Bioclimatic building regulations for warm-dry climates

Similar documents
Thermal Comfort and Energy Performance of Social Housing in Hot-Dry Climates

Comparative Analysis of the Thermal Behavior between Cellular Concrete Blocks and Stabilized Earth Blocks as Wall Materials

CHAPTER 6 CONCLUSION

Adaptive Thermal Comfort in Warm Dry Climate: Economical dwellings in Mexico

Design Strategies and Guide lines for Tropical Coast of Pakistan, Using Climate Consultant

Arch 463 ECS Fall Midterm I. 30 Multiple Choice Questions

Potential of innovative daylighting and passive cooling systems for achieving luminous and thermal comfort in commercial buildings

PASSIVE SOLAR BUILDING DESIGN STRATEGIES IN LALITPUR, POKHARA AND DHARAN CITIES OF NEPAL

Thermal Response of Dwellings in Northwest Mexico: Applying passive design strategies

Designing outdoor spaces with COMFORT-EX

171: An urban office designed for the southern Brazilian climate

Case Study: Bio-Climatic Building Design for Tropical Climates

Influence of Building Orientation on the Indoor Climate of Buildings

Energy rehabilitation of social housing for rent, as demonstrator in the LIFE New4Old Project

Energy consumption and thermal comfort in a passive house built in Romania

Energy saving in a dry climate and vertical housing

Using passive solutions to improve thermal summer comfort in timber framed houses in South-west France

Design of Sunshade Board with South External Window of Residential Building in Hangzhou Based on Software Simulation Analysis of Energy Saving

PALM TREE RESIDENTIAL AREA / Hanoi, Vietnam

Simulation and Energy Analysis of Thermal Environment of Unassisted Passive Solar House

Chapter 7. Passive Solar Contents

BUILDING DESIGN AND THERMAL INERTIA: WHEN, WHY, WHERE

Bioclimatic Design Approach Integration into Architectural Design: a Library Case Study

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

A Comparative Study of the Thermal Comfort of Different Building Materials in Sana a

NORTH PROJECT AQABA, JORDAN. Recommended Energy Efficiency and Renewable Energy Measures for the Premium Villa

Examination and Assessment of the Environmental Characteristics of Vernacular Rural Settlements in Varying Topographies in Cyprus

INCREASE THE VALUE AND COMFORT OF YOUR HOME. Saving Energy, Saves Money. and lower monthly costs with energy efficiency features.

PLANNING FOR DURABILITY IN BUILDING PROJECTS: STRATEGIES AND TECHNICAL RECOMMENDATIONS ACCORDING TO LEED CANADA

10 tips from your Architect

546: High Altitude Design, Optimising Residential Architecture in the Alborz Mountains, Iran

ENERGY ANALYSIS AND ENERGY CONSERVATION OPTION FOR THE WAREHOUSE FACILITY AT THE HUMAN SERVICES CENTER COMPLEX DRAFT REPORT.

ENERGY SAVING INNOVATION IN CHINESE TRADITIONAL BUILDINGS. L. Zhu Nanjing University of Technology China

1104; 2 Autonomous University of Yucatan (UADY), Faculty of Engineering, Department of Construction, Av.

capacity) can absorb solar energy. This thermal energy is re-emitted in all directions as

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

ANALYSIS OF ENVELOPE THERMAL BEHAVIOUR THROUGH PARAMETRIC STUDIES. Civil Engineer, PhD, Assistant Professor, Civil Engineering Department (3)

Passive House Project documentation

ENERGY CODES IN COUNTRIES WITH MILD CLIMATES HIGH POTENTIAL FOR INTERNATIONAL ENERGY SAVINGS

INTENT OBJECTIVES HISTORIC DESIGNATIONS

Local Implementation of Building Energy Policies in China's Jiangsu Province

A study on the energy efficency of libraries of the west and tejo valley region in portugal

Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Non-Residential Passive House Buildings

Thermal Comfort in Architecture

Available online at ScienceDirect. Energy Procedia 57 (2014 )

Open Access The Impact of Cool Roofs on Energy Consumption of Office Buildings in Chongqing of China

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Research on indoor thermal environment of stilted buildings in Chongqing, China

SHELTER FOR COMPOSITE CLIMATE

Västra Balltorp Mölndal, Sweden

Energy and Lighting Performance of Buildings in the Neighbourhood Ciudad de los Angeles, Before and After Refurbishing.

