Fire Safety with Concrete Products. Rich Walke UL Codes and Advisory Services

Similar documents
Fire Safety with Concrete Products

Fire Safety with Concrete Masonry Products. NCMA/AIA CES COURSE C202a

Design & Testing of Fire Resistance and Smoke Resistant Barriers. Rich Walke UL Codes and Advisory Services

Testing of Fire Resistance and Smoke Resistant Assemblies. Rich Walke UL Codes and Advisory Services

FIRE RESISTANCE RATING OF TEK 7-1A CONCRETE MASONRY ASSEMBLIES

Fire Resistive Construction

65% Waste Output. 12% Water Use. 70% Electricity Consumption. What is the size of your footprint? Concrete Masonry Sustainable Construction

FIRE RESISTANCE OF NORLITE EXPANDED SHALE CONCRETE MASONRY

Fire Resistive Construction Based on the 2015 IBC BIANCO Education Day August 15, 2016

Fire Inspection and Code Enforcement, 7 th Edition. Chapter 6 Building Construction: Components Inspector II

FIRE RESISTANCE OF EXPANDED SHALE, CLAY AND SLATE CONCRETE MASONRY

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

Exception: All layers of single and multilayer reflective plastic core foil insulation shall comply with Section 2604.

General Building Information

FIRE RESISTANCE TESTS OF BRICK VENEER / WOOD FRAME WALLS J. GREGG BORCHELT

Building Codes and Ordinances ARC 227

Protecting Penetrations in Fire Rated Construction

Fire Resistance and Protection of Structures

1.5-Hour Fire Rating. Assembly Information

The Lexington Division of Fire and Emergency Services. Fire Chief Robert G. Hendricks

FIRE AND SMOKE PROTECTION FEATURES

3-Hour Fire Rating. Assembly Information

Common Firestop Issues in Wood Framed Commercial Construction

APPENDIX DETAIL (1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

2012 IBC Inspection of Fire-resistance Rated Walls

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

SECTION 702 DEFINITIONS

ALLOWABLE STRESS DESIGN OF CONCRETE MASONRY LINTELS. TEK 17-1C Structural (2009) Related TEK: Uniform load. Triangular load. Concentrated loads

The Building Codes A.R.E. Building Design and Construction Exam Prep

Technical Information for ProBlock Masonry Units ASTM C-90 Compliance

Technical Information for ProBlock Masonry Units ASTM C-90 Compliance

2006 to 2012 IBC. Significant Changes

Oneonta Block Company Web Fire Rating for Regular Weight Block using Limestone

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings. John Buddy Showalter, PE VP, Technology Transfer American Wood Council

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

Fundamentals of Building Construction: Materials and Methods

Masonry movement joints

Copyright 2016 UL LLC.

2012 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs


Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD.

Knowledge Objectives (3 of 3)

Minneapolis Community and Technical College T-Building Floor 2 Student Affairs Cost Estimating Form Templates - Exhibit C

2012 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs

REINFORCED CONCRETE MASONRY SECTION

Fire Performance. By Gary Sturgeon, B.Eng., MSc., P.Eng. Technical Services Engineer, CCMPA. w w w. c c m p a. c a 5-0

2015 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs

FCIA Webinar Gypsum Wall Patching

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

NEWS LETTER MARCH 27, 2009

CONCRETE MASONRY VENEERS TEK 3-6C

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3%

Module 8: Ontario Building Code Fire and Spatial Separations

FIRE AND SMOKE PROTECTION FEATURES

FIRE AND SMOKE PROTECTION FEATURES

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

A Review of Thermal and Ignition Barrier Requirements for Spray Foam Insulation

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321)

Appendix M : Life Safety and Fire Protection Assessment

TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS

FRANKLIN VILLAGE APARTMENTS Building I Franklin Street Morristown, NJ Block: 3901 Lots: 4,5,6

UNDERSTANDING THE MASS TIMBER CODE PROPOSALS. A Guide for Building Officials

0103 Plan Reading 4% Read plans to verify the project conforms with the code, approved plans, and construction documents.

