LEWIS Dovetailed sheeting. Dovetailed Sheeting

Similar documents
LEWIS Dovetailed sheeting. Dovetailed Sheeting

Structural Steel Products UK & Ireland. Multideck Technical Handbook

FERMACELL DRY FLOORING ELEMENTS: IMPROVED LIVING CONDITIONS THROUGH BETTER ACOUSTIC AND THERMAL INSULATION. Dry Lining

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES

SCREED A. The ideal free-flowing floor screed

September Saddle Flooring Systems

Multideck 146. Contents

September Reflex Bearers

3.4.2 DESIGN CONSIDERATIONS

Structural Products. Multideck 50-V3 Galvanised Steel Floor Decking System

ROCKFLOOR. Thermal and acoustic stone wool insulation for ground and separating floors

a new liquid screed solution

The ultimate free-flowing floor screed

a new liquid screed solution from

ACOUSTIC INSULATION UNDER SCREED made from recycled rubber granules

Suspended timber upper floors

LEWIS structural covering floor

Acoustic Cradle Levelling System

Most products will act differently when installed over an UFH system than when installed on a standard unheated subfloor.

SoundPro CDM-ISO-LAT. Acoustic solution for floating isolated floors

CHAPTER 3 BEHAVIOUR OF FERROCEMENT HOLLOW SLABS

No reinforcement required 40mm minimum - Commercial applications. 35mm minimum - Domestic applications.

Metal Web Floor System

The SoundBar System HIGH PERFORMANCE ACOUSTIC FLOORING SOLUTION

June Non - Residential Refurbishment Separating floors

Jabfloor 70, 100, 150, 200, 250

OS Thermal System Installation Guide

Civil Engineering Construction Chapter 5

ELASTICALLY SEPARATED FLOOR

The Passive Fire Protection Handbook

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor 70, 100, 150, 200, 250

Jabfloor 70, 100, 150, 200, 250

Garage Conversion - Between and Under Joist Applications

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor Premium 70 and 100

Technical Manual. The difference is.

a new liquid screed solution from

Selecting floors and ceilings

REGUPOL ACOUSTIC UNDERLAY COLLECTION IMPACT SOUNDPROOFING FLOORS

2016 DESIGN AND DRAWING OF REINFORCED CONCRETE STRUCTURES

Sizing an underfloor heating SyStem

GypWall TM ROBUST 4.4. GypWall ROBUST. Durable impact resistant partition system. Key facts. Sector Guide

REGUPOL ACOUSTIC UNDERLAY COLLECTION IMPACT SOUNDPROOFING FLOORS

FORMDECK. constructions. constructions

Polyfoam Floorboard For thermal insulation of floors

Jabfloor is also available in higher grades up to Jabfloor 250 which may be required in certain specialist industrial and commercial applications.

SINTEF Building and Infrastructure confirms that. Separating floors with Hunton Silencio 36 / Hunton Silencio Thermo

Jabfloor 70, 100, 150, 200, 250

Part 5 Substructure and ground floors. Chapter 5.2. Suspended ground floors

Technical data sheet with laying instructions

RMF Intercell. NBS Specification 2013 K41

ThermaSheet. multi-purpose insulated tile backer panels

robustdetails E-FC-6 Separating Floor Concrete Separating Floors Concrete E-FC-6 SYSTEM INSTALLATION

June Residential Refurbishment Separating floors

- Toron Suspended floor Construction & Datasheets - FoilBoard Suspended ECO floor Construction & Datasheets

exceed your energy performance levels

Xtratherm Thin-R Underfloor Board (XT/UF Grade)

Dwelling-houses and flats performance standards for separating walls, separating floors and stairs that have a separating function.

REGUPOL ACOUSTIC UNDERLAY COLLECTION SOUNDPROOFING SCREED AND TILED FLOORS

April Section 4.1. Ground Floors

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

ComFlor manual Composite floor decking design and technical information

HOLLOW CORE FLOORS SPEED AND STRENGTH

* lion (EU) No 305/2011 * * sation fortechnical * fermacell flooring systems. Fermacell GmbH Dosseldorfer Landstra~e Duisburg DEUTSCH LAND

15 days 75% Compressive Strength 1 day 23N/mm² 28 days 44N/mm²

GenieMat FF. Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation. It s not magic, it s engineering. Impact Sound Control

Loadbearing timber joist floors

Regupol CONSTRUCTION. Regupol BA. Heavy duty screed isolation. Regupol BA. Excellent impact performance.

