Brightfield and Fluorescence Imaging using 3D PrimeSurface Ultra-Low Attachment Microplates

Similar documents
Automated Imaging and Dual-Mask Analysis of γh2ax Foci to Determine DNA Damage on an Individual Cell Basis

Automated, Multi-Parameter, Kinetic Methods to Quantify Cell Death

Validation of High-Throughput Wound Healing Assay using 3D Cell Patterning and Automated, Kinetic Imaging

Use of Phase Contrast Imaging to Track Morphological Cellular Changes due to Apoptotic Activity

Long-Term Hepatotoxicity Studies using Cultured Human ipsc- Derived Hepatocytes

Automated, Kinetic Imaging of Cell Migration and Invasion Assays using Corning FluoroBlok Permeable Supports

Investigation of Cell Migration using a High Density Cell Exclusion Assay and Automated Microplate Imager

Performance of a Label-Free Image-Based 2D Scratch Wound Healing Assay to monitor Cell Migration and its Inhibition

Comparison of Oridonin Cytotoxicity in U-2 OS and HepG2 Cells

Introduction. Figure 1. Oris Cell Migration Assay Principle

Imaging of BacMam Transfected U-2 OS Cells

Cost-Effective Automated Hepatotoxicity Testing using in vitro 3D Bioprinting

Automated Imaging Assay for Characterizing Ca 2+ Flux with R-GECO Biosensor

Label-free, real-time live-cell assays for spheroids: IncuCyte bright-field analysis

Quantification of MMP Activity and Inhibition in a 3D Tumor Invasion Model

An Image-Based Method to Detect and Quantify T Cell Mediated Cytotoxicity of 2D and 3D Target Cell Models

Monitoring Cell Cycle Progression in Cancer Cells

Utility of Variable Bandwidth Monochromators for Quantification of Fluorescent Probes in Produced Effluent Water

Automated Digital Microscopy

An Automated, Cell-based Platform for the Rapid Detection of Novel Androgen Receptor Modulators

Live Cell Imaging of RNA Expression

Determination of Endogenous Cellular Kinase Activity Through the Use of an Automated, High Throughput AlphaScreen - Based Assay

Inhibition of Hypoxic Tumor Cells using a Three-Dimensional Spheroid Model

Corning Spheroid Microplates

High Contrast Brightfield

Assessment of HDAC1 Inhibition Using an Automated, Bioluminescent Histone Deacetylase I/II Assay

The Impact of a 3-Dimensional Human Liver Microtissue Model on Long-term Hepatotoxicity Studies

Validation of a Novel Tumoroid-Based Cell Culture Model to Perform 3D in vitro Cell Signaling Analyses

Validation and Comparison of Single-Step Flash and Dual-Spectral Luciferase Reporter Gene Assays using the Synergy Line of Microplate Readers

Automated Imaging and Analysis of a Novel Comet Assay to Enable High Throughput Genotoxicity Testing

Accurate and Automated cell confluence assessment in microplates

Automation of HTRF elf4e Kinase Assay Using a 3D Tumoroid- Based Cell Model

Optimizing Dual-Glo Luciferase Assays with the Synergy HT Multi-Detection Microplate Reader

NEW INSIGHTS. NEW DISCOVERIES. Real-time automated measurements of cell health, movement and function inside your incubator.

Performance of cell viability and cytotoxicity assays on the IN Cell Analyzer 3000

NEW INSIGHTS. NEW DISCOVERIES. Real-time automated measurements of cell health, movement and function inside your incubator.

Cell Health and Viability Assays Real-time automated measurements of cell health and viability inside your incubator

Peter Brescia, Applications Scientist and Peter Banks, Scientific Director, BioTek Instruments, Inc.

