Demand side management for smart district heating

Similar documents
Analysis of a plus-energy house for improved building and HVAC system design

Modeling energy flexibility of low energy buildings utilizing thermal mass

Development of a hot water tank simulation program with improved prediction of thermal stratification in the tank

Human response to individually controlled micro environment generated with localized chilled beam

Challenges in Smart Low-Temperature District Heating Development

Low energy class 1 typehouses according to the Danish building regulations

Comsol Multiphysics for building energy simulation (BES) using BESTEST criteria Jacobs, P.M.; van Schijndel, A.W.M.

Side by side tests of two SDHW systems with solar collectors with and without antireflection treatment

Sensitivity of energy and exergy performances of heating and cooling systems to auxiliary components

Aggregation of building energy demands for city-scale models

Passive Houses for Arctic Climates

Testing, development and demonstration of large scale solar district heating systems

Investigations of Intelligent Solar Heating Systems for Single Family House

Multi-angled façade system for office building renovation Hannoudi, Loay Akram; Christensen, Jørgen Erik; Lauring, Gert Michael

Potential of Natural Ventilation in Shopping Centres Diederichsen, Alice; Friis, Kristina; Brohus, Henrik; Tranholm, Gitte T.

Next Generation District Heating

Field measurements of moisture variation in cold ventilated attics with different ceiling constructions

Dynamic Heat Production Modeling for Life Cycle Assessment of Insulation in Danish Residential Buildings

Calculation of the yearly energy performance of heating systems based on the European Building Directive and related CEN Standards

Measured temperature and moisture conditions in the roof attic of a one-and-a-half story house Nielsen, Anker; Morelli, Martin

Thermal indoor environment and energy consumption in a plus-energy house: cooling season measurements

Investigation and Retrofitting Proposal for a Panbo Type House in Sisimiut, Greenland

Laboratory Testing of Solar Combi System with Compact Long Term PCM Heat Storage

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

COMPARATIVE SUMMER THERMAL AND COOLING LOAD PERFORMANCE OF NATURAL VENTILATION OF CAVITY ROOF UNDER THREE DIFFERENT CLIMATE ZONES

Laboratory Test of a Cylindrical Heat Storage Module with Water and Sodium Acetate Trihydrate

A lime based mortar for thermal insulation of medieval church vaults

Individually controlled localized chilled beam in conjunction with chilled ceiling: Part 1 Physical environment

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Aalborg Universitet Investigation of Different Configurations of a Ventilated Window to Optimize Both Energy Efficiency and Thermal Comfort

Simulation Study of Discharging PCM Ceiling Panels through Night - time Radiative Cooling

Performance assessment of a ventilated mattress for pollution control of the bed microenvironment in healthcare facilities

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM AND HEAVY MASS BUILDING IN BELGRADE

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Impacts of Renewable Energy Quota System on China's Future Power Sector

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE

Working in a broad partnership in the Kenya Miniwind Project

Thermal Models for Intelligent Heating of Buildings

Roels, Staf ; Bacher, Peder; Bauwens, Geert ; Madsen, Henrik; Jiménez, María José

Thermal Environment evaluation in commercial kitchens

Published in: NSB 2014: 10th Nordic Symposium on Building Physics, June 2014, Lund, Sweden

Introduction to Pinch Technology

Energy Consumption and Indoor Environment Predicted by a Combination of Computational Fluid Dynamics and Building Energy Performance Simulation

Dynamic Model-Driven Energy Retrofit of Bøgevangen and Runevej Daycare Centers in Aarhus

Moisture supply in Danish single-family houses the influence of building style Hansen, Ernst Jan de Place; Møller, Eva B.

Performance of radiant cooling ceiling combined with personalized ventilation in an office room: identification of thermal conditions

Low energy buildings

Dynamic facades, the smart way of meeting the energy requirements Johnsen, Kjeld; Winther, Frederik Vilbrad

Parametric analysis of the operation of nocturnal radiative cooling panels coupled with in room PCM ceiling panels

Tårs m2 CSP + Flat Plate Solar Collector Plant - Cost-Performance Optimization of the Design

Individually controlled localized chilled beam in conjunction with chilled ceiling: Part 2 Human response

Thermo Active Building Systems Using Building Mass To Heat and Cool

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Two-Pipe Chilled Beam System for Both Cooling and Heating of Office Buildings

