A SAGE METERING White Paper SAGE METERING 8 Harris Court, Building D1, Monterey, CA Telephone: (831)

Similar documents
Greenhouse Gas Emissions Monitoring Using Thermal Mass Flow Meters

Thermal Mass Flow Meters Help Reduce Energy Costs and Enhance Emissions Monitoring Systems

s the costs of fuels and consumables to rise, the ability to accurately measure the amount used in a process becomes significant

February 5, 2013 Roy Ratcliffe, President RM Controls, Inc.

VLM10 In-line Vortex Mass Flow Meter

Because you can t manage what you don t measure usa.siemens.com/hvacr

F-2200 Series Steam Meter

Accutube Averaging Pitot Tubes

ABB Measurement & Analytics Flowmeter technologies

Selecting the correct device for measurement control

Utility Flow Metering for Steam and Heated/Chilled Water: A Tutorial. Richard Gruskos Flow Products Manager Kessler Ellis Products

CHAPTER 3 BENEFITS OF BETTER BURNING

testo 350. For emission testing and combustion analysis. Portable Emission Analyzer

Safer, More Efficient Combustion Control for Fired Heaters

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

TVA Target Variable Area Flowmeter

Industrial Flowmeters

KURZ Thermal mass flowmeters aimed to improve combustion efficiency. AUTOMATION INSTRUMENTATION SUMMIT July 4th 2018 Gianantonio Favalessa

Boiler Tune-up Guide

METER SELECTION FOR VARIOUS LOAD REQUIREMENTS. Edgar B. Bowles, Jr. Southwest Research Institute 6220 Culebra Road San Antonio, TX USA

VERIS Accelabar. Superior Flow Measurement Accuracy

Saudi Aramco Uses Kurz to Help Monitor Flare Emissions

Fluid Flow Conditioning. August 2015

Saudi Aramco Uses Kurz to Help Monitor Flare Emissions

It can be reliably stated that experience in South African and international

PanaFlow MV82. Insertion Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Gilflo flowmeters. for steam, liquids and gases

What ensures measurement to accurate standards?

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

The Unique Accelabar Flow Meter

The Paradigm Case Method of Flowmeter Selection

measurement sensor and data transmission technology innovation has reduced installation costs, simplified maintenance and enhanced plant performance

CALDON LEFM Ultrasonic Flowmeters for Gas Applications. Integrating experience, proven technology, and innovation

This presentation covers process steam energy reduction projects supported by the Ameren Illinois ActOnEnergy program.

Table 1: Meter technology/flow media Air Water Carbon Dioxide Steam. Differential Pressure **

Averaging PITOT Tube 5RD series

Correctly Modeling and Calculating Combustion Efficiencies In Fired Equipment

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

USKON AKIŞKAN KONTROL SİSTEMLERİ SANAYİ VE TİCARET LTD. ŞTİ.

Proposed Guidelines for the Reduction of Nitrogen Oxide Emissions from Natural Gas fuelled Stationary Combustion Turbines

Flowmetering Choosing the right flowmeters to achieve targeted energy savings

True Performance in Flow Measurement. Verabar. Velocity Averaging Flow Sensors

FLARE GAS MEASUREMENT AND RECOVERY OF FUEL FEED GAS WITH RESIDUAL OXYGEN CALORIMETRY

Like piezoresistive, piezoelectric,

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

metals temperature limits.

Averaging PITOT Tube 5RD series

FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

DIVA flowmeter. for saturated steam flow measurement

Robust flue gas probes for industrial emissions measurements.

Lecture (6) on. Schematic of a Thermal Power Plant. By Dr. Emad M. Saad. Mechanical Engineering Dept. Faculty of Engineering.

