SHEAR STRENGTH OF CONCRETE COLUMNS WITH STEEL JACKETS

Similar documents
PERFORMANCE OF RC BRIDGE COLUMNS SUBJECTED TO LATERAL LOADING

Improvement of the seismic retrofit performance of damaged reinforcement concrete piers using a fiber steel composite plate

SHEAR STRENGTHENING OF RC BRIDGE PIERS BY STEEL JACKETING WITH EXPANSIVE CEMENT MORTAR AS ADHESIVE

Seismic Behaviour of RC Shear Walls

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE COLUMNS UNDER CONSTANT AND VARIABLE AXIAL LOADINGS

Ductile Detailing for Earthquake Resistant R C Structures. Dr. S. K. PRASAD Professor of Civil Engineering S.J. College of Engineering Mysore

EXPERIMENTAL STUDY ON THE PERFORMANCE OF THE RC FRAME INFILLED CAST-IN-PLACE NON- STRUCTURAL RC WALLS RETROFITTED BY USING CARBON FIBER SHEETS

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

Special Reinforced Concrete Structural Walls

SEISMIC STRENGTHENING AND REPAIR OF REINFORCED CONCRETE SHEAR WALLS

REINFORCED CONCRETE STRUCTURAL WALLS AS SOLUTION TO RETROFIT A R/C FRAME. Patricio Bonelli 1, Rubén Boroschek 2.

SEISMIC PERFORMANCE OF BRIDGE COLUMNS WITH DOUBLE INTERLOCKING SPIRALS

Response of columns and joints with spiral shear reinforcement

SHEAR PERFORMANCE OF RC MEMBERS STRENGTHENED WITH EXTERNALLY BONDED FRP WRAPS

Experimental Investigation of RC Beam Column Joint Strengthening

Efficiency of Injection Method in Repairing of Normal Strength and Reactive Powder Reinforced Concrete Beams

1337. Seismic response of beam-column joints rehabilitated with FRP sheets and buckling restrained braces

5.4 Analysis for Torsion

AN EXPERIMENTAL STUDY ON SCALE EFFECTS IN SHEAR FAILURE OF REINFORCED CONCRETE COLUMNS

Analytical prediction of tension force on stirrups in concrete beams longitudinally reinforced with CFRP bars

CYCLIC BEHAVIOR OF REINFORCED CONCRETE HAUNCHED BEAMS FAILING IN SHEAR

SEISMIC RETROFIT OF A TYPICAL REINFORCED CONCRETE BUILDING THROUGH FRP JACKETING OF EXTENDED RECTANGULAR COLUMNS

STEEL JACKETING FOR IMPROVEMENT OF COLUMN STRENGTH AND DUCTILITY

Experimental Study on behavior of Interior RC Beam Column Joints Subjected to Cyclic Loading P.Rajaram 1 A.Murugesan 2 and G.S.

SEISMIC PERFORMANCE AND RETROFIT OF BRIDGE FOOTINGS. David I. McLean 1

EXPERIMENTAL STUDY ON REINFORCED CONCRETE COLUMN STRENGTHENED WITH FERROCEMENT JACKET

A STUDY ON STRENGTHENING OF HOLLOW STEEL SECTION BY USING CFRP AND AFRP

INELASTIC SEISMIC PERFORMANCE OF RC TALL PIERS WITH HOLLOW SECTION

SEISMIC RETROFIT OF BEAM-COLUMN JOINTS WITH FRP SHEETS

1514. Structural behavior of concrete filled carbon fiber reinforced polymer sheet tube column

COMPARATIVE STUDY OF BEAMS BY USING DIFFERENT TYPES OF RETROFITING TECHNIQUES

AFRP retrofitting of RC structures in Japan

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: Vol.7, No.5, pp ,

Seismic Behavior of Concrete Columns Confined with Steel and Fiber-Reinforced Polymers

