SCOPE OF ACCREDITATION TO ISO/IEC 17020:2012 SPECIAL TESTING & CONSULTING, LLC. 144 Toledo Street Farmingdale, NY 11735 Sebastian Setteducate, P.E. 631-755-1112 INSPECTION BODY Valid To: September 30, 2019 Certificate Number: 3516.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this Type A (Third Party) inspection body for the following Special s and has been assessed against the applicable New York City Special requirements for the specific inspections identified below: Description of Special s Steel - Welding Steel - Details Activities Rules of the City of New The inspection of quality, York, 1RCNY 101-06, workmanship and requirements for Appendix A; New York construction. Materials, inspection City Building Codes; The and testing shall conform to International Building applicable standards listed in the Codes (IBC) 2014 family of Codes based on the International Building Codes (IBC) and each state s modifications to these codes and to the rules of the Local Code Officials. Specifically, New York City Chapter 1 of Title 28 of the Administrative Code for additional provisions relating to materials, testing and inspections. SPECIAL INSPECTIONS BC 1704.3.1 and Special Testing Procedure 19.0 BC 1704.3.2 and Special Testing Procedure 23.0 (A2LA Cert. No. 3516.01) 11/22/2017 Page 1 of 6
Steel High Strength Bolting Cold-Formed Steel BC 1704.3.3 and Special Testing Procedure 24.0 BC 1704.3.2, 1704.3.4; Procedure 25.0 Concrete Cast-in-Place BC 1704.4; BC 1704.4.1, BC 1704.4.2, Table 1704.4 Procedure 29.0 Concrete Precast BC 1704.4 and Special Testing Procedure 29.0 and 30.0 Concrete Prestressed Masonry Wood High-load Diaphragms Wood Metal-plate Connected Wood Trusses Wood Prefabricated Wood I- Joists Subsurface Conditions Subgrade Subsurface Conditions Fill Placement, In place Density BC 1704.4 and Special Testing Procedure 31.0 BC 1704.5; and Special Testing Procedure 32.0 BC 1704.6.1; and Special Testing Procedure 36.0 BC 1704.6.2; and Special Testing Procedure 33.0 and 34.0 BC 1704.6.3; and Special Testing Procedure 33.0 and 35.0 BC 1704.7.1; and Special Testing Procedure 37.0 BC 1704.7.2, BC 1704.7.3 1803.5; and Special Testing Procedure 38.0 Activities (A2LA Cert. No. 3516.01) 11/22/2017 Page 2 of 6
Subsurface Investigations, Borings & Test Pits BC 1704.7.4 BC 1802; BC 1704.21.1.1, Deep Foundations BC 1704.8 BC 1808, 1809, 1810; and Special Testing Procedure39.0 and 40.0 Helical Piles (BB#2014-200) Vertical Masonry Foundation Wall Panels, Curtain Walls and Veneers Sprayed Fire-resistant Materials Mastic and Intumescent Fire-resistant Coating BC 1704.8.5 and Special Testing Procedure 40.0 BC 1704.9; and Special Testing Procedure 40.0 BC 1704.10; and Special Testing Procedure 1.0 BC1704.11, and Special Testing Procedure 5.0 BC 1704.12 and Special Testing Procedure 4.0 Activities Exterior Insulation Finish (EIFS) BC 1704.13; and Special Testing Procedure 2.0 Alternative Materials BC 1704.14 Smoke Control BC 1704.15; BC 909; and 6.0 BC 1704.16, 507.16, NYCMC 1011, 1018, 1208; Procedure 12.0 & Fire- Plumbing & (A2LA Cert. No. 3516.01) 11/22/2017 Page 3 of 6
