Mandatory Wood Frame Soft-story Retrofit Program STRUCTURAL DESIGN GUIDELINES

Similar documents
SEISMIC DESIGN GUIDELINES

ALTERNATE DESIGN METHODOLOGY FOR UNREINFORCED MASONRY BUILDINGS

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

ORDINANCE NO. 16- The City Council of the City of West Hollywood does hereby ordain as follows:

City of Berkeley Framework Guidelines for Soft, Weak or Open Front Building Retrofit Design

STRUCTURAL OBSERVATION

Question 8 of 55. y 24' 45 kips. 30 kips. 39 kips. 15 kips x 14' 26 kips 14' 13 kips 14' 20' Practice Exam II 77

STRUCTURAL DESIGN REQUIREMENTS (SEISMIC PROVISIONS) FOR EXISTING BUILDING CONVERTED TO JOINT LIVING AND WORK QUARTERS

Fallen buildings have collapsed, caught fire or needed extensive repairs to restore occupancy.

Building Division Informational Handout

Mandatory Wood Frame Soft-story Retrofit Program PERMITTING AND INSPECTION PROCESS GUIDELINES

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

Special Civil Engineer Examination Seismic Principles Test Plan

0306 SEISMIC LOADS GENERAL

Plan Check No. Checked by: An Appointment Is Required for Verification

Recent Advances in Seismic and Wind Design of Wood Structures &Historic Preservation Examples

SEISMIC STRENGTHENING PROVISIONS FOR UNREINFORCED MASONRY BEARING WALL BUILDINGS

4.6 Procedures for Connections

Supplemental Structural Correction Sheet Steel Moment Frame Design (2017 LABC)

4.2 Tier 2 Analysis General Analysis Procedures for LSP & LDP

Los Angeles Soft, Weak, or Open-Front Wall Line Ordinance Retrofit Example

Diaphragms 2. Design Process. Design Process. Diaphragms are the roofs and floors of the upper stories

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

Supplemental Plan Check List for Unreinforced Masonry (URM) Retrofit

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

Significant Changes to AWC s Special Design Provisions for Wind and Seismic

Structural Design Engineers 120 Montgomery Street, Suite 1410 San Francisco, California / Fax 415/

Supplemental Plan Check Corrections Sheet for Structural Design - General (2011 LABC)

Plan Check / PCIS Application #: Job Address P.C. Engineer ( Phone

Division IV EARTHQUAKE DESIGN

3.5 Tier 1 Analysis Overview Seismic Shear Forces

FEMA P-593 STEP-BY STEP PRESCRIPTIVE RETROFIT FOR CRIPPLE WALL BRACING & ANCHORAGE TO FOUNDATION

STRUCTURAL EVALUATION OF DOVER ELEMENTARY SCHOOL WEST CONTRA COSTA UNIFIED SCHOOL DISTRICT (WCCUSD)

Seismic Design of Precast Concrete Structures

ISSUE A Code Change # 2 Class 3 and Class 4 Buildings

Lateral Design of Mid- Rise Wood Structures

2015 Special Design Provisions for Wind and Seismic Philip Line, P.E., John Buddy Showalter, P.E., Michelle Kam-Biron, P.E., S.E., Jason Smart, P.E.

Chapter 2 EARTHQUAKE-RESISTANCE REQUIREMENTS

Stone and Masonry Veneer

Everything Need to Know About Soft Story

CE 549 Building Design Project Spring Semester 2013

CALIFORNIA BUILDING AND SAFETY COMMISSIONERS. nmi 'DEI ERIC GARCETTI MAYOR PROPOSED SUBSTANTIAL STRUCTURAL DAMAGE ORDINANCE- COUNCIL FILE

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

10. Simplified Rehabilitation

WIND & SEISMIC 2008 EDITION ASD/LRFD WITH COMMENTARY. American Forest & Paper Association. American Wood Council ANSI/AF&PA SDPWS-2008

WIND & SEISMIC 2008 EDITION ASD/LRFD WITH COMMENTARY. American Forest & Paper Association. American Wood Council ANSI/AF&PA SDPWS-2008