The Use of Bolted U-Link Swimmer Bars in the Reinforced Concrete Beams

PRIMARY AND SECONDARY REINFORCEMENTS IN CORBELS UNDER COMBINED ACTION OF VERTICAL AND HORIZONTAL LOADINGS

ISSN: Page 14

SEISMIC TEST OF CONCRETE BLOCK INFILLED REINFORCED CONCRETE FRAMES

SEISMIC BEHAVIOR OF FOUR-CIDH PILE SUPPORTED FOUNDATIONS

GATE SOLVED PAPER - CE

EXPERIMENTAL STUDY OF THE EFFECT OF REINFORCEMENT STABILITY ON THE CAPACITY OF REINFORCED CONCRETE COLUMNS

FLEXURAL RESPONSE OF FRC BEAMS WITH EXTERNAL GFRP LAMINATES

EXPERIMENTAL STUDY ON THE SEISMIC PERFORMANCE OF EXTERNALLY CONFINED REINFORCED CONCRETE COLUMNS

Chapter 7. Finite Elements Model and Results

Experimental study on behavior of Retrofitted with FRP wrapped RC Beam- Column Exterior Joints Subjected to cyclic loading

A Study on Hybrid FRP Wrapped Axially Loaded RC Capsule Column

EXPERIMENTAL INVESTIGATION OF THE JACK ARCH SLAB RETROFITTED BY CONCRETE LAYER

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 2, 2012

SEISMIC DAMAGE AND REPARABILITY EVALUATION OF RC COLUMNS IN TERMS OF CRACK VOLUME

Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems

beni-suef university journal of basic and applied sciences 5 (2016) Available online at ScienceDirect

TESTS ON AN INTERIOR REINFORCED CONCRETE BEAM-COLUMN JOINT. R. Park*, L. Gaerty**, and E.C. Stevenson***

Flexure and Serviceability Limit State

EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS

MPC-526 December 20, 2016

SSRG International Journal of Civil Engineering ( SSRG - IJCE ) Volume 4 Issue 12 December 2017

Javad VASEGHI AMIRI 1, Morteza HOSSEINALIBYGIE 2

Lap Splices in Tension Between Headed Reinforcing Bars And Hooked Reinforcing Bars of Reinforced Concrete Beam

FINITE ELEMENT ANALYSIS OF REINFORCED CONCRETE BRIDGE PIER COLUMNS SUBJECTED TO SEISMIS LOADING

RESEARCH ON SEISMIC RETROFIT OF EARTHQUAKE-DAMAGED AND SEISMIC-DEFICIENT STRUCTURES USING FIBRE-REINFORCED POLYMER (FRP) TECHNOLOGY

DETERMINATION OF ULTIMATE FLEXTURAL CAPACITY OF STRENGTHENED BEAMS WITH STEEL PLATES AND GFRP INTRODUCTION

Torsion. Design of Reinforced Concrete Structures I

Retrofitting methods

SHEAR STRENGTH CAPACITY OF PRESTRESSED CONCRETE BEAM- COLUMN JOINT FOCUSING ON TENDON ANCHORAGE LOCATION

AN IMPROVED COMPOSITE ANCHORING SYSTEM

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

Truss Analysis for Evaluating the Behavior of Reinforced Concrete Moment-Resisting Frames with Poorly Reinforcing Details

Design Example 2 Reinforced Concrete Wall with Coupling Beams

SEISMIC REHABILITATION OF REINFORCED CONCRETE BRIDGE COLUMNS IN MODERATE EARTHQUAKE REGIONS USING FRP COMPOSITES

CYCLIC RESPONSE OF RC HOLLOW BOX BRIDGE COLUMNS STRENGTHENED USING CFRP AND RC JACKETING

EXPERIMENTAL RESULTS

COLUMNS 1- Definition: The Egyptian code defines columns as : 2- Types of concrete columns

Analytical study of a 2-span reinforced concrete beam strengthened with fibre reinforced polymer

EFFECTS OF INTERACTION BETWEEN JOINT SHEAR AND BOND STRENGTH ON THE ELAST-PLASTIC BEHAVIOR OF R/C BEAM-COLUMN JOINTS

SEISMIC RETROFITTING OF REINFORCED CONCRETE BRIDGE FRAMES USING EXTERNALLY BONDED FRP SHEETS

Upgrading ductility of RC beam-column connection with high performance FRP laminates