Chapter 6. Space heating load

Aalborg Universitet Two-Pipe Chilled Beam System for Both Cooling and Heating of Office Buildings General rights Take down policy

Published in: NSB 2014: 10th Nordic Symposium on Building Physics June 2014 Lund, Sweden

The comprehensive housing renovation approach

Energy-efficient Building in Greenland: Investigation of the Energy Consumption and Indoor Climate

Heriot-Watt University

Thermal comfort assessment of Danish occupants exposed to warm environments and preferred local air movement

Experimental and theoretic investigations of thermal behavior of a seasonal water pit heat storage

Computational Fluid Dynamics and Building Energy Performance Simulation Nielsen, Peter Vilhelm; Tryggvason, T.

Sensitivity Analysis of Personal Exposure Assessment Using a Computer Simulated Person Brohus, Henrik; Jensen, H. K.

Published in: NSB 2014: 10th Nordic Symposium on Building Physics June 2014 Lund, Sweden

Slab cooling system design using computer simulation

Hardware-in-the-loop (HIL) Test of Demand as Frequency Controlled Reserve (DFR)

Wood stove material configurations for increased thermal comfort

Published in: NSB 2014: 10th Nordic Symposium on Building Physics June 2014 Lund, Sweden

CHP from Updraft Gasifier and Stirling Engine

High efficient ammonia heat pump system for industrial process water using the ISEC concept. Part 1

Simulation and Energy Analysis of Thermal Environment of Unassisted Passive Solar House

Rasmus Elbæk Hedegaard et al. / Energy Procedia 132 (2017)

Thermal Control in Buildings by John Straube (updated )

Radiant Floor Cooling Combined with Mixing Ventilation in a Residential Room Thermal Comfort and Ventilation Effectiveness

BUILDING ENERGY DEMAND AGGREGATION AND SIMULATION TOOLS A DANISH CASE STUDY

Energy impact of ASHRAE s museum climate classes: a simulation study on four museums with different quality of envelopes

Field investigation on indoor thermal environment of a high-rise condominium in hot-humid climate of Bangkok, Thailand

Renovation of a Detached Single-Family House into an Energy Efficient Low Energy House Larsen, Tine Steen; Maagaard, Steffen; Jensen, Rasmus Lund

State-estimation of wind power system of the Danish island of Bornholm

Multi-objective optimization of die geometry in ingot forging

2006 Building Science Press All rights of reproduction in any form reserved.

Performance of Ductless Personalized Ventilation in Open-Plan Office - Field Survey

The Thermal Performance of Tradical Hemcrete.

CAE 331/513 Building Science Fall 2016

IEA Annex 58: Full-scale Empirical Validation of Detailed Thermal Simulation Programs

Efficiencies of flat plate solar collectors at different flow rates

Aalborg Universitet. Energy Gaining Windows for Residental Buildings Kragh, Jesper; Laustsen, Jacob Birck; Svendsen, Svend. Publication date: 2008

APISSEQ Sisimiut Greenland 1st winter survey 2011

Control of heat pumps

Intelligent Glazed Facades for Fulfilment of Future Energy Regulations Winther, Frederik Vildbrad; Heiselberg, Per Kvols; Jensen, Rasmus Lund

Available online at ScienceDirect. Procedia Technology 23 (2016 )

The Effects of Set-Points and Dead-Bands of the HVAC System on the Energy Consumption and Occupant Thermal Comfort

Kull, Tuule Mall; Simson, Raimo; Thalfeldt, Martin; Kurnitski, Jarek Influence of time constants on low energy buildings' heating control

Assessing the energy performance of modern glass facade systems

CITIES DSF B

Benefits of Integrating Geographically Distributed District Heating Systems

The Pinch-method Applied on a Biomass Gasifier System

Published in: CleanTech for Sustainable Buildings: From Nano to Urban Scale (CISBAT), Lausanne, September 2011

Optimal Investment Paths for the Danish Energy System in the CEEH Modelling System

Transcription:

Downloaded from orbit.dtu.dk on: Jul 06, 2018 Demand side management for smart district heating Big, Oovidiu; Li, Hongwei; Svendsen, Svend Published in: Energy Procedia Publication date: 2016 Document Version Version created as part of publication process; publisher's layout; not normally made publicly available Link back to DTU Orbit Citation (APA): Big, O., Li, H., & Svendsen, S. (2016). Demand side management for smart district heating. Energy Procedia. General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. Users may download and print one copy of any publication from the public portal for the purpose of private study or research. You may not further distribute the material or use it for any profit-making activity or commercial gain You may freely distribute the URL identifying the publication in the public portal If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.