NCMA TEK TEK 18-1A COMPRESSIVE STRENGTH EVALUATION OF CONCRETE MASONRY

APPLICATION AND CERTIFICATE FOR PAYMENT

TEK 6-6B Energy & IAQ (2009) DETERMINING THE RECYCLED CONTENT OF CONCRETE MASONRY PRODUCTS. Related TEK: 6-9B, 6-9C

Outcomes of ICC Tall Wood Ad Hoc Committee: Proposals and Discussion

2015 Proposed Residential Code with Amendments

Applying the Building Code During Design

Pre-schematic Considerations. Who. What. Where

Minimum Requirements For One & Two Family Structures FBC 6 th Edition (2017)

2009 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

Fire Considerations. Combustible Cladding and Components Of Exterior Walls and Curtain Walls. APEGBC/BCBEC Seminar, April

IRC 2015 Significant Changes

Technical Note. Flat Plate Voided Concrete Slab Systems

June 7, 2012 PARTIES INTERESTED IN HVAC DUCT ENCLOSURE ASSEMBLIES

Introduction. This Part One will address; Type 1 Fire Resistive and Type 2 Noncombustible buildings.

The International Building Code (IBC ) is a model code that provides minimum requirements to safeguard the public health, safety and general welfare

S T R U C T U R. Technology. magazine. Software for the Structural Design of Masonry. The Design Basis. Copyright

FCIA Barrier Management Series. Barrier Management Policies

SECTION HOLLOW METALWORK. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

Masonry Structures James Robert Harris, PE, PhD, and Fredrick R. Rutz, PE, PhD

PRODUCT CATALOG. The following categories highlight the MBS product catalog for the various types of materials, including but not limited to:

DIVISION 7 - THERMAL AND MOISTURE PROTECTION

DIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories

VERIFICATION OF MASONRY DESIGN SOFTWARE NATIONAL CONCRETE MASONRY INSTITUTE PHASE III

HOT SPRINGS FIRE DEPARTMENT EVALUATION OF DOWNTOWN LEGACY STRUCTURES Savoy Hotel Thompson Building Dugan Stewart Building May 16, 2012

KELLER PARKWAY - FM 1709

THE DISASTERS OF SEPTEMBER 11, 2001 DAVID T. BIGGS, P.E. Principal Ryan-Biggs Associates, P.C. Troy, New York USA

ACCEPTANCE CRITERIA FOR PRECAST STONE VENEER

WALL SYSTEMS ( Ref: The Building Illustrated, Ching, Francis DK )

Building Excellence IV Capital Levy Projects Under Construction

2018 IBC Chapter 6 Types of Construction

three design codes, building codes Structural Requirements Structure Requirements Structure Requirements serviceability efficiency

FIRE-RESISTANCE-RATED CONSTRUCTION

COPYRIGHTED MATERIAL. Contents. 1 Making Buildings 3. 3 Wood Foundations and. Preface to the Sixth Edition xi. Sitework 31

ACCEPTANCE CRITERIA FOR PRECAST STONE VENEER PREFACE

NFPA 285 Assemblies. Table of Contents

PRESCRIPTIVE COMPLIANCE METHOD

Transcription:

Fire Safety with Concrete Products Rich Walke UL Codes and Advisory Services UL and the UL logo are Trademarks of UL 2015 November 16, 2015

Fire Protection Triad 1 Automatic Detection Systems (Alarms) 2 Automatic Sprinkler Systems (Sprinklers) 3 Compartmentation - (Fire Resistive Construction) 2

Independent support and breakaway connectors to allow collapse of adjacent construction 3

Firewall Performance 4

Firewall Performance 5

Firewall Performance 6

Consequence of No Fire Walls 7

Use of Masonry to Create Protected Means of Egress Egress Protection Exit Rated Walls Stair and Elevator Shafts 8