Design for Shear for Prestressed Concrete Beam

IMPROVING SHEAR CAPACITY OF RC BEAMS USING EPOXY BONDED CONTINOUS STEEL PLATES

THE EFFECT OF AXIAL COMPRESSION RATIO ON SEISMIC BEHAVIOR OF INFILLED REINFORCED CONCRETE FRAMES WITH PROFILED STEEL SHEET BRACING

Nafadi, Khalaf Alla, Lucier, Rizkalla, Zia and Klein BEHAVIOR AND DESIGN OF DIRECTLY LOADED LEDGES OF SHORT SPAN L- SHAPED BEAMS

Seismic Analysis and Design of Flared Bridge Columns

AN EXPERIMENTAL STUDY ON ANCHORAGE OF TENSILE REINFORCEMENT OF WALL-COLUMNS AT THE TOP STORY OF RC WALL-FRAME STRUCTURES WITH FLAT-BEAMS

Fagà, Bianco, Bolognini, and Nascimbene 3rd fib International Congress

CYCLIC BEHAVIOR OF SLENDER R/C COLUMNS WITH INSUFFICIENT LAP SPLICE LENGTH

AXIAL LOAD FAILURE OF SHEAR CRITICAL COLUMNS SUBJECTED TO HIGH LEVELS OF AXIAL LOAD

Supplemental Plan Check List for Concrete Special Moment Resisting Frame

LOAD TESTS ON 2-SPAN REINFORCED CONCRETE BEAMS STRENGTHENED WITH FIBRE REINFORCED POLYMER

RESILIENT INFRASTRUCTURE June 1 4, 2016

INHERENT DUCTILITY OF REINFORCED CONCRETE SHEAR WALLS WITH NON-SEISMIC DETAILING

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering Indian Institute of Technology Madras

Analytical Investigation of Seismic Performance of Exterior RC Beam-Column Joints Rehabilitated with New Scheme

Column: Part 2 Courtesy of Dr. Latifee s IMI research group, Text books and others

BEHAVIOR OF FULL-SCALE SHEAR DEFICIENT CORNER RC BEAM-COLUMN CONNECTIONS RETROFITTED WITH CFRP SHEETS

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering Indian Institute of Technology Madras

Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain 1, Khaled Fawzy 2, and Mahmoud Nasr 3

Learning from Earthquakes to Improve Rehabilitation of Reinforced Concrete Buildings. James O. Jirsa The University of Texas at Austin

SHEAR BEHAVIOR OF RC DEEP BEAMS WITH SOLID CIRCULAR CROSS SECTION UNDER SIMPLY SUPPORTED CONDITION AND ANTI-SYMMETRIC MOMENT

Seismic Evaluation and Retrofit of Beam- Column Joints of Mid-America Bridges Part 2: Steel Sheet and Plate Retrofit

International Journal of Advance Research in Engineering, Science & Technology

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

Transcription:

SHEAR STRENGTH OF CONCRETE COLUMNS WITH STEEL JACKETS Oscar M GONZALEZ CUEVAS 1, José Juan GUERRERO CORREA 2, Bernardo GOMEZ GONZALEZ 3 And Félix Alberto FLORES DIAZ 4 SUMMARY Tests of reinforced concrete columns strengthened with steel jackets were carried out. The jackets consisted of longitudinal angles and transversal plates welded to the angles. This has been a usual method to retrofit buildings in Mexico City after the 1985 earthquakes. Several procedures were used to fix the jacket to the columns, including the use of epoxy resin, pressing the angles to the concrete, heating the plates and welding them to the angles while hot, and combinations of these procedures. Two sizes of angles and plates were used to build the jackets. The columns were subjected to axial and lateral, alternating loads, and were design to fail in shear. Jacketing improved both the strength and the ductility of the columns. The experimental strengths were at least equal to the theoretical strength calculated with the methods included in the Mexico City and ACI Building Codes, when small angles were used in the jackets. With large angles, it was necessary to stick the angles to the concrete with epoxy resin or to heat the plates before welding them, in order to reach the theoretical strength. However, some slipping of the jacket over the concrete was observed in some specimens, depending on the method used to fix the jacket. INTRODUCTION After the 1985 Mexico City earthquakes, many damaged buildings had to be repaired and many others, although not damaged, had to be strengthened due to more demanding Building Code specifications. A usual method of repairing or strengthening reinforced concrete columns was with steel jackets consisting of angles and plates (Gonzalez-Cuevas and Iglesias, 1995) The angles are put along the heigth of the columns, and the plates are put perpendicular or diagonally. This method is more economical than the use of a steel box with solid walls or collars, common in other countries. Several tests have been conducted in columns strengthened with solid steel jackets (Aboutaha et al, 1999; Priestley, et al, 1994). However, there is a lack of experimental evidence of the behavior of concrete columns with steel jackets consisting of angles and plates. Several construction methods are used in practice and an evaluation of these methods seems to be necessary. OBJECTIVES To study the behavior of reinforced concrete columns with steel jackets, to compare the experimental strength of these columns with the theoretical strength calculated with the Mexico City (1995) and the ACI (1995) Building Codes, to estimate the ductility of the columns and to compare different methods of putting the steel jackets over the columns. The tests reported in this paper were carried out in columns designed to fail in shear and were conducted in columns without any damage. Tests in previously damaged columns and in columns failing in compression and flexure are in progress. 1 2 3 4