CLASSIFICATION OF FIRE RESISTANCE ACCORDING TO EN : 2007+A1:2009 OF A LOAD BEARING THERMAL INSULATED CONCRETE FLOOR; REPPEL OP-DECK

FLOOR STRUCTURES. Floor structures Building Construction I.

Prestressed Hollowcore Slabs PRECAST CONCRETE SOLUTIONS.

R&M Floor Systems Compact:

Specialist products. Proven expertise. Acoustic flooring systems to meet the 2010 Scottish Standards - Section 5

R979SY011 SPIDER R979SY001 SPIDER R979SY021 SPIDER

GypFloor SILENT 6.4. Sound insulating floor system. Key facts. Sector Guide

BISON PRECAST FLOORING SPECIFICATION

Section : 100 TRESHOLD STAIRS DEPARTMENT NGL HALLWAY TOWARDS MUSEUM FFL DISABLED WC FEMALE WC MALE WC FFL 95.

TECHNICAL INFORMATION SCREED

Jabfloor High Performance (HP) 70 and 100

HAMBRO COMPOSITE FLOOR SYSTEM

Eco-Versal. insulation. Polyisocyanurate (PIR) foam core with aluminium foil composite to both sides BASELINE TOPLINE SLIMLINE

HOW TO: CREATE METAL PARTITIONS WALL LININGS AND CEILINGS GTEC FRAMES

PIR Insulation. XT/UF Insulation for Ground Supported and Suspended Floors. Floors 08/ /0183

Refurbishment site guidance for solid-walled houses ground floors

Part 1: Vocabulary Select the best answer and write the corresponding letter in the space provided.

BEAM & BLOCK SYSTEM. 108mm. 175mm Deep (160mm) Wide Beam. 160mm

Solid Floor Systems. Underfloor heating for solid or screeded floors. Clip rail and staple system. Red Floor Panel

Structural Calculations for standard BALCONY 1 system handrail using 55mm diameter posts (48.3mm x 5mm CHS) & 150 x 150 x 15mm base plates

Product Manual. Underfloor Heating (UK) Floor Construction. Industrial - Commercial - Domestic

Floor SoundprooFIng Made Simple

Superior Performance Phenolic Insulation SR/UF. Insulation for Ground Supported and Suspended Floors. Floors AS LOW AS 10/4803

Technical Manual - Section 6. Lytag LWAC in Steel Decking and Composite Floors

Detail Sheet 1 / Ballytherm BTF Floor Insulation

May Danskin. Thermal Saddle System. Level, insulate and reduce air leakage and all with one flooring system. Danskin

The difference is Guidance for the preparation of Deck Manufacturing Schedules

Insulation - Products

INNOVATIVE PROFILES. Schlüter -DITRA-SOUND. Bonded impact sound insulation

155 & 220 Beam Flooring Systems

Part E robustdetails. robustdetails. January 2018 Update Pack

Transcription:

Dovetailed Sheeting LEWIS Dovetailed sheeting As part of a joisted floor construction, LEWIS Dovetailed metal decking provides a first class solution for ACOUSTICS, FIRE PROTECTION and works well with UNDERFLOOR HEATING AND COOLING systems. LEWIS Dovetailed metal decking solutions are used in a range of applications including renovations and conversions, traditional new build, timber frame, steel frame and other off-site building systems, ICF and modular construction and mezzanine floors.