Normalization of Agilent Seahorse XF Data by In-situ Cell Counting Using a BioTek Cytation 5

Seevix s SVXgro: A Spidersilk Scaffold for Tissue Engineering

Corning Microplates for Microscopy and High Content Imaging. Improve results with microplates for high resolution cell imaging

Direct Cell Counting Assays for Immuno Therapy

Quantitation of ssdna using OliGreen Fluorescent Stain

Assay Name: Antibody-Dependent Drug Uptake Assay

MicroRNA Analysis Paired with Novel Cell Health Assays: A Complete Workflow

Add Live, Dead and Total Dyes. Overnight Variable 30 min. 10 min 5 min. 30 min

WHEN MULTIMODE MEETS IMAGING YOU GAIN A WHOLE NEW PERSPECTIVE. EnSight Multimode Plate Reader

Apoptosis And Anti-tumor Effect Induced By Mtor Inhibitor And Autophagy Inhibitor In Human Osteosarcoma Cells

Application Note. Introduction. Robbie Narang, Zhaoping Liu, Kim Luu IntelliCyt Corporation

Monitoring Saccharomyces cerevisiea Growth with Brightfield Microscopy in Real Time

Automated Monitoring of Protein Expression and Metastatic Cell Migration using 3D Bioprinted Colorectal Cancer Cells

A Cost-effective Workflow for High-Throughput Screening of G- Protein Coupled Receptors (GPCRs)

Optimization of a Multi-Mode Detection Model for Measuring Real-time Cellular Respiration and Mitochondrial Function using Fluorophoric Biosensors

ab Cell Viability Assay Kit Fluorometric Dual Green/Red

The BioFlux 200 System Using Well Plate Microfluidics for Live Cell Assays Product Overview and Tutorial

Limit of Detection. Theoretical Lowest Concentration

Your Power for Health. Magnetic cell culturing. The n3d approach

SensoLyte Homogeneous AFC Caspase-8 Assay Kit *Fluorimetric*

UV Fluorescence Polarization as a Means to Investigate Protein Conformational and Mass Change

Supporting information for Biomacromolecules article:

Cell Culture Flasks DATA SHEET

ATPlite Assay Performance in Human Primary Cells

Cellular Energy Flux in Real Time

Cell Viability Assay Kit Fluorometric Blue

AC Soluble Elastin PF Efficacy Data

AC Plant Keratin PF Efficacy Data

Cholesterol Uptake Cell-Based Assay Kit

An Automated DELFIA ADCC Assay Method using a CD16.NK-92 Cell Line

The CQ1 Confocal Quantitative Image Cytometer and its Application to Biological Measurement

Luminescent Viability Assays in Magnetically Bioprinted 3D Cultures


Kinetic measurement of cytotoxicity using CellTox Green Cytotoxicity Assay on the IncuCyte TM FLR or ZOOM

NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING

ab Generic Caspase Activity Assay Kit Fluorometric Green

Using the xcelligence RTCA SP Instrument to Perform Cytotoxicity Assays

SensoLyte Homogeneous AFC Caspase-8 Assay Kit *Fluorimetric*

Development of Novel Advanced Cell Culture Surfaces that Provide Better Cell Growth and Attachment for Cell-Based Assays

Synergy NEO HTS Multi-Mode Microplate Reader and Life Technologies Reagents

ab JC-10 Mitochondrial Membrane Potential Assay Kit Flow Cytometry

NF-κB/Jurkat/GFP Transcriptional Reporter Cell Line

SensoLyte AMC Calpain Activity Assay Kit *Fluorimetric*

Cell Viability Assay Kit Fluorometric Near InfraRed

Automated, High Throughput Methods for the Quantification of Endogenous Cellular Kinase Activity using HTRF Technology

APPLICATION SPECIFIC PROTOCOL CELL MIGRATION FOR ADHERENT CELLS

Assay Name: GFP Transfection Efficiency Measurement

colorimetric sandwich ELISA kit datasheet

GPCR induction followed by a fluorometric Ca 2+ assay in Thermo Scientific Varioskan LUX

SensoLyte Homogeneous AFC Caspase-3/7 Assay Kit

Seeding, culturing and assaying upcyte and vericyte cells in the Mimetix 3D scaffold

Morphology and ATP-based Cytotoxicity Profiling of Cancer Cell Lines using the EnSight Multimode Plate Reader with Well Imaging Technology

Quantification of Cell Migration and Invasion Using the IncuCyte Chemotaxis Assay

You ll never look at cells the same way again.