EXPERIMENTAL PROGRAM Figure 1: Test specimen Figure 2: Test rig Figure 1 shows the specimen used in this series of tests. It is a rectangular section column, with b = 200 mm, h = 250 mm and l = 1500 mm. Longitudinal steel consisted of 4 No. 6 bars, and transversal steel consisted of the jacket plates, that was a variable in the study. The pilot specimens, without jacket, have only three No. 3 stirrups for construction purposes, one at each end and another one in the middle. Concrete compression strength was f c = 24.5 N/mm 2 and longitudinal steel yield point was f y = 412 N/mm 2. The jackets steel had a yield point f y = 248 N/mm 2 (A36 steel). The columns were fixed at one end and the loads were applied at the other end. This was a free end, so the specimen represents a part of a column between a joint and an inflection point. At the beginning of the tests, a 2

constant axial load of P = 1470 N was applied to the columns, then an horizontal, alternate load was applied. During the first load cycles, the horizontal load was a fraction of the calculated shear strength. After the yielding of the longitudinal steel, a lateral displacement was imposed to the column and this displacement was increased in each load cycle up to the column failure. Figure 2 shows the test rig and figure 3 shows a specimen being tested. Figure 3: Testing a specimen The variables in the study were the size of the angles and plates forming the jackets, and the construction method for fixing them to the concrete columns. Two sizes of angles were employed, both of equal legs. Small angles were 32 mm in width and 3.175 mm in thickness (1 ¼ X 1/8 ) and large angles were 64 mm in width and 6.35 mm in thickness (2 ½ x ¼ ). The cross section of the four small angles in a column is equivalent to the area of the longitudinal steel in a column corresponding to the minimum ratio specified in the Mexico City Building Code (0.04) and that of four large angles is equivalent to the maximum ratio in the Building Code (0.08). With small angles, plates 25.4 mm in width and 3.175 mm in thickness (1 x1/8 ) were used, and with large angles, plates 25.4 mm in width and 6.35 mm in thickness (1 X1/4 ). In both cases, plates were welded to the angles at 150 mm (6 ) center to center. With regard to the construction methods, the jacket was fixed to the column according to the following procedures: a) Pressing the angles to the concrete with a special devise controlling the pressing force, and welding the plates while the angles were pressed (Method A), b) The same procedure but additionally sticking the angles to the concrete with an epoxy resin (Method B), c) Sticking the angles to the concrete with epoxy, without pressing (Method C), d) Just putting the angles in the columns without pressing or sticking (Method D), e) Heating the plates to 90 C, and welding them to the plates while hot so that pressing is got by shortening of the plates as they cool (Method E), f) The same procedure but heating the plates to 70 C (Method F), and g) The same procedure but heating the plates to 50 C (Method G). Methods E, F and G represent the most common practice in Mexico. Heating of the plates is made usually with a welding blowpipe and a thermal chalk. However, in this research project, the plates were heated in an electric oven for better control of the temperature. Methods A, B, C, and D were used in combination with small angles and large angles. Methods E, F and G were used only with small angles, since it was evident in the first tests that behavior of the columns with small angles was good enough. Two specimens for each combination of variables were tested with methods A to D, and five 3