LEWIS Dovetailed Sheeting The unique LEWIS profile with its optimal geometry provides a combined action between the LEWIS deck and the concrete/ screed ensuring an extremely high load bearing capacity. 26 38 9 x 64 = 576 standard profile 30,5 A LEWIS composite floor consists of the LEWIS cold rolled steel sheet covered with a relatively 27,5 30 34 thin layer of C20/25 fine grade aggregate concrete or CA25F4 free flowing, selflevelling, liquid screed. 16 During the curing period the LEWIS deck acts as shuttering, but once the concrete/screed has cured, locking into the LEWIS deck it forms an extremely strong, composite, structurally sound floor, i.e. it becomes reinforcement for the concrete/screed. All in mm detail The use of fine grade aggregate concrete can also provide a monolithic finish to provide a finished floor option. The overall depth of a LEWIS composite floor can be relatively thin mm in most cases. Common Applications Acoustic separating floors Fire resistant floors Bespoke Green Guide A+ rated sustainable floors Can easily also include underfloor heating Suitable sub-floor for ceramic or stone tiles, timber or laminate floor finishes. Can be used as a structural floor element within the building Mezzanine floors Bathrooms and wet-rooms Suitable for traditional, off-site construction and conversion projects Raised ground floors Fire Resistance LEWIS Dovetailed Sheeting makes it possible to design a composite floor meeting UK standards without complicated details. Generally a fire resistance of 60 120 minutes is achievable with all standard LEWIS details. Fire tests certification meeting EN 131-2 are available. Acoustics Best results are achieved by laying a LEWIS composite floor as a floating Floor, creating separation between the supporting floor, joists or beams with the introduction of resilient strips. Strips are laid directly to the existing timber floor or placed on top of any supporting joist/beam. The type of resilient strip is determined by the required acoustic and load bearing performance requirements. When looking at an existing floor or timber joists LEWIS High Density Mineral Wool Strip is the most likely solution. When looking for a higher acoustic performance or when the joist/beam spans exceed 800 mm and the load bearing capacity will exceed 2.5 Kn/m 2 there are a range of specialist solutions such as LEWIS Sylomer TSS resilient strips or LEWIS recycled rubber granulate strips. A range of acoustic strips are available for use with light gauge steel or structural steel beams details on application. Apart from standard domestic separating floors, LEWIS provides exceptional solutions for bespoke acoustic floors within live music venues, night clubs, restaurants, recording studios, recreational performance studios, specialist test labs, plant rooms and many other commercial applications.

Features Low dead weight Thin floor thickness ( mm) High permissible loads Spans of up to 20 mm High impact and airborne sound insulation Up to 120 minutes fire resistance Easy to install Manufactured from high quality galvanised steel Wet Rooms LEWIS Dovetailed Sheeting composite floors are ideal for wet rooms or bathrooms in existing or new build construction. Sheets are placed on the existing floor or used as a replacement for timber decks. An exceptional waterproof wall to floor joint is created by the use of a simple damp proof membrane worked into the concrete/screed and bonded to the walls. The floor and walls are now ready for tiling or other final finishing with no fear of movement or cracking. Stiff and high load bearing, ideal for all tile options Floors ready for final finishing Floor thicknesses from only 36 mm Spans joists or laid direct to the existing floor Easy to incorporate underfloor heating Excellent acoustic performance Underfloor Heating and Cooling Underfloor heating is becoming commonplace in modern residential, commercial and public building projects. A LEWIS solution allows all of the efficiencies of a ground floor to be constructed on the upper floors. Pipes are secured to the upper flanges of the sheet, fixed using a simple pipe clip or rail fixing system. A minimum 20 mm of concrete / screed coverage is all that is required above the pipes. An even spread of heat is transferred from pipes to sheets and within the floor slab. Floor thickness typically 52 mm (with typical 16 mm pipes) Provides a thermal mass Even spread of heat eliminating cold spots Easy to install

Renovation and Conversions LEWIS composite floors provide an excellent solution when looking to upgrade acoustic and fire protection performance to separating floors during the renovation or conversion of existing buildings. LEWIS composite floors make it possible to create light weight, cost effective and easy installed floating floor on top of the existing floor construction. If floor to ceiling heights are an issues the existing floor boards can be removed with the LEWIS deck then laid directly to the joists. A standard LEWIS floor type detail LWS-BO easily achieves UK requirements for acoustic and fire resistance for residential separating floors. Higher performance standards are easily achievable. Easily achieves UK standards for acoustic and fire performance. Low dead loads Ideal for all renovation, conversion and new build applications including timber frame, SIPS and ICF building systems. LWS B0 LEWIS decking on LEWIS mineral wool resilent strips Properties Airborne sound D n + C 47 tr D n 54 Impact sound L n Fire resistance F 60 minutes LWS Sylomer 1 LEWIS decking on Sylomer TSS resilent strips Properties Airborne sound D n + C 62 tr D n 73 Impact sound L n 47 Fire resistance F 60 minutes

LAMINEX B.V. Bauaufsichtliche Zulassung Nr.Z-26.1.36 Steel and Modular Construction LEWIS provides exceptional solutions for light gauge steel framed off-site, modular and volumetric building systems. A high load bearing capacity combined with a low dead load makes LEWIS an ideal choice when incorporating a concrete/screed floor within LGSF or Modular systems. Low dead load from 0.90 kn/m 2 Floor thickness from mm High permissible loads Spans up to 20 mm Used in floor cassettes Method of installation Please see the separate leaflet providing the recommended method of installation. Detailed instruction is given on the laying, jointing and fixing of the sheets, types of concrete and screed. Additional technical advice is available on request. Certification and Reports The production facility is ISO 9001 certified and the LEWIS system is fully tested and carries the following certification: BUtgb MPA BAU HANNOVER