Boiler and. steadily increases while the supply decreases energy

Multivariable: The Hot New Trend in Vortex Flowmeters. By Dr. Jesse Yoder

THERMAL EFFICIENCY IMPROVEMENT THROUGH FUEL GAS RATE AND EXCESS OXYGEN CONTROL

VortexMaster and SwirlMaster Natural gas measurement in power plants, boilers and incinerators

COMBIMASS Thermal Gas Flow

Gilflo ILVA flowmeters for steam, liquids and gases

FREQUENTLY ASKED QUESTIONS (FAQS)

Product range. Product range

A M E M B E R O F T H E K E N D A L L G R O U P

A beginner s guide to combustion optimization Improve efficiency, lower environmental impact, reduce downtime

A COMPARISON OF GAS ANALYSIS TECHNOLOGIES AVAILABLE FOR EFFICIENT AND SAFE COMBUSTION IN CONTROL FIRED HEATERS


Power Industry. Foxboro Field Devices for Measurement & Instrumentation Leading the Way in Power Generation Automation Solutions

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

PEI Candlestick (Utility) Flaring Systems (Theoretical by-products of combustion & destruction efficiency)

VORTEX Product Summary. vortex-shedding flow meters for gases, liquids and steam; in wafer, insertion, and in-line designs

Biogas A Wet Gas Environment for Thermal Flow Meters

Fundamental Overview of an NGL Meter Station Design Tony Lockard Enterprise Products 1100 Louisiana Street, Houston, TX

RUNYI GROUP. Main Features. STLU Vortex Flow Meter

Steam Power Station (Thermal Station)

About AMETEK/Thermox Worldwide Availability and Support Fuel Savings Calculator

Understand boiler performance characteristics. Use these suggestions when buying, designing or optimizing steam generators

CH88 In Situ Flue Gas Oxygen Transmitter

Not Just a Lot of Hot Air!

DVH. Multivariable Vortex Flowmeter

-SQA-SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NG NATIONAL CERTIFICATE MODULE DESCRIPTOR

Proven Flow Measurement Solutions for the Oil and Gas Industry

KEY APPLICATIONS OF FLOW COMPUTERS USED WITH MULTIPLE FLOW METER TECHNOLOGIES. Richard Gruskos Flow Products Manager Kessler Ellis Products

Chapter 2.1: Fuels and Combustion

THE UNIVERSITY OF JORDAN

Flow Conditioning Why, What, When and Where. Gas Flow Conditioning Why, What, When and Where

The effect of hydrogen containing fuel blends upon flashback in swirl burners. Nick Syred Cardiff School of Engineering Wales, U.K.

WI/CV Multiparameter Gas Analyzer System SG12WMTA-Series

Atmospheric Emissions from Stationary Combustion Turbines

Flow Test Data Book and Flow Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate

SBX 1000 In Situ Oxygen Transmitter

Mexico Gas Flaring Reduction. EU Flaring Regulatory Measurement Requirements & Best Practice Lynn Hunter

THERMAL FLOW MONITOR DESIGN AND PERFORMANCE IN ACID RAIN STACK

Tunable Diode Laser Technology. Direct Adsorbtion

CHAPTER 6 BOILER EFFICIENCY

Purpose of Today s Presentation

Improving Steel Reheat Furnace Performance with the ZoloSCAN-RHT Combustion Monitoring System

COIN. Flow Meters. Segmented Wedge. Your First Choice in Intelligent Flow Management...

PanaFlow Z3 Ultrasonic liquid flow meter. Ultrasonics 3. bhge.com

Setting The Standard

ASME PTC Flow Measurement

DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS

ACCEPTED MODERN TECHNOLOGY WOOD-FIRED BOILERS FOR POWER STATIONS SOUTHWOOD RESOURCES FORESTRY TASMANIA

Transcription:

A SAGE METERING White Paper SAGE METERING 8 Harris Court, Building D1, Monterey, CA 93940 Telephone: (831) 242-2030 www.sagemetering.com By Bob Steinberg, President, CEO November 13, 2012