Available online at www.sciencedirect.com Energy Procedia 00 (2015) 000 000 www.elsevier.com/locate/procedia The 7 th International Conference on Applied Energy ICAE2015 Demand Side Management for Smart District Heating Ovidiu Big a, Hongwei Li a, Svend Svendsen a a Technical University of Denmark,Department of Civil Engineering, Building 118, 2800 Kgs. Lyngby, Denamark Abstract The influence on the district heating network design and operation by using the energy storage capability inside the building is studied on different types of buildings under Danish climate. The building envelope has significant role in buildings energy consumption but also in building time constant. The results show that by the extensive renovation the energy consumption and the peak load could be reduced with more than 55% for two heating systems: radiant floor heating and radiators convective heating. Light renovation case has the peak load and energy consumption decreased with values between 25% and 35%. By making the light renovation, the heating system needs a minimum supply water temperature of 58ºC in order to cover the thermal comfort. Through extensive renovation, the supply water temperature could be reduced to 50ºC which makes it possible to transform the District Heating Temperature into Low Temperature. The building time constant for the extensive renovation is 86 hours which is double than a light building renovation and 53 hours higher than a non-renovated building. In the end of the paper is developed a formula which has the purpose to validate the results of virtual simulations. The relative percentage difference between the theoretical calculation and the virtual simulation results are between 2.5% and 17.5%. 2015 The Authors. Published by Elsevier Ltd. Selection and/or peer-review under responsibility of ICAE Keywords:Smart District Heating; Energy Performance; Thermal Response of Buildings; Time Constants. 1. Introduction The aim of this paper is to investigate the impact of energy savings strategies on District Heating Network (DHN). The heating system type is also considered as it can affect the balance between energy consumption and peak loads. Other characteristics that will be looked into are the building's envelope proprieties which can influence the heat storage capacity of the building, the peak load, and the energy consumption. It is analyzed also the indoor temperature decay of three types of buildings by using virtual simulation and theoretical calculation. The software program used to make the virtual investigations presented above is mainly IDA ICE [EQUA 2013] version 4.6.1.

2 Ovidiu Big / Energy Procedia 00 (2015) 000 000 2. Methods The following chapters include virtual simulations of indoor environments. The same building model was used for all investigations using the software IDA ICE 4.6.1 which is a dynamic simulation tool. Mainly, the simulations were focused on the yearly energy consumption and the peak loads. In the last chapter a mathematical calculation is developed and further the results are compared with the virtual simulations results. 2.1. Heating System Design The space heating system is designed according to DS418. Two heating systems were designed: floor/radiant heating and radiators/convective heating. The heat output were adjusted by proportional controllers which have the target set points the Operative temperature of 20 C. The proportional temperature controller was set to a dead band of 0.5 C, which means that the radiators will start heating from a temperature of 19.75 C and will stop at the temperature of 20.25 C[1]. 3. Building Description In this section is described the characteristics of the building being investigated. It is investigated a single family house which has one floor, i.e., the ground floor with a total floor area of 140 m 2. The building has 12 rooms (Figure 7) with an interior height of 2.6 [m]. The roof of the building is considered flat. The ceiling proprieties, for the three investigated cases, are given in Table 1. Fig. 1. (a) Building geometry; (b) 3D view Table 1. Construction proprieties Material Thickness [m] Thermal Conductivity [W/mK] Density [kg/m 3 ] Specific Heat Capacity[J/kgK] Ceiling for existing and light renovation (from inside to outside) Wood 0.016 0.14 500 2300 Rockwool 45 wood 63 0.1 0.05587 47.6 858.3 Ceiling for heavy renovation (from inside to outside) Wood 0.016 0.14 500 2300 Rockwool 45 wood 63 0.4 0.05587 47.6 858.3 The building is located in Copenhagen, thus the weather file for this location were used. Three types of houses were investigated: the existing building which is built in 1950 and two cases of renovation: light and extensive renovation respectively (Table 2). 4. Possibilities of Low Temperature District Heating The aim of this chapter is to investigate if the existing system could be used for low-temperature district heating, if the building will be renovated at different stages. By making the light renovation the heating systems needs a maximum supply temperature of 58 C in order to cover the thermal comfort. Through

