Optima 8x00 Series. ICP Optical Emission Spectrometers

Similar documents
Optima 8x00 Series. ICP Optical Emission Spectrometers

EXPAND YOUR RANGE EXTEND YOUR RESOURCES. Avio 500 ICP Optical Emission Spectrometer

AMAZINGLY CAPABLE REMARKABLY AFFORDABLE. Avio 200 ICP Optical Emission Spectrometer. For research use only. Not for use in diagnostic procedures.

Image Area YOUR PRESCRIPTION FOR USP 232/233 COMPLIANCE. USP 232 / 233 Readiness Solutions and Services Overview

OPTIMA 4000 DV Series of ICP-OES Systems

PinAAcle 500. Flame Atomic Absorption Spectrometer

PinAAcle 900 Series. Atomic Absorption Spectrometers

NO INTERFERENCE BETWEEN YOU AND BETTER THROUGHPUT. NexION 1000 ICP Mass Spectrometer. For research use only. Not for use in diagnostic procedures.

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

ICP Expert software. Technical Overview. Introduction

ESI SC-FAST Sample Introduction Solutions for PerkinElmer ICP-OES and ICP-MS Systems

Analysis of steel and its alloys using the GB/T standard and an Agilent 5100 ICP-OES in dual view mode

Chromera Speciation Software The Right Tool for the Right Answer. ICP-Mass Spectrometry. Key Benefits

AxION 2 TOF MS. Time-of-Flight Mass Spectrometer

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

Avio 200 ICP-OES Flat Plate

Benefits of running organic matrices using the Agilent 5100 ICP-OES fast, robust, high performance analysis

Accurate. Robust. Reliable. AGILENT 710 SERIES ICP-OES

Accurate. Robust. Reliable. AGILENT 710 SERIES ICP-OES

Increase productivity for environmental sample analysis using the SVS 2+ Switching Valve System for Agilent 5100 SVDV ICP-OES

DO THINGS THE WAY YOU WANT. NexION 300 ICP-MS Three modes of operation. Two interference-removing techniques. One revolutionary instrument.

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions

Analysis of Mineral and Heavy Metal Content in Beverages Using the Teledyne Leeman Labs Prodigy Plus ICP-OES

Analysis of Trace Metals in Surface and Bottled Water with the Optima 7300 DV ICP-OES

Introducing the new Agilent 7800 Solution-Ready ICP- MS. Agilent Technologies 2015

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

The Determination of Alloying Elements in High-Carbon Steel using Radially Viewed Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES)

Ultra-fast ICP-OES determinations of base metals in geochemical samples using next generation sample introduction technology

High performance radio frequency generator technology for the Thermo Scientific icap 7000 Plus Series ICP-OES

ACCURACY THE FIRST TIME. Bring Your Esoteric Assays In-House Routinely SCIEX DIAGNOSTICS MASS SPECTROMETERS

Thermo Scientific icap RQ ICP-MS. Simplicity, productivity and robustness for routine labs

High matrix tolerance of the Thermo Scientific icap 7000 Plus Series ICP-OES with the radial Ceramic D-Torch and the sheath gas adaptor

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

USABILITY BY DESIGN Every component of the Agilent 7900 ICP-MS is engineered for performance and reliability

DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

TurboMass GC/MS Software

World-leading LC/MS/MS technology for quantitation and identification API LC/MS/MS System

ACCURACY THE FIRST TIME. Reliable testing with performance, productivity and value combined AB SCIEX 3200MD SERIES MASS SPECTROMETERS

The Agilent Atomic Spectroscopy portfolio for Environmental applications AA, MP-AES, ICP-OES, ICP-MS & ICP-QQQ

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II AA Mercury Analyzer

API 3200 LC/MS/MS system

SMALL SIZE BIG POTENTIAL. STA 6000 / 8000 Simultaneous Thermal Analyzers

Table I: MCL and MRL Concentrations for Contaminants Monitored Under the Safe Drinking Water Act National Primary Drinking Water Regulations

TurboMatrix. Thermal Desorption Solutions

HELPING YOU DETECT ENVIRONMENTAL THREATS WITH A WORLD OF EXPERTISE. Environmental Solutions

Trace Metals in Waters by GFAAS, in Accordance with U.S. EPA and Health Canada Requirements

Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Altus UPLC IT S ALL ABOUT PEAK PERFORMANCE