Table of Contents Introduction 2 Combustion Control 2 Stoichiometric Combustion... 2 Excess Air and Air-to-Fuel Ratio... 3 Measuring Flue Gases 4 Measuring Air and Fuel Flow 5 Air Flow Monitoring... 5 Natural Gas Measurement... 5 Flow Technologies 5 Flow Meters... 5 Differential Pressure Meters... 6 Thermal Mass Flow Meters... 6 Conclusion 8 Introduction A significant way to reduce energy consumption in a manufacturing environment is to optimize the combustion control on industrial boilers, steam generators, furnaces, ovens, smelters and process heaters. Combustion efficiency and energy management is achieved through accurate and repeatable measurement of gases. Combustion Control By monitoring the air and fuel rates to burners, optimal air-to-fuel ratios are achieved, resulting in significant reductions in fuel gas cost, improved process efficiency, enhanced product quality, better yields, while simultaneously lowering combustibles. Many local and statewide jurisdictions have environmental regulations requiring flow meters on all medium and large heating units to measure plant wide emissions. Common applications for combustion control monitoring are found in a variety of industries including: textile, glass manufacturing, automotive, aluminum & steel, food & beverage, pulp & paper, power, chemical and refining. Stoichiometric Combustion The purpose of combustion is to efficiently consume fuel to produce heat. There are three components of combustion: fuel, oxygen and heat. The most common fuel sources in a combustion process are fossil fuels; natural gas, oil and coal. Fossil fuels are hydrocarbons; organic compounds containing carbon and hydrogen. To maximize the efficiency of combustion, it is important to consume (or burn) all the fuel, which is known as complete combustion. To achieve complete combustion it is critical to introduce air into the combustion chamber. Without it, the fuel will have partial or incomplete combustion and the exhaust gases will contain some unburnt and partially burnt fuel. Assuming we are evaluating a natural gas fed combustion process, the unburnt fuel

3 components will be carbon monoxide (CO), hydrogen (H 2 ) as well as methane (CH 4 ). Combustion efficiency is dependent upon using the right amount of air to consume the fuel. Fuel Consumption The presence of uncombusted or partially burnt fuel is indicative of incomplete combustion which greatly reduces efficiency. Therefore, burning the fuel in the presence of excess oxygen ensures that the fuel will achieve complete combustion. Minimize Excess Oxygen In the combustion process all excess air is heated in the combustion chamber and this energy is lost out the exhaust. For this reason, the second governing factor of combustion control is to minimize the extra oxygen used to reduce the loss of energy from heat going up the stack. Stoichiometric combustion is a theoretical point in which the optimum amount of oxygen and fuel mix generates the most heat possible and maximum combustion efficiency is achieved. There are no unburnt combustibles and no excess air. It is something to strive for, though in reality it does not occur. It is theoretical and in a real combustion process, the mixing between the air and fuel does not provide the perfect conversion. Excess Air and Air-to-Fuel Ratio In fuel-fired process heating the largest source of energy loss is through the exhaust stack, which is why managing air flow is critical to combustion efficiency. When fuel burns in the presence of oxygen it is converted to carbon dioxide, water and heat. Consider the combustion of methane (CH 4 ). CH 4 + 2O 2 CO 2 + 2H 2 O + Heat (1,013 Btu/ft. 3 ) Air contains approximately 21% oxygen and 79% nitrogen. In this case the reaction for complete combustion becomes: CH 4 + 2O 2 + 7.53N 2 CO 2 + 2H 2 O + 7.53 N 2 + Heat (1,013 Btu/ft. 3 ) The amount of air required will vary depending on the type of fuel. Ideally you would want to add enough oxygen to consume all the fuel so that little or no combustibles are exhausted, while minimizing the excess air to prevent energy loss out of the stack. Air-to-fuel ratio defines the amount of air needed to burn a specific fuel. The common fuels used in combustion process are: oil (#2, 4 and 6), diesel oil, gasoline, natural gas, propane, and wood. Ratios for common gases, liquid and solid fuels are noted on Table 1.1 and 1.2.

