CIRRUS MAGNETIC FLOW METER CLA1-MF

Similar documents
CATALOG HHD ELECTROMAGNETIC FLOWMETER

PCL Series Electromagnetic Flowmeters

PCL Series Electromagnetic Flowmeters

PCL Series Electromagnetic Flowmeters

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application:

Electromagnetic Flange Type BTU METERS. eflow 800H SERIES. Size DN10 to DN1200 DESCRIPTION APPLICATION FEATURES

FLOMID FX Electromagnetic Flowmeter

Battery-Powered Magnetic Flow Meter

Battery-Powered Magnetic Flow Meter

ELECTROMAGNETİC FLOWMETERS

SpireMag Series MAG888

SpireMag Series MAG888

Electromagnetic Flowmeter

ISI Marked Class-A & Class-B Water Meters as per IS: 779 / 1994 Conforming to ISO 4064 Standard for Cold Water Meters

DRAWING SET A M I SN L F S E

SECTION Inline ULTRASONIC FLOW METERS

STANDARD TECHNICAL SPECIFICATION FOR ELECTROMAGNETIC FLOW METER with ACCESSORIES

Electromagnetic flowmeters. dg: NEW. Sensor MUT 2200 EL DS100-2-ENG 1/12

Portable Ultrasonic Flow Meters Ultrasonic Flow Meters Handheld Ultrasonic Flowmeter Wallmounted Ultrasonic Flow Meter Explosion Proof Ultrasonic

OPTIMASS 7400 Technical Datasheet

DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: m 3 /h. Accuracy: ± 0.3% of reading ± 0.

EMF-B split type EMF-A integrative type EMF-A integrative type Product applicability

VLM10 In-line Vortex Mass Flow Meter

POLYPROPYLENE SENSOR LIGHT WEIGHT SENSOR COMPLETELY IN POLYPROPYLENE

ALTOFLUX IFS 4000/4005

DeltaMass MT Series Mass Flow & Density Sensor

GUIDANCE NOTE. Performance of Electromagnetic Meters Designed for Use in Part-Filled Pipes.

DMH. Magnetic Inductive Flowmeter. for conductive fluids

OPTIMASS 7400 Technical Datasheet

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

F Series Flow Meter F300. User Manual

High-Performance Magnetic Flowmeter

LIQUID METER TYPE FMO

CALDON LEFM Ultrasonic Flowmeters for Gas Applications. Integrating experience, proven technology, and innovation

1. Product introduction. 2. Technical features. 3. Principle of Operation. 4. Technical Parameter. Electromagnetic flowmeter

DATA SHEET MS2500_EN-IT_DS006REV14

DATA SHEET MS2500_EN-IT_DS006REV17

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Flow measurement of Liquids and Gases

Coriolis Mass Flow Measurement System promass 63

SENSOR MUT1000EL. Electromagnetic flowmeter. The wafer electromagnetic flowmeter DS120-2-ENG

Using the PPM2 Portable Trace Moisture Transmitter

COIN. Flow Meters. Segmented Wedge. Your First Choice in Intelligent Flow Management...

TEK-B AR 3800E. Multivariable Pressure Transmitter. PRESSURE. Technology Solutions

PRODUCT CONFORMITY CERTIFICATE

Performance Evaluation of High speed Centrifugal pump at Varied Speed Conditions

Averaging PITOT Tube 5RD series

SCS-AMM15 : ADMIX SHOTCRETE MEASUREMENT SYSTEM

A M E M B E R O F T H E K E N D A L L G R O U P

PanaFlow MV82. Insertion Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

SECTION Coriolis Mass Flow Meters

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Turbine Meter. P e

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

FPI Mag Flow Meter. Next Generation Mag Meter: Solving WTP s Tight Installation Dilemma. McCrometer, Inc. (800)