Analysis of wear metals and contaminants in engine oils using the 4100 MP-AES

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

ICP-OES. Varian Vista-MPX CCD Simultaneous ICP-OES

DO MORE AND DO IT WITH CONFIDENCE. Empower 3 Chromatography Data Software

Product Descriptions and Offerings

SMS 100 MERCURY ANALYZER SMS 100. Mercury analysis directly on solid samples from the undisputed leader in Atomic Spectroscopy

TGA 8000 Thermogravimetric Analyzer BETTER CHARACTERIZATIONS START WITH BETTER CONTROL

Ultima Expert Ultimate ICP-OES Spectrometer Best Performance & Ease-of-Use

SPECTROGREEN ICP-OES ANALYZER. A new view of analyzer technology and value

Multi-Element Analysis of Trace Metals in Animal Feed using ICP-OES

Ultima Expert Ultimate ICP-OES Spectrometer Best Performance & Ease-of-Use

CLARUS SQ 8 GC/MS. Gas Chromatograph/Mass Spectrometer

Agilent 720/725 ICP-OES RELIABLE. PRODUCTIVE. ROBUST.

CLINICAL MASS SPECTROMETRY DATA MANAGEMENT SOFTWARE FROM SAMPLE COLLECTION TO RESULT MSMS WORKSTATION SOFTWARE

REQUEST FOR TENDER. Supply of a Dual View (radial & axial) ICP-OES instrument Issue date 04 July 2014 Briefing session Closing date and time

Perkin Elmer HGA-600/ HGA-700 Graphite Furnaces

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES

Agilent 7900 ICP-MS RAISE YOUR EXPECTATIONS WITH THE NEXT GENERATION OF ICP-MS

Composition Analysis of Animal Feed by HR ICP-OES

Analysis of Heavy Metals in Iron-based Fertilizers by HR ICP-OES

IR READY TO GO. Spectrum Two FT-IR Spectroscopy

TO RESULT SOFTWARE DATA MANAGEMENT MASS SPECTROMETRY FROM SAMPLE COLLECTION MSMS WORKSTATION SOFTWARE

Increased Sample Throughput for ICP-OES Applied to U.S. EPA Method 200.7

Confident Quantitation

Direct Analysis of Photoresist by ICP-MS. Featuring the Agilent Technologies 7500s ICP-MS

The next generation FT-NIR spectrometer. Innovation with Integrity FT-NIR

Thermo Scientific Insight 2 Software for Evolution 200 Series UV-Vis Spectrophotometers. Comprehensive solutions Simplified workflows

Accuracy and Precision. Dilution Error in Error in Factor Accuracy Precision 200 <2% <2%

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Thermo Scientific GENESYS 10S Bio spectrophotometer

PROCUREMENT PROCEDURE OF CPRI (NON WORKS) Dt of Revision : Issue Dt. :

Attenuated Total Reflectance (ATR)

Automating EPA 6020 Compliant Analysis with the Agilent 7900 ICP-MS and ESI prepfast Autodilution System

Eco Plasma Innovative Inductively Coupled Plasma Technology

Functionality. Normal Operation

GOOD LABORATORY PRACTICE Agilent Cary 8454 UV-Visible Spectroscopy System

US EPA Method using the Thermo Scientific icap 7600 ICP-OES Duo

Tender Document. National Centre of Excellence in Analytical. Chemistry, University of Sindh, Jamshoro. Inductive Coupled Plasma (ICP -OES) ISSUED BY:

Fluorescence & UV- Visible Workshop

Agilent 7900 ICP-MS RAISE YOUR EXPECTATIONS WITH THE NEXT GENERATION OF ICP-MS

ABSTRACT. This study investigates the use of inductively coupled plasma-optical emission spectrometry

Agilent 6490 Triple Quadrupole LC/MS System REACH ULTIMATE SENSITIVITY WITH BREAKTHROUGH IFUNNEL TECHNOLOGY

Thermo Scientific icap 6000 Series ICP Emission Spectrometer

Using a Diode Array UV-Vis in Regulated Environments

Utilizing Glow Discharge in Optical Emission Spectroscopy

Determination of 22 Elements Following US EPA Guidelines with a New Megapixel CCD ICP-OES

Agilent Resources for Workflow Compliance MEASURING ELEMENTAL IMPURITIES IN PHARMACEUTICAL MATERIALS

Transcription:

Optima 8x00 Series ICP Optical Emission Spectrometers

ENVIRONMENTAL Easy to use and engineered for exceptional throughput and detection limits, the Optima 8x00 series helps maximize productivity and profitability. Built-in environmental methods for quicker start-up Dual view capability allows measurement of high and low concentrations in the same run for enhanced productivity Torch cassette low maintenance, simple operation eneb delivers 2-4x detection limit improvement to more easily meet regulatory requirements GEOCHEMICAL Designed to deliver reproducible accuracy even with complex matrices, the Optima 8x00 series offers unsurpassed performance without compromising sample throughput. Flat Plate plasma technology lowers operating and maintenance costs WinLab32 Multicomponent Spectral Fitting superior interference correction for more accurate results Simultaneous data acquisition for maximum sample throughput PHARMACEUTICAL/NUTRACEUTICAL With the lowest detection limits of any ICP-OES and a full suite of enhanced data security features, the Optima 8x00 series makes it easy to comply with stringent regulatory requirements. Detection of full list of elements for transition to USP 232/233 WinLab32 for ICP Enhanced Security for 21 CFR Part 11 compliance eneb delivers 2-4x detection limit improvement to keep up with evolving regulatory requirements FOOD/PRODUCT SAFETY With a range of revolutionary technologies, the Optima 8x00 series offers unsurpassed flexibility for handling a variety of sample types and matrices. Flat Plate plasma technology improves robustness for many different matrices PlasmaCam aids in method development and productivity WinLab32 for ICP software designed to deliver rapid method development 2

With its groundbreaking features and expanded capabilities, the Optima 8x00 series is more than just an evolution of the world s most popular ICP-OES it s a revolution. Continuing PerkinElmer s long history of excellence and leadership in ICP technology, the Optima 8x00 series carries on a tradition of offering the best resolution and linear dynamic range. More significantly, the 8x00 series delivers a level of stability and detection limits never before seen in an ICP instrument. Built around the proven design of the Optima platform and controlled with our industryleading, Windows 7-compatible WinLab32 software, the 8x00 series will change the way you look at ICP-OES. The line s breakthrough performance is the result of a series of cutting-edge technologies that optimize sample introduction, enhance plasma stability, simplify method development, and dramatically reduce operating costs. REVOLUTIONARY TECHNOLOGY SPECTACULAR RESULTS eneb Sample Introduction The most efficient and consistent sample introduction system available. By generating a constant flow of uniform droplets, the eneb option enables Optima to deliver superior stability and unsurpassed detection limits ideal for environmental and pharmaceutical labs. Flat Plate Plasma Technology A patented RF generator featuring maintenance-free plasma induction plates in place of the traditional helical load coil. With no cooling required and reduced argon consumption, operating costs are dramatically lowered. PlasmaCam Viewing Camera By offering continuous viewing of the plasma, this integrated color camera simplifies method development and enables remote diagnostic capabilities for maximum uptime. Ideal for high-throughput contract labs in food/product safety and geochemical. www.perkinelmer.com/optima8x00 3

Laboratories have very different definitions of what it means to get the most out of their ICP. But whether your priority is precision or reliability, flexibility or stability, speed or simplicity, you ll find the ideal solution in the Optima 8x00 series. Reduced argon consumption with Flat Plate plasma technology With PerkinElmer s patented Flat Plate plasma technology, the same robust, matrix-tolerant plasma is generated and maintained with almost half the argon consumption of helical load-coil systems. Maintenance-free, this whole new approach to RF generation minimizes operating costs without compromising performance. Flat Plate plasma technology is designed to run at 8 liters/minute plasma gas flow at any RF power, allowing for robust plasma conditions. 2-4x better detection limits with eneb sample introduction system With the revolutionary eneb (electronic nebulizer) system, samples can be introduced into the Optima far more effectively and efficiently than ever before. Engineered around a precision-manufactured inert aerosol head, eneb produces exceptionally consistent droplets no more than 6 microns in diameter. These small, uniform droplets can be dried, atomized and ionized more quickly and consistently for detection limits 2-4x better than those attainable with other sample introduction systems. Pneumatic Nebulizer eneb Electronic Nebulizer Ideal for all sample types including those with high levels of dissolved solids eneb's aerosol head is manufactured from a rugged, long-lasting inert polymer, delivering exceptional matrix tolerance, acid resistance, and precision. 120000 100000 80000 Signal 60000 40000 20000 0 Pb 220nm ICP Background 220.25 220.30 220.35 220.40 220.45 λ (nm) By producing small, uniform droplets without the use of a high-pressure gas stream, eneb s analyte signals increase 2-4x more than the background for exceptional detection limits. 120000 100000 80000 60000 40000 20000 0 220.25 220.30 220.35 220.40 220.45 λ (nm) 4