4 Table 1.1 Combustion ranges for common gases Fuel Methane (CH 4 ) Propane (C 3 H 8 ) Natural Gas Coke Oven Gas Stoichiometric Air/Fuel Ratio (air ft. 3 / fuel ft. 3 ) 9.53 1013 23.82 2590 Heat of Combustion (BTU/ft. 3 ) 9.4-11.0 950-1150 3.5-5.5 400-600 Table 1.2 Combustion ranges for Oil and Coal Fuel Stoichiometric Air/Fuel Ratio (air ft. 3 /fuel lb.) Heat of Combustion (BTU/lb.) No. 2 Oil 180-195 18,500-19,800 No. 6 Oil 170-185 17,500-19,000 Bituminous Coal 120-140 12,000-14,000 Optimizing Air-to-Fuel Ratio For any combustion process there is a balance sought between losing energy from using too much air, and wasting energy from running too rich. The optimum combustion efficiency occurs at the optimum air-to-fuel ratio and controlling this provides the best efficiency. In most scenarios, a liquid and gas fuel burner achieves this desired balance by operating at 105% to 120% of the optimum theoretical air. For natural gas fired burners the stoichiometric air required is 9.4-11 ft. 3 / 1.0 ft. 3 of natural gas, or approximately an air-to-gas ratio of approximately 10:1. This results in an excess oxygen level of 2%. In the combustion zone it is difficult to measure excess air. In the stack however, it can be easily measured using Oxygen analyzers. When operating with 5%-20% excess air, it would correlate to a 1% to 3% oxygen measurement in the stack. The optimum air-to-fuel ratio will vary at different operating loads. Tuning is the act of establishing the desired air-to-fuel relationship under different operating conditions. This can be accomplished when evaluating specifics in the stack: temperature, oxygen concentration as well as carbon monoxide and NO x emissions. Measuring Flue Gases By understanding the delicate balance of excess air-and-fuel usage, we can measure both the concentrations of the oxygen and combustibles in exhaust gas to develop air-to-fuel control strategy. The measurement of both O 2 and CO are critical measurements here. To maintain the highest combustion efficiency continuously, measurements of both flue gas oxygen and combustibles are required. When determining the carbon monoxide content from the flue gas we are able to make adjustments to the process operation because the CO content represents the unburnt fuel which is wasted because of insufficient air. Alternatively, by measuring the O 2 in the stack gas we are able to monitor the loss of energy from too much excess air Oxygen and combustible analyzers can provide continuous sampling and analysis of flue gases, making analyzing oxygen and combustibles in the stack gases a way to maximize combustion efficiency. Optimum combustion can be achieved at various air-to-fuel ratios to correspond with different operating loads. This makes it challenging to use oxygen analyzers alone to control excess air. Additionally, an uneven distribution of oxygen in the flue gas could result in oxygen level variations.

5 Measuring Air and Fuel Flow In the previous section we explored using flue gas measurements to control the air-tofuel ratio, here we investigate varying air and fuel pre-combustion flows to improve efficiency. Burner control systems optimize the air-to-fuel ratio for maximum efficiency and minimal unburnt combustibles. A ratio flow strategy is pivotal in safe and cost effective operation of fired heaters, furnaces, boilers and similar combustion processes. The first requirement is to establish process variable signals by measuring the mass flow of the fuel flow and combustion air flow rate. Since combustion is dictated by mass it is optimal to measure mass flow rather than volumetric flow. Mass flow measurement of natural gas and combustion air flow provides essential information for a facility to operate at maximum efficiency and minimal emissions. Air Flow Monitoring Measuring combustion air flow can be challenging because it is typical to have high flow rates at low pressures through irregular and large ducts. Swirls and turbulence in combination with insufficient straight runs make it difficult to obtain the desired flow profiles which can change with different operating loads. Calibration accuracy needs to be good, and repeatability is critical. Tuning the boiler optimizes the combustion efficiency. During combustion tuning the air-to-gas fuel rates are optimized at different boiler loads. Tuning includes measuring air and gas mass flow rates along with O 2 and CO concentration, NO X concentration (if appropriate), outlet temperature, and flue gas recirculation flow settings (if appropriate). In air flow monitoring, when setting the fuel flow the combustion air flow is tuned to match the gas flow to achieve the desired airto-gas ratio. The meter must provide repeatable flow measurement when operating at the same parameters on a different day. Natural Gas Measurement Measuring natural gas flow to the combustion source can be used to improve overall combustion efficiency. There is also a need to measure greenhouse gas emissions to comply with EPA requirements. Facilities emitting 25,000 metric tons of CO 2 e annually are required by the EPA to report annual emissions per EPA mandate 40 CFR Part 98. Additionally, local environmental authorities frequently require reporting natural gas consumption to determine emissions. Flow Technologies There are many flow technologies that can be used to measure gas flow and the main ones are noted below. While these meters are suitable for measuring natural gas flow, because of the higher volumes typical for combustion air and the larger duct sizes, most of these technologies are not suitable for combustion air flow measurement. Flow Meters Coriolis flow meters provide a direct mass flow measurement based upon the deflection force of the fluid moving through a vibrating tube. These meters are very accurate with high turndown capabilities and are independent of fluid properties. They are also very expensive to purchase and install, and are not suitable for larger pipe sizes. Positive Displacement meters require fluid to mechanically displace components and measure volumetric flow at the operating pressure and temperature. While they have good accuracy, pressure and temperature compensation would be required to obtain mass flow and since they have moving parts gas cleanliness needs to be considered.