specimens with methods E to G. 34 specimens in total were tested, including three control specimens without jackets. Hereafter a notation is used consisting of the words small or large, referring to the angles of the jacket, followed by a capital letter, A to G referring to the method of fixing the jacket. The magnitude of pressing, applied directly with the device or through the cooling of the transversal plates, was calculated for not exceeding the allowable bearing stresses in the concrete. This was done with a finite element model. OBSERVED BEHAVIOR In each cycle, the lateral load and the lateral deflection at the free end of the columns were recorded, and the pattern of cracks was registered. Axial load remained constant at 1470 N, as mentioned above. Figure 4 shows a typical load deflection graph and figure 5, a typical pattern of cracks. Specimen Large B 20000.00 15000.00 Lateral load [kg] 10000.00 5000.00 0.00-60.00-40.00-20.00-5000.00 0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00-10000.00-15000.00-20000.00 Lateral deflection [mm] Figure 4: Typical load-deflection graph Figure 5: Pattern of cracks Failure occurred by shear in all the specimens, except Large B specimens that did not fail because the load capacity of the system was reached before failure and the test was interrupted. The patterns of cracks corresponded to shear failure in all the specimens, including those that did not fail. However, behaviors were rather ductile, as specimens resisted several cycles of load, and lateral deflections at failure were several times the deflection at yielding of the longitudinal steel. It was possible to determine a diagonal crack of 3 mm in width as that corresponding to severe damage in the specimens and identify the corresponding load to the so 4

called visual diagonal cracking load. The previously damaged specimens that are being tested in the continuation of this program are loaded until a 3 mm diagonal crack is detected and then they are jacketed and tested again. No damages were observed in the angles, in the transversal plates or in the welding of the plates to the angles. As it can be seen in table 1, the theoretical strength was greater than the experimental strength in most of the specimens. However, a slipping of the angles over the concrete was detected in some specimens that reached a good strength. Specimens corresponding to methods A, D, F, and G showed this behavior. It can be seen that epoxy prevents slipping of the angles and so it does a high temperature in heating the plates. The control specimens, without jackets and without lateral stirrups, had a brittle shear failure as expected, with diagonal cracks wider than 3 mm and small lateral deflections. THEORETICAL AND EXPERIMENTAL STRENGTHS The theoretical shear strength of the specimens was calculated with the following equations included in the Mexico City Building Code, similar to the ACI Building Code equations, although the axial load effect, second bracket of second member of equation 2, is taken in a different but equivalent way. V = V C + V S (1) C ' [ 0.16 f c bd] 1+ 0. ( Pu Ag ) [ ] = (2) V 007 V A f d s = S v y (3) where V = total shear strength V C = shear strength of concrete V S = shear strength of transversal steel P u = axial force A g = gross transversal area of the column A V = area of transversal stirrups s = distance between stirrups Equation 2 is in the SI system, with f c in N/mm 2, and A v in equation 3 is taken as the area of two transversal plates of the jacket, since this area is equivalent to the area of the stirrups in a beam or column. Reduction factors were not taken into account, nor reduced stresses specified in the Mexico City Building Code. The term V S was equal to cero for the control specimens. Table 1 shows the theoretical and experimental strengths of the specimens. The figures are the average of two specimens for methods A to D, five specimens for methods E to G, and three control specimens. Some tests were interrupted when a lateral load of 109.2 kn was reached because the load system could not provide a larger load. But the specimens had a severe damage and total collapse was near to occur. Table 1. Theoretical and Experimental Strengths Specimen Theoretical Strength (kn) Experimental Strength (kn) Small A 90.6 87.3 Small B 90.6 109.2 Small C 90.6 98.2 Small D 90.6 103.7 Large A 148.1 109.2 Large B 148.1 152.8 Large C 148.1 141.9 Large D 148.1 98.2 Small E 94.3 109.2 Small F 94.3 109.2 Small G 94.3 109.2 Control 58.3 60.8 5