Fuel-Oil Storage & Fuel-Oil Piping High-Pressure Steam Piping (Welding) High-Temperature Hot Water Piping (Welding) High-Pressure Fuel-Gas Piping (Welding) Stability Existing Buildings Excavation-Sheeting, Shoring and Bracing BC 1704. 17, 1707.7; Manufacturer Instructions; Procedure 13.0 BC 1704.18, and Special Testing Procedure 20.0 BC 1704.18 and Special Testing Procedure 20.0 and 21.0 BC 1704.19 and Special Testing Procedure 21.0 BC 1704.20.1 and Special Testing Procedure 42.0 BC 1704.20.2 and Special Testing Procedure 43.0 Underpinning BC 1704.20.3-BC 1814 Procedure 41.0 Demolition Raising and Moving of a Building Soil Percolation Test Private On-Site Storm Water Disposal and Detention Facilities, Individual On-Site Private Sewage Disposal Installation BC 1704.20.4 and Special Testing Procedure 42.0 BC 1704.20.5 BC 1704.21.1.2 and 14.0, 15.0 and 16.0 BC 1704.22 and Special Testing Procedure 16.0 Activities Plumbing & (A2LA Cert. No. 3516.01) 11/22/2017 Page 4 of 6
Soil Percolation Test Individual On-Site Private Sewage Disposal Installation Sprinkler Standpipe System Heating Chimneys Fire-resistant Penetrations and Joints Aluminum Welding Flood Zone Compliance Luminous Egress Path Markings Emergency and Standby Power (Generators) Post-Installed Anchors (BB# 2014-018, 2014-019) Seismic Isolation BC 1704.22 and Special Testing Procedure 16.0 BC 1704.23 and Special Testing Procedure 8.0 BC 1704.24 and Special Testing Procedure 7.0 BC 1704.25; 1707.7 and 47.0 BC 1704.26, 1707.7 and 3.0 BC 1704.27 and Special Testing Procedure 9.0 BC 1704.28 and Special Testing Procedure 22.0 BC G105 BC 1704.29 and 48.0 BC 1704.30; BC 1024.8 Procedure 4.0 BC 1704.31, 1707.7; 2702 Procedure 11.0 BC 1704.32 BC 1707.8 and Special Testing Procedure 44.0 Activities Compliance with filed plans (A2LA Cert. No. 3516.01) 11/22/2017 Page 5 of 6
Activities PROGRESS INSPECTIONS Preliminary 28-116.2.1 and BC 110.2 Footing and Foundation BC 110.3.1 Lowest Floor Elevation BC 110.3.2 Wood Frame BC 110.3.3 Fire-Resistance Rated BC 110.3.4 Public Assembly 28-116.2.2 Emergency Lighting Final 28-116.2.4.2, BC 110.5, Directive 14 of 1975 and 1 RCNY 101-10 Ultrasonic Magnetic Particle Liquid Dye Penetrant Standard for Agencies Engaged in, Testing or Special Standard for Agencies Engaged in and/or Testing NON-DESTRUCTIVE TESTING 26.0 27.0 28.0 ASTM ASTM E329 This specification defines the minimum requirements for agencies engaged in: a) of construction activities and materials used in construction, b) Testing of construction activities and materials used in construction, and c) Special ASTM E329-07 This specification defines the minimum requirements for inspection agency personnel or testing agency laboratory personnel, or both, and the minimum technical requirements for equipment and procedures utilized in the testing and inspection of construction and materials used in construction. s s s s s s s NDE s NDE s NDE s (A2LA Cert. No. 3516.01) 11/22/2017 Page 6 of 6
Accredited Body A2LA has accredited SPECIAL TESTING & CONSULTING, LLC. Farmingdale, NY for technical competence in and compliance with the Body Accreditation Program This inspection body is accredited in accordance with the recognized International Standard ISO/IEC 17020:2012 Conformity Assessment Requirements for the operation of various types of bodies performing inspection. This accreditation demonstrates technical competence for a defined scope and the operation of a quality management system. Presented this 22 nd day of November 2017. President and CEO For the Accreditation Council Certificate Number 3516.01 Valid to September 30, 2019 For the inspections to which this accreditation applies, please refer to the organization s Body Scope of Accreditation.