Design information Table 1: Permissible uniformly distributed load Table 3: Design table span L in (mm) slap depth D in (mm) permissible load Qk in kn/m 2 (excl. partial factor) no free edges free edges*** d = mm d = mm d = mm d = mm 600 900 1200 10 2000 20* 36,2 22,7 14,8 10,6 11,3 8,2 category A1, A2 A3 actions 1,5 kn/m 2 2,0 2,0 kn/m 2 2,0 reinforced* reinforced* reinforced** reinforced** assumptions: concrete strength class C20/25 partial factors ξ γq = 1,25 en γq = 1,5 (consequence class CC2) A4 B1 2,0 kn/m 2 2,7 2,5 kn/m 2 2,7 Table 2: Permissible span L in (mm) 600 900 1200 10 2000 20* slap depth D in (mm) permissible Qk in (kn) excl. partial factor no free edges free edges reinforced* 3,8 5,7 2,3 3,6 5,5 2,2 3,5 5,4 2,1 3,4 5,3 2,0 4,4 6,5 ** 4,2 6,3 ** * reinforcement mesh Ø5-1 (Q131) or Ø6-200 (A142) ** failure mode transverse bending is not considered for these spans assumptions: partial factors ξ γq = 1,25 en γq = 1,5 (consequence class CC2) load area dimensions mm x mm concrete strength class C20/25 reinforced* 3,3 3,2 3,1 3,1 3,6 3,5 Technical details nominal width : 630 mm effective width : 580 mm standard lengths : 1,300 mm 2,0 mm length range : 800-6,000 mm dimensional tolerances : length : 1-4 mm width : 1-3 mm moment of inertia : l x = 3.6 cm 4 /m 1 moment of resistance : W x = 3.0 cm 3 /m 1 steel gauge : 0.5 mm height of profile : 16 mm flange width : 38/34 mm weight : 0.058 kn/m 2 minimum fine grade concrete thickness: 16 mm profile height + 34 = mm. For composition and quality of concrete see separate application instructions. B2 C11 C12 C13 C21 C22 C31 C32 C33 C34 C35 C36 C37 C38 C39 C41 C42 C51 D1, D2 3,0 kn/m 2 2,7 2,0 kn/m 2 3,0 2,5 kn/m 2 4,0 3,0 kn/m 2 3,0 4,0 kn/m 2 3,6 3,0 kn/m 2 2,7 3,0 kn/m 2 4,5 3,0 kn/m 2 4,0 4,0 kn/m 2 4,5 5,0 kn/m 2 4,5 SOUND INSULATION ISOLATION FIRE RESISTANCE KG. LOAD BEARING Unit 48C Avenue 4 Chilton Industrial Estate Co. Durham DL17 0SQ Telephone: 01388 728833 Fax: 01388 728834 E-mail: info@cdi-icm.co.uk Website: www.cdi-icm.co.uk REP 016.09 UK 4,0 kn/m 2 4,0 3,0 kn/m 2 2,0 5,0 kn/m 2 3,6 7,5 kn/m 2 4,5 4,0 kn/m 2 4,5 5,0 kn/m 2 3,6 5,0 kn/m 2 7,0 5,0 kn/m 2 3,6 4,0 kn/m 2 3,6 * reinforcement mesh Ø5-1 (Q131) or Ø6-200 (A142) for whole floor area ** only reinforcement mesh (Q131 or A142) needed at free edges (over width of sheeting) *** free edges can be avoided with suporting beams along the free edges assumptions: maximum span 10 mm actions according to NA to BS EN 1991-1:2002 partial factors ξ γq = 1,25 en γq = 1,5 (consequence class CC2) area dimensions mm x mm concrete strength class C20/25 L<1 m L<1 m L<1 m L<1 m L<1 m L>1 m L>1 m L>1 m L>1 m L>1 m Steel quality: S320GD + Z100 N-A-C according to NEN-EN10147 Z2 available on request. LEWIS is a registered trademark of Reppel b.v. Dordrecht, The Netherlands www.reppel.nl WATER RESISTANCE