ANALYSIS OF RESULTS a) Jacketing of columns with longitudinal angles and transversal plates improves the strength and the ductility of reinforced concrete columns failing in shear. The strength of jacketed members was 43 percent greater than control specimens as a minimum and 150 percent as a maximum. b) All the methods for fixing the jacket to the column were suitable for retrofitting concrete columns. Strength improvements were similar for the various methods, although method A, consisting in just pressing the angles against the concrete, was a little less efficient. However, slipping of the angles over the concrete was observed in some specimens. This behavior may be undesirable, since lateral deformations of buildings with columns strengthened with methods in which slipping may occur, can be excessive, and cumulative damage might develop. c) When the angles were fixed with epoxy resin to the columns, no slipping was observed even when no pressing of the angles against the column was applied. This behavior was observed with small and large angles. So, this suggests that it is unnecessary to apply both pressing and epoxy simultaneously (Method C). d) Pressing alone does not work better than just putting the angles over the column and welding the plates. It seems that early lateral deformation of the columns by Poisson effect develops pressing of the jacket against the column. e) The usual method of heating the transversal plates, and welding them to the angles while they are hot, worked very well. However, slipping of the angles were observed when the heating temperature was 50 C (Method G). Displacements up to 5 mm occurred. With temperatures of 70 C, displacements were very small, approximately 1 mm, and with 90 C no slipping was detected. f) The experimental shear strengths of jacketed columns with small angles were greater or almost equal than those calculated with the usual method presented in ACI and Mexico City Building Codes, equations 1 to 3. The difference in specimens Small A is negligible for practical purposes. However, in the specimens with large angles, the theoretical strength was not reached when the angles were not stuck to the concrete with epoxy or when the transversal plates were not heated before welding them to the angles. Slipping of the angles over the concrete was also greater in those specimens. It must be observed that in equations 1 to 3, the area of stirrups, A v, must be substituted by the area of the transversal plates. g) It seems unnecessary to use heavy jackets. Small angles with an area equivalent to the minimum longitudinal steel in columns, ρ = 0.04, provide enough strength improvement and it is easier to fix them to the column. CONCLUSIONS Jacketing of reinforced concrete columns with steel longitudinal angles and transversal plates is a suitable method for retrofitting columns. Strength and ductility are substantially improved whichever the method for fixing the jacket to the concrete. However, a recommendation is made to use epoxy resin to stick the angles to the concrete in order to avoid slipping of them. Slipping can be also avoided by heating the transversal plates before welding them to the angles to a minimum temperature of 70 C. When small angles are used in the jackets, whichever the method to put the jacket, the shear strength of the columns can be calculated with the equations of ACI or Mexico City Building Codes, using the area of transversal plates instead of the area of transversal stirrups. With large angles in the jackets, the equations can be used if they are stuck with epoxy resin or if the plates are heated before welding them to the angles. Otherwise, the equations may overestimate the strength of jacketed columns. REFERENCES Aboutaha, R. S.; Engelhardt, M. D.; Jirsa, J. O.; and Kreger, M. E. Rehabilitation of Shear Critical Concrete Columns by Use of Rectangular Steel Jackets. ACI Structural Journal, V. 96, No. 1, Jan.- Feb. 1999, pp. 68-87. American Concrete Institute (1995). Building Code Requirements for Reinforced Concrete (ACI 318-95). González Cuevas, O. and Iglesias, J. (1995). Lessons and Research in Repairing Concrete Structures Damaged by Earthquakes. Proceedings of the Conference Repair and Rehabilitation of the Infrastructure of the Americas H. A. Toutanji, Ed.. University of Puerto Rico, Mayaguez. Mexico City Government (1995). Reglamento de las Construcciones para el Distrito Federal-Normas Técnicas Complementarias para el Diseño y Construcción de Estructuras de Concreto. Priestley, M. J. N.; Seible, F.; Xiao, Y.; and Verma, R. A Steel Jacket Retrofitting of Reinforced Concrete Bridge Columns for Enhanced Shear Strength-Part 2: Tests Results and Comparison with Theory, ACI Structural Journal, V.85, No. 5, Sept.-Oct. 1994, pp. 537-551. 6