SensoLyte Homogeneous AFC Caspase-3/7 Assay Kit

ab Mitochondrial Viability Assay

High Throughput Quantitation of Cytokine Biomarkers using LANCE Ultra TR-FRET Assays

An automated image processing routine for segmentation of cell cytoplasms in high-resolution autofluorescence images

WST-8 Cell Proliferation Assay Kit. Item No

Cytotoxicity LDH Assay Kit-WST

LDH-Cytotoxicity Assay Kit II

Transcription:

A p p l i c a t i o n N o t e Brightfield and Fluorescence Imaging using 3D PrimeSurface Ultra-Low Attachment Microplates Brad Larson, BioTek Instruments, Inc., Winooski, VT USA Anju Dang, S-BIO, Hudson, NH USA Abstract Three-dimensional (3D) cell culture has become a well established in vitro experimental approach as it provides an improved in vivo-like environment. The use of clear U bottom ultra low attachment microplates that minimize cell adherance has become a standard for applications such as spheroid proliferation. Results shown here demonstrate the ability to generate quality results using both brightfield and fluorescence microscopy. Key Words: Spheroids 3D Spheroids Spheroid Microplates BioTek Instruments, Inc. P.O. Box 998, Highland Park, Winooski, Vermont 05404-0998 USA Phone: 888-451-5171 Outside the USA: 802-655-4740 Email: customercare@biotek.com www.biotek.com Copyright 2017 Introduction Culturing cells in three-dimensions (3D) has become a well established approach as it is more representative of the in vivo environment than traditional two-dimensional (2D) cultures. Allowing cells to interact with each other in a spheroid creates a micro-environment which mimics in vivo tissue and is a better model for examining the effect of drugs in cancer. Developing uniform spheroids becomes especially important as it forms the basis for robust and reliable assays. S-BIO PrimeSurface cultureware are ultra low attachment (ULA) dishes and plates that promote scaffold free, self assembly spheroid formation. The plates are pre-coated with a proprietary hydrophilic polymer that enables spontaneous spheroid formation of uniform size. PrimeSurface 96 and 384 ULA plates have good optical clarity making them highly suitable for brightfield and fluorescent imaging. Imaging technologies such as the BioTek Cytation 5 allows researchers to study not only spheroid proliferation through brightfield imaging, but also phenotypic events such as hypoxia, apoptosis, or necrosis induction through the use of fluorescent probes and fluorescence imaging. Incorporation of z-stacking and projection techniques in the Gen5 Microplate Reader and Imager Software create in-focus images of spheroidal cells, allowing accurate, robust, and repeatable determination of the effect of test molecules or conditions. In this app note, we present data generated with BioTek Cytation 5 using PrimeSurface ULA plates to develop simple robust spheroid assays for brightfield and fluorescence imaging. Materials and Methods Materials Cells and Media HT-1080 fibrosarcoma cells (Catalog No. CCL- 121) were purchased from ATCC (Manassas, VA). Advanced DMEM (Catalog No. 12491-015), fetal bovine serum, (Catalog No. 10437-036), and penicillin-streptomycin-glutamine (100X) (Catalog No. 10378-016) were purchased from ThermoFisher Scientific (Waltham, MA). Experimental Components The known topoisomerase I inhibitor, camptothecin (Catalog No. 208925) was purchased from EMD Millipore (Billerica, MA). CellTox Green Cytotoxicity Assay (Catalog No. G8731) was purchased from Promega Corporation (Madison, WI). PrimeSurface 96 U bottom, clear wall ULA plates (Catalog No. MS-9096UZ) and PrimeSurface 384 U bottom, clear wall ULA plates (Catalog No. MS- 9384UZ) were donated by S-BIO (Hudson, NH). Cytation 5 Cell Imaging Multi-Mode Reader Cytation 5 is a modular multi-mode microplate reader combined with an automated digital microscope. Filter- and monochromatorbased microplate reading are available, and the microscopy module provides up to 60x magnification in fluorescence, brightfield, color brightfield and phase contrast. The instrument can perform fluorescence imaging in up to four channels in a single step. With special emphasis on live-cell assays, Cytation 5 features shaking, temperature control to 65 ºC,

