ModuSec. The Secure Modular Construction System. Designed To Meet All The Criteria Required For. The Protection Of Critical Environments.

Similar documents
Entrance Control Range

MSP Modular Building System

PASSIVE FIRE PROTECTION Specialists for the construction, infrastructure, transport, energy, industrial and commercial sectors.

CHAPTER 3: Modern Methods of Construction (MMC)

TERRACE FACTORY - TYPE A1

SECTIONAL OVERHEAD DOORS

Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD.

combustibility behaviour of insulation products

CHAPTER 3: Modern Methods of Construction (MMC)

Blast Resistant Enhanced Curtain Wall. Reference Brand: Sapa Building System Elegance 85PF GENERAL DESCRIPTION PERFORMANCE

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

Pyroplex construction products. Pyroplex timber door products. Pipe Collars. Pipe Wraps

Steelwork and Security Kiosks

4.1.3 Project Manual

Exterior Wall Solutions Building Shell

Cavity Tray Application

SPECIFICATION For the Supply and Installation of BRITAL SG-2-56-HFF. Two Sided Structurally Glazed Curtain Walling. (Horizontal Structural joints)

EAB PALLET RACKING ALFA

EK Workplace protection against raid

Insulation - Products

Design guide to separating distances during construction

Notification of a Body pursuant to article 18 of the Construction Products Directive 89/106/EEC

GERI INDUSTRIAL ESTATE. T: , F: E:

SECTION OVERHEAD DOORS. Summary of Structural Steelwork Drawings SECT IONAL OVERH EAD D OORS

TABLE OF CONTENTS Public Safety Building

SoftWall Partitions and Curtains

Far more. glass. than just. This success has not come about by. From its early days over 50 years ago, as. a small local glazing contractor,

Curtain Wall Stick System (Capped)

sandwich wall Other Hunter Douglas products

SoftWall Partitions and Curtains

Sliding Door Systems

Steelwork and Security Kiosks

Get in front of the Q SBD and Approved Document Q

Loss Prevention Standard

THE PANEL YOU NEED, WITH THE CORE YOU WANT, ON THE DATE YOU NEED IT. ISOCLAD

INSULATING CONCRETE FORMWORK SYSTEM

Structural Steel Products UK & Ireland. Multideck Technical Handbook

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

COPYRIGHTED MATERIAL. Contents. 1 Making Buildings 3. 3 Wood Foundations and. Preface to the Sixth Edition xi. Sitework 31

WOOD USE IN NONCOMBUSTIBLE BUILDINGS

Planning and installation instructions

Moduline. Acoustic Enclosure System. Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components

ACTIVE FIRE PROTECTION SOLUTIONS PASSIVE FIRESTOPPING SOLUTIONS

Sectional Overhead Doors SECTIONAL OVERHEAD DOORS

Delta Level 1000 Hinged Lip Pit Mounted & Suspended Frame Dock Leveller

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

Insulbreak. Insulation. thermal break solution

FIRE PROTECTION AND PERFORMANCE DRY LINING BOARD THE ULTIMATE IN FIRE PROTECTION! 91 mins fire integrity and 86 mins fire insulation on 9mm board

Technical information & installation advice

PROCUREMENT AND CONTRACTING DOCUMENTS GROUP

Safe and Secure Solution PRODUCT CATALOGUE

COMPETENCY ANALYSIS PROFILE General Carpenter 403A. (All unshaded skill sets must be demonstrated/completed)

Designation of a Notified Body pursuant to the Construction Products Regulation

Approved Document Q Security Dwellings. Key Facts Scope of Doc Q Including Doors, Door Hardware and Windows

Value Benefits of Modular Construction in Building Extensions

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

SPECIFICATION For the Supply and Installation of BRITAL UN Four Sided Unitized Structurally Glazed Curtain Walling