317: Thermal performance of houses located in Florianópolis, southern Brazil

POST OCCUPANCY DESIGN INERVENTION TO IMPROVE COMFORT AND ENERGY PERFORMANCE IN A DESERT HOUSE

GREEN BUILDING CONGRESS 2011 NEW DELHI

Principles of Green Architecture

Nocturnal natural ventilation for low and zero energy office buildings in Central Chile

Designing for Queensland s climate. Designing for Queensland s climate

St Loyes Extra Care Facility PHPP Pre-Assessment Report

Green Façades for Urban Comfort Improvement Implementation in a extreme Continental Mediterranean climate

Bioclimatic approaches of modern residential architecture in Cyprus,

GLASOASE MORE TIME OUTSIDE: EXTEND YOUR PATIO SEASON WITH GLASOASE

ARCH-MEDES (I) CONSULTANTS PVT. LTD. Green Park Delhi

ENERGY EFFICIENT TECHNIQUES AND SIMULATION OF ENERGY CONSUMPTION FOR THE SHANGHAI ECOLOGICAL BUILDING

Thermal Environment of Chinese Residential Buildings with Different Thermal Insulation Materials in Hot-Summer-and-Cold-Winter Zone of China

Framework document for the ECOWAS directive for Energy Efficiency in Buildings Table of contents

DYNAMIC FACADE. BUILDING ENERGY EFFICIENCY REHABILITATION.

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

A first look at the affect of outdoor planting on the indoor environment of St. Loyes Residence. David Coley. March 2011 Internal Document 776

Potential of passive design strategies using the free-running temperature

RoboRater. Jim Woolcock Director, Sustainability House

Energy consumption simulation of the prototypical building for optimizing the orientation of building model in the simulated environment

447 - Thermal Performance of Residential Buildings in Lisbon with Large Glazing Areas

Special Features of Energy Conservation in Historical Buildings

Thermal comfort conditions in outdoor spaces

Building Energy Consumption Analysis, Energy Saving Measurements and Verification by Applying HAP Software

Planning Rationale. A) Family Oriented Development

Evaluation methods for indoor environmental quality assessment according to EN15251

Learnings from residential PH design and procurement in Australia. Luc Plowman

SOLAR PASSIVE DESIGN: PRINCIPLES AND PRACTICE

THE IMPACT OF BUILDING ORIENTATION ON ENERGY USE: A CASE STUDY IN BUNG HATTA UNIVERSITY, INDONESIA

Reducing energy demand in non-domestic buildings: integrating smart facades, ventilation, and surface heating and cooling

COOL BARRIER RESIST* High Solar Reflective Water Resistant Flexible Dust Resistant Waterbased

Effect of Building Orientation and Window Glazing on the Energy Consumption of HVAC System of an Office Building for Different Climate Zones

PRINCIPLES AND POTENTIALS OF VENTILATIVE COOLING

siting, building and design guidelines April 2017 Newgate, Tarneit Design Guidelines

The Role of Energy Codes in Public Policy. A White Paper by the Northwest Energy Codes Group

Workshop: Architecture-Tradition and Modernization. Climate Responsive Urban Design

Applications of ECOTECT and HEED in building energy analysis - Case study: A typical tube house in Hanoi

Danish national plans for Nearly Zero Energy Buildings

Passive Cooling Strategies in Greening Existing Residential Building in Hot Dry Climate: Case Study in Bahrain

Partnership of European Regions on Energy Efficiency in Buildings Opportunities for economic, social, environmental and territorial development

Modeling the Brillhart House

Impact of Cooling Strategies on Energy Reduction

Thermal Characteristics of a Vernacular Building Envelope

Section 3.8.2, Regional Initiatives: update section on San Mateo County Green Building Ordinance to reflect ordinance language.

Radical POTENTIAL!! COMFORT ZONE WHAT IS IT? WHAT DOES IT HAVE TO DO WITH GREEN BUILDING + ZERO CARBON?