6 Thermal Mass flow meters measure the mass flow based on heat transfer from a heated element. The measurement is in mass flow and additional pressure and temperature correction is not required. They also provide excellent accuracy and repeatability and are easy to install. Turbine Flow meters measure volumetric flow based on fluid flowing passed a freespinning rotor; each revolution corresponding to a specific volume of fluid. The meters have high turndown and accuracy. Unfortunately, because of the moving parts the meter s use is limited to clean dry gases only, and pressure and temperature compensation would be required. Ultrasonic Flow meters measure the difference in transit time of pulses that travel from a downstream transducer to the upstream transducer, compared to the time from the upstream transducer back to the downstream transducer. This style of meter is extremely accurate, but very expensive and pressure and temperature measurement would be required. Vortex Flow meter has a bluff object or shedder bar that is placed in the flow path and as gas flows around the shedder bar, vortices are cyclically generated from opposite sides of the bar. The frequency of vortex generation is a function of the gas velocity. The frequency of vortex shedding is independent of fluid composition. The meter however requires pressure and temperature compensation and requires a minimum flow rate to generate vortices. Differential Pressure Meters Differential pressure flow meters calculate flow by measuring pressure drop over an obstruction inserted in the flow path. Common types of flow elements are: orifice plates, flow nozzles, venturi tubes and averaging pitot tube. This technology can be used for both natural gas flow and combustion air flow. Orifice Plate is a differential pressure meter commonly used for natural gas measurement. It measures volumetric flow not mass flow. Limitations of this meter include: poor low flow sensitivity, limited turndown, creates pressure drop which impacts operating costs, and requires correction of pressure and temperature to obtain mass flow. Averaging Pitot Tube is a differential pressure flow measurement device commonly used for combustion air measurement. The instrument has limitations with gas flow; especially low flow sensitivity and turndown. The measurement is contingent upon achieving velocity pressure, and it is possible to not have sufficient velocity to obtain a suitable signal at low flow rates. For combustion air flow measurements, other flow elements or obstructions have been used; these include measuring the pressure drop across an elbow in the duct work, across a venturi built into the duct or even across turning vanes in the duct. Thermal Mass Flow Meters Thermal mass flow meters (TMFM) are ideally suited for measuring both natural gas flow and combustion air flow in combustion processes. Principals of TMFM Operation Thermal mass flow meters (TMFMs) measure gas flow based upon the principal of convective heat transfer. Either insertion style probes or inline flow bodies support two sensors that are in contact with gas. The sensors are resistance temperature detectors (RTDs), and the SAGE METERING (SAGE) sensors consist of highly stable reference-grade precision matched platinum windings that are clad in a protective 316 SS sheath for industrial environments.