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

Light steel frame walls

BBA 001 Documents included under the scope of BBA s ISO UKAS accreditation

A4/8 PS AW2324D Issue 10 May Permishield

Price List - All Qualifications

CERTIFICATE OF APPROVAL No CF 5235 AVIANS INNOVATIONS TECHNOLOGY PVT. LTD

GypLyner IWL Independent wall lining system

DESIGN & CONSTRUCTION GUIDELINES

Metropolines 2 / / 2

SIDERISE FLX flexible acoustic barriers for suspended ceilings

SLIDING Product Information

Designation of a Notified Body pursuant to the Construction Products Regulation

Protective devices according to EN ISO 12100

Ameriplate. Rain Screen Wall System

DICTATOR Lift Shaft System

Designation of a Notified Body pursuant to the Construction Products Regulation

PRODUCT CATALOG

INSTALLATION MANUAL KOCH

Power IT Compact Secondary Substations, CSS. Technical catalogue for sheet steel substations

Steel frame Loadbearing steel framed systems

Division 00 Procurement and Contracting Requirements

GypWall QUIET Acoustic separating wall system

Day Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red

Uniclass. L384:P41 CI/SfB. (22.3) Xh2. British Made TOUGH, RELIABLE, USER-FRIENDLY. page 37

TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS

YOUR SPACE. Buildings for your lifestyle

Nüsing Visioline glass wall

Alara-Lukagro. Krijgt alles stil. Cruise ships

heroal W 77 HI Window systems

Height Safety Solutions. Fall Protection Systems. Safepro2, Saferidge & Safetraxx

Delta Part Liber Superthermic Insulated Bi-Folding Door. Product Data Sheet 7 / 4

MODULAR ACCESS SYSTEMS PRODUCT OVERVIEW

Product Data Sheet. QuadCore Karrier. Applications

A. This Section includes steel cable trays and accessories.

Construction applications

FIRE PROTECTION AND PERFORMANCE DRY LINING BOARD THE ULTIMATE IN FIRE PROTECTION! 91 mins fire integrity and 86 mins fire insulation on 9mm board

Commercial Air Permeability Checklist

SECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.

Ruukki Construction is one of the leading European suppliers of metal components, systems and complete solutions for construction and mechanical

comar9p.i complementing architecture L41:P43 D1:X46

A4/6 PS AW1551 Issue 4 Nov Permishield

DIVISION 0 - BIDDING REQUIREMENTS, CONTRACTOR FORMS AND CONDITIONS OF THE CONTRACT

Technical Description For MK-CTX Office Cabins

Transcription:

ModuSec The Secure Modular Construction System Designed To Meet All The Criteria Required For The Protection Of Critical Environments To Any Size As A Complete Enclosure Or As Walls Only - Inside Or Outside

The ModuSec System 100mm steel faced pre-finished wall and ceiling panels with a high performance thermal barrier core (Pyrofoam) mechanically lock together to form a protective enclosure. Each panel is manufactured to size and specification allowing rapid installation on site.

Security Rated Panels 20mm over clad option for higher levels Mesh foamed into in panels Different steel mesh configurations foamed in for CPNI/SR panels

No intermediate support required for ceilings spanning up to 6m for standard panels or 3.8m for SR SEAP 3+ panels Optional floor panels to form completely sealed 6 sided enclosure

Construction Options

Remtech/RCS has over 25 years experience in building protected spaces. In house steel fabrication allows us to build to any size. We are specialists in protecting large open environments as full enclosures or walls only Large single span enclosures with vertically orientated walls Ceilings supported in the web of the steels (shown) or on top of the steels Smaller internal steels with shorter spans

Horizontally fixed wall panels allow construction to any height (over 8m in this example). High security testing cell

SR Server Room with curved roof & architectural cladding Server Room with single pitch roof and self coloured ModuSec wall panels High security mains water pumping station with external timber cladding 2 storey data centre plus flat roof deck for plant. External cladding. External Construction with flat, curved or single or double pitch roof With or without additional architectural cladding - Single or double storey

Proposed 2 phase high security data centre project External ModuSec panels onto internal steel frames with standing seam steel tray roofs

Transportable Pods High security pod for a nuclear site with ModuSec external panels. Complete equipped server room being shipped to Africa.

