SCOPE OF ACCREDITATION TO ISO/IEC 17020:2012 DELTA TESING LABS 23 South Macquesten Parkway Mount Vernon, NY 10550 Brandon Price 914 699 0056 INSPECTION BODY Valid To: October 31, 2019 Certificate Number: 3883.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this Type A (Third Party) inspection body for the following Special Inspections and has been assessed against the applicable New York City Special Inspection requirements for the specific inspections identified below: Description of Inspection Special Inspections General Building Wall Panels, Curtain Walls, and Veneers Exterior Insulation Finish Systems (EIFS) Specifications/ Rules of the City of New York, 1RCNY 101-06, Appendix A; New York City Building Codes; The International Building Codes (IBC) 2014 BC 1704.10 BC 1704.13 The inspection of quality, workmanship and requirements for construction. Materials, inspection and testing shall conform to applicable standards listed in the family of Codes based on the International Building Codes (IBC) and each state s modifications to these codes and to the rules of the Local Code Officials. Specifically, New York City Chapter 1 of Title 28 of the Administrative Code for additional provisions relating to materials, testing and inspections. Technical Practice 16 Wall Panels, Curtain Walls and Veneers Technical Practice 19 Exterior Insulation Finish Systems (EIFS) Chimneys BC 1704.26 Technical Practice 33 Chimneys Flood Zone Compliance BC 1704.29, G105 Technical Practice 36 Flood Zone Compliance Luminous Egress Path Markings BC 1704.30, 1024.8 Technical Practice 37 Luminous Egress Path Markings (A2LA Cert No. 3883.01) 08/14/2017 Page 1 of 4
Description of Inspection Specifications/ Fire Protection Systems & Fire-resistant Construction Sprayed Fire-Resistant Materials and Mastic and Intumescent Fire-Resistant BC 1704.11 BC 1704.12 Technical Practices 17 & 18 Sprayed Fire-Resistant Materials and Mastic and Intumescent Fire-Resistant Coatings s Coatings Smoke Control Systems BC 1704.15 Technical Practice 21 Smoke Control Systems Sprinkler Systems and Standpipe Systems Fire-resistant Penetrations and Joints Emergency and Standby Power Systems (Generators) BC 1704.23 BC 1704.24 BC 1704.27 BC 1704.31 New and altered sprinkler system shall be inspected in accordance with Sections 903 and 1704.23.1 And shall undergo successful hydrostatic pressure testing by a licensed master plumber or licensed fire suppression piping contractor in accordance with the requirements of this code, including Section 901.5, and NFPA 13 also including exception in 1704.23 New and altered standpipe systems shall be inspected in accordance with Sections 905 and 1704.24.1 The special inspector shall verify that the material and test certification forms have been transmitted to the Fire Department and the Department of Buildings. Seismic bracing shall be inspected in accordance with Section 1707.7 also including exception in 1704.24 Technical Practice 34 Fire-resistant Penetrations and Joints Technical Practice 38 Emergency and Standby Power Systems (Generators) Plumbing & Mechanical Systems Mechanical Systems BC 1704.16 Technical Practice 22 Mechanical Systems Fuel-Oil Storage & Fuel-Oil Piping Systems Private On-site Storm Water Disposal Systems and Detention Facilities and Individual On-site Private Sewage Disposal Systems Installation BC 1704.17 BC 1704.21.2 BC 1704.22 Technical Practice 23 Fuel-Oil Storage and Fuel-Oil Systems Testing of fuel storage tanks and piping shall be performed in accordance with Section 1308 of the New York City Mechanical Code. Special inspection of seismic bracing shall be performed in accordance with Section 1707.7. Technical Practice 27 Private On-site Storm Water Disposal Systems and Detention Facilities and Individual On-site Private Sewage Disposal Systems Heating Systems BC 1704.25 Technical Practice 32 Heating Systems (A2LA Cert No. 3883.01) 08/14/2017 Page 2 of 4
Description of Inspection Specifications/ Structural Material & Construction Operations Welding: Steel, Highpressure BC 1704.3.1 Steam Piping, High- BC 1704.18 temperature Hot Water BC 1704.19 Piping, High-pressure Gas BC 1704.28 Piping and Aluminum Technical Practice 1 Welding Welding Inspection shall be in compliance with AWS D1.1. Structural Steel-Detail BC 1704.3.2 Technical Practice 2 Structural Steel-Detail Structural Steel-High Strength Bolting BC 1704.3.3 Technical Practice 3 Structural Steel-High Strength Bolting Installation of high-strength bolts in accordance with this section and AISC 360, also including exceptions pertaining to section 1704.3.2 Structural Cold-Formed Steel BC 1704.3.4 Technical Practice 4 Cold-Formed Steel Compliance with filed plans Concrete-Cast-in-Place and Precast BC 1704.4 Technical Practices 5 & 6 Concrete-Cast-in-Place and Precast s Prestressed Concrete BC 1704.4 Technical Practice 7 Prestressed Concrete Masonry BC 1704.5 Technical Practice 8 Masonry Wood Construction- Prefabricated Wood I-Joists, Metal-plate Connected Wood Trusses, and High-load Diaphragms Subsurface Conditions- Subgrade Inspection Subsurface Conditions-Fill Placement, In-Place Density BC 1704.6 BC 1704.7.1 BC 1704.7.2, 1704.7.3 Technical Practices 9 & 10 Wood Construction s Technical Practice 11 Subsurface Conditions-Subgrade Inspection Technical Practice 12 Subsurface Conditions-Fill Placement, In-Place Density Deep Foundation BC 1704.8 BC 1808 BC 1809 BC 1810 Technical Practice 13 Deep Foundations Vertical Masonry Foundations BC 1704.9 Technical Practice 15 Vertical Masonry Foundations (A2LA Cert No. 3883.01) 08/14/2017 Page 3 of 4
Description of Inspection Structural Stability-Existing Buildings, Mechanical Demolition, and Raising and Moving of a Building Excavation-Sheeting, Shoring and Bracing Specifications/ BC 1704.20.2 BC 3304.4.1 BC 1704.20 BC 1704.20.6-1704.20.10 BC 3304.4.1 Technical Practice 24 Structural Stability-Existing Buildings, Mechanical Demolition and Raising and Moving of a Building Existing building shall be subject to special inspections in accordance with Sections 1704.20.6 through 1704.20.10 Technical Practice 28 Excavation-Sheeting, Shoring and Bracing Seismic Isolation Systems BC 1704.8 Technical Practice 40 Seismic Isolation Systems Post-installed Anchors- Concrete and Masonry BC 1704.32 Technical Practice 39 Post-Installed Anchors Standard Specification for Agencies Engaged in Construction Inspection, Testing or Special Inspection ASTM E329 This specification defines the minimum requirements for agencies engaged in: a) Inspection of construction activities and materials used in construction, b) Testing of construction activities and materials used in construction, and c) Special Inspection (A2LA Cert No. 3883.01) 08/14/2017 Page 4 of 4
Accredited Inspection Body A2LA has accredited DELTA TESTING INC. DBA DELTA TESTING LABS Mount Vernon, NY for technical competence in and compliance with the Inspection Body Accreditation Program This inspection body is accredited in accordance with the recognized International Standard ISO/IEC 17020:2012 Conformity Assessment for the operation of various types of bodies performing inspection. This accreditation demonstrates technical competence for a defined scope and the operation of a quality management system. Presented this 14 th day of August 2017. President and CEO For the Accreditation Council Certificate Number 3883.01 Valid to October 31, 2019 For the inspections to which this accreditation applies, please refer to the organization s Inspection Body Scope of Accreditation.