7 The electrical power required to maintain this overheat represents the mass flow signal. There is no need for external temperature or pressure devices. One of the advantages of TMFMs is that they have no moving parts which reduce maintenance and permit their use in difficult application areas including wet (saturated) gas. They also do not require temperature or pressure corrections and provide good overall accuracy and repeatability over a wide range of flow rates. This style of meter measures mass flow rather than volume and is one of the few categories of meters that can measure flow in large pipes and ducts. One of the sensors is heated by the circuitry and serves as the flow sensor, while a second RTD acts as a reference sensor, and measures the gas temperature. The SAGE proprietary sensor drive circuitry maintains a constant overheat between the flow sensor and the reference sensor. As gas flows by the heated sensor (flow sensor), molecules of the flowing gas transport heat away from this sensor, the sensor cools and energy is lost. The circuit equilibrium is disturbed, and the temperature difference (ΔT) between the heated sensor and the reference sensor has changed. Within one second the circuit will replace the lost energy by heating the flow sensor so the overheat temperature is restored. SAGE provides TMFMs that are factory calibrated and configured for easy installation. They are ready to be installed direct into the pipe or duct without any need for field set up and calibration. SAGE offers insertion as well as inline TMFMs, with built-in flow conditioners that monitor the air and fuel flow rates to the burner. These direct mass flow meters are highly accurate and repeatable, and have negligible pressure drop. Sage Metering Prime 1/4 to 4 flow body with flow conditioner (NPT standard, flange optional) The SAGE meter has extraordinary rangeability of at least 100 to 1, and has the fast response

8 necessary for proper combustion control. Because of its low-end sensitivity, the SAGE TMFM can accurately measure extremely low velocity, down to 5 SFPM, making it extremely effective for measuring the low flow rates of air and natural gas which can occur at low boiler operating loads. In addition to the 4 20 ma control output of flow rate, the meters also provide pulsed outputs of consumption, and Modbus compliant RS485 RTU communications. The meters feature bright graphical displays of flow rate, totalized flow and gas temperature, plus, continuous diagnostics. For difficult to reach burner lines, or for locations with extreme radiant heat, SAGE also offers a remote style flow meter, with up to 1000 feet of lead length compensated cable all electronics and powering are done at the transmitter thus, the probe or flow body simply has a terminal junction box. Sage Metering Prime (SIP) with Insertion Probe Measuring Greenhouse Gas Emissions MFMs offer a reliable solution to measure gas mass flow for various environmental applications. As previously stated, the EPA requires reporting greenhouse gas emissions from many stationary combustion sources. When burning natural gas, bio gas or other gaseous fuels, the simplest method of determining Greenhouse Gas emissions is to measure the amount of fuel consumed and then using EPA formulas convert the fuel consumption to emissions of the various greenhouse gases. The SAGE meter fully complies with EPA reporting requirements using the built in totalizer as well as meeting EPA calibration requirements. Calibration Verification The SAGE TMFM comes from the factory fully calibrated and can easily verify that it maintains its original factory calibration through an in-situ calibration verification. All SAGE meters are able to perform the in-situ calibration check as long as a no flow (0 SCFM) condition can be created. No flow is easily created using an isolation valve assembly with the insertion meter style. Unlike other TMFMs, the SAGE In-Situ Calibration not only verifies that the unit is accurate; it also indicates that the sensor is clean. If the meter does not pass the calibration check the first time, in most cases simply cleaning the sensor, and re-testing will verify that the meter is accurate and hasn t drifted or shifted. Conclusion By assessing stoichiometric combustion, we understand the parameters needed to achieve optimum combustion to save energy, increase efficiency and reduce pollutants. Combustion efficiency and energy management is achieved by optimizing air-to-fuel ratios which are attained through accurate and repeatable gas flow measurement. Direct measurement of combustion air flow and fuel flow provide the criteria needed to reach peak efficiency. Thermal mass flow meters are ideal to measure the mass flow of combustion air and fuel gas, outperforming traditional flow meters in these applications.