Table 2, Windows proprieties Existing Light Extensive Building Renovation Renovation g (SHGC) 0.76 0.63 0.5 T 0.7 0.6 0.38 Tvis 0.81 0.78 0.65 U [W/m 2 K] 3.2 1.5 0.9 Frame fraction [0-1] 0.1 0.1 0.1 Frame U [W/m 2 K] 3.2 1.5 0.9 Envelope Infiltrations 0.3269 [L/m² floor] 0.27793 0.27793 Ovidiu Big / Energy Procedia 00 (2015) 000 000 extensive renovation the supply temperature could be reduced to 50 C which makes it possible to transform the DH into Low Temperature. Therefore, if it is desired Low Temperature District Heating, heavier renovations should be considered, but also with light renovations lower temperatures can be achieved. The yearly heating demand and peak load are presented in Figure 2. It can be observed that the renovation levels have a significant impact on the building energy consumption. Regarding the two heating systems investigations, there are recorded different consumptions and peak loads. For the existing building study, the difference is smaller in comparison with the two cases where the houses were renovated. The yearly energy consumption for the floor heating is higher with 2%, 15% and 10% in comparison with radiators consumption. The peak load for radiators is smaller with 14%, 19% and 17% in comparison with the floor heating peak loads. Fig 2. (a) Yearly heating demand (b) Peak load of different buildings type In both graphs it can be seen that floor heating has higher energy consumption and peak load compared with the radiators [2]. This could be explained by the fact that radiant heating systems need to heat the thermal mass of the floor and afterwards the air temperature is heated by convection, thus the floor hot surface warms up the indoor air [3]. Another reason of higher consumption is due to the floor connection with the soil. While in the case of radiators the thermal energy is transferred much easier to the indoor air by direct convection. The building envelope has a significant influence on the DHN design and operation. The yearly energy consumption and the peak load are greatly reduced by simple renovations and this leads to lower pipes dimensions and lower power DH plants when future networks are planned. By making a light building renovation the yearly energy consumption is reduced with 35% for the radiators convective heating and 25% for the radiant floor heating, and the peak load is reduced by 30% for the radiators case and 25% for the FH heating system. The extensive renovation has even higher reductions over 55% for the peak load and yearly energy consumption for both heating systems. 5. Building Time Constant 5.1. Temperature Response of different Building Types Having One Zone Representation The time constant could be computed by executing a few simulations in IDA ICE. Firstly, it was investigated the time constant of a building having a single zone (Figure 3) [4]. It was created a weather

Temperature [⁰C] 10 4 Ovidiu Big / Energy Procedia 00 (2015) 000 000 9 8 7 6 5 4 3 2 1 tc=36h tc=21h Fig 3. One zone time constant tc=61h 0 1 24 47 70 93 116 Time [hours] temperature decay 63% Extensive Renovation Light Renovation Existing Building file having a constant temperature of 10 degrees, with no solar radiation no wind conditions and no air humidity and the model has no internal gains [5]. The constant temperature was kept until a steady thermal indoor condition was reached; afterwards a step change was applied so the ambient temperature was reduced to 0 C. From that point the indoor temperature drop is recorded. Thus, the stored energy in the building thermal mass is released to the ambient air, and depending on the thermal mass properties (light, heavy...) it will determine the temperature drop. In Figure 3 is shown the time constants of the three types of buildings. It can be seen that even though there is no thermal mass, the time constants are still high. As it was expected the existing building is the first building which has the fastest temperature drop, followed by the light renovation building and the extensive renovated building 5.2. Temperature Response of Different Building Types Having 12 Zones representation In the multiple zone building, the time constant must be analysed individually for each zone. However, the same methodology, to find the time constant, was applied as for the one zone investigation. Generally, the small zones have a higher time constant due to their low exposure to the outdoor environment (Fig. 2). Time[hours] 100 90 80 70 60 50 40 30 20 10 0 Existing Building Light Renovation Extensive Renovation Time [hours] 100 90 80 70 60 50 40 30 20 10 0 Existing Building Light Renovation Extensive Renovation 33 43 86 Fig 4. (a) Multiple zones time constant; (b) Zones summing up The time constant for each building (Figure 4 (b)) was found by summing up the zones. The new time constants are higher than the one zone time constant. But, the increase of the time constant is different for each type of building: for the existing building time constant is higher with 36%, Light renovation with 16% and the extensive renovation is bigger with 29%. As it can be seen in the figures above the time constant is considerably influenced by the internal masses especially by the internal walls [6]. Therefore, the building time constant cannot be accurately determined by a single zone representation of the entire building. 5.3. Thermal Decay of Radiant Floor Heating and Radiator Convection Heating In this section simulations of the two heating systems are made in order to find the room temperature response when the two different heating units are turned off. One week simulations are made with the