Design and retrofitting of a hybrid building in Athens

Model Home 2020 project i CarbonLight Homes

Results from the Application of the Maltese Energy Performance Rating of Dwellings in Malta EPRDM Software to a New Block of Apartments

Research on the Urban Heat Island (UHI) Effect: Current Status and Future Development

Achieving the nearly zero energy building concept - A study based on practical experience

Transcription:

Eco-Architecture V 25 Bioclimatic building regulations for warm-dry climates J. M. Ochoa 1, A. Duarte 1, I. Marincic 1, A. Gomez 2 & A. Figueroa 3 1 Department of Architecture and Design, University of Sonora, Mexico 2 University of Colima, Mexico 3 Autonomous Metropolitan University, Mexico Abstract In Mexico, regulations on energy efficiency in buildings are in the early stages and have been poorly mixed among the different actors involved in the building processes. This situation results in the fact that economically disadvantaged people cannot have access to comfortable and energy efficient environments. This problem becomes worse in the northern regions of the country, which require air conditioning, because of the dry warm climate, for several months of the year. A proposal of a technical standard about bioclimatic buildings for warm-dry climates is presented in this paper. Also, the process for its development is described. This involves monitoring and analysis of typical dwellings in Hermosillo city in northwest México, a hot-dry climate location. The proposed regulation aims to reduce the environmental impact of the construction industry and energy use in buildings, by incorporating mandatory, optional and incentivized requirements to improve energy efficiency and the building s habitability. The proposal develops a set of articulated provisions in three main areas: efficient energy use; environmental comfort; vegetation with low water consumption in urban areas. It is intended that these regulations will apply to all new buildings, expansions and major refurbishments, once they have been incorporated into municipal regulations. Keywords: bioclimatic architecture, warm-dry climate building, energy efficiency, bioclimatic regulations. doi:10.2495/arc140031

26 Eco-Architecture V 1 Introduction Currently in the field of architecture and urbanism in Mexico, there are large gaps in rules and regulations, especially on the issue of energy efficiency and environmental comfort in buildings appropriate for each climate region. Progress in technology of environmental conditioning enables architects to have the freedom to follow trends and construction practices of other cultures and places, often without considering any adaptation to the climate of the site, and ignoring regional building and design practices, even in the extreme hot-dry northern climates of Mexico. The consequence is that there is no responsibility of architects to maintain comfort conditions inside the buildings, leaving all the work to artificial environmental conditioning systems, which as sophisticated, efficient or smart as they are, do not always meet their goal, and additionally generate very high energy consumption. In 2009 Bioclimatic Architecture Network (BAN) was established based on the convoking of the Secretariat for Higher Education of Mexico for the formation of Thematic Academic Networks. The BAN constituted three groups of specialized research in the area of bioclimatic architecture: University of Colima, Atzcapotzalco Autonomous Metropolitan University and the University of Sonora. The network aims to advance in the generation and application of knowledge in areas such as habitability and energy efficiency in buildings and their regulatory aspects from the perspective of bioclimatic architecture. The BAN worked on the project: Norms and regulations for Bioclimatic Architecture, whose main objective is the proposed regulation described in this paper. 2 Methodology As a first step an analysis of current regulations and their possible effects on the activity of design and construction of buildings preferably in areas with a hot climate was performed. Also consultations and surveys were carried out to users, building professionals, authorities and academics about knowledge of the regulations and good practices of bioclimatic construction. A field study was conducted to find out the local construction practices and systems that enable climate adaptation. The study tried to cover various types of selected homes, both contemporary and traditional style houses. Case studies were monitored and analysed according to international standards. Finally, a bioclimatic analysis was conducted to define the criteria and design guidelines.

Eco-Architecture V 27 3 Case study location and climate The standard was created using the example of the city of Hermosillo as a location of a hot-dry climate. 3.1 The climate of Hermosillo The city is the capital of the state of Sonora. It is located in the north-western zone of Mexico, 275 km South of the U.S. border and 2,037 km from Mexico City, at 29 05 North latitude. High solar radiation levels, clear skies and daily and annual high temperature swings are typical of the local climate. The maximum air temperature exceeds 38 C on an average of 90 days of the year, including most days from early June until early September, with minimum air temperatures of 20 25 C and maximum about 40 44 C. Air temperatures, in extreme cases, can reach up to 50 C. Average relative humidity oscillates between 50 and 15%; however, the arrival of moist air in August makes it feel a little bit humid (Figure 1). The warm season extends for 5 or 6 months per year, and the use of airconditioning is necessary inside buildings during this period. Winters are comfortable, with minimum temperatures of 4 7 C and maximum between 25 and 30 C. The city has almost 300 sunny days per year; in spring and summer, solar radiation can rise up to 1000 W/m 2. The rainfall is scarce; with an annual total precipitation of 225 mm. August is the wettest month of the year (27 mm). AH 15 Comfort A J A S J 10 J F D N M A O M D J S F J N M A O M J 5 DBT( C) 5 10 15 20 25 30 35 40 45 Figure 1: Maximum and minimum monthly average temperature and relative humidity of the site, plotted on the psychometric chart.