Zirconia Oxygen Analyzer

FLUXUS F/G601 and F/G608

FISHERMETER. Swirl flowmeter FVST4. liquid gas steam

Datasheet Rev.1 Feb 2016 Orifice plate multi-holes

The World Market for Magnetic Flowmeters, 4 th Edition Proposal

Flow Meter Calibration

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

VERIS Accelabar. Superior Flow Measurement Accuracy

For Safe and Delicious Water

UTECO. Temperature Probes Overview. Temperature Probes for all Industries Level Switches Accessories, Cables & Transmitters

Because you can t manage what you don t measure usa.siemens.com/hvacr

Pressure Booster System. Hya-Eco VP. Type Series Booklet

TVA flowmeter. for saturated steam flow measurement

Averaging PITOT Tube 5RD series

Pitot Tubes and Industrial DP Transmitters (Optional Exercise)

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

Industrial Flowmeters

Flow Measurement SITRANS F M

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

Magnetic Flowmeter. Series. Bulletin 01E00A01-01EN.

Electrolyzer Solution. Instruments and Solution for Ion-Membrane Electrolyzer Plant Application. LF3BUSS01-00EN

RC400G FC400G RESIDUAL CHLORINE ANALYZER RC400G NON-REAGENT FREE CHLORINE ANALYZER FC400G RESIDUAL CHLORINE ANALYZER

Insertion Flow Meters. The only hot tap Full Profile Insertion Flow Meter.

VersaFlow Coriolis 200 Sensor for Mass Flow Specifications

Technical Specifications and General Guidelines for Mass Flow Meters at Petroleum Oil Installations. Note:

EN Size : Ends : Min Temperature : Max Temperature : Materials : Brass body

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)

Prosonic Flow B 200. For reliable flow measurement of biogas without limitations

Improved Flow Monitoring for Process Efficiency Improvements through New Technology Utilizing Non-Invasive Passive Arrays

Continuous Level Sensor CONDURIX 31.1

FLUIDISTOR GAS FLOWMETER GD 100 (EX)

DVH. Multivariable Vortex Flowmeter

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

JUMO flowtrans DP P. Pitot tube P01 to P04. Applications. Brief description. Special features. Customer benefits

The Unique Accelabar Flow Meter

Continuous Flow Monitoring. In-situ, low maintenance devices for continuous measurement of hot gas flow

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

Vortex Mass Flowmeter

TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

TOPAS PMG / PMH Hydraulic sensor Hot water

SECTION ULTRASONIC BIOGAS FLOW MEASURING SYSTEM

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

DIVA flowmeter. for saturated steam flow measurement

Transcription:

CLA1-MF

CLA1-MF MAGNETIC FLOW METER DESCRIPTION CLA1-MF Electromagnetic flow meters as they are called, operates on Faraday's law of electromagnetism to measure flow of conductive liquids. These flow meters efficiently measure liquid flow rate of liquids & converts it into 4-20mA output current signal or display it on LCD display unit. These flow meters incorporates advanced microprocessor based data processing electronics to ensure efficient and accurate operation, clear LCD unit to display flow rate & Totallized flow with EEprom memory to store data. Flow meter is sub classified into two main models : Integral Type - LCD : transmitter cum display electronic unit is mounted on top of the flow sensor. Remote Type - LCD : transmitter cum display electronic unit is separate wall mounted type & is connected to the flow tube sensor, with special cable to be ordered along with the flow meter. Flow meter consists of a hollow cylindrical shaped main flow sensing unit, its inner surface is lined with suitable insulation material called liner. Two sensing electrodes are placed diagonally opposite to each other. When excitation signals are given to these electrodes, a magnetic field with a magnetic flux (B), is generated in the direction vertical to the measuring pipe sensor. At this time if the flux with specific electro-conductivity flows through the measuring pipe, the line of magnetic force will induct electromotive force E. Electromotive force E is in directly proportional to magnetic flux B. With the product of inside diameter 'd' of flow meter pipe and average flow velocity V, electromotive force E (signal of the flow) is measured by electrodes and sent through cable to transmitter unit. Transmitter magnifies these flow signals by computing flow rate of flux and after converting displays it as liquid flow rate on LCD & a 4-20 macurrent output is also obtained. E = K B d V In the equation: E = signal voltage of inner electrodes (v) B = density of magnetic flux (T) d = inside diameter of measuring pipe (m) V = average flow velocity (m/s) In above equation, d is a constant. Since excitation current is constant B is also a constant. We can know from E = KBdV that flow rate of volume Q is directly proportional to signal voltage E, that is, signal voltage of flow rate induction E is in linear relation to flow rate of volume Q. So if only E is measured flow rate Q can be defined, which is the basic operating principle of magnetic flow meter. From E = KBdV we can see that the temperature of the measured flux medium, density, pressure, electroconductivity and the liquid-solid proportion of the liquid medium will not affect the measurement result. To moving condition if only it accords with the flow of axial symmetry (such as laminar flow) it will not affect the result of the measurement. Due to its operating principle, same magnetic flow meter can be used for different liquids having different physical parameters without any modification & with great efficiency. B V Magnetic flow meters are the efficient way for flow measurement of conductive liquids having conductivity greater than 5 µs/cm. Liquids should be enough conductive for better performance (conductivity of raw water lies between 500-1000 µs/cm). The flow meter s electronic unit is easy to configure by push buttons, have LCD display and efficient signal processing components. Various versions are available for use in different liquid media. Different Liners like Rubber & PTFE are available, for corrosive liquids like acidic effluent, acids, chemicals, pulps, juices, corrosive water etc. choice of optional measuring electrodes are available like SS316L, Hastelloy B, Hastelloy C, Titanium, Tantalum are available. Different models are available for high temperature operation and optional HART interface, RS485, RS232 communication, back light LCD display etc. For proper selection of right flow meter operating parameters like Flow rate, Pressure, Temperature, liquid conductivity, liquid corrosive nature etc. are to be foreseen and evaluated. Flow meter can thereby be selected with desired line size, flow rate, Liner material, Electrode material, temperature version & type of LCD display unit required etc. along with other general technical specifications. E Application: Water, Sewage, Chemicals, Pharmaceutical, Effluent, Industrial waste, solid mixed liquids, Acids, Paper pulp, Cane Juice, liquids with suspended solids, slurries etc..

VERSIONS INTEGRAL TYPE REMOTE TYPE Model with PTFE Liner MODEL Model with Rubber Liner Model with PTFE Liner CLA1-MF Versions Integral Remote Protection IP 65 Connection Flanged - CS IP 65 (IP 67, IP 68 optional) Sizes DN 25 ~ DN 2000 Liners Supply Output Process Temperature Media Electrodes Accuracy Flow tube Outputs (optional) Signal Cable (optional) Rubber / PTFE 220 V AC, 50 Hz / Optional 24 V DC 4-20 ma -20 to 180 Deg. C as per model selection Liquids with conductivity ratio more than 5 SS 316L / Hastelloy B,C / Ti / Ta 0.3% ~ 0.5% SS-304 HART / RS 232 / RS 485 µs/cm 10 ~ 20 meter integral (with remote version only)

INSTALLATION Flow meter to be installed vertically or horizontally on the pipe line, so that Flow meter shall always remain filled with flowing liquid during measurement. Vertical installation is recommended, so that flow meter shall always remain fully filled with liquid. For installation few of following methods are recommended for proper and efficient working of flow meters. 1. Flow meter to be installed with suitable straight pipe lengths for proper liquid flow, 5D at upstream (inlet) and 3D at down stream (outlet). D is the size of flow meter dia. All bends, valves etc. should be placed after or before these minimum clear straight pipe lengths. Arrangement should be made for easy removal and assembly of flow meter. Vertical installation 3 D 5 D 5 D 3 D 2. Flow meter to be installed at lower pipe or vertically at the upward pipe, where it should always operate fully filled. Never install it at highest place on pipe line, as flow meter may work empty or collection of air bubble may cause erratic reading. Also do not Install on down pipe as it may remain empty and give wrong working. Correct installation 3. Install Flow meter where pipe is slightly up rising. Highest place on pipe, cause wrong reading due to empty of flow meter and accumulation of air. Down pipe have zero flow Wrong installation. 4. On drainage discharge pipe, flow meter should be installed at lower point on pipe, so it should not work empty. 5. Install the control valve or shut off valve at downstream of meter. Always install flowmeter at the outlet of Pump and never to be installed before the suction of pump. Valve Pump Pump 3 D (wrong) Above are few indicative recommendations to install flow meter. Do refer to instruction manual before final installation. Remote version models are available with special flow signal cable. Flow rate is indicated in m3/hr and other parameters on LCD display unit of flow meters. Consider selection of proper electrodes, liner material, flow rate, pressure etc. for correct flow meter selection.

. Ø MODEL FLOW RANGE SIZE FLOW RATE (m 3 /hr) SIZE FLOW RATE (m 3 /hr) DN - 15 0.6 ~ 6.36 DN - 450 57.23 ~ 5722.65 DN - 20 0.11 ~ 11.30 DN - 500 70.65 ~ 7065.00 DN - 25 0.18 ~ 17.66 DN - 600 101.74 ~ 10173.60 DN - 32 0.29 ~ 28.94 DN - 700 138.47 ~13847.40 DN - 40 0.5 ~ 45.22 DN - 800 180.86 ~ 18086.4 DN - 50 0.71 ~70.65 DN - 900 228.91 ~ 22890.60 DN - 65 1.19 ~ 119.40 DN - 1000 282.60 ~ 22860.00 DN - 80 1.81 ~ 18.086 180.86 DN - 1200 406.94 ~ 40694.40 DN - 100 2.83 ~ 282.60 DN - 1400 553.90 ~ 55389.60 DN - 125 4.42 ~ 441.56 DN - 1600 723.46 ~ 72345.60 DN - 150 6.36 ~ 635.85 DN - 1800 915.62 ~ 91562.40 DN - 200 11.30 ~ 1130.40 DN - 2000 1130.40 ~ 113040.00 DN - 250 17.66 ~ 1766.25 DN - 2200 1367.78 ~ 136778.40 DN - 300 25.43 ~ 2543.40 DN - 2400 1627.78 ~ 162777.60 DN - 350 34.62 ~ 3461.85 DN - 2600 1910.38 ~ 191037.60 DN - 400 45.22 ~ 4521.60 For flow meter selection, flow range for each size flow meter to be checked along with other operational parameters including flow rate, temperature, max. operating pressure, liquid type, liquid conductivity etc. Ø 615 PCD Ø 565 + 0.1 565 +/- 0.1 (PCD) MODEL SELECTION E - CLA1 - MF - - - - - - - - Type I Integral R Remote Electrode S HB HC SS 316L Hest B Hest C TI Titanium TA Tantalum Size Liner R Rubber P PTFE R - DN 25...DN 2600 # Configuration may vary for each model. Consult us for model selection. N Temperature Range N Normal Pressure Range H High 600 Ø 615 Communication HART RS 232 RS 485 H R2 R4 Signal Cable (for remote version only) mtr. 10 M 15 M 20 M Contact us for other models & specifications not listed here. Due to constant product enhancement technical specification may vary. ENGINEERING & SERVICES PVT. LTD. A-79, 2nd Floor, Vishal Market, Tagore Garden Extn., New Delhi - 110027 Tel # 011-45613858, 20902218 Fax # 011-45613858 E-mail # cirrusinfo@gmail.com # cirrusinfo@cirrusindia.co.in Regional office.: 509, DDA Building -1, District Centre, Janakpuri, New Delhi - 110058 ISO9001:2008 certified WWW.INDIA.CO.IN