Room Temperature [ C] Ovidiu Big / Energy Procedia 00 (2015) 000 000 same settings as for a realistic situation, except on internal heat gains which were set to zero. During this week the temperature set point is 20 C. On the fifth day of the week the heating system is completely turned off. The temperature decay analysis was made at room level (Bedroom-Figure 5). 20.5 20 19.5 19 18.5 18 17.5 17 16.5 16 Extensive Renovation FH Existing Biulding FH Light Renovation Radiators 1 31 61 91 121 151 Time [minutes] Fig 5. Bedroom s Temperature Decay Light Renovation FH Extensive Renovation Radiators Existing Biulding Radiators Figure 5 shows the time when the heat supply was stopped. The radiant heating (FH) has a slower decrease of temperature compared with the convection heating (radiators) cases. Even the existing building with radiant heating has slower temperature decay than the extensive building with convection heating. This is due to the capacity of the floor to store heat. After the heat unit is stopped the floor is releasing heat indoors, so the temperature has a slower decrease in the first hours. In the case of extensive renovated building, in three hours, from 12:00 to 15:00 the temperature drop of radiators is 2.5 C, while the FH system reaches 1.3. Also the other two buildings types have a different temperature drop between FH and radiators, but with a smaller difference of 0.9 C for the existing building and of 0.84 C for the light renovated building. 5.4. Room temperature Variation after Heating Load Reduction This subchapter is made with the purpose to verify/validate the results obtained through virtual simulations, with the results found by using a formula. Therefore, it will be made a result comparison between the two methods. The two methods will be used to evaluate the room temperature variation after heating load reduction. 5.5. First method: Forecast of Room Temperature by Theoretical Calculation (formula approach) The formula to calculate the room temperature variation after heating load reduction is presented below: T i=(t s-t 0)+T 0+(Ts-Ts+T0 T0)exp(-t/) (1) where T i is the room temperature after the heat reduction was applied, is the heating load variation, <1 is the load reduction ( >1: load increase; =0: no variation (constant heat supply)), =q/q 0; (2) where q is the actual heating load during this time period, q 0 is the heating load calculated based on initial temperature difference (T s-t 0), T 0 is the ambient temperature, T s is the room temperature at the beginning (room temperature is constant 20ºC), is the time constant[7]. Based on equation (1), it can be calculated the room temperature variation for each time step. The main reason of developing this formula is to find out the percentage of extra energy needed in different situations. For example if we want to increase the room temperature from 18 to 20ºC in 2 hours, what will be the percentage of extra energy? How much energy do we need to have 20ºC in 2 hours? In this investigation is involved multiple variables, among them the most important can be considered the weather conditions, the ambient temperature, the time constant of the building or the internal gains.