28 Eco-Architecture V 3.2 Urban environment and housing Despite the harsh environmental conditions, the new areas of the city are neither planned well nor prepared for the hot-dry desert climate. This situation contrasts with the historic old town, which consists of narrow streets, plenty of adobe houses with small windows, vegetated central patios, arcades and light colours. Recently developed districts have wide streets, large paved areas, and detached buildings. New housing developments, even economic or high-income houses are designed with the same criteria for the mild climate of central regions of Mexico; as a consequence, there is a huge energy consumption during the warm period. For the study, 25 model homes, representing 21% of the new homes available for sale in the city during 2011 were analysed. The constructed area of the house goes from 21 to 120 m 2, the most repetitive pattern (71%) have an area between 45 and 60 m 2, and it s known as minimum housing. Figure 2 shows some facades of minimum houses. Figure 2: Main facade of a minimum house that was analysed. A north south orientation of the main elevation prevails in most units. Walls are made of concrete hollow blocks finished with latex paint generally in light colours.

Eco-Architecture V 29 The roof system consists of precast beams and polystyrene panels that function as a framework for a thin layer of reinforced concrete that is poured on top. As a final finish the roof has a waterproof membrane of white elastomeric polymer with high reflectance, recommended for the plentiful solar radiation of the region. None of the openings has any kind of solar protection or shading device. Regarding the exterior areas, in most cases the house does not have any paving material and it does not have any sunscreen or trees. In rare cases the inhabitants have modified these conditions, mainly because of economic restrictions. Due to summer climatic conditions, most users utilize some kind of air conditioning system to ensure their comfort. The most commonly found is an evaporative cooler system, known locally as cooler. This system is preferred over other air conditioning systems, because compared to an A/C unit, the cooler costs less and is mechanically simple to repair and maintain. Some disadvantages are that it requires the use of water to operate and does not work well in temperatures over 40ºC. In addition, when the highest temperatures occur, relative humidity increases because of the rainy season, decreasing the cooling effect. There are also individual air conditioning systems that are installed in a window or wall opening, as well as mini-split air conditioners. These are usually located in the bedrooms, complemented by a regular fan, commonly found in the livingdining area. Responding to the problem of high-energy consumption, people have come up with creative but ingenuous solutions, which are more or less effective and sometimes quite expensive in relation to the benefits they offer. For example: windows covered with polystyrene plates and aluminium foil or other reflective film; polyurethane applied copiously on walls and roofs, and in extreme cases doors and windows that are closed permanently. Considering the extreme climate conditions, architectural design criteria must be adapted and applied stringently in order to minimize the negative climate effects on the occupants and their energy consumption. 4 Proposal for a technical standard on bioclimatic construction Mexican laws aim to safeguard costs, quantities and characteristics in the design, production and service of consumer goods between entities and individuals, particularly those in widespread use and readily available to the public. There are two basic types of norms in Mexican law, the Mexican Official Standards (NOM, its acronym in Spanish) and the Mexican Standards (NMX, its acronym in Spanish). Only the NOM standards are mandatory, while the NMX standards only express a recommendation of parameters and procedures. If a NMX standard is mentioned as part of a NOM standard it becomes mandatory [2]. Since specifications and design recommendations are proposed in the field of urban and architectural design, as well as building spaces for human use, we propose a complementary technical standard to make this type of norm mandatory in Mexico, which must be integrated in the municipal regulation for construction.

30 Eco-Architecture V The municipal regulation dictates the minimum safety and habitability requirements for all buildings. The complete proposal of the standard, as well as other supporting documents can be viewed on the BAN website [3]. 4.1 General objective The Complementary Technical Standard on Bioclimatic Construction aims to reduce the environmental impact on construction, buildings and their usage by incorporating obligatory regulations that improve the efficiency of energy and habitability. 4.2 Field of application This standard will be mandatory in the municipalities in which it is implemented. It will include a variety of activities for land developments and building constructions, and it will cover new projects, renovations and changes of use for buildings of public and private use, with the objective of improving human activities. However, in certain circumstances the literal fulfillment of any section may be omitted, as long as justified technical reasons are submitted and accepted by the Municipality, in addition to taking compensatory measures to achieve the intended objective. 4.3 Focus of the technical standard on bioclimatic construction The technical standard develops, in an articulated manner, a set of rules in three main areas related to building and urban space: efficient energy use; environmental comfort; vegetation with a low consumption of water in urban zones. 4.3.1 Efficient energy use This approach includes urban and architectural planning and building based on bioclimatic criteria. Energy efficiency is achieved by two approaches: the use of advanced technology and efficient facility design in accordance with the Mexican Standards (NMX) and the Mexican Official Standards (NOM), and secondly through an efficient urban and architectural design that applies bioclimatic recommendations. All Mexican Standards related to energy issues are available on the website [4]. 4.3.2 Environmental comfort Environmental comfort refers to the conditions, both climatic and those generated by the interaction of people with the natural and built environment, which should be the appropriate ones for human performance of daily activities. Environmental comfort relates to thermo-hygrometric, visual and acoustic conditions. 4.3.3 Vegetation with low water consumption in urban areas This section focuses on the use of vegetation associated with building and public spaces, enhancing its beneficial climatic effects and encouraging low water