SDPWS. Special Design Provisions for Wind & Seismic 2015 EDITION

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

RESIDENTIAL SEISMIC RETROFITS

ORDINANCE NO

90% Design Submittal Structural Calculations Parking Garage CDRL

Learning Objectives. Topics. Moment Frames: Design and Detailing per AISC 341 and 358. Topics. Lateral Analysis/Choosing your Code

Masonry and Cold-Formed Steel Requirements

Home Not Anchored to Foundation

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

Table 1. Detailed Comparison of Structural Provisions of 2000 IBC to 1997 NEHRP (continued)

Chapter 2 QUALITY ASSURANCE

Tables with Allowable ASD Seismic Values For Design at R = 6.5. Special Moment Frame MF1-12

fifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance

Alexis Pacella Structural Option Dr. Schneider Lexington II, Washington D.C. Technical Report #3 November 21,

MOUNTAIN STATE BLUE CROSS BLUE SHIELD HEADQUARTERS

Project Seismic Vulnerability Assessment For SFCC District Building 33 Gough Street San Francisco, California 94103

North Shore at Canton Baltimore, MD Beau Menard Technical Report 1

BUILDING INTEGRITY SUMMARY REPORT

Lateral System Analysis and Confirmation Design

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

Supplemental Concrete Tilt Up Retrofit Plan Check Correction Sheet (2014 LABC)

A. Are Plan Reviews Important? B. Statement of Special Inspections C. Deferred Submittals D. DFCM Requirements

CE 549 Building Design Project Spring Semester 2010

Structural Training - Part 1:

STRUCTURAL EVALUATION OF WASHINGTON ELEMENTARY SCHOOL WEST CONTRA COSTA UNIFIED SCHOOL DISTRICT (WCCUSD)

CASE STUDY OF A 40 STORY BRBF BUILDING LOCATED IN LOS ANEGELES

Lateral load basics Code acceptance of Standard. Standard Overview 2008 Wind & Seismic Standard. Wind. Wind Load Path. IBC Section 1604.

APPENDIX A1 WIND AND SEISMIC BRACING GUIDELINE FOR ONE AND TWO FAMILY DWELLINGS AND TOWNHOUSES

SEAU 5 th Annual Education Conference 1. ASCE Concrete Provisions. Concrete Provisions. Concrete Strengths. Robert Pekelnicky, PE, SE

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

STORAGE RACKS PLAN REVIEW LIST (2011 LABC)

Burbank Municipal Code A300: ADOPTION OF CODE: Page 8 of 13

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

City of Bemidji Building Office City Hall 317 4th Street NW Bemidji, Minnesota Phone Fax emi mn s

PEER Tall Building Seismic Design Guidelines

6-Story Wood Frame Committee

SEATTLE CENTRAL COLLEGE BROADWAY PERFORMANCE HALL SEATTLE, WASHINGTON STRUCTURAL EVALUATION FOR PREPARED BY PCS STRUCTURAL SOLUTIONS

RESPONSIBILITIES IN THE DESIGN PROCESS INVOLVING METAL PLATE CONNECTED WOOD TRUSSES

Principles of STRUCTURAL DESIGN. Wood, Steel, and Concrete SECOND EDITION RAM S. GUPTA. CRC Press. Taylor& Francis Group

WALL CONSTRUCTION CHAPTER 6

111 MORGAN ST. Ryan Friis

The designer shall also submit additional information required by the University as described and underlined below.

OVERALL STRUCTURAL SYSTEM

ADDENDA #9- RFP Sylvania CC building Re-Roof Progressive Design Build for Sylvania Campus CC Building Re-Roof Services

THE PLAZA AT PPL CENTER ALLENTOWN, PA

ASCE Structural Evaluation Report

[TECHNICAL REPORT 3] Lateral System Analysis

Rich Denio, Supervising Structural Engineer Ron LaPlante, Supervising Structural Engineer

ORDINANCE NO

Transcription:

INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LAMC Division 93 Effective: 11/22/15 DOCUMENT NO.: P/BC 2014-137 Revised: 06/07/16 Previously Issued As: N/A Mandatory Wood Frame Soft-story Retrofit Program STRUCTURAL DESIGN GUIDELINES The purpose of this information bulletin is to provide structural design guidelines to strengthen deficiencies in wood frame soft-story buildings per Division 93, Los Angeles Municipal Code (Ordinance 183983 and Ordinance 184081). This new revision of the code mandates a standard for earthquake hazard reduction in existing wood-frame buildings with soft, weak, or open-front walls. I. Definitions OPEN-FRONT WALL LINE is an exterior wall line, without vertical elements of the lateral force-resisting system, which requires tributary seismic forces to be resisted by diaphragm rotation or excessive cantilever beyond parallel lines of shear wall. Diaphragms that cantilevered more than 25% of the distance between lines of lateral force resisting elements from which the diaphragm cantilevers and exterior balconies of 6 feet or more in width shall be considered excessive. RETROFIT is an improvement of the lateral force system by alteration of existing structural elements or addition of new structural elements. SOFT WALL LINE is a wall line, the lateral stiffness of which is less than what is required by story drift limitations or deformation compatibility requirements of this division. In lieu of the engineering analysis required by this division to determine whether a wall line s lateral stiffness is less than the aforementioned story drift limitations or deformation compatibility requirements, a soft wall line may be defined as a wall line in a story where the wall stiffness is less than 70% of the stiffness of the exterior wall above for the direction under consideration. STORY STRENGTH is the total strength of all seismic-resisting elements sharing the same story shear in the direction under consideration. WALL LINE is any length of a wall along a principal axis of the building used to provide resistance WEAK WALL LINE is a wall line at the ground floor where the wall strength is less than 80% of the strength of the wall above in the direction under consideration. Page 1 of 5

II. Design Methods A. Analysis and Design Requirements. The retrofit shall meet the strength and stiffness in conformance to the 2014 LABC except as modified under section 9309. The lateral-load-path analysis shall include the resisting elements and connections from the wood diaphragm immediately above any soft, weak, or open wall lines and down to the foundation. Stories above the weak wall line shall be considered in the analysis but need not be modified. 1. Design base shear. a) The design base shear shall be 75 percent of the value specified ASCE 7-10 section 12.8.1. b) The value of Response Modification Factor, R, used in any direction shall not exceed the value at any story above, in the same direction. (1) R need not be less than 3.5, provided the structural systems are not cantilevered column systems and the strengthened structure will not have vertical irregularities of either type 1a, 1b, 5a or 5b listed in ASCE 7-10, Vertical Structural Irregularities Table 12.3-2. (2) If using R greater than 3.5, the existing lateral system shall be verified to comply with specifications of other lateral systems listed in ACSE 7-10, table 12.2-1. (3) The deflection amplification factor C d value shall be 3 and overstrength factor, Ω 0, shall be 3 which is consistent with the R value of 3.5 as specified in the seismic provisions of ASCE 7-10 for the lateral resisting system. Cantilever Column systems shall still use the values corresponding to the system. 2. Lateral Vertical Systems. a) Strengthening systems with concrete walls or masonry walls, or steel braced frames shall not be permitted. The use of and/or strengthening of existing masonry or concrete walls is permitted provided the whole story is analyzed. b) Steel Moment Frame: (1) Steel OMF is not permitted in SDC D, E and F.* (2) Steel IMF is not permitted in SDC E and F.* *For exceptions: see Steel Moment Frame Design Information Bulletin, P/BC 2008-098 or ASCE 7-10 Table 12.2-1 Page 2 of 5

3. Horizontal Structural Irregularities in Buildings. Structures with 3 or more stories having horizontal structural irregularities shall be altered to meet the additional requirements of ASCE 7-10 per table 12.3-1 only if they are located in the area of Retrofit. 4. Vertical distribution of seismic forces over the height of the structure shall be based on ASCE 7-10 section 12.8.3. 5. Additional Anchorage Requirements for Buildings on Hillsides. Where a building or a portion thereof is constructed on or into a slope steeper than 33% slope, the lateral-force-resisting system, at and below the base level diaphragm, shall also be analyzed for the effects of concentrated lateral loads caused at the building base from the hillside conditions and must comply with the provisions of Division 94. 6. Story Drift Limitations a) The calculated story drift shall not exceed the allowable deformation compatible with all vertical load-resisting elements and 0.025 times the story height. b) In lieu of verifying the stiffness of the floor with the new strengthening system(s) is greater than 70% of the stiffness of the floor above, limit the drift to 2% of the story height. 7. P-delta effects. The stress analysis of cantilevered columns shall use a buckling factor of safety of 2.1 for the direction normal to the axis of the beam. 8. Consider 10 psf for partition loads per ASCE 7-10 chapter 12. 9. Account for weight of exterior walls in stories above the soft wall line. 10. Horizontal Diaphragms. a) Diaphragms that cantilever more than 25% of the distance between lines of lateral-load-bearing elements from which the diaphragm cantilevers shall be designed for shear transfer. b) Limit diaphragm ratio to 3:1. 11. Ties and continuity. Design all the elements in the lateral load path to transfer seismic loads from diaphragm to the foundation. 12. Collector elements. a) Design collectors and drag struts. b) Size and spacing of all existing elements in the shear path used in shear transfer calculations shall be clearly identified in the plans as To Be Verified in Field during construction. Page 3 of 5