6 Ovidiu Big / Energy Procedia 00 (2015) 000 000 On the other hand, the same formula can be used for load heating reduction (Setbacks strategies). We would like to know the room temperature after a period time while the heat load was reduced with a specific percentage. For example what would be the room temperature after 1 hour, (or after 2, 3 hours) if the heat supply was reduced with 10% (or 15, 30%). 5.6. Second method: Forecast of Room Temperature by Virtual Simulations Therefore, it is built up a model having no solar gains. The ambient temperature (T 0) is set to a constant temperature of -12ºC. Due to software s limitations, it is shown only static simulations results. The dynamic simulations give wrong/unexplained results; therefore they are not presented in the paper. The room temperature (T s) is set also to be constant at 20ºC. The virtual simulation was running until the indoor temperature reached a constant temperature of 20 ºC. Afterwards the heating system was stopped and respectively the indoor temperature decreased. Table 3. Room temperature variation after heat load reduction Ts [ C] T0 [ C] X Tsx [ C] T0x [ C] t [h] τ [h] Ti [h] 20-12 0 0 0 10 Equation (1) 33 11,63 with Radiators 10 Existing Virtual IG FH 11,97 Building Simulations No Radiators 8,47 IG FH 10,48 Equation (1) 41 13,07 with Radiators 12,04 Light Virtual IG FH 13,41 Renovation Simulations No Radiators 11,18 IG FH 12,05 Equation (1) 83 16,37 with Radiators 14,18 Extensive Virtual IG FH 14,93 Renovation Simulations No Radiators 13,23 IG FH 14,04 Note: IG internal gains, FH floor Heating; Ts, T0, X, Tsx, T0x, t, τ, Ti are explained in subchapter 5.5.1 5.7. Results It can be seen, also in this investigation, the advantage of radiant heating where the temperature decay is slower than the convective heating system. If we judge the system (radiant system) from this point of view, it has an asset in front. Mainly, in all the types of simulations the convective heating has faster temperature decay. First thing which can be observed is that the FH system has closer results to the formula outcome. Thus the discrepancy between the FH and the hand calculation is smaller. In general the simulations with internal gains present more suitable results with the outcome of the formula. In conclusion, the best fit between virtual simulation and the theoretical calculation is the case of radiant heating (FH) with the presence of internal gains. However, the formula does not take into consideration the internal gains. Thus, if we want to have a more reliable comparison between the theoretical calculation and virtual calculation, we need to consider only the case with no internal gains. 6. Conclusion The yearly energy consumption and the peak load are greatly reduced by simple renovations and this leads to lower pipes dimensions and lower power for DH plants when future networks are planned. The temperature stability of the radiant heating system (FH) is better than the radiator heating, but the energy consumption is higher. The temperature decay and increase temperature speed is higher for the convection heating system. The time constant is different for every type of building depending on building envelope and internal masses. In order to determine accurately the time constant, the buildings must be modelled according to their thermal configuration, including their internal walls. The developed formula has closer results to virtual simulation for the radiant heating system. The theoretical calculation is in the first stage of development and it needs further improvements and validation. Moreover, it can be added more variables into its structure, but first it would be relevant to validate the base/simple form of it.

Ovidiu Big / Energy Procedia 00 (2015) 000 000 References [1] Marek Brand, Patrick Lauenburg, Janusz Wollestrand, Viktor Zboril. Optimal Space Heating System for Low-Energy Single-Family House Supplied by Low-Temperature District Heating; 2013. [2] A. Patrick Lauenburg, B. Marek Brand, C. Janusz Wollerstrand. Space Heating in District Heating-Connected Low-Energy Buildings; 2012. [3] Guo Lirong, Tan Yufei, Li Baochang, Impact Analysis of Heating Methods on Room Temperature Stability; 2011. [4] Bhatttacharya, M. C. A new improved finite difference equation for heat transfer during transent change, 1984. [5] Raychaudhuri, B. C. Transient Thermal Response of Enclosure. The Integrates Thermal Time-Constant. 1965. [6] Tsilingiris, P. T. On the thermal time constant of structural walls; 2003. [7] Hongwei Li, Stephen Jia Wang, Load Management in District Heating Operation, ICAE 2015.

8 Ovidiu Big / Energy Procedia 00 (2015) 000 000 ADDITIONAL INFORMATION FOR ADMINSTRATION USE BY THE ORGANIZATION COMMITTEE (* ICAE2015 organization committee reserves the right to decide the paper type in the final program) PLEASE SELECT (CLICK) ONE OF THE FOLLOWING OPTIONS: I PREFER TO PRESENTING MY PAPER AS ORAL POSTER ALL PAPERS PRESENTED AT ICAE2015 WILL BE PUBLISHED IN ENERGY PROCEDIA, IF YOU DO NOT WANT TO INCLUDE YOUR PAPER IN THE ENERGY PROCEDIA, PLEASE CLICK NO, I DO NOT WANT TO INCLUDE MY PAPER IN THE ENERGY PROCEDIA.