Eco-Architecture V 31 consumption. The proposal s information is based on the empirical background of the research group, as well as previous studies and project specifications. 5 Content and structure of the technical standard on bioclimatic construction This technical standard consists of 16 items: 1 transient and 2 annexes, which are divided into 6 chapters. 5.1 Chapter I: general considerations This chapter contains 4 articles that explain the content, objectives, scope and enforceability of the technical standard; general concepts essential to better understand the content. 5.2 Chapter II: urban project considerations 5.2.1 Street design This article takes into account the main factors involved in urban design with a bioclimatic focus: ventilation, street and lots orientation, street layout, secondary streets and housing subdivision. 5.2.2 Procedures to reduce the impact of the urban heat island In order to reduce overheating of urban areas, which promotes increased power consumption and thermal discomfort, the application of urban design procedures to mitigate the effect of the heat island on urban areas will be discussed. The following aspects will be covered: flooring and coatings; elements of artificial shading; urban vegetation. 5.3 Chapter III: considerations for projects with bioclimatic building This chapter covers all aspects that should be considered to achieve projects that are more comfortable and energy efficient in the building process, by taking into account issues such as the shape, proportion and orientation of buildings in relation to the environment. This chapter includes 9 articles. 5.3.1 Shape and compactness For isolated buildings or houses, the ideal plant shape is rectangular, with the largest axis oriented in the east-west direction exposing north and south façades. Compactness (C) should be as low possible. Compactness is defined as the ratio between the volume V (m 3 ) by the thermal envelope content and the sum of the surfaces S (m 2 ) of the envelope, according to the equation: C = V / S (m). 5.3.2 Orientations It is mandatory to orient one of the main façades south or north (with a maximum deviation of ± 40 ). Larger deviations will be accepted only in existing buildings

32 Eco-Architecture V and lots that inevitably constrain the orientation. Some measures should be implemented to reduce the drawbacks of excessive deviation regarding the optimal orientation. 5.3.3 Thermal insulation This section refers to the maximum heat transfer indicated in the current Official Mexican Standards NOM-008-ENER-2012 [5] and NOM-020-ENER-2011 [6]. Recommendations will be made to determine the heat transfer by taking into account the heat capacity of building materials, and making calculations using a thermal simulation program. 5.3.4 Openings and protections This article refers to the design and calculation of the openings and devices for the protection and delimitation of the gains from solar radiation suitable for each orientation and climatic region. Recommendations will also be made for building design and materials, with the purpose of implementing devices capable of resisting the local climate characteristics (corrosion, UV radiation, dust, wind and pests). The calculation of the sun protection factor and the maximum area of windows and skylights should be performed according to the proposals of the NOM-008- ENER-200 [5] and NOM-020-ENER-2011 [6]. 5.3.5 Passive solar gain New buildings must include a quantitative assessment of winter solar gains, which will be achieved by means of passive solar systems. It is recommended that the solar collection devices take into account sun protection during the hot season. 5.3.6 Natural lighting In addition to windows, overhead lighting will be considered as a way to get a uniform distribution of natural light. The lighting provided by windows and skylights will provide the highest possible percentage of the requirements necessary to properly perform the activities meant for each area, which will then be complemented by artificial lighting devices. 5.3.7 Ventilation It is mandatory that all buildings have the capability to allow crossed ventilation. In the cases where this is not possible, interior ventilation ducts will be used. Buildings for residential use with a unique exterior that don t allow crossed ventilation will not be accepted unless compensatory measures are taken to minimize adverse consequences on comfort and hygienic deficiencies due to ventilation. These measures must not add more power consumption and must be justified accordingly. 5.3.8 Outdoor areas This article establishes that all public and private outdoor spaces, whether they are transient or permanent use areas, should be shaded during the season with the