ENGINEERED TO DELIVER PROVEN PERFORMANCE Advanced optical system ensures superior detection limits Engineered for enhanced light throughput, the optical system on Optima instruments delivers superior detection limits, simplifying compliance with U.S. EPA, EN and DIN regulations. Unsurpassed stability and analytical accuracy are ensured through either Dynamic Wavelength Stabilization (model 8000) or a thermally stabilized optical system (model 8300). Patented dual viewing of the plasma enhances productivity Elements with high and low concentrations can be measured in the same run for superior throughput and efficiency. Axial viewing provides the lowest detection limits while radial viewing with variable viewing height permits extended working ranges and eliminates ionization effects. Unique, shear gas system eliminates interferences By removing the cool tail plume of the plasma, this innovative technology eliminates interferences. Since it uses air instead of expensive high extraction systems or cones that tend to clog and require cleaning, the system is maintenance-free, improves performance and enables a greater linear dynamic range. Removing the tail plume also minimizes the need to add expensive ionization suppressants. Adjustable, quick-change torch cassette simplifies maintenance and optimizes performance Simple to adjust (with no tools) even while the ICP is running, Optima s torch cassette makes it easy to optimize performance, even with the most difficult samples. For added flexibility, the instrument is compatible with a variety of nebulizers and spray chambers, including eneb, Scott/Cross Flow and Cyclonic/Meinhard options. Two high-performance SCD (Segmented-array Charge-coupled Device) detectors improve accuracy Available on the Optima 8300, the detectors provide superior resolution and performance across the entire wavelength range (with one for UV, the other for Vis), reducing interferences and improving accuracy. www.perkinelmer.com/optima8x00 5

Flat Plate plasma technology Generates a robust, maintenance-free, matrix-tolerant plasma using half the argon of traditional load-coil technologies. eneb Delivers the best signals, stability, and detection limits of any built-in sample introduction system available on an ICP-OES. Adjustable torch cassette Makes it easy to optimize performance even with the most difficult samples and offers simple maintenance. Patented dual view Offers radial and axial viewing of the plasma for effective measurement of elements with high and low concentrations in the same method. Shear gas system Removes the cool tail plume of the plasma to eliminate interferences and minimizes the need for ionization suppressants. With no cones to clean or expensive high extraction systems, the use of shear gas is maintenance-free and optimizes performance in the axial view. 6

Select the model that best addresses the needs and priorities of your laboratory Maximum Throughput Fastest Warm-Up Universal Data Acquisition Time-Resolved Data Acquisition Smallest Instrument Footprint Optima 8000 X X Optima 8300 X X X WinLab32 for ICP software Provides all the tools to analyze samples, report and archive data, and ensure regulatory compliance with an optional Enhanced Security package. PlasmaCam Enables continuous viewing of the plasma for simpler method development and remote diagnostic capabilities. Two SCD detectors Deliver superior resolution across the entire wavelength range, reducing interferences and improving accuracy, offering truly simultaneous data acquisition (Optima 8300). Autosamplers Optimize productivity with a choice of compatible models including the PerkinElmer S10 and a variety of other sample-introduction system options. www.perkinelmer.com/optima8x00 7

To complement its many new hardware innovations, the Optima 8x00 series features an equally impressive array of software enhancements making it faster and easier than ever to go from sample to results. The Windows 7-compatible industry-leading WinLab32 for ICP software simplifies every step of your workflow before, during and post analysis. Easy to set up and get started Simple method development Use the software s built-in methods for added speed and simplicity, or follow four easy steps to create your own. Either way, WinLab32 software makes method development effortless and ensures compliance even with today s most stringent regulatory standards. Multicomponent Spectral Fitting (MSF) Particularly effective when running complex matrices, this patented approach to interference correction allows the analytical signal to be extracted from the measured spectra without interferences for improved analytical accuracy, precision and detection limits. Time-resolved data acquisition Expanded to collect multi-element data up to 60 minutes. This Optima 8300 feature is used to facilitate speciation, laser ablation and hydride generation analyses. Continuous real-time graphics By acquiring and displaying data in real-time, WinLab32 software allows you to adjust the operating parameters of the instrument and RF generator during a run to optimize your method. For example, RF power and nebulizer flow can be changed while their impact is monitored. By displaying data in a continuous real-time graphics format, WinLab32 software makes it easier than ever to optimize instrument performance. In this example, signals can be seen to improve as the RF power is increased. 8