CO 2 /O 2 gas control and dual injectors for kinetic assays, and is controlled by integrated Gen5 Microplate Reader and Imager Software, which also automates image capture, processing and analysis. The instrument was used to image spheroids in the PrimeSurface plates using brightfield and fluorescence imaging. 3D Image Z-Stacking Parameters Focus Method Autofocus Number of Slices 9 Step Size 54.4 µm Images Below Focus Point 4 Table 2. Image Z-Stacking Parameters. Methods 3D Spheroid Formation HT-1080 cells were added to wells of the 96- and 384-well PrimeSurface U bottom microplates at concentrations of 10000, 5000, 2000, 1000, 500, 250, 100, and 50 cells per well in volumes of 100 or 50 µl for the 96- or 384-well plates, respectively. The microplates were incubated at 37 C/5% CO 2 for 48 hours to allow the cells to aggregate into spheroids. Camptothecin Treatment and Dead Cell Staining Upon completion of the aggregation process, a subset of spheroids seeded at 1000 cells/well were treated with either 10,000, 500, 10, or 0 nm camptothecin by manually removing media and replacing with an equal volume of fresh media containing the drug. The plates were then incubated at 37 ºC/5% CO 2 for an additional 24 hours to induce necrosis within the treated spheroidal cells. The following day media was again removed from the wells and replaced with media containing 1x CellTox Green necrotic cell stain. The plates were incubated at 37 ºC/5% CO 2 for 5 hours to allow fluorescent probe penetration into the cells. A final media exchange was performed to remove excess stain. Automated Imaging Procedure Spheroid imaging was carried out to assess the ability to generate quality images and accurate cellular analysis. Brightfield and fluorescent images were captured using the imaging channels listed in Table 1. Brightfield GFP Imaging Target Table 1. Cell Imaged per Imaging. Total Spheroids Spheroidal Dead Cell Nuclei As the cells within the spheroids exist within a range of z-planes, a z-stacking imaging procedure was setup within Gen5. Following auto focusing, multiple images were captured above and below the focal plane to ensure cells were imaged at the proper z-height (Table 2). 3D Image Processing Following capture, a z-projection of the images in the z-stack was carried out using the focus stacking algorithm to create a final image containing only the most in-focus information (Table 3). 3D Image Stitching Parameters Method Focus Stacking Brightfield Size of Max. Filter 11 pixels Top Slice 9 Bottom Slice 1 Table 3. 3D Z-Projection Criteria. Cellular Analysis of 3D Projected Images Cellular analysis was carried out on the projected images of untreated variable sized spheroids using the criteria in Table 4. Spheroid Cellular Analysis Criteria ZProj[Brightfield] Threshold 10000 Background Light Split Touching Objects Fill Holes in Masks Min. Object Size 75 µm Max. Object Size 1000 µm Include Primary Edge Objects Analyze Entire Image Advanced Detection Options Rolling Ball Diameter Auto Image Smoothing Strength 0 Evaluate Background On 5% of Lowest Pixels Analysis Metric Metric of Interest Table 4. Spheroid Identification Criteria. Spheroid Volume An additional cellular analysis step was performed on the treated spheroids to determine the extent of necrotic activity induced by the camptothecin treatment (Table 5). 2

Spheroid Necrosis Induction Analysis Criteria E. Primary Mask Criteria ZProj[Brightfield] Threshold 25000 Background Split Touching Objects Fill Holes in Masks Light Min. Object Size 200 µm Max. Object Size 1000 µm Include Primary Edge Objects Analyze Entire Image Advanced Detection Options Rolling Ball Diameter 600 Image Smoothing Strength 0 Evaluate Background On Measure Within a Secondary Mask Secondary Mask Criteria 5% of Lowest Pixels ZProj[GFP] Expand Primary Mask 1 µm Threshold 30000 Smooth 0 Method Fill Holes in Mask Metric of Interest Metric of Interest Custom Metric of Interest Analysis Metric Threshold In Mask Object Area Area_2[ZProj[GFP]] % Necrotic Cell Area Table 5. Spheroid Necrosis Induction Analysis Criteria. Results and Discussion Brightfield Imaging of Formed Spheroids Visual analysis of the z-projected images reveals that HT-1080 cells are able to form tight spheroids within the 96-well U bottom plates. It is also evident that the z-stacking and projection method used by the Gen5 Microplate Reader and Imager Software creates accurate, in focus spheroidal images regardless of size (Figure 1). C. D. Figure 1. 96-well U bottom brightfield spheroidal imaging. 4x z-projected brightfield images of spheroids formed from (A) 10000; (B) 5000; (C) 2000; (D) 1000; (E) 500; (F) 250; (G) 100; or (H) 50 cells per well. A final observation apparent from the images is the flat, or even background signal generated from the bottom of the microplate wells during brightfield imaging. Using the Line Profile tool available in Gen5, a line can be drawn from one side of an image to the other, bisecting the spheroid (Figure 2A). This creates a brightfield intensity graph representative of the CCD pixel intensities along the line. It is evident that there is a large decrease in pixel intensity as the line passes through the spheroid and that the other pixels representative of background are relatively bright and uniform in intensity (Figure 2B). F. G. H. 3