Eco-Architecture V 33 highest insolation, either with vegetation or other devices such as pergolas and sunshades, or a combination of both. In outdoor parking spaces, at least 50% of the area must be shaded with a combination of sunshades and trees. Shadow projection must be calculated to ensure vehicle and user protection from the sun. Crosswalks with sun protection must also be provided to ensure comfortable movement of people within the outdoor parking space. 6 Evaluation of the implementation of the technical standard To verify that the standard is accomplished, an evaluation form has been created. These forms contain the aspects that must be covered by each article and the required evidence, as well as the points awarded for its completion. The points assigned to each aspect will be weighed according to the needs and particularities of each climatic region and the characteristics of each city where it is to be applied. The evaluation system considers four possibilities in the evaluation: o Compliant; o Partially compliant; o Does not comply; o Not applicable. To obtain the points from the criteria it is necessary to either be compliant or not applicable, depending on the project. On cases with not applicable, a technical study will be given with equivalent alternatives. 7 Conclusions In the case of design and building construction for human use, each municipality is in charge of regulating aspects of design and construction related to the minimum hygro-thermal and lighting comfort, as well as the efficient use of energy, but is very poorly defined and there is no clear methodology available to evaluate them. However, some initiatives include the publication of the Official Mexican Standards like NOM-008-ENER-2001 [5] and NOM-020-ENER-2011 [6] that regulate energy efficiency in non-residential buildings and housing but these standards only restrict heat transfer through the building envelope, given a limited number of design strategies, focusing almost exclusively on the thermal resistance of the building materials. These emerging standards, along with others that regulate the manufacture of air conditioning equipment, luminaires and energy efficiency in outdoor lighting, are the beginning of specific energy legislation. Unfortunately, there is a long way to go for the application of these regulations in Mexico. In a recently applied survey, only a small percentage of architects and civil engineers, of the total sample, knew or had heard of them and no one had put them into practice, despite some having been in operation for more than 10 years.

34 Eco-Architecture V On the other hand, its application is not mandatory until the regulations are reflected by the local building codes. Aware of this need, the Bioclimatic Architecture Network has made a legislative proposal focusing on three main areas related to building and urban space: efficient energy use; environmental comfort; vegetation with low water consumption in urban spaces. This proposal is made using the existing format for Supplementary Technical Standards, giving the proposal the possibility of joining the local building regulations in force without requiring major modifications. Certainly, this is not enough, besides the proposal, it is necessary to implement a verification system, as well as training and professional development program so that stakeholders can apply it properly. This way, value will be added to projects and users will have comfortable buildings with reduced operating costs and an overall better quality of life. References [1] Marincic I, et al. La construccion actual de viviendas en Hermosillo y su adecuacion al clima por medios pasivos. In Memorias de la XXXV Reunion Nacional de Energia Solar, ANES, Chihuahua, Mexico. October 2011, pp. 189 193, 2011. [2] Huerta O. Las Normas Oficiales Mexicanas en el ordenamiento jurídico mexicano. Boletín Mexicano de Derecho Comparado, Nr. 92, May August, 1998. ISSN 0041 8633. Mexico. Online: http://www.juridicas.unam.mx /publica/rev/boletin/cont/92/art/art4.htm [3] Red Temática de Arquitectura Bioclimática. Thematic Network on Bioclimatic Architecture website, Mexico: http://www.lema.arq.uson.mx /rab/ [4] National Commission for the Efficient Use of Energy (CONUEE) Official Mexican Standards on energy efficiency, online: http://www.conae.gob.mx /wb/conae/cona_1002_nom_publicadas_vigen [5] Secretaría de Energía. Official Mexican Standard NOM-008-ENER-2001, Energy efficiency in buildings, nonresidential building envelope. Diario Oficial, 25 de abril de 2001, segunda sección, 2001, Mexico. [6] Secretaría de Energía. Official Mexican Standard NOM-020-ENER-2011, Energy efficiency in buildings, building envelope for residential use. Diario Oficial, 29 de agosto de 2011, primera sección, 2011, Mexico. [7] Secretaría de Energía. Official Mexican Standard NOM-023-2010-ENER, Energy efficiency of air conditioners with a split system, test methods and labeling. Diario Oficial, 20 de diciembre de 2010, primera sección, 2010, México. [8] Secretaría de Energía (2007, 06). Official Mexican Standard NOM-011-2006- ENER, Energy efficiency of air conditioners with a central system, test methods and labeling. Diario Oficial, 22 de junio de 2007, primera sección, 2007, México.