-color LED bar graph Non-invasive, non-marring detection technology with 3/4 in. (19mm) maximum sensing depth ±4% accuracy on wood Calibrates automatically or manually Reading HOLD button 2-minute Auto Power Off trigger Separate out-of-range alarms for wood and building materials Low battery indication Powered by 9V battery (included) 4

PRODUCT OVERVIEW Fig. 1 shows all of the controls, indicators and physical features of the MM8. Fig. 2 shows all possible display indications. Familiarize yourself with the position and function of all components before moving on to the Setup Instructions. Fig. 1. The controls, indicators and physical features of the MM8 C A B D G E A. High-contrast, white-on-black LCD B. LED bar graph; mirrors digital reading on LCD C. MODE button. Cycles through four target options: Wallboard, masonry, softwood and hardwood Fig. 2. All possible MM8 display indications F D. HOLD button. Freezes and releases digital readout. Also used to silence out-of-range alarms E. button. Powers meter on and off F. Battery compartment G. Inductive sensing area A. Moisture reading B. Low battery indication C. Drywall mode D. Masonry mode E. Softwood mode F. Hardwood mode G. Held reading indicator H. Moisture unit. Expressed as a percentage to make it easy to compare readings. All readings are relative. 5

SETUP INSTRUCTIONS INSTALL BATTERY Open the battery compartment at the bottom of the meter (Fig. 1, Callout F) and push the included 9V battery inside the compartment with the connector facing in and following the polarity as indicated on the compartment. Close the compartment after installing the battery. OPERATING INSTRUCTIONS To power on the meter, press and hold the button (Fig. 1, Callout E) for at least three seconds. (To power off the meter, follow the same instruction.) To measure the moisture level of drywall, masonry, hardwood or softwood, press the MODE button until the name of the target material appears on the LCD (WALL is short for drywall). Then scan the material by gently pressing the inductive sensing area (Fig. 1, Callout G) on the top of the meter against the material. The LCD will display the material s moisture content as a percentage. Simultaneously, one or more bar graph LEDs will illuminate to place the material s moisture level within a spectrum bounded by dry and wet. The color of the illuminated LED furthest to the right indicates which % band contains the material (see the Specifications section on p. 7 for the bands boundaries). To hold a reading, press the HOLD button briefly. The display will show the held value, along with a lock icon above the % sign. If the reading is above the alarm limit for that material, pressing the HOLD button will silence the alarm. MEASUREMENT TIPS For maximum accuracy, press the sensing area against a flat area of a representative sample of the target material. The sample s length and width should be at least as large as the dimensions of the inductive sensing area: 1.6 x 1.6 in. (40 x 40mm). Ideally, the material should also be at least 3/4 in. thick. That is the meter s maximum measurement depth and the thickness it is calibrated for. If your sample is too thin, the meter will measure material beneath it as well and produce an inaccurate reading. One way to compensate for thin samples is to stack them. Measurements of wood are skewed by two variables: ambient humidity and the 6

density of the wood species. The best way to compensate for the effect of these variables is to develop your own moisture level curves, based on your experience working with different species of wood on a day-to-day basis. Although the MM8 auto-calibrates each time it is powered on, the meter can be manually calibrated. Perform a manual calibration whenever the meter cannot produce a reading, or if multiple measurements of the same sample produce very different readings. To manually calibrate the MM8: 1. Power the meter on and hold it in one hand with the top in the air. Make sure your fingers are not touching or near the inductive sensing area. 2. Press and hold the HOLD button until the display reads 101. Then release the button; this will change the reading to 102. Wait a few seconds. When the reading changes to 000, calibration is complete. SPECIFICATIONS Measurement Ranges 0 to 53% for softwood 0 to 35% for hardwood Relative readings for wallboard and masonry Measurement Accuracy ±4% for hardwood and softwood Maximum Sensing Depth 3/4 in. (19mm) (in wood) Inductive Sensor Size 1.6 x 1.6 in. (40 x 40mm) Out-of-Range Alarm Levels >17% for wood >70% for drywall and masonry LCD Size 2 in. (51mm) diagonal with three 0.5 in. (13mm) high digits Display Resolution 1% Bar Graph Composition 3 each green, yellow and red LEDs LED Bands For drywall and masonry: green = 0 to 30%, yellow = 31 to 70%, red = >70% For wood: green = 5 to 14%, yellow = 15 to 17%, red = >17% Auto Power Off Trigger 2 minutes of inactivity Operating Temperature 32 to 104 F (0 to 40 C) @ 5 to 95% R.H. Storage Temperature 14 to 122 F (-10 to 50 C) 7

Dimensions Weight Power Source 6.3 x 2.8 x 2.9 in. (160 x 70 x 73.5mm) 4.7 oz. (132g) without battery (1) 9V battery (included) WARRANTY INFORMATION In the U.S, General warrants its instruments and accessories, and digital tools against defects in material or workmanship for one year from the date of purchase unless otherwise stated on the packaging, manual, and/or marketing materials. General also warrants its non-digital tools products against defects in material or workmanship on a limited lifetime term. The company will replace or repair the defective unit, at its option, subject to verification of the defect. This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the product. Any implied warranties arising from the sale of a General product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. General shall not be liable for loss of use of the product or other incidental or consequential damages, expenses, or economic loss, or for any claim of such damage, expenses, or economic loss. State laws vary. The above limitations or exclusions may not apply to you. RETURN FOR REPAIR POLICY Every effort has been made to provide you with a reliable product of superior quality. However, in the event your instrument requires repair, please contact our Customer Service to obtain an RGA (Return Goods Authorization) number before forwarding the unit via prepaid freight to the attention of our Service Center at this address: General Tools & Instruments 75 Seaview Drive Secaucus, NJ 07094 212-431-6100 Remember to include a copy of your proof of purchase, your return address, and your phone number and/or e-mail address. 8 GENERAL TOOLS & INSTRUMENTS 75 Seaview Drive Secaucus, NJ 07094-1806 PHONE (212) 431-6100 FAX (212) 431-6499 TOLL FREE (800) 697-8665 e-mail: sales@generaltools.com www.generaltools.com MM8 User s Manual Specifications subject to change without notice 2018 GENERAL TOOLS & INSTRUMENTS NOTICE - WE ARE NOT RESPONSIBLE FOR TYPOGRAPHICAL ERRORS. MAN# MM8 02/23/18