Concrete Fire Ratings Based on Testing ASTM E119 / UL 263 Three methods for determining fire-resistance ratings: 1. Fire Testing 2. Listing Service 3. Calculation/Other Methods 9

Concrete Fire Ratings Based on Listing Services Three methods for determining fire-resistance ratings: 1. Fire Testing 2. Listing Service 3. Calculation/Other Methods UL 618: UL Standard for Safety for Concrete Masonry 10

Concrete Fire Ratings Based on Calculation Methods Three methods for determining fireresistance ratings: 1. Fire Testing 2. Listing Service 3. Calculation/Other Methods 11

Available Resources National Concrete Masonry Association www.ncma.org American Concrete Institute www.aci.org Portland Cement Association www.cement.org The Masonry Society www.masonrysociety.org 12

Available Resources Cont. International Building Code Prescriptive Fire Resistance, Section 720 International Building Code Calculated Fire Resistance, Section 721 International Existing Building Code Resource A 13

Available Resources Cont. American Insurance Services Group, Inc. (210) 469 3922 Fire Resistance Ratings ACI 216.1 / TMS 0216 Standard Method for Determining Fire Resistance of Concrete and Masonry Construction Assemblies 14

National Concrete Masonry Association TEK Notes TEK 5-8B: Detailing Concrete Masonry Fire Walls TEK 7-1C: Fire Resistance Rating of Concrete Masonry Assemblies TEK 7-2: Balanced Design Fire Protection TEK 7-3A: Firestopping for Concrete Masonry Walls TEK 7-4A: Foam Plastic Insulation in Concrete Masonry Walls All available free online See www.ncma.org Solutions Center ETEK 15

Applicable NCMA TEK on Fire Resistance TEK 7-1C: Fire Resistance Rating of Concrete Masonry Assemblies TEK 7-3A Firestopping for Concrete Masonry Walls TEK 7-5B: Evaluating Fire Exposed Concrete Masonry Walls TEK 7-6: Steel Column Fire Protection All available free online See www.ncma.org 16

Calculated Fire Resistance Method Fire ratings for concrete products are a function of: Aggregate type Equivalent thickness 17

Equivalent Thickness Equivalent Thickness, T e, is the solid thickness that would be obtained from the same volume of concrete without cores H H L L W W T e = % solid x actual thickness 18

ACI 216.1 / TMS 0216 Applicable to: Concrete Concrete masonry Clay brick and tile masonry Effects of finish materials on fire resistance Incorporated into the I- Codes 19

Filling Cores When the hollow cores of concrete masonry are filled, the equivalent thickness is considered to be the actual thickness of the concrete masonry unit Thus all filled 8-inch and many 6-inch CMU have 4 hour ratings 20

Finishes Finishes are an excellent way of increasing the fire resistance rating of existing assemblies 21

Glazed Units The calculated fire-resistance rating procedure for a glazed unit is the same as for conventional units Same charts based on equivalent thickness and aggregate type 22

Beams, Lintels, Columns, and Floors The IBC and ACI/TMS 216 Standard have tables for determining the calculated fire resistance rating for masonry and concrete lintels, beams and columns as well as for concrete floors 23

Clay Brick & Tile The IBC and ACI/TMS 216 Standard also address calculated fire resistance rating for clay brick and tile masonry wall assemblies (very similar to the concrete masonry tables and procedures) 24

Control Joints TEK 7-1C 25

Summary Concrete products are inherently fire resistive Fire ratings are easily determined by the various methods available Compartmentation with concrete product is effective 26

Questions / Comments 27

Thank You for Attending!!! Rich Walke Codes and Advisory Services Department Underwriters Laboratories 333 Pfingsten Road Northbrook, IL 60062 Richard.N.Walke@UL.com (847) 664-3084 www.ul.com 28