13. Deformation Compatibility. All structural framing elements and their connections not required to be part of the lateral system, shall be designed and detailed to be adequate to maintain support of design dead and live loads when subject to expected deformation of seismic loads. B. Alternate Design Methods: Pursuant to Section 104.2.6, the department may approve alternate design methods that improve the entire first story seismic performance and are at least equivalent to those prescribed in Division 93. The retrofit design using alternate methods shall achieve the life safety objectives established by Division 93. The following are approved alternate design methods. 1. Appendix Chapter A4, 2012 International Existing Building Code. The entire weak first story must be analyze and designed. 2. ASCE 41-13, Seismic Evaluation and Retrofit of Existing Buildings, a) Design to meet the Rehabilitation Objective (Section 1.4) (Life Safety Performance Level: S 3) for the BSE 1 earthquake hazard level b) Retrofit strength need not exceed 1.3 times the strength of story above. 3. FEMA P-807, Seismic Evaluation and Retrofit of Multi-Unit Wood- Frame Buildings with Weak First Stories. a) The entire weak first story must be analyze and designed. b) The spectral demand shall be 0.5S MS, calculated in accordance with ASCE 7-10 section 11.4 except that for sites in site class E, the value of F a shall be taken as 1.3 c) Acceptable performance level shall be based on drifts corresponding to Onset of Strength Loss in the seismic force-resisting wood-frame elements. d) The maximum limit probability of exceedance (POE) for evaluation or retrofit design shall be 20%. e) Limit diaphragm ratio to 2:1. III. Existing Materials All existing components and materials shall be in sound conditions and constructed in conformance to the 2014 LABC before they can be used to resist lateral loads. A. Existing shear walls that require analysis, shall be permitted to use the values as follows: Page 4 of 5

Wood stud walls with lath and plaster 100 lbs. per foot B. Existing Horizontal wood diaphragms that require analysis, shall be permitted to use the values as follows: 1. HORIZONTAL DIAPHRAGMS a. Roofs with straight sheathing and roofing applied 100 lbs. per foot directly to the sheathing. b. Roofs with diagonal sheathing and roofing applied 400 lbs. per foot directly to the sheathing. c. Floors with straight tongue-and-groove sheathing. 150 lbs. per foot d. Floors with straight sheathing and finished wood flooring e. Floors with diagonal sheathing and finished wood flooring. f. Floors and roofs with straight sheathing and plaster applied to the joist or values for items 1 (a) and 1(c) rafters 300 lbs. per foot 450 lbs. per foot Add 50 lbs. per foot to the allowable values for items 1(a) and 1(c) C. For all other existing structural members, allowable design values are as follows. 1. Plain or reinforced concrete footings f' c = 1500 psi unless otherwise shown by tests 2. Douglas fir wood Allowable stress same as No. 1 D.F. 3. Reinforcing steel f s = 0.4 F y, maximum 18 ksi 4. Structural steel f b = 0.6 F y, maximum 20 ksi 5. Anchor Bolts Current code values IV. Declaration (Engineer s or architect s statement) The responsible engineer or architect shall provide the following statement on the approved plans: I am responsible for designing this building s seismic strengthening in compliance with the minimum regulations of the Mandatory Earthquake Hazard Reduction In Existing Wood-Frame Buildings with Soft, Weak, or Open-Front Walls (LAMC Division 93). Page 5 of 5