Enhance your productivity QC functions in manual mode To simplify operation and ensure quality data, WinLab32 software allows you to take full advantage of QC functions without the need for an autosampler. Adding methods during autosampler run Simply click on the Append Method button in the software interface and you can dynamically add to your autosampler run lists even after an analysis has started. Advanced SmartRinse feature SmartRinse customizes and adjusts rinse times based on element concentrations in each sample. With the Optima 8x00 series, you now have Advanced SmartRinse capability that allows for automatic rinse-time optimization to improve productivity while preventing sample-to-sample contamination. Multicomponent Spectral Fitting allows the analytical signal to be isolated from the measured spectra without interferences for superior accuracy, precision and detection limits. Get more out of your data QC charting Collect and maintain performance graphs over time by using this feature to quickly and easily prepare quality control charts from your data and store customized templates for future use. Results from QC samples, standards, blanks or any sample can be plotted, with limit ranges, means or expected values included on the chart. Results can even be formatted and exported for use with other applications. Transient signal handling expands sample-introduction capabilities to include speciation and hydride analysis. Reprocessing This useful tool allows you to optimize a measurement for a particular sample without having to re-run it. Potential adjustments include adding or changing background correction points, optimizing peak position, correcting data-entry errors and changing the calibration curve type. When reprocessing, the software never changes the original, raw data and clearly identifies the reprocessed data with a notation of what was done. Universal Data Acquisition (UDA) Running in UDA mode, WinLab32 gives you the flexibility to collect all the available spectral data for every sample regardless of the elements being determined. You can then retroactively determine the concentrations of elements not in the original method or at alternate wavelengths, avoiding re-runs and saving precious time and resources (Optima 8300). www.perkinelmer.com/optima8x00 9

To further enhance the instrument s functionality, PerkinElmer offers a full array of accessories and consumables designed, tested and proven to achieve the best performance, productivity and reliability, while minimizing overall operating costs. Autosamplers and Supplies Compatible with virtually all sample introduction systems, our productivity-enhancing S10, CETAC and ESI autosamplers are fully integrated with our WinLab32 for ICP software. A wide variety of high-quality autosampler tubes and supplies are also available. The S10 Autosampler can easily turn your Optima ICP-OES into a fully automated analytical workstation. Sample Preparation Multiwave 3000 microwave sample digestion system Precise control with high-power heating and high-pressure capability along with built-in cooling reduces cycle time, improving productivity PerkinElmer Sample Preparation Blocks (SPB) Acid-resistant, Teflon -coated blocks guarantee temperature uniformity for any digestion/heating method requiring a temperature below 180 C Flow Injection for Atomic Spectroscopy (FIAS) Systems A fully automated system that simplifies and speeds up analyses required for complex sample preparation, such as mercury and hydride-forming elements ICP Consumables and Supplies Nebulizers/Spray Chambers Revolutionary eneb electronic nebulizer, Scott/Cross Flow and Cyclonic/Meinhard options Injectors Full selection of alumina, quartz and sapphire injectors Flat Plate Torches PerkinElmer exclusive, one-piece, demountable quartz models designed for quick and easy replacement PerkinElmer Pure Standards Over 300 single and multi-element standards each with a Certificate of Analysis that documents the quality, stability and reliability For a complete listing of ICP consumables and supplies including information on other available torches, nebulizers, spray chambers and injectors please contact your sales or service representative or visit www.perkinelmer.com/icpoesconsumables. 10

PerkinElmer has been at the forefront of atomic spectroscopy technology for over 50 years. No matter what your field, application or sample type, we have the tools and expertise to help you achieve accurate results quickly, efficiently, effortlessly. With tens of thousands of installations worldwide, PerkinElmer systems are performing inorganic analyses every hour of every day. So turn to the most trusted name in the industry. And take advantage of a complete array of solutions engineered for unparalleled performance, accuracy and confidence. Atomic Absorption ICP-OES ICP-MS For more information on our full suite of atomic spectroscopy products and services including a wide array of mercury analyzers and sample preparation tools please visit www.perkinelmer.com/atomicspectroscopy. www.perkinelmer.com/optima8x00 11

PerkinElmer's OneSource Laboratory Services is the market leading laboratory asset management solution, pioneered more than a decade ago with more than 400,000 multi-vendor assets under its care. OneSource Laboratory Services goes beyond just maintenance and repair of instrumentation. OneSource incorporates laboratory asset management as part of our customers' business equation a partner with proven results in improving efficiencies, optimizing operations and providing cost certainty across the globe. OneSource, the ONE you can count on. PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com For a complete listing of our global offices, visit www.perkinelmer.com/contactus Copyright 2011, PerkinElmer, Inc. All rights reserved. PerkinElmer is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 009562B_01 Printed in USA