ModuSec Design Criteria Forced Attack Options CPNI (ModuSec GS) LPS1175 Security Rating (SR) 1, 2, 3, 4 and 5 BS EN 1627/1630 to RC5 Fire EN1364/EN1634 90 minutes integrity & 90 minutes insulation for panels & doors - meeting limit temperatures recommended under BS/EN1047-2 for the protection of IT hardware Water/Smoke Resilient to IP66 plus options for IP67 Blast Tested by UK Government for blast protection. 100Kg TNT at 20m. Ballistics Option: Tested to BS EN 1522 Anti-ballistic rating FB4 (0.44 Magnum Hand gun)

Forced Attack Testing, Tools & Standards What do you want to protect against and for how long? Given enough time and the right tools, any barrier can be penetrated. Consider all measures together. Test Criteria: To cut a body sized hole for entry 400mm x 225mm with the designated toolset in time set for the standard Standard Attack/Test Times (minutes) Main Tools In Designated Toolsets LPS 1175 SR1-SR2 1/10 3/15 Opportunist attack LPS1175 SR3 5/20 CPNI (PBAS) BASE Forced entry with small manual tools LPS1175 SR4 10/30 Experienced attack with higher level tools LPS1175 SR5 10/30 Serious attack with high end battery powered tools EN 1627/1630 15/40 RC5 Serious attack with high end mains powered tools

Further enhanced security available against higher level tools like these large petrol driven disc cutters - plus Ballistic EN1522-1 level FB4 (or higher) & Secondary Blast ModuSec GS Approved for UK Government Use. For details contact CPNI.

Forced Attack Certification LPS1175 SR1 to SR5 All joints, corners, fixing to existing fabric included in the test procedure

Column Fixing For Horizontal Panels

Fire Certification BS476/EN1364/EN1634-90 minutes integrity & 90 minutes insulation for panels and doors. Paper will ignite and spread a fire at just 180 o C. Hardware will be destroyed at 70 o C. ModuSec stayed within 70 o C for over 90 minutes at the cold face with 1000 o C on the furnace side. Up to 6m panels approved so will protect environments of any size. Complete building assessment carried out by an independent test house (Warrington Fire). Tested for internal or external fires. Doors, windows, service entry all tested mounted in the panels. Obviates the risk of fire spreading between cells in co-location environments Recent arson attack on one of our server rooms in Denmark. Accelerants used and was many hours before fire services could gain entry. All hardware remained in working order.

Doors: 90/90 fire rated & security tested - including locks & cable way for access control Designed & tested specifically for the ModuSec System 2 part frame clamps to the wall panel Single or double doors available with a range of locking options to meet the highest levels of security

Large Doors Roller Shutter Door: LPS1175 SR5 & other standards Combine with a 2 hour rated fire curtain Sliding/Folding Door

Protected Service Entry Options Service entry can be provided at any point to any size or shape on site Pre-determined notification not required allowing total flexibility during fit out. Fully tested firestopping service available

Security Grilles Manufactured in house for the protection of service entry points to match security standard of the panels.

Ballistics Option With 18mm Overclad Tested by DJ Goode (UKAS Approved) to BS EN 1522/1523 Anti-ballistic rating FB4 (0.44 Magnum Hand gun). Tested to LPS 1175 SR5 & EN1627/30 RC5 using a mains powered reciprocating saw as opposed to current battery driven SR5 test. Hence far more power available.

Summary of Benefits & USP s In house design, manufacture of panels & doors, steel fabrication, delivery and installation guarantees a complete project will meet the specified standard. Proven track record and experience with free design advice to meet security standards. Core business is large scale high security projects The only system to be approved to LPS1175 SR5 at any size for partition walling or enclosures ModuSec GS panels approved to CPNI UK Government forced attack standard Build to any height with horizontally mounted panels & ceiling to any clear span with support Option for BS EN 1522/23 Anti-ballistic rating FB4 (0.44 Magnum Hand gun) or higher rating 90/90 fire rating on panels and doors with doors, windows, service entry tested mounted in the panels Blast tested with 100Kg TNT. Approved for secondary protection (e.g. behind glass or other cladding) Wipe clean surfaces with no wet trades mean a quick, clean build and maintenance free surfaces Standard non security panels integrate with the system for a complete seamless build For further details contact Remtech on 020 8786 8787