Figure 2. Image background and target object brightfield signal. (A) 4x brightfield image of 100 cell spheroid plus drawn View Line Profile tool line. (B) Graph of brightfield signal from 1915 µm drawn line. Figure 3 demonstrates the accurate placement of primary masks necessary for area and diameter measurements using parameters in Table 4. Using the two metrics, a volume calculation can be made. C. Figure 3. Cellular analysis of test spheroids. Gen5 automatically drawn object masks around spheroids formed from (A) 10000; (B) 1000; and (C) 50 cells. Spheroid analysis was performed in both 96- and 384-well PrimeSurface plates. Figure 4 illustrates the precision and linearity of spheroid volume as a function of cell seeding density. Figure 4. Plot and linear regression of Gen5 96- and 384-well calculated spheroid volumes. 4

Fluorescent Imaging of Necrotic Cell Induction within Spheroids Imaging was also carried out on treated and stained 1000 cell spheroids to determine the level of necrotic cell induction caused by camptothecin. Brightfield images were captured, in addition to fluorescent images in the GFP channel to specifically view necrotic cells stained by the CellTox Green probe. An overlay was then created to visualize cellular necrosis within each spheroid (Figure 5A). The second step was to quantify the area covered solely by necrotic cells within each test spheroid. A concern, though, with using clear walled microplates to perform fluorescence imaging and then ascertain accurate results is the autofluorescence from the clear walls, contributing to high background within the image. Use of the Gen5 Line Profile tool, however, confirms that this phenomenon was not witnessed when using the clear U bottom microplates (Figure 6A). A consistently low background signal was seen from areas of the image not containing necrotic cells, allowing for an easily distinguishable change in signal from affected cells (Figure 6B). Figure 5 Imaging of camptothecin induced spheroidal cell necrosis. 4x z-projected, overlaid brightfield and GFP image of spheroid showing necrotic cell induction caused by 24 hour 10,000 nm camptothecin. Figure 5 Primary cellular analysis to determine necrotic cell induction. Gen5 automatically drawn primary object masks around 1000 cells spheroid treated with 10,000 nm camptothecin. Figure 6. Image background and target object fluorescent signal. (A) 4x GFP image of 1000 cell spheroid treated with 10,000 nm camptothecin, plus drawn View Line Profile tool line. (B) Graph of GFP signal from 1037 µm drawn line. To quantify the level of induced necrosis, cellular analysis was once again performed on the spheroidal images. To determine the area covered by both live and dead cells within the captured images, object masks were placed around the spheroids (Figure 5B) using the brightfield channel and primary mask criteria described in Table 5. By taking advantage of the optical qualities of the U bottom plates, accurate object masks were able to be placed around affected cells, regardless of whether high or low levels of necrotic activity were generated by the camptothecin concentrations (Figure 7). 5

The images in Figure 7 of object mask placement based upon GFP signal, in addition to the graph of camptothecin induced spheroidal cell necrosis, confirms that accurate imaging and analysis can be carried out when using fluorescent channels and the U bottom microplates. Conclusions C. S-BIO PrimeSurface U bottom 96- and 384-well microplates can be used to create appropriately sized, repeatable single spheroids within each test well. The Cytation 5 and Gen5 software also provide the ability to capture high quality images on multiple z-planes, suitable for spheroid imaging. The combination of the optical quality of the microplates and Gen5 software then allow accurate quantification of proliferation or induced phenotypic events within the spheroids using either brightfield or fluorescence microscopy. Figure 7. Necrotic cell analysis of treated spheroids. Gen5 automatically drawn object masks around necrotic cells within spheroids treated with (A) 10; (B) 500; or (C) 10000 nm camptothecin. When the necrotic cell area was divided by the total cell area, a normalized affected cell percent coverage area was created, which accounted for variances in area between the treated 1000 cell spheroids. The values were then plotted in terms of the concentration of camptothecin used for treatment (Figure 8). Figure 8. Plot of percent spheroid area covered by affected necrotic cells following camptothecin treatment. 6 AN121917_